The package @braintree/sanitize-url before 6.0.0 are vulnerable to Cross-site Scripting (XSS) due to improper sanitization in sanitizeUrl function.
An XSS bug in internal error pages could have led to various spoofing attacks, including other error pages and the address bar. Note: This issue only affected Firefox for Android. Other operating systems are unaffected. This vulnerability affects Firefox < 85.
Cross-site scripting (XSS) vulnerability allows remote attackers to inject arbitrary web script or HTML via the page parameter to service-monitoring/src/index.php. This vulnerability is fixed in versions 1.6.4, 18.10.3, 19.04.3, and 19.0.1 of the Centreon host-monitoring widget; 1.6.4, 18.10.5, 19.04.3, 19.10.2 of the Centreon service-monitoring widget; and 1.0.3, 18.10.1, 19.04.1, 19.10.1 of the Centreon tactical-overview widget.
The WP to LinkedIn Auto Publish plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via PostMessage in all versions up to, and including, 1.9.8 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
A mutation XSS affects users calling bleach.clean with all of: svg or math in the allowed tags p or br in allowed tags style, title, noscript, script, textarea, noframes, iframe, or xmp in allowed tags the keyword argument strip_comments=False Note: none of the above tags are in the default allowed tags and strip_comments defaults to True.
All versions of package react-bootstrap-table are vulnerable to Cross-site Scripting (XSS) via the dataFormat parameter. The problem is triggered when an invalid React element is returned, leading to dangerouslySetInnerHTML being used, which does not sanitize the output.
DIAEnergie Version 1.7.5 and prior is vulnerable to a reflected cross-site scripting attack through error pages that are returned by “.NET Request.QueryString”.
An issue was discovered on Bell HomeHub 3000 SG48222070 devices. There is XSS related to the email field and the login page.
A vulnerability was detected in code-projects Simple Food Ordering System 1.0. The affected element is an unknown function of the file /editproduct.php. Performing manipulation of the argument pname/category/price results in cross site scripting. The attack may be initiated remotely. The exploit is now public and may be used.
This affects the package Crow before 0.3+4. When using attributes without quotes in the template, an attacker can manipulate the input to introduce additional attributes, potentially executing code. This may lead to a Cross-site Scripting (XSS) vulnerability, assuming an attacker can influence the value entered into the template. If the template is used to render user-generated content, this vulnerability may escalate to a persistent XSS vulnerability.
Revive Adserver before 5.1.1 is vulnerable to a reflected XSS vulnerability in userlog-index.php via the `period_preset` parameter.
An error in a page handler of the VRM may lead to a reflected cross site scripting (XSS) in the web-based interface. To exploit this vulnerability an attack must be able to modify the HTTP header that is sent. This issue also affects installations of the DIVAR IP and BVMS with VRM installed.
The Realteo WordPress plugin before 1.2.4, used by the Findeo Theme, did not properly sanitise the keyword_search, search_radius. _bedrooms and _bathrooms GET parameters before outputting them in its properties page, leading to an unauthenticated reflected Cross-Site Scripting issue.
A flaw was found in the gi-docgen. This vulnerability allows arbitrary JavaScript execution in the context of the page — enabling DOM access, session cookie theft and other client-side attacks — via a crafted URL that supplies a malicious value to the q GET parameter (reflected DOM XSS).
Revive Adserver before v5.2.0 is vulnerable to a reflected XSS vulnerability in the `statsBreakdown` parameter of stats.php (and possibly other scripts) due to single quotes not being escaped. An attacker could trick a user with access to the user interface of a Revive Adserver instance into clicking on a specifically crafted URL and pressing a certain key combination to execute injected JavaScript code.
On BIG-IP version 16.0.x before 16.0.1, 15.1.x before 15.1.1, 14.1.x before 14.1.2.8, 13.1.x before 13.1.3.5, and all 12.1.x versions, a reflected Cross-Site Scripting (XSS) vulnerability exists in an undisclosed page of the BIG-IP Configuration utility when Fraud Protection Service is provisioned and allows an attacker to execute JavaScript in the context of the current logged-in user. Note: Software versions which have reached End of Software Development (EoSD) are not evaluated.
Unvalidated input and lack of output encoding in the WP Shieldon WordPress plugin, version 1.6.3 and below, leads to Unauthenticated Reflected Cross-Site Scripting (XSS) when the CAPTCHA page is shown could lead to privileged escalation.
Revive Adserver before v5.2.0 is vulnerable to a reflected XSS vulnerability in the `status` parameter of campaign-zone-zones.php. An attacker could trick a user with access to the user interface of a Revive Adserver instance into clicking on a specifically crafted URL and execute injected JavaScript code.
A flaw has been found in code-projects Voting System 1.0. The affected element is an unknown function of the file /admin/candidates_edit.php. This manipulation of the argument Firstname/Lastname/Platform causes cross site scripting. Remote exploitation of the attack is possible. The exploit has been published and may be used.
The GiveWP – Donation Plugin and Fundraising Platform WordPress plugin before 2.10.0 was affected by a reflected Cross-Site Scripting vulnerability inside of the administration panel, via the 's' GET parameter on the Donors page.
The Elements Kit Lite and Elements Kit Pro WordPress Plugins before 2.2.0 have a number of widgets that are vulnerable to stored Cross-Site Scripting (XSS) by lower-privileged users such as contributors, all via a similar method.
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Netcad Software Inc. Netigma allows XSS Through HTTP Query Strings.This issue affects Netigma: from 6.3.5 before 6.3.5 V8.
This Advanced Order Export For WooCommerce WordPress plugin before 3.1.8 helps you to easily export WooCommerce order data. The tab parameter in the Admin Panel is vulnerable to reflected XSS.
The Link Whisper Free plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via the type parameter in all versions up to, and including, 0.8.8 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
This affects the package datatables.net before 1.11.3. If an array is passed to the HTML escape entities function it would not have its contents escaped.
NetVision Information ISOinsight has a Reflected Cross-site Scripting vulnerability, allowing unauthenticated remote attackers to execute arbitrary JavaScript code in the user's browser through phishing techniques.
A security vulnerability has been detected in JhumanJ OpnForm up to 1.9.3. Affected by this vulnerability is an unknown functionality of the file /show/submissions. The manipulation leads to cross site scripting. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used. The identifier of the patch is a2af1184e53953afa8cb052f4055f288adcaa608. To fix this issue, it is recommended to deploy a patch.
A vulnerability has been found in wangchenyi1996 chat_forum up to 80bdb92f5b460d36cab36e530a2c618acef5afd2. This impacts an unknown function of the file /q.php. Such manipulation of the argument path leads to cross site scripting. The attack may be launched remotely. This product operates on a rolling release basis, ensuring continuous delivery. Consequently, there are no version details for either affected or updated releases.
A security flaw has been discovered in MikeCen WeChat-Face-Recognition up to 6e3f72bf8547d80b59e330f1137e4aa505f492c1. This vulnerability affects the function valid of the file wx.php. The manipulation of the argument echostr results in cross site scripting. The attack can be launched remotely. This product does not use versioning. This is why information about affected and unaffected releases are unavailable. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been found in Gstarsoft GstarCAD up to 9.4.0. This affects an unknown function of the component File Renaming Handler. The manipulation leads to cross site scripting. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. Applying a patch is the recommended action to fix this issue.
A bug exist in the input parameter of Access Manager that allows supply of invalid character to trigger cross-site scripting vulnerability. This affects NetIQ Access Manager 4.5 and 5.0
A vulnerability was identified in Vanderlande Baggage 360 7.0.0. This issue affects some unknown processing of the file /api-addons/v1/messages. Such manipulation of the argument Message leads to cross site scripting. The attack may be performed from remote. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
This vulnerability is present in device_graph_page.php script, which is a part of the Advantech R-SeeNet web applications. A specially crafted URL by an attacker and visited by a victim can lead to arbitrary JavaScript code execution.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
A CWE-79: Improper Neutralization of Input During Web Page Generation (Cross-siteScripting) through Cross-Site Request Forgery (CSRF) vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server.
VMware Workspace one UEM console (2102 prior to 21.2.0.8, 2101 prior to 21.1.0.14, 2011 prior to 20.11.0.27, 2010 prior to 20.10.0.16,2008 prior to 20.8.0.28, 2007 prior to 20.7.0.14,2006 prior to 20.6.0.19, 2005 prior to 20.5.0.46, 2004 prior to 20.4.0.21, 2003 prior to 20.3.0.23, 2001 prior to 20.1.0.32, 1912 prior to 19.12.0.24) contain a cross-site scripting vulnerability. VMware Workspace ONE UEM console does not validate incoming requests during device enrollment after leading to rendering of unsanitized input on the user device in response.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
The vCenter Server contains a reflected cross-site scripting vulnerability due to a lack of input sanitization. An attacker may exploit this issue to execute malicious scripts by tricking a victim into clicking a malicious link.
A Reflected Cross-Site Scripting (XSS) vulnerability exists in SourceCodester Sales and Inventory System 1.0. The vulnerability is located in the index.php file via the "msg" parameter. The application fails to sanitize the input, allowing remote attackers to inject arbitrary web script or HTML via a crafted URL.
A weakness has been identified in PHPGurukul Cyber Cafe Management System 1.0. Affected by this vulnerability is an unknown functionality of the file /search.php of the component POST Parameter Handler. Executing a manipulation of the argument searchdata can lead to cross site scripting. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks.
Proofpoint Insider Threat Management Server (formerly ObserveIT Server) before 7.11.1 allows stored XSS.
Cross-site scripting (XSS) vulnerability in the Collne Welcart e-Commerce plugin before 1.8.3 for WordPress allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2016-4826.
Cross-site scripting (XSS) vulnerability in the Collne Welcart e-Commerce plugin before 1.8.3 for WordPress allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2016-4827.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
Bad validation logic in the Dart SDK versions prior to 2.12.3 allow an attacker to use an XSS attack via DOM clobbering. The validation logic in dart:html for creating DOM nodes from text did not sanitize properly when it came across template tags.
This vulnerability is present in device_graph_page.php script, which is a part of the Advantech R-SeeNet web applications. A specially crafted URL by an attacker and visited by a victim can lead to arbitrary JavaScript code execution.
Reflected XSS vulnerability in Micro Focus Application Automation Tools Plugin - Jenkins plugin. The vulnerability affects all version 6.7 and earlier versions.
A reflected cross-site script vulnerability in GitLab before versions 13.11.6, 13.12.6 and 14.0.2 allowed an attacker to send a malicious link to a victim and trigger actions on their behalf if they clicked it
Cross-site scripting vulnerabilities exist in the ssh_form.php script functionality of Advantech R-SeeNet v 2.4.12 (20.10.2020). If a user visits a specially crafted URL, it can lead to arbitrary JavaScript code execution in the context of the targeted user’s browser. An attacker can provide a crafted URL to trigger this vulnerability.