Due to missing authentication and input sanitization of code the EventLogServiceCollector of SAP Diagnostics Agent - version 720, allows an attacker to execute malicious scripts on all connected Diagnostics Agents running on Windows. On successful exploitation, the attacker can completely compromise confidentiality, integrity and availability of the system.
The User Email Verification for WooCommerce plugin for WordPress is vulnerable to authentication bypass via authenticate_user_by_email in versions up to, and including, 3.5.0. This is due to a random token generation weakness in the resend_verification_email function. This allows unauthenticated attackers to impersonate users and trigger an email address verification for arbitrary accounts, including administrative accounts, and automatically be logged in as that user, including any site administrators. This requires the Allow Automatic Login After Successful Verification setting to be enabled, which it is not by default.
The ClearPass Policy Manager web interface is affected by a vulnerability that leads to authentication bypass. Upon successful bypass an attacker could then execute an exploit that would allow to remote command execution in the underlying operating system. Resolution: Fixed in 6.7.13-HF, 6.8.5-HF, 6.8.6, 6.9.1 and higher.
Missing Authentication for Critical Function in SICK FX0-GPNT v3 Firmware Version V3.04 and V3.05 allows an unprivileged remote attacker to achieve arbitrary remote code execution via maliciously crafted RK512 commands to the listener on TCP port 9000.
A vulnerability, which was classified as critical, was found in MAXTECH MAX-G866ac 0.4.1_TBRO_20160314. This affects an unknown part of the component Remote Management. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227001 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). The supported version that is affected is 12.2.1.3.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in takeover of Oracle WebLogic Server. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
Undisclosed requests may bypass configuration utility authentication, allowing an attacker with network access to the BIG-IP system through the management port and/or self IP addresses to execute arbitrary system commands. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1026 and Application prior to version 20.0.2702 (VA deployments only) expose a set of unauthenticated REST API endpoints that return configuration files and clear‑text passwords. The same endpoints also disclose the Laravel APP_KEY used for cryptographic signing. Because the APP_KEY is required to generate valid signed requests, an attacker who obtains it can craft malicious payloads that are accepted by the application and achieve remote code execution on the appliance. This vulnerability has been identified by the vendor as: V-2024-018 — RCE & Leaks via API.
An information disclosure vulnerability exists in Ruijie NBR series routers (known to affect NBR2000G, NBR1300G, and NBR1000 models) via the /WEB_VMS/LEVEL15/ endpoint. By crafting a specific POST request with modified Cookie headers and specially formatted parameters, an unauthenticated attacker can retrieve administrative account credentials in plaintext. This flaw allows direct disclosure of sensitive user data due to improper authentication checks and insecure backend logic. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-05 UTC.
A vulnerability in the web-based management interface of Cisco SPA112 2-Port Phone Adapters could allow an unauthenticated, remote attacker to execute arbitrary code on an affected device. This vulnerability is due to a missing authentication process within the firmware upgrade function. An attacker could exploit this vulnerability by upgrading an affected device to a crafted version of firmware. A successful exploit could allow the attacker to execute arbitrary code on the affected device with full privileges. Cisco has not released firmware updates to address this vulnerability.
An unauthenticated arbitrary file read exists in LILIN Digital Video Recorder (DVR) devices prior to firmware version 2.0b60_20200207 via the /z/zbin/net_html.cgi endpoint. This vulnerability allows attackers to read sensitive configuration files, such as /zconf/service.xml, which can then be used to facilitate further attacks including command injection. The vulnerability has been exploited in the wild in conjunction with other issues by botnets like FBot and Moobot.
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1049 and Application prior to version 20.0.2786 (VA/SaaS deployments) contain a default admin account and an installation‑time endpoint at `/admin/query/update_database.php` that can be accessed without authentication. An attacker who can reach the installation web interface can POST arbitrary `root_user` and `root_password` values, causing the script to replace the default admin credentials with attacker‑controlled ones. The script also contains hard‑coded SHA‑512 and SHA‑1 hashes of the default password, allowing the attacker to bypass password‑policy validation. As a result, an unauthenticated remote attacker can obtain full administrative control of the system during the initial setup. This vulnerability has been identified by the vendor as: V-2024-022 — Insecure Installation Credentials.
authentik is an open-source Identity Provider. Prior to versions 2023.8.4 and 2023.10.2, when the default admin user has been deleted, it is potentially possible for an attacker to set the password of the default admin user without any authentication. authentik uses a blueprint to create the default admin user, which can also optionally set the default admin users' password from an environment variable. When the user is deleted, the `initial-setup` flow used to configure authentik after the first installation becomes available again. authentik 2023.8.4 and 2023.10.2 fix this issue. As a workaround, ensure the default admin user (Username `akadmin`) exists and has a password set. It is recommended to use a very strong password for this user, and store it in a secure location like a password manager. It is also possible to deactivate the user to prevent any logins as akadmin.
A missing authentication vulnerability in the GFIAgent component of GFI Kerio Control 9.4.5 allows unauthenticated remote attackers to perform privileged operations. The GFIAgent service, responsible for integration with GFI AppManager, exposes HTTP services on ports 7995 and 7996 without proper authentication. The /proxy handler on port 7996 allows arbitrary forwarding to administrative endpoints when provided with an Appliance UUID, which itself can be retrieved from port 7995. This results in a complete authentication bypass, permitting access to sensitive administrative APIs.
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1049 and Application prior to version 20.0.2786 (VA/SaaS deployments) expose internal Docker containers through the gw Docker instance. The gateway publishes a /meta endpoint which lists every micro‑service container together with version information. These containers are reachable directly over HTTP/HTTPS without any access‑control list (ACL), authentication or rate‑limiting. Consequently, any attacker on the LAN or the Internet can enumerate all internal services and their versions, interact with the exposed APIs of each microservice as an unauthenticated user, or issue malicious requests that may lead to information disclosure, privilege escalation within the container, or denial‑of‑service of the entire appliance. The root cause is the absence of authentication and network‑level restrictions on the API‑gateway’s proxy to internal Docker containers, effectively turning the internal service mesh into a public attack surface. This vulnerability has been identified by the vendor as: V-2024-030 — Exposed Internal Docker Instance (LAN).
A vulnerability classified as critical was found in SourceCodester Online Pizza Ordering System 1.0. Affected by this vulnerability is the function delete_category of the file ajax.php of the component POST Parameter Handler. The manipulation leads to missing authentication. The attack can be launched remotely. The associated identifier of this vulnerability is VDB-221455.
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code execution in the context of an administrator.
An unauthenticated remote attacker who is aware of a MQTT topic name can send and receive messages, including GET/SET configuration commands, reboot commands and firmware updates.
SnapCenter versions 4.7 prior to 4.7P2 and 4.8 prior to 4.8P1 are susceptible to a vulnerability which could allow a remote unauthenticated attacker to gain access as an admin user.
Victure PC530 devices allow unauthenticated TELNET access as root.
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior allows the execution of commands without credentials. As Telnet and file transfer protocol (FTP) are the only protocols available for device management, an unauthorized user could access the system and modify the device configuration, which could result in the unauthorized user executing unrestricted malicious commands.
NetAlertX is a network, presence scanner and alert framework. Prior to version 25.4.14, it is possible to bypass the authentication mechanism of NetAlertX to update settings without authentication. An attacker can trigger sensitive functions within util.php by sending crafted requests to /index.php. This issue has been patched in version 25.4.14.
An unauthenticated remote attacker can gain full access on the affected devices as they are shipped without a password by default and setting one is not enforced.
Langflow versions prior to 1.3.0 are susceptible to code injection in the /api/v1/validate/code endpoint. A remote and unauthenticated attacker can send crafted HTTP requests to execute arbitrary code.
Password recovery vulnerability in SICK SIM2000ST Partnumber 2086502 with firmware version <1.13.4 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.13.4 as soon as possible (available in SICK Support Portal).
A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T300 (with firmware 2.7 and older) that could cause a wide range of problems, including information exposure, denial of service, and command execution when access to a resource from an attacker is not restricted or incorrectly restricted.
Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.913 Application 20.0.2253 allows Addition of Partial Admin Users Without Authentication V-2024-002.
Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.933 Application 20.0.2368 allows Unauthenticated Driver Package Editing V-2024-008.
LightCMS v1.3.7 was discovered to contain a remote code execution (RCE) vulnerability via the image:make function.
authentik is an open-source identity provider. Versions prior to 2022.11.2 and 2022.10.2 are vulnerable to unauthorized user creation and potential account takeover. With the default flows, unauthenticated users can create new accounts in authentik. If a flow exists that allows for email-verified password recovery, this can be used to overwrite the email address of admin accounts and take over their accounts. authentik 2022.11.2 and 2022.10.2 fix this issue. As a workaround, a policy can be created and bound to the `default-user-settings-flow flow` with the contents `return request.user.is_authenticated`.
HGiga PowerStation has a vulnerability of Information Leakage. An unauthenticated remote attacker can exploit this vulnerability to obtain the administrator's credential. This credential can then be used to login PowerStation or Secure Shell to achieve remote code execution.
An issue discovered in Shenzhen Zhiboton Electronics ZBT WE1626 Router v 21.06.18 allows attackers to escalate privileges via WGET command to the Network Diagnosis endpoint.
An issue was discovered in Veritas NetBackup Flex Scale through 3.0 and Access Appliance through 8.0.100. Unauthenticated remote command execution can occur via the management portal.
KubeView through 0.1.31 allows attackers to obtain control of a Kubernetes cluster because api/scrape/kube-system does not require authentication, and retrieves certificate files that can be used for authentication as kube-admin. NOTE: the vendor's position is that KubeView was a "fun side project and a learning exercise," and not "very secure."
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/menu/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to edit user group permissions via crafted HTTP requests.
The Flexi Classic and Flexi Soft Gateways SICK UE410-EN3 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK UE410-EN1 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK UE410-EN3S04 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK UE410-EN4 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK FX0-GENT00000 FLEXISOFT EIP GATEW. with serial number <=2311xxxx with Firmware <=V2.11.0, SICK FX0-GMOD00000 FLEXISOFT MOD GATEW. with serial number <=2311xxxx with Firmware <=V2.11.0, SICK FX0-GPNT00000 FLEXISOFT PNET GATEW. with serial number <=2311xxxx with Firmware <=V2.12.0, SICK FX0-GENT00030 FLEXISOFT EIP GATEW.V2 with serial number <=2311xxxx all Firmware versions, SICK FX0-GPNT00030 FLEXISOFT PNET GATEW.V2 with serial number <=2311xxxx all Firmware versions and SICK FX0-GMOD00010 FLEXISOFT MOD GW with serial number <=2311xxxx with Firmware <=V2.11.0 all have Telnet enabled by factory default. No password is set in the default configuration.
A CWE-306 "Missing Authentication for Critical Function" in maxtime/handleRoute.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to affect the device confidentiality, integrity, or availability in multiple unspecified ways via crafted HTTP requests.
Even if the authentication fails for local service authentication, the requested command could still execute regardless of authentication status.
The default configuration of Lazy Mouse does not require a password, allowing remote unauthenticated users to execute arbitrary code with no prior authorization or authentication. CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
In the default configuration of Apache SOAP, an RPCRouterServlet is available without authentication. This gives an attacker the possibility to invoke methods on the classpath that meet certain criteria. Depending on what classes are available on the classpath this might even lead to arbitrary remote code execution. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
An issue was discovered in BACKCLICK Professional 5.9.63. User authentication for accessing the CORBA back-end services can be bypassed.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p0_3.2.2.17p0_4.7p0. Direct access to the API is possible on TCP port 8888 via programs located in the cgi-bin folder without any authentication.
PC Keyboard allows remote unauthenticated users to send instructions to the server to execute arbitrary code without any previous authorization or authentication. CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API. The vulnerability allows an unauthenticated attacker to read and set several device parameters that can lead to full compromise of the device.
The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise.
Telepad allows remote unauthenticated users to send instructions to the server to execute arbitrary code without any previous authorization or authentication. CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
An issue was discovered in BACKCLICK Professional 5.9.63. Due to exposed CORBA management services, arbitrary system commands can be executed on the server.
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to create users on the PLC. This could allow an attacker to create and use an account with elevated privileges and take control of the device.
Web page which "wizardpwd.asp" ALLNET Router model WR0500AC is prone to Authorization bypass vulnerability – the password, located at "admin" allows changing the http[s]://wizardpwd.asp/cgi-bin. Does not validate the user's identity and can be accessed publicly.