CVE-2023-38075

Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-12 Sep, 2023 | 09:32
Updated At-02 Aug, 2024 | 17:30
Rejected At-
Credits

A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20842)

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:12 Sep, 2023 | 09:32
Updated At:02 Aug, 2024 | 17:30
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20842)

Affected Products
Vendor
Siemens AGSiemens
Product
JT2Go
Default Status
unknown
Versions
Affected
  • All versions < V14.3.0.1
Vendor
Siemens AGSiemens
Product
Teamcenter Visualization V13.3
Default Status
unknown
Versions
Affected
  • All versions < V13.3.0.12
Vendor
Siemens AGSiemens
Product
Teamcenter Visualization V14.0
Default Status
unknown
Versions
Affected
  • All versions
Vendor
Siemens AGSiemens
Product
Teamcenter Visualization V14.1
Default Status
unknown
Versions
Affected
  • All versions < V14.1.0.11
Vendor
Siemens AGSiemens
Product
Teamcenter Visualization V14.2
Default Status
unknown
Versions
Affected
  • All versions < V14.2.0.6
Vendor
Siemens AGSiemens
Product
Teamcenter Visualization V14.3
Default Status
unknown
Versions
Affected
  • All versions < V14.3.0.1
Vendor
Siemens AGSiemens
Product
Tecnomatix Plant Simulation V2201
Default Status
unknown
Versions
Affected
  • All versions < V2201.0010
Vendor
Siemens AGSiemens
Product
Tecnomatix Plant Simulation V2302
Default Status
unknown
Versions
Affected
  • All versions < V2302.0004
Problem Types
TypeCWE IDDescription
CWECWE-416CWE-416: Use After Free
Type: CWE
CWE ID: CWE-416
Description: CWE-416: Use After Free
Metrics
VersionBase scoreBase severityVector
3.17.8HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C
Version: 3.1
Base score: 7.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf
N/A
https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf
N/A
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf
Resource: N/A
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf
Resource: N/A
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf
x_transferred
https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf
Resource:
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf
Resource:
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:12 Sep, 2023 | 10:15
Updated At:25 Jan, 2024 | 02:23

A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20842)

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.17.8HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Secondary3.17.8HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 7.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 7.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CPE Matches

Siemens AG
siemens
>>jt2go>>Versions before 14.3.0.1(exclusive)
cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>teamcenter_visualization>>Versions from 13.3.0(inclusive) to 13.4.0.12(exclusive)
cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>teamcenter_visualization>>Versions from 14.0(inclusive) to 14.1.0.11(exclusive)
cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>teamcenter_visualization>>Versions from 14.2(inclusive) to 14.2.0.6(exclusive)
cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>teamcenter_visualization>>Versions from 14.3(inclusive) to 14.3.0.1(exclusive)
cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>tecnomatix_plant_simulation>>Versions from 2201.0(inclusive) to 2201.0010(exclusive)
cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>tecnomatix_plant_simulation>>Versions from 2302.0(inclusive) to 2302.0004(exclusive)
cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-416Primaryproductcert@siemens.com
CWE ID: CWE-416
Type: Primary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdfproductcert@siemens.com
Vendor Advisory
https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdfproductcert@siemens.com
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdf
Source: productcert@siemens.com
Resource:
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdf
Source: productcert@siemens.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

1210Records found

CVE-2021-44435
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.85% / 74.55%
||
7 Day CHG~0.00%
Published-14 Dec, 2021 | 12:06
Updated-04 Aug, 2024 | 04:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to stack based buffer overflow while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14903)

Action-Not Available
Vendor-Siemens AG
Product-jt_utilitiesjt_open_toolkitJTTKJT Utilities
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-35207
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.5||HIGH
EPSS-0.33% / 55.19%
||
7 Day CHG~0.00%
Published-11 Jun, 2024 | 11:15
Updated-06 Aug, 2024 | 15:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery(CSRF) attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user.

Action-Not Available
Vendor-Siemens AG
Product-sinec_traffic_analyzerSINEC Traffic Analyzersinec_traffic_analyzer
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)
CVE-2021-42028
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.04% / 12.38%
||
7 Day CHG~0.00%
Published-04 Jan, 2024 | 11:20
Updated-17 Jun, 2025 | 20:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14860)

Action-Not Available
Vendor-Siemens AGSiemens Medical Solutions USA, Inc.
Product-syngo_fastviewsyngo fastView
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-42024
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.33%
||
7 Day CHG~0.00%
Published-14 Dec, 2021 | 12:06
Updated-04 Aug, 2024 | 03:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter STAR-CCM+ Viewer (All versions < 2021.3.1). The starview+.exe application lacks proper validation of user-supplied data when parsing scene files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-simcenter_star-ccm\+_viewerSimcenter STAR-CCM+ Viewer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-40367
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.05% / 15.67%
||
7 Day CHG~0.00%
Published-04 Jan, 2024 | 11:20
Updated-17 Jun, 2025 | 20:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing DICOM files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15097)

Action-Not Available
Vendor-Siemens AGSiemens Medical Solutions USA, Inc.
Product-syngo_fastviewsyngo fastView
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-39134
Matching Score-8
Assigner-GitHub, Inc.
ShareView Details
Matching Score-8
Assigner-GitHub, Inc.
CVSS Score-8.2||HIGH
EPSS-1.29% / 79.33%
||
7 Day CHG~0.00%
Published-31 Aug, 2021 | 16:55
Updated-04 Aug, 2024 | 01:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
UNIX Symbolic Link (Symlink) Following in @npmcli/arborist

`@npmcli/arborist`, the library that calculates dependency trees and manages the `node_modules` folder hierarchy for the npm command line interface, aims to guarantee that package dependency contracts will be met, and the extraction of package contents will always be performed into the expected folder. This is, in part, accomplished by resolving dependency specifiers defined in `package.json` manifests for dependencies with a specific name, and nesting folders to resolve conflicting dependencies. When multiple dependencies differ only in the case of their name, Arborist's internal data structure saw them as separate items that could coexist within the same level in the `node_modules` hierarchy. However, on case-insensitive file systems (such as macOS and Windows), this is not the case. Combined with a symlink dependency such as `file:/some/path`, this allowed an attacker to create a situation in which arbitrary contents could be written to any location on the filesystem. For example, a package `pwn-a` could define a dependency in their `package.json` file such as `"foo": "file:/some/path"`. Another package, `pwn-b` could define a dependency such as `FOO: "file:foo.tgz"`. On case-insensitive file systems, if `pwn-a` was installed, and then `pwn-b` was installed afterwards, the contents of `foo.tgz` would be written to `/some/path`, and any existing contents of `/some/path` would be removed. Anyone using npm v7.20.6 or earlier on a case-insensitive filesystem is potentially affected. This is patched in @npmcli/arborist 2.8.2 which is included in npm v7.20.7 and above.

Action-Not Available
Vendor-npmjsnpmOracle CorporationSiemens AG
Product-sinec_infrastructure_network_servicesarboristnpmgraalvmarborist
CWE ID-CWE-61
UNIX Symbolic Link (Symlink) Following
CWE ID-CWE-178
Improper Handling of Case Sensitivity
CVE-2021-38405
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.08% / 23.50%
||
7 Day CHG~0.00%
Published-21 Nov, 2023 | 18:19
Updated-04 Aug, 2024 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Siemens Solid Edge, JT2Go, and Teamcenter Visualization Improper Restriction of Operations within the Bounds of a Memory Buffer

The Datalogics APDFL library used in affected products is vulnerable to memory corruption condition while parsing specially crafted PDF files. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-34297
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.33%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13059)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-787
Out-of-bounds Write
CWE ID-CWE-20
Improper Input Validation
CVE-2021-34316
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.33%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The DL180CoolType.dll library in affected applications lacks proper validation of user-supplied data when parsing PDF files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13380)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-787
Out-of-bounds Write
CWE ID-CWE-20
Improper Input Validation
CVE-2021-34305
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.46% / 63.81%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13340)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-787
Out-of-bounds Write
CWE ID-CWE-20
Improper Input Validation
CVE-2021-34292
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.33%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12959)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-125
Out-of-bounds Read
CWE ID-CWE-20
Improper Input Validation
CVE-2021-34310
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.33%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13351)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-787
Out-of-bounds Write
CWE ID-CWE-20
Improper Input Validation
CVE-2021-34329
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.45% / 63.11%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Solid Edge SE2021 (All Versions < SE2021MP5), Teamcenter Visualization (All versions < V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13427)

Action-Not Available
Vendor-Siemens AG
Product-jt2gosolid_edgeteamcenter_visualizationJT2GoSolid Edge SE2021Teamcenter Visualization
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-34314
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.33%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing SGI files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13355)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-787
Out-of-bounds Write
CWE ID-CWE-20
Improper Input Validation
CVE-2021-34326
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.45% / 63.11%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Solid Edge SE2021 (All Versions < SE2021MP5), Teamcenter Visualization (All versions < V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13422)

Action-Not Available
Vendor-Siemens AG
Product-jt2gosolid_edgeteamcenter_visualizationJT2GoSolid Edge SE2021Teamcenter Visualization
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-34294
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.33%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13023

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-125
Out-of-bounds Read
CWE ID-CWE-20
Improper Input Validation
CVE-2021-34318
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.40% / 60.49%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing PCT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13403)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-787
Out-of-bounds Write
CWE ID-CWE-20
Improper Input Validation
CVE-2021-34313
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.40% / 60.49%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13354)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-34296
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.33%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13057)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-125
Out-of-bounds Read
CWE ID-CWE-20
Improper Input Validation
CVE-2021-34323
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.33%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13419)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-787
Out-of-bounds Write
CWE ID-CWE-20
Improper Input Validation
CVE-2021-34315
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.33%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing SGI files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13356)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-125
Out-of-bounds Read
CWE ID-CWE-20
Improper Input Validation
CVE-2021-37180
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.38% / 59.00%
||
7 Day CHG~0.00%
Published-10 Aug, 2021 | 10:35
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). The PSKERNEL.dll library lacks proper validation while parsing user-supplied OBJ files that could cause an out of bounds access to an uninitialized pointer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13775)

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2021solid_edge_se2021_firmwareSolid Edge SE2021
CWE ID-CWE-824
Access of Uninitialized Pointer
CVE-2025-30033
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.5||HIGH
EPSS-0.01% / 0.54%
||
7 Day CHG-0.01%
Published-12 Aug, 2025 | 11:16
Updated-10 Feb, 2026 | 09:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.

Action-Not Available
Vendor-Siemens AG
Product-SIMATIC Control Function Library (CFL) V3.xSIMATIC WinCC Runtime AdvancedSIMATIC Control Function Library (CFL) V1.xSIMATIC PCS 7 MPC ConfiguratorSIMATIC MTP CREATOR V4.xSIMATIC S7-PLCSIM V18MultiFieldbus Configuration Tool (MFCT)SIMATIC eaSie PCS 7 Skill PackageSIMATIC WinCC Runtime ProfessionalSIMATIC eaSie Workflow SkillsSIMATIC STEP 7 CFC V19SIMATIC Process Historian 2020SIMATIC ProSave V19SIMATIC eaSie Document SkillsSIMATIC S7-Fail-safe Configuration Tool (S7-FCT)Totally Integrated Automation Portal (TIA Portal) V20SIMATIC NET PC Software V18SIMATIC WinCC Visualization Architect (SiVArc) V20SIMATIC WinCC Runtime Professional V20SIMATIC WinCC V7.5SIMATIC PCS 7 Industry Library V9.0TIA Portal Cloud ConnectorSIMATIC ProSave V18SIMIT Rapid TesterSIMATIC Process Function Library (PFL) V4.0SIMATIC MTP Integrator V2.xSIMATIC PCS neo V5.0SINAMICS Startdrive V20SIMATIC PCS 7 PowerControlCreate MyConfig (CMC)SIMATIC PCS 7 Logic Matrix V10.0SIMATIC NET PC Software V17CP PtP Param configuring interfaceSIMATIC ProSave V17SIMATIC PCS 7 Basis Library V9.1SIMATIC MTP Integrator V1.xSIMATIC Management ConsoleSIMATIC PCS 7 V10.0Automation License Manager V6.2SIMATIC BATCH V10.0SIMATIC ProSave V20SIMATIC WinCC Visualization Architect (SiVArc) V19Modular PID CTRL ToolSIMATIC PCS 7 Advanced Process Functions V2.2SIMATIC WinCC Unified Line CoordinationSIMATIC PCS 7 Standard Chemical Library V9.1SIMATIC MTP CREATOR V5.xTotally Integrated Automation Portal (TIA Portal) V19SIMATIC PDM V9.2SIMATIC PDM Maintenance Station V5.0SIMATIC Safety MatrixCEMAT V10.0SIMATIC S7 F Systems V6.3SIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0SIMATIC PCS 7 Logic Matrix V9.1TIA Portal Test Suite V20SIMIT Simulation PlatformSIMATIC Process Historian 2024SIMATIC WinCC V8.0SIMATIC Energy Suite V19SIMATIC WinCC Unified PC Runtime V18TIA Project-ServerOpenPCS 7 V10.0SIMATIC PDM V9.3SIMATIC WinCC Unified SequenceSIMATIC WinCC Visualization Architect (SiVArc) V17TIA Portal Test Suite V17SIMATIC S7-PLCSIM V19SIMATIC D7-SYSSIMATIC Control Function Library (CFL) V2.xAutomation License Manager V6.0SINAMICS Startdrive V19SIMATIC Logon V1.6SIMATIC PCS neo V6.0SIMATIC PCS 7 Industry Library V9.1SIMATIC Automation ToolSIMATIC S7-PLCSIM V17SITRANSTIA AdministratorSIMATIC NET PC Software V19SIMATIC NET PC Software V20SIMATIC WinCC TeleControlSIMATIC S7-1500 Software Controller V3SIMATIC PCS 7 TeleControlSINAMICS Startdrive V18SIMATIC PCS 7 V9.1SIMATIC Route Control V9.1SIMATIC BATCH V9.1SIMATIC PCS 7 Advanced Process Faceplates V9.1SIMATIC WinCC Visualization Architect (SiVArc) V18SIMATIC STEP 7 CFC V20WinCC Panel Image SetupSIMATIC MTP CREATOR V2.xSIMATIC ODK 1500SSIMATIC TargetSIMATIC STEP 7 V5.7SIMATIC S7-1500 Software Controller V2SINAMICS Startdrive V17SIMATIC PCS 7 Advanced Process Graphics V9.1OpenPCS 7 V9.1SIMATIC Energy Suite V18SIMATIC S7-PCTSIMATIC Logon V2.0FM Configuration PackageSIMATIC PCS 7 Advanced Process Graphics V10.0Energy Support Library (EnSL)SIMATIC WinCC V8.1SIMATIC PCS 7 Basis Library V10.0SIMATIC PCS 7 Advanced Process Library V9.1SINEMA Remote Connect ClientSIMATIC Control Function Library (CFL) V4.xSIMATIC PCS 7 Basis Faceplates V9.1TeleControl Server Basic V3.1Standard PID CTRL ToolSIMATIC Automation Tool SDK WindowsSIMATIC MTP CREATOR V3.xSIMATIC Management AgentTIA Project-Server V17Totally Integrated Automation Portal (TIA Portal) V17SIMATIC S7-PLCSIM V20SIMATIC PCS 7 Standard Chemical Library V10.0Siemens Network Planner (SINETPLAN)SIMATIC WinCC flexible ESSIMATIC Energy Suite V17SIMATIC WinCC Unified PC Runtime V19TIA Portal Test Suite V19Totally Integrated Automation Portal (TIA Portal) V18SIMATIC NET PC Software V16SIMATIC Process Historian 2022SIMATIC PCS 7 Industry Library V10.0SIMATIC PCS 7/OPEN OS V9.1SIMATIC Route Control V10.0SIMATIC S7-PLCSIM AdvancedSIMATIC S7 F Systems V6.4SIMATIC WinCC Unified PC Runtime V20SIMATIC eaSie Core PackageSINEC NMSSIMATIC PCS 7 Advanced Process Functions V2.1TIA Portal Test Suite V18
CWE ID-CWE-427
Uncontrolled Search Path Element
CVE-2025-27438
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.03% / 8.82%
||
7 Day CHG~0.00%
Published-11 Mar, 2025 | 09:48
Updated-23 Sep, 2025 | 15:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-teamcenter_visualizationtecnomatix_plant_simulationTeamcenter Visualization V2406Teamcenter Visualization V2412Teamcenter Visualization V2312Tecnomatix Plant Simulation V2404Teamcenter Visualization V14.3Tecnomatix Plant Simulation V2302
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-27496
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.30% / 52.72%
||
7 Day CHG~0.00%
Published-27 May, 2021 | 15:27
Updated-03 Aug, 2024 | 21:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior lack proper validation of user-supplied data when parsing PRT files. This could lead to pointer dereferences of a value obtained from an untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-datakitluxionn/aSiemens AG
Product-solid_edge_se2021solid_edge_se2020_firmwarekeyshotsolid_edge_se2021_firmwaresolid_edge_se2020crosscadwareDatakit Software libraries embedded in Luxion KeyShot software
CWE ID-CWE-822
Untrusted Pointer Dereference
CVE-2021-27382
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.67% / 70.90%
||
7 Day CHG~0.00%
Published-22 Apr, 2021 | 20:42
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13040)

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2021solid_edge_se2020Solid Edge SE2021Solid Edge SE2020
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-27381
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.33%
||
7 Day CHG~0.00%
Published-15 Mar, 2021 | 17:03
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP3). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534)

Action-Not Available
Vendor-Siemens AG
Product-solid_edgeSolid Edge SE2021Solid Edge SE2020
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-27387
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.40% / 60.49%
||
7 Day CHG~0.00%
Published-08 Jun, 2021 | 19:47
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap 2020.2 (All versions < V2020.2.MP3), Simcenter Femap 2021.1 (All versions < V2021.1.MP3). The femap.exe application lacks proper validation of user-supplied data when parsing FEMAP files. This could result in an out of bounds write past the end of an allocated structure, a different vulnerability than CVE-2021-27399. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12819)

Action-Not Available
Vendor-Siemens AG
Product-simcenter_femapSimcenter Femap 2020.2Simcenter Femap 2021.1
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-27397
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.38% / 59.00%
||
7 Day CHG~0.00%
Published-12 May, 2021 | 13:18
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13287)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-27398
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.94% / 75.80%
||
7 Day CHG~0.00%
Published-12 May, 2021 | 13:18
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27396. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13290)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-35303
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.14% / 33.40%
||
7 Day CHG~0.00%
Published-11 Jun, 2024 | 11:15
Updated-02 Aug, 2024 | 03:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0012), Tecnomatix Plant Simulation V2404 (All versions < V2404.0001). The affected applications contain a type confusion vulnerability while parsing specially crafted MODEL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22958)

Action-Not Available
Vendor-Siemens AG
Product-Tecnomatix Plant Simulation V2404Tecnomatix Plant Simulation V2302
CWE ID-CWE-704
Incorrect Type Conversion or Cast
CVE-2021-27390
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.37% / 58.21%
||
7 Day CHG~0.00%
Published-08 Jun, 2021 | 19:47
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.1.0.3), Teamcenter Visualization (All versions < V13.1.0.3). The TIFF_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13131)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-27380
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.36% / 57.52%
||
7 Day CHG~0.00%
Published-15 Mar, 2021 | 17:03
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)

Action-Not Available
Vendor-Siemens AG
Product-solid_edgeSolid Edge SE2021Solid Edge SE2020
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-27488
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.30% / 52.72%
||
7 Day CHG~0.00%
Published-27 May, 2021 | 15:37
Updated-03 Aug, 2024 | 21:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior lack proper validation of user-supplied data when parsing CATPart files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-datakitluxionn/aSiemens AG
Product-solid_edge_se2021solid_edge_se2020_firmwarekeyshotsolid_edge_se2021_firmwaresolid_edge_se2020crosscadwareDatakit Software libraries embedded in Luxion KeyShot software
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-27490
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.30% / 52.72%
||
7 Day CHG~0.00%
Published-27 May, 2021 | 16:08
Updated-03 Aug, 2024 | 21:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.

Action-Not Available
Vendor-datakitluxionn/aSiemens AG
Product-solid_edge_se2021solid_edge_se2020_firmwarekeyshotsolid_edge_se2021_firmwaresolid_edge_se2020crosscadwareDatakit Software libraries embedded in Luxion KeyShot software
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-27494
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.62% / 69.55%
||
7 Day CHG~0.00%
Published-27 May, 2021 | 15:26
Updated-03 Aug, 2024 | 21:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior lack proper validation of user-supplied data when parsing STP files. This could result in a stack-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-datakitluxionn/aSiemens AG
Product-solid_edge_se2021solid_edge_se2020_firmwarekeyshotsolid_edge_se2021_firmwaresolid_edge_se2020crosscadwareDatakit Software libraries embedded in Luxion KeyShot software
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2021-27399
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.40% / 60.49%
||
7 Day CHG~0.00%
Published-08 Jun, 2021 | 19:47
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap 2020.2 (All versions < V2020.2.MP3), Simcenter Femap 2021.1 (All versions < V2021.1.MP3). The femap.exe application lacks proper validation of user-supplied data when parsing FEMAP files. This could result in an out of bounds write past the end of an allocated structure, a different vulnerability than CVE-2021-27387. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12820)

Action-Not Available
Vendor-Siemens AG
Product-simcenter_femapSimcenter Femap 2020.2Simcenter Femap 2021.1
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-25665
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.40% / 60.49%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-03 Aug, 2024 | 20:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter STAR-CCM+ Viewer (All versions < V2021.2.1). The starview+.exe application lacks proper validation of user-supplied data when parsing scene files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13700)

Action-Not Available
Vendor-Siemens AG
Product-simcenter_star-ccm\+Simcenter STAR-CCM+ Viewer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-25670
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.37% / 58.21%
||
7 Day CHG~0.00%
Published-22 Apr, 2021 | 20:42
Updated-03 Aug, 2024 | 20:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix RobotExpert (All versions < V16.1). Affected applications lack proper validation of user-supplied data when parsing CELL files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12608)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_robotexpertTecnomatix RobotExpert
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-25175
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.03% / 8.13%
||
7 Day CHG~0.00%
Published-13 Mar, 2025 | 09:07
Updated-19 Aug, 2025 | 17:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap V2401 (All versions < V2401.0003), Simcenter Femap V2406 (All versions < V2406.0002). The affected application contains a memory corruption vulnerability while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25443)

Action-Not Available
Vendor-Siemens AG
Product-simcenter_femapSimcenter Femap V2406Simcenter Femap V2401
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-25178
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.67% / 70.87%
||
7 Day CHG~0.00%
Published-18 Jan, 2021 | 07:12
Updated-03 Aug, 2024 | 19:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A stack-based buffer overflow vulnerability exists when the recover operation is run with malformed .DXF and .DWG files. This can allow attackers to cause a crash potentially enabling a denial of service attack (Crash, Exit, or Restart) or possible code execution.

Action-Not Available
Vendor-opendesignn/aSiemens AG
Product-jt2gocomosdrawings_software_development_kitteamcenter_visualizationn/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-25174
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.40% / 59.91%
||
7 Day CHG~0.00%
Published-18 Jan, 2021 | 07:14
Updated-03 Aug, 2024 | 19:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Open Design Alliance Drawings SDK before 2021.12. A memory corruption vulnerability exists when reading malformed DGN files. It can allow attackers to cause a crash, potentially enabling denial of service (Crash, Exit, or Restart).

Action-Not Available
Vendor-opendesignn/aSiemens AG
Product-jt2gocomosdrawings_software_development_kitteamcenter_visualizationn/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-34085
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.18% / 40.27%
||
7 Day CHG~0.00%
Published-14 May, 2024 | 10:03
Updated-03 Oct, 2025 | 19:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V2312.0001), Teamcenter Visualization V14.1 (All versions < V14.1.0.13), Teamcenter Visualization V14.2 (All versions < V14.2.0.10), Teamcenter Visualization V14.3 (All versions < V14.3.0.7), Teamcenter Visualization V2312 (All versions < V2312.0001). The affected applications contain a stack overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationTeamcenter Visualization V2312Teamcenter Visualization V14.1JT2GoTeamcenter Visualization V14.2Teamcenter Visualization V14.3jt2goteamcenter_visualization
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2021-22921
Matching Score-8
Assigner-HackerOne
ShareView Details
Matching Score-8
Assigner-HackerOne
CVSS Score-7.8||HIGH
EPSS-0.41% / 60.77%
||
7 Day CHG~0.00%
Published-12 Jul, 2021 | 10:22
Updated-30 Apr, 2025 | 22:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Node.js before 16.4.1, 14.17.2, and 12.22.2 is vulnerable to local privilege escalation attacks under certain conditions on Windows platforms. More specifically, improper configuration of permissions in the installation directory allows an attacker to perform two different escalation attacks: PATH and DLL hijacking.

Action-Not Available
Vendor-Node.js (OpenJS Foundation)Siemens AGMicrosoft Corporation
Product-sinec_infrastructure_network_serviceswindowsnode.jsNode
CWE ID-CWE-732
Incorrect Permission Assignment for Critical Resource
CVE-2021-22651
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-1.71% / 82.03%
||
7 Day CHG~0.00%
Published-23 Feb, 2021 | 17:45
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

When loading a specially crafted file, Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 are, while processing the extraction of temporary files, suffering from a directory traversal vulnerability, which allows an attacker to store arbitrary scripts into automatic startup folders.

Action-Not Available
Vendor-luxionn/aSiemens AG
Product-solid_edge_se2021solid_edge_se2020_firmwarekeyshotsolid_edge_se2021_firmwaresolid_edge_se2020keyvrkeyshot_network_renderingkeyshot_viewerLuxion KeyVRLuxion KeyShot Network RenderingLuxion KeyShot ViewerLuxion KeyShot versions
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-22643
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.35% / 57.14%
||
7 Day CHG~0.00%
Published-23 Feb, 2021 | 03:13
Updated-03 Aug, 2024 | 18:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 are vulnerable to an out-of-bounds read while processing project files, which may allow an attacker to execute arbitrary code.

Action-Not Available
Vendor-luxionn/aSiemens AG
Product-solid_edge_se2021solid_edge_se2020_firmwarekeyshotsolid_edge_se2021_firmwaresolid_edge_se2020keyvrkeyshot_network_renderingkeyshot_viewerLuxion KeyShotLuxion KeyVRLuxion KeyShot Network RenderingLuxion KeyShot Viewer
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-22647
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.37% / 58.21%
||
7 Day CHG~0.00%
Published-23 Feb, 2021 | 03:13
Updated-03 Aug, 2024 | 18:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 are vulnerable to multiple out-of-bounds write issues while processing project files, which may allow an attacker to execute arbitrary code.

Action-Not Available
Vendor-luxionn/aSiemens AG
Product-solid_edge_se2021solid_edge_se2020_firmwarekeyshotsolid_edge_se2021_firmwaresolid_edge_se2020keyvrkeyshot_network_renderingkeyshot_viewerLuxion KeyShotLuxion KeyVRLuxion KeyShot Network RenderingLuxion KeyShot Viewer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-22645
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.25% / 48.19%
||
7 Day CHG~0.00%
Published-23 Feb, 2021 | 03:02
Updated-03 Aug, 2024 | 18:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 are vulnerable to an attack because the .bip documents display a “load” command, which can be pointed to a .dll from a remote network share. As a result, the .dll entry point can be executed without sufficient UI warning.

Action-Not Available
Vendor-luxionn/aSiemens AG
Product-solid_edge_se2021solid_edge_se2020_firmwarekeyshotsolid_edge_se2021_firmwaresolid_edge_se2020keyvrkeyshot_network_renderingkeyshot_viewerLuxion KeyShotLuxion KeyVRLuxion KeyShot Network RenderingLuxion KeyShot Viewer
CWE ID-CWE-357
Insufficient UI Warning of Dangerous Operations
CVE-2021-22663
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.41% / 60.60%
||
7 Day CHG~0.00%
Published-09 Feb, 2021 | 16:19
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Cscape (All versions prior to 9.90 SP3.5) lacks proper validation of user-supplied data when parsing project files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-hornerautomationn/aSiemens AG
Product-cscapeCscape
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-22649
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.33% / 55.53%
||
7 Day CHG~0.00%
Published-23 Feb, 2021 | 03:02
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 have multiple NULL pointer dereference issues while processing project files, which may allow an attacker to execute arbitrary code.

Action-Not Available
Vendor-luxionn/aSiemens AG
Product-solid_edge_se2021solid_edge_se2020_firmwarekeyshotsolid_edge_se2021_firmwaresolid_edge_se2020keyvrkeyshot_network_renderingkeyshot_viewerLuxion KeyShotLuxion KeyVRLuxion KeyShot Network RenderingLuxion KeyShot Viewer
CWE ID-CWE-822
Untrusted Pointer Dereference
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • ...
  • 24
  • 25
  • Next
Details not found