Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-28 Jul, 2011 | 18:00
Updated At-06 Aug, 2024 | 23:15
Rejected At-
Credits

Unspecified vulnerability in Rockwell Automation FactoryTalk Diagnostics Viewer before V2.30.00 (CPR9 SR3) allows local users to execute arbitrary code via a crafted FactoryTalk Diagnostics Viewer (.ftd) configuration file, which triggers memory corruption.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:28 Jul, 2011 | 18:00
Updated At:06 Aug, 2024 | 23:15
Rejected At:
▼CVE Numbering Authority (CNA)

Unspecified vulnerability in Rockwell Automation FactoryTalk Diagnostics Viewer before V2.30.00 (CPR9 SR3) allows local users to execute arbitrary code via a crafted FactoryTalk Diagnostics Viewer (.ftd) configuration file, which triggers memory corruption.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://rockwellautomation.custhelp.com/app/answers/detail/a_id/448424
x_refsource_MISC
http://www.securityfocus.com/bid/48962
vdb-entry
x_refsource_BID
http://www.us-cert.gov/control_systems/pdf/ICSA-11-175-01.pdf
x_refsource_MISC
Hyperlink: http://rockwellautomation.custhelp.com/app/answers/detail/a_id/448424
Resource:
x_refsource_MISC
Hyperlink: http://www.securityfocus.com/bid/48962
Resource:
vdb-entry
x_refsource_BID
Hyperlink: http://www.us-cert.gov/control_systems/pdf/ICSA-11-175-01.pdf
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://rockwellautomation.custhelp.com/app/answers/detail/a_id/448424
x_refsource_MISC
x_transferred
http://www.securityfocus.com/bid/48962
vdb-entry
x_refsource_BID
x_transferred
http://www.us-cert.gov/control_systems/pdf/ICSA-11-175-01.pdf
x_refsource_MISC
x_transferred
Hyperlink: http://rockwellautomation.custhelp.com/app/answers/detail/a_id/448424
Resource:
x_refsource_MISC
x_transferred
Hyperlink: http://www.securityfocus.com/bid/48962
Resource:
vdb-entry
x_refsource_BID
x_transferred
Hyperlink: http://www.us-cert.gov/control_systems/pdf/ICSA-11-175-01.pdf
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:28 Jul, 2011 | 18:55
Updated At:11 Apr, 2025 | 00:51

Unspecified vulnerability in Rockwell Automation FactoryTalk Diagnostics Viewer before V2.30.00 (CPR9 SR3) allows local users to execute arbitrary code via a crafted FactoryTalk Diagnostics Viewer (.ftd) configuration file, which triggers memory corruption.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary2.06.9MEDIUM
AV:L/AC:M/Au:N/C:C/I:C/A:C
Type: Primary
Version: 2.0
Base score: 6.9
Base severity: MEDIUM
Vector:
AV:L/AC:M/Au:N/C:C/I:C/A:C
CPE Matches

Rockwell Automation, Inc.
rockwellautomation
>>factorytalk_diagnostics_viewer>>Versions up to 2.10.02(inclusive)
cpe:2.3:a:rockwellautomation:factorytalk_diagnostics_viewer:*:*:*:*:*:*:*:*
Rockwell Automation, Inc.
rockwellautomation
>>factorytalk_diagnostics_viewer>>2.10
cpe:2.3:a:rockwellautomation:factorytalk_diagnostics_viewer:2.10:*:*:*:*:*:*:*
Rockwell Automation, Inc.
rockwellautomation
>>factorytalk_diagnostics_viewer>>2.10.01
cpe:2.3:a:rockwellautomation:factorytalk_diagnostics_viewer:2.10.01:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
NVD-CWE-noinfoPrimarynvd@nist.gov
CWE ID: NVD-CWE-noinfo
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
http://rockwellautomation.custhelp.com/app/answers/detail/a_id/448424cve@mitre.org
N/A
http://www.securityfocus.com/bid/48962cve@mitre.org
N/A
http://www.us-cert.gov/control_systems/pdf/ICSA-11-175-01.pdfcve@mitre.org
US Government Resource
http://rockwellautomation.custhelp.com/app/answers/detail/a_id/448424af854a3a-2127-422b-91ae-364da2661108
N/A
http://www.securityfocus.com/bid/48962af854a3a-2127-422b-91ae-364da2661108
N/A
http://www.us-cert.gov/control_systems/pdf/ICSA-11-175-01.pdfaf854a3a-2127-422b-91ae-364da2661108
US Government Resource
Hyperlink: http://rockwellautomation.custhelp.com/app/answers/detail/a_id/448424
Source: cve@mitre.org
Resource: N/A
Hyperlink: http://www.securityfocus.com/bid/48962
Source: cve@mitre.org
Resource: N/A
Hyperlink: http://www.us-cert.gov/control_systems/pdf/ICSA-11-175-01.pdf
Source: cve@mitre.org
Resource:
US Government Resource
Hyperlink: http://rockwellautomation.custhelp.com/app/answers/detail/a_id/448424
Source: af854a3a-2127-422b-91ae-364da2661108
Resource: N/A
Hyperlink: http://www.securityfocus.com/bid/48962
Source: af854a3a-2127-422b-91ae-364da2661108
Resource: N/A
Hyperlink: http://www.us-cert.gov/control_systems/pdf/ICSA-11-175-01.pdf
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
US Government Resource

Change History

0
Information is not available yet

Similar CVEs

5Records found

CVE-2016-2277
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.3||MEDIUM
EPSS-0.01% / 0.68%
||
7 Day CHG~0.00%
Published-06 Apr, 2016 | 23:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IAB.exe in Rockwell Automation Integrated Architecture Builder (IAB) before 9.6.0.8 and 9.7.x before 9.7.0.2 allows remote attackers to execute arbitrary code via a crafted project file.

Action-Not Available
Vendor-n/aRockwell Automation, Inc.
Product-integrated_architecture_buildern/a
CWE ID-CWE-284
Improper Access Control
CVE-2014-9209
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.9||MEDIUM
EPSS-0.01% / 0.50%
||
7 Day CHG-0.00%
Published-31 Mar, 2015 | 01:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Untrusted search path vulnerability in the Clean Utility application in Rockwell Automation FactoryTalk Services Platform before 2.71.00 and FactoryTalk View Studio 8.00.00 and earlier allows local users to gain privileges via a Trojan horse DLL in an unspecified directory.

Action-Not Available
Vendor-n/aRockwell Automation, Inc.
Product-factorytalk_services_platformfactorytalk_view_studion/a
CVE-2014-9204
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.9||MEDIUM
EPSS-0.03% / 6.03%
||
7 Day CHG~0.00%
Published-17 May, 2015 | 01:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Stack-based buffer overflow in OPCTest.exe in Rockwell Automation RSLinx Classic before 3.73.00 allows remote attackers to execute arbitrary code via a crafted CSV file.

Action-Not Available
Vendor-n/aRockwell Automation, Inc.
Product-rslinxn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2014-0755
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.9||MEDIUM
EPSS-0.00% / 0.13%
||
7 Day CHG~0.00%
Published-05 Feb, 2014 | 02:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Rockwell Automation RSLogix 5000 7 through 20.01, and 21.0, does not properly implement password protection for .ACD files (aka project files), which allows local users to obtain sensitive information or modify data via unspecified vectors.

Action-Not Available
Vendor-n/aRockwell Automation, Inc.
Product-logix_5000_controllerrslogix_5000_design_and_configuration_softwaren/a
CVE-2021-27473
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.1||MEDIUM
EPSS-0.00% / 0.08%
||
7 Day CHG~0.00%
Published-23 Mar, 2022 | 19:46
Updated-16 Apr, 2025 | 16:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Rockwell Automation Connected Components Workbench Improper Input Validation

Rockwell Automation Connected Components Workbench v12.00.00 and prior does not sanitize paths specified within the .ccwarc archive file during extraction. This type of vulnerability is also commonly referred to as a Zip Slip. A local, authenticated attacker can create a malicious .ccwarc archive file that, when opened by Connected Components Workbench, will allow the attacker to gain the privileges of the software. If the software is running at SYSTEM level, the attacker will gain admin level privileges. User interaction is required for this exploit to be successful.

Action-Not Available
Vendor-Rockwell Automation, Inc.
Product-connected_components_workbenchConnected Components Workbench
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Details not found