The Web server password authentication mechanism used by the products is vulnerable to a MitM and Replay attack. Successful exploitation of this vulnerability will allow unauthorized access of the product’s Web server to view and alter product configuration and diagnostics information. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400
The default configuration of EMC Smarts Network Configuration Manager (NCM) before 9.1 does not require authentication for database access, which allows remote attackers to have an unspecified impact via a network session.
Open&Compact FTP Server (Open-FTPD) 1.2 and earlier allows remote attackers to bypass authentication by sending (1) LIST, (2) RETR, (3) STOR, or other commands without performing the required login steps first.
Unknown vulnerability in Cisco Catalyst 7.5(1) allows local users to bypass authentication and gain access to the enable mode without a password.
In resetPasswordInternal of DevicePolicyManagerService.java, there is a possible bypass of password reset protection due to an unusual root cause. Remote user interaction is needed for exploitation.Product: AndroidVersions: Android-8.1 Android-9Android ID: A-110172241
Splunk 4.2.5 and earlier, when a Free license is selected, enables potentially undesirable functionality within an environment that intentionally does not support authentication, which allows remote attackers to (1) read arbitrary files via a management-console session that leverages the ability to create crafted data sources, or (2) execute management commands via an HTTP request.
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie.
Due to the lack of firmware authentication in the upgrade process of T&W WIFI Repeater BE126 devices, an attacker can craft a malicious firmware and use it as an update.
Multiple Lenze products of the cabinet series skip the password verification upon second login. After a user has been logged on to the device once, a remote attacker can get full access without knowledge of the password.
Session fixation vulnerability in Mambo 4.6.2 CMS allows remote attackers to hijack web sessions by setting the Cookie parameter.
IBM LoopBack (IBM API Connect 2018.1, 2018.4.1, 5.0.8.0, and 5.0.8.4) could allow an attacker to bypass authentication if the AccessToken Model is exposed over a REST API, it is then possible for anyone to create an AccessToken for any User provided they know the userId and can hence get access to the other user’s data / access to their privileges (if the user happens to be an Admin for example). IBM X-Force ID: 148801.
A vulnerability in the authentication functionality of Cisco Wireless LAN Controller (WLC) Software could allow an unauthenticated, remote attacker to bypass authentication controls and log in to the device through the management interface This vulnerability is due to the improper implementation of the password validation algorithm. An attacker could exploit this vulnerability by logging in to an affected device with crafted credentials. A successful exploit could allow the attacker to bypass authentication and log in to the device as an administrator. The attacker could obtain privileges that are the same level as an administrative user but it depends on the crafted credentials. Note: This vulnerability exists because of a non-default device configuration that must be present for it to be exploitable. For details about the vulnerable configuration, see the Vulnerable Products section of this advisory.
A vulnerability has been identified in SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (Versions V7.1 < V7.1 Upd3), SIMATIC IT UA Discrete Manufacturing (Versions < V1.2), SIMATIC IT UA Discrete Manufacturing (Versions V1.2), SIMATIC IT UA Discrete Manufacturing (Versions V1.3), SIMATIC IT UA Discrete Manufacturing (Versions V2.3), SIMATIC IT UA Discrete Manufacturing (Versions V2.4). An attacker with network access to the installation could bypass the application-level authentication. In order to exploit the vulnerability, an attacker must obtain network access to an affected installation and must obtain a valid username to the system. Successful exploitation requires no user privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known.
Intelbras NPLUG 1.0.0.14 wireless repeater devices have a critical vulnerability that allows an attacker to authenticate in the web interface just by using "admin:" as the name of a cookie.
If RSH service is enabled on Junos OS and if the PAM authentication is disabled, a remote unauthenticated attacker can obtain root access to the device. RSH service is disabled by default on Junos. There is no documented CLI command to enable this service. However, an undocumented CLI command allows a privileged Junos user to enable RSH service and disable PAM, and hence expose the system to unauthenticated root access. When RSH is enabled, the device is listing to RSH connections on port 514. This issue is not exploitable on platforms where Junos release is based on FreeBSD 10+. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D77 on SRX Series; 12.3 versions prior to 12.3R12-S10; 12.3X48 versions prior to 12.3X48-D75 on SRX Series; 14.1X53 versions prior to 14.1X53-D47 on QFX/EX Series; 15.1 versions prior to 15.1R4-S9, 15.1R6-S6, 15.1R7; 15.1X49 versions prior to 15.1X49-D131, 15.1X49-D140 on SRX Series; 15.1X53 versions prior to 15.1X53-D59 on EX2300/EX3400 Series; 15.1X53 versions prior to 15.1X53-D67 on QFX10K Series; 15.1X53 versions prior to 15.1X53-D233 on QFX5200/QFX5110 Series; 15.1X53 versions prior to 15.1X53-D471, 15.1X53-D490 on NFX Series; 16.1 versions prior to 16.1R3-S9, 16.1R4-S9, 16.1R5-S4, 16.1R6-S4, 16.1R7; 16.2 versions prior to 16.2R2-S5; 17.1 versions prior to 17.1R1-S7, 17.1R2-S7, 17.1R3; 17.2 versions prior to 17.2R1-S6, 17.2R2-S4, 17.2R3; 17.2X75 versions prior to 17.2X75-D110, 17.2X75-D91; 17.3 versions prior to 17.3R1-S4, 17.3R2-S2, 17.3R3; 17.4 versions prior to 17.4R1-S3, 17.4R2; 18.2X75 versions prior to 18.2X75-D5.
The web interface on Dahua DHI-HCVR7216A-S3 devices with NVR Firmware 3.210.0001.10 2016-06-06, Camera Firmware 2.400.0000.28.R 2016-03-29, and SmartPSS Software 1.16.1 2017-01-19 allows remote attackers to obtain login access by leveraging knowledge of the MD5 Admin Hash without knowledge of the corresponding password, a different vulnerability than CVE-2013-6117.
Session hijack vulnerability in httpd on ASUS RT-N56U, RT-N66U, RT-AC66U, RT-N66R, RT-AC66R, RT-AC68U, RT-AC68R, RT-N66W, RT-AC66W, RT-AC87R, RT-AC87U, RT-AC51U, RT-AC68P, RT-N11P, RT-N12+, RT-N12E B1, RT-AC3200, RT-AC53U, RT-AC1750, RT-AC1900P, RT-N300, and RT-AC750 routers with firmware before 3.0.0.4.380.7378; RT-AC68W routers with firmware before 3.0.0.4.380.7266; and RT-N600, RT-N12+ B1, RT-N11P B1, RT-N12VP B1, RT-N12E C1, RT-N300 B1, and RT-N12+ Pro routers with firmware before 3.0.0.4.380.9488; and Asuswrt-Merlin firmware before 380.65_2 allows remote attackers to steal any active admin session by sending cgi_logout and asusrouter-Windows-IFTTT-1.0 in certain HTTP headers.
An issue was discovered in ABOOT in OnePlus 3 and 3T OxygenOS before 4.0.2. The attacker can reboot the device into the fastboot mode, which could be done without any authentication. A physical attacker can press the "Volume Up" button during device boot, where an attacker with ADB access can issue the adb reboot bootloader command. Then, the attacker can put the platform's SELinux in permissive mode, which severely weakens it, by issuing: fastboot oem selinux permissive.
Networking OS10, versions prior to October 2021 with Smart Fabric Services enabled, contains an authentication bypass vulnerability. A remote unauthenticated attacker could exploit this vulnerability to gain access and perform actions on the affected system.
An insufficient authentication vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow a malicious, network based, unauthenticated attacker to perform privileged actions to gain complete control over the environment.
In LXC 2.0, many template scripts download code over cleartext HTTP, and omit a digital-signature check, before running it to bootstrap containers.
The Festo CECX-X-C1 Modular Master Controller with CoDeSys and CECX-X-M1 Modular Controller with CoDeSys and SoftMotion do not require authentication for connections to certain TCP ports, which allows remote attackers to (1) modify the configuration via a request to the debug service on port 4000 or (2) delete log entries via a request to the log service on port 4001.
freeSSHd.exe in freeSSHd through 1.2.6 allows remote attackers to bypass authentication via a crafted session, as demonstrated by an OpenSSH client with modified versions of ssh.c and sshconnect2.c.