TCExam before 14.1.2 has XSS via an ff_ or xl_ field.
Monkshu is an enterprise application server for mobile apps (iOS and Android), responsive HTML 5 apps, and JSON API services. In version 2.90 and earlier, there is a reflected cross-site scripting vulnerability in frontend HTTP server. The attacker can send in a carefully crafted URL along with a known bug in the server which will cause a 500 error, and the response will then embed the URL provided by the hacker. The impact is moderate as the hacker must also be able to craft an HTTP request which should cause a 500 server error. None such requests are known as this point. The issue is patched in version 2.95. As a workaround, one may use a disk caching plugin.
An error in a page handler of the VRM may lead to a reflected cross site scripting (XSS) in the web-based interface. To exploit this vulnerability an attack must be able to modify the HTTP header that is sent. This issue also affects installations of the DIVAR IP and BVMS with VRM installed.
An issue was discovered in Devolutions Server before 2020.3. There is a cross-site scripting (XSS) vulnerability in entries of type Document.
An issue was discovered in Eventum 3.5.0. /htdocs/list.php has XSS via the show_notification_list_issues or show_authorized_issues parameter.
A CWE-79 Improper Neutralization of Input During Web Page Generation (�Cross-site Scripting�) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)
An Improper Neutralization of Script-Related HTML Tags in Fortinet FortiAnalyzer 5.6.0 and below and FortiManager 5.6.0 and below allows an attacker to send DHCP request containing malicious scripts in the HOSTNAME parameter. The malicious script code is executed while viewing the logs in FortiAnalyzer and FortiManager (with FortiAnalyzer feature enabled).
On all 7.x and 6.x versions (fixed in 8.0.0), undisclosed BIG-IQ pages have a reflected cross-site scripting vulnerability. Note: Software versions which have reached End of Software Development (EoSD) are not evaluated.
The "All Subscribers" setting page of Popup Builder was vulnerable to reflected Cross-Site Scripting.
DIGISOL DG-HR3400 devices have XSS via a modified SSID when the apssid value is unchanged.
Multiple cross-site scripting (XSS) vulnerabilities in Symphony CMS 2.0.7 and 2.1.1 allow remote attackers to inject arbitrary web script or HTML via the (1) fields[website] parameter in the post comments feature in articles/a-primer-to-symphony-2s-default-theme/ or (2) send-email[recipient] parameter to about/. NOTE: some of these details are obtained from third party information.
mao10cms 6 allows XSS via the m=bbs&a=index page.
An XSS issue was discovered in Sandoba CP:Shop v2016.1. The vulnerability is located in the `admin.php` file of the `./cpshop/` module. Remote attackers are able to inject their own script codes to the client-side requested vulnerable web-application parameters. The attack vector of the vulnerability is non-persistent and the request method to inject/execute is GET with the path, search, rename, or dir parameter.
Cross-site scripting (XSS) vulnerability in the powermail extension 1.5.3 and earlier for TYPO3 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
This affects all versions of package pekeupload. If an attacker induces a user to upload a file whose name contains javascript code, the javascript code will be executed.
Cross-site scripting vulnerability in the API 404 page on Xiaomi Mi Router 3 version 2.22.15 allows attackers to execute arbitrary JavaScript via a modified URL path.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
Unauthenticated stored cross-site scripting (XSS) exists in multiple TP-Link products including WIFI Routers (Wireless AC routers), Access Points, ADSL + DSL Gateways and Routers, which affects TD-W9977v1, TL-WA801NDv5, TL-WA801Nv6, TL-WA802Nv5, and Archer C3150v2 devices through the improper validation of the hostname. Some of the pages including dhcp.htm, networkMap.htm, dhcpClient.htm, qsEdit.htm, and qsReview.htm and use this vulnerable hostname function (setDefaultHostname()) without sanitization.
OX App Suite through 7.10.5 allows XSS via JavaScript code in a shared XCF file.
Nagios Fusion before 4.1.4 has XSS, aka TPS#13332-13335.
The google-language-translator plugin before 5.0.06 for WordPress has XSS.
Cross-site scripting (XSS) vulnerability in Products_Results.php in PowerStore 3.0 allows remote attackers to inject arbitrary web script or HTML via the totalRows_WADAProducts parameter.
A Cross-site Scripting (XSS) vulnerability in Fortinet FortiOS 6.0.0 to 6.0.4, 5.6.0 to 5.6.7, 5.4.0 to 5.4.12, 5.2 and below and Fortinet FortiProxy 2.0.0, 1.2.8 and below under SSL VPN web portal allows attacker to execute unauthorized malicious script code via the error or message handling parameters.
Cross-site scripting (XSS) vulnerability in Attachmate Reflection for the Web 2008 R2 (builds 10.1.569 and earlier), 2008 R1, and 9.6 and earlier allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
The Cooked Pro WordPress plugin before 1.7.5.6 was affected by unauthenticated reflected Cross-Site Scripting issues, due to improper sanitisation of user input while being output back in pages as an arbitrary attribute.
A Reflected Cross Site Scripting (XSS) Vulnerability was discovered in Adrenalin 5.4 HRMS Software. The user supplied input containing JavaScript is echoed back in JavaScript code in an HTML response via the ShiftEmployeeSearch.aspx prntFrmName or prntDDLCntrlName parameter.
The web server is vulnerable to reflected XSS and therefore an attacker might be able to execute scripts on a client’s computer by sending the client a manipulated URL.
DaDaBIK 4.3 beta3, when running in a case-sensitive environment, does not include the htmLawed library, which allows remote attackers to bypass the protection mechanism for CVE-2010-4355 and conduct cross-site scripting (XSS) attacks via the (1) html content and (2) rich_editor fields. NOTE: some of these details are obtained from third party information.
Revive Adserver before 5.1.1 is vulnerable to a reflected XSS vulnerability in userlog-index.php via the `period_preset` parameter.
Revive Adserver before v5.2.0 is vulnerable to a reflected XSS vulnerability in the `statsBreakdown` parameter of stats.php (and possibly other scripts) due to single quotes not being escaped. An attacker could trick a user with access to the user interface of a Revive Adserver instance into clicking on a specifically crafted URL and pressing a certain key combination to execute injected JavaScript code.
OX App Suite through 7.10.4 allows XSS via a contact whose name contains JavaScript code.
The google-document-embedder plugin before 2.6.2 for WordPress has XSS.
Zoho ManageEngine Desktop Central 10.0.271 has XSS via the "Features & Articles" search field to the /advsearch.do?SUBREQUEST=XMLHTTP URI.
joyplus-cms 1.6.0 has XSS in admin_player.php, related to manager/index.php "system manage" and "add" actions.
Revive Adserver before 5.1.0 is vulnerable to a reflected cross-site scripting (XSS) vulnerability via the publicly accessible afr.php delivery script. While this issue was previously addressed in modern browsers as CVE-2020-8115, some older browsers (e.g., IE10) that do not automatically URL encode parameters were still vulnerable.
Password disclosure in password.htm in TOTOLINK A3002RU version 1.0.8 allows attackers to obtain the plaintext password for the admin user by making a GET request for password.htm.
OX App Suite through 7.10.3 allows XSS via the ajax/apps/manifests query string.
Cross-site scripting in notice_gen.htm in TOTOLINK A3002RU version 1.0.8 allows attackers to execute arbitrary JavaScript by modifying the "Input your notice URL" field.
The GiveWP – Donation Plugin and Fundraising Platform WordPress plugin before 2.10.0 was affected by a reflected Cross-Site Scripting vulnerability inside of the administration panel, via the 's' GET parameter on the Donors page.
The Realteo WordPress plugin before 1.2.4, used by the Findeo Theme, did not properly sanitise the keyword_search, search_radius. _bedrooms and _bathrooms GET parameters before outputting them in its properties page, leading to an unauthenticated reflected Cross-Site Scripting issue.
Unvalidated input and lack of output encoding in the WP Shieldon WordPress plugin, version 1.6.3 and below, leads to Unauthenticated Reflected Cross-Site Scripting (XSS) when the CAPTCHA page is shown could lead to privileged escalation.
OX App Suite through 7.10.4 allows XSS via the subject of a task.
On version 16.0.x before 16.0.1.2, 15.1.x before 15.1.3.1, and 14.1.x before 14.1.4.3, a DOM based cross-site scripting (XSS) vulnerability exists in an undisclosed page of the BIG-IP Configuration utility that allows an attacker to execute JavaScript in the context of the currently logged-in user. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
OX App Suite through 7.10.4 allows XSS via an inline binary file.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
DIAEnergie Version 1.7.5 and prior is vulnerable to a reflected cross-site scripting attack through error pages that are returned by “.NET Request.QueryString”.
Cross-site scripting (XSS) vulnerability in index.php in Qsoft K-Links allows remote attackers to inject arbitrary web script or HTML via the login_message parameter in a login action.
This Advanced Order Export For WooCommerce WordPress plugin before 3.1.8 helps you to easily export WooCommerce order data. The tab parameter in the Admin Panel is vulnerable to reflected XSS.
The dwnldr plugin before 1.01 for WordPress has XSS via the User-Agent HTTP header.
An issue was discovered in Joomla! 2.5.0 through 3.9.24. Missing filtering of feed fields could lead to xss issues.