Milesight IP security cameras through 2016-11-14 have a default root password in /etc/shadow that is the same across different customers' installations.
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data.
A vulnerability was determined in yeqifu carRental up to 3fabb7eae93d209426638863980301d6f99866b3. Affected by this vulnerability is an unknown functionality of the file /carRental_war/druid/login.html of the component Druid. Executing manipulation can lead to hard-coded credentials. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized. This product operates on a rolling release basis, ensuring continuous delivery. Consequently, there are no version details for either affected or updated releases.
Milesight IP security cameras through 2016-11-14 have a default set of 10 privileged accounts with hardcoded credentials. They are accessible if the customer has not configured 10 actual user accounts.
Milesight IP security cameras through 2016-11-14 have a hardcoded SSL private key under the /etc/config directory.
A reliance on a static, hard-coded credential in the design of the cloud-based storage system of Practecol's Guardzilla All-In-One Video Security System allows an attacker to view the private data of all users of the Guardzilla device.
The IMM2 First Failure Data Capture function collects management module logs and diagnostic information when a hardware error is detected. This information is made available for download through an SFTP server hosted on the IMM2 management network interface. In versions earlier than 4.90 for Lenovo System x and earlier than 6.80 for IBM System x, the credentials to access the SFTP server are hard-coded and described in the IMM2 documentation, allowing an attacker with management network access to obtain the collected FFDC data. After applying the update, the IMM2 will create random SFTP credentials for use with OneCLI.
auth_db_config.py in Pyftpd 0.8.4 contains hard-coded usernames and passwords for the (1) test, (2) user, and (3) roxon accounts, which allows remote attackers to read arbitrary files from the FTP server.
An issue was discovered on the D-Link DWR-932B router. There is a hardcoded WPS PIN of 28296607.
ZTE E8810/E8820/E8822 series routers have an information leak vulnerability, which is caused by hard-coded MQTT service access credentials on the device. The remote attacker could use this credential to connect to the MQTT server, so as to obtain information about other devices by sending specific topics. This affects:<ZXHN E8810, ZXHN E8820, ZXHN E8822><E8810 V1.0.26, E8810 V2.0.1, E8820 V1.1.3L, E8820 V2.0.13, E8822 V2.0.13>
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The exported device configuration is encrypted with the hardcoded Pxift* password in some cases.
atbox.htm on D-Link DSL-2770L devices allows remote unauthenticated attackers to discover admin credentials.
spaces.htm on multiple D-Link devices (DSL, DIR, DWR) allows remote unauthenticated attackers to discover admin credentials.
An issue was discovered in PTC ThingWorx Platform 6.5 through 8.2. There is a hardcoded encryption key.
An issue was discovered in CommentsService.ashx in OnyakTech Comments Pro 3.8. An attacker can download a copy of the installer, decompile it, and discover a hardcoded IV used to encrypt the username and userid in the comment POST request. Additionally, the attacker can decrypt the encrypted encryption key (sent as a parameter in the comment form request) by setting this encrypted value as the username, which will appear on the comment page in its decrypted form. Using these two values (combined with the encryption functionality discovered in the decompiled installer), the attacker can encrypt another user's ID and username. These values can be used as part of the comment posting request in order to spoof the user.
An issue was discovered on FiberHome HG6245D devices through RP2613. The password for the enable command is gpon.
An attacker can gain VxWorks Shell after login due to hard-coded credentials on a KUKA KR C4 control software for versions prior to 8.7 or any product running KSS.
An attacker can gain full access (read/write/delete) to sensitive folders due to hard-coded credentials on KUKA KR C4 control software for versions prior to 8.7 or any product running KSS.
In Weidmueller Industrial WLAN devices in multiple versions the usage of hard-coded cryptographic keys within the service agent binary allows for the decryption of captured traffic across the network from or to the device.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The exported device configuration is encrypted with the hardcoded BpP+2R9*Q password in some cases.
The default administrator account & password of the EDIMAX wireless network camera is hard-coded. Remote attackers can disassemble firmware to obtain the privileged permission and further control the devices.
The EPSON iPrint application 6.6.3 for Android contains hard-coded API and Secret keys for the Dropbox, Box, Evernote and OneDrive services.
A hardcoded passphrase, in CA Unified Infrastructure Management 8.5.1, 8.5, and 8.4.7, allows attackers to access sensitive information.
IBM Security Identity Manager 7.0.2 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 200252.
Use of Hard-coded Credentials in temi Robox OS prior to 120, temi Android app up to 1.3.7931 allows remote attackers to listen in on any ongoing calls between temi robots and their users if they can brute-force/guess a six-digit value via unspecified vectors.
Hardcoded default root credentials exist on the ecobee3 lite 4.5.81.200 device. This allows a threat actor to gain access to the password-protected bootloader environment through the serial console.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web management is done over HTTPS, using a hardcoded private key that has 0777 permissions.
An issue was discovered on FiberHome HG6245D devices through RP2613. There is a password of four hexadecimal characters for the admin account. These characters are generated in init_3bb_password in libci_adaptation_layer.so.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded f~i!b@e#r$h%o^m*esuperadmin / s(f)u_h+g|u credentials for an ISP.
A use of hard-coded cryptographic key vulnerability in the SSLVPN of FortiOS before 7.0.1 may allow an attacker to retrieve the key by reverse engineering.
An issue was discovered in svc-login.php in Void Aural Rec Monitor 9.0.0.1. Passwords are stored in unencrypted source-code text files. This was noted when accessing the svc-login.php file. The value is used to authenticate a high-privileged user upon authenticating with the server.
Certain TP-Link devices have a Hardcoded Encryption Key. This affects NC200 2.1.9 build 200225, N210 1.0.9 build 200304, NC220 1.3.0 build 200304, NC230 1.3.0 build 200304, NC250 1.3.0 build 200304, NC260 1.5.2 build 200304, and NC450 1.5.3 build 200304.
An issue was discovered in Programi Bilanc build 007 release 014 31.01.2020 and possibly below. It relies on broken encryption with a weak and guessable static encryption key.
A hardcoded secret key, in CA Unified Infrastructure Management 8.5.1, 8.5, and 8.4.7, allows attackers to access sensitive information.
Usage of hard-coded cryptographic keys to encrypt configuration files and debug logs in FortiAuthenticator versions before 6.3.0 may allow an attacker with access to the files or the CLI configuration to decrypt the sensitive data, via knowledge of the hard-coded key.
An issue was discovered in EyesOfNetwork 5.3. The installation uses the same API key (hardcoded as EONAPI_KEY in include/api_functions.php for API version 2.4.2) by default for all installations, hence allowing an attacker to calculate/guess the admin access token.
A vulnerability classified as critical has been found in IROAD X5 Mobile App up to 5.2.5 on Android. Affected is an unknown function of the component API Endpoint. The manipulation leads to hard-coded credentials. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
Retty App for Android versions prior to 4.8.13 and Retty App for iOS versions prior to 4.11.14 uses a hard-coded API key for an external service. By exploiting this vulnerability, API key for an external service may be obtained by analyzing data in the app.
IBM Security Verify Information Queue 1.0.6 and 1.0.7 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 198192.
A hard-coded credentials issue was discovered on Mimosa Client Radios before 2.2.3, Mimosa Backhaul Radios before 2.2.3, and Mimosa Access Points before 2.2.3. These devices run Mosquitto, a lightweight message broker, to send information between devices. By using the vendor's hard-coded credentials to connect to the broker on any device (whether it be an AP, Client, or Backhaul model), an attacker can view all the messages being sent between the devices. If an attacker connects to an AP, the AP will leak information about any clients connected to it, including the serial numbers, which can be used to remotely factory reset the clients via a page in their web interface.
A Security Bypass vulnerability exists in TP-LINK IP Cameras TL-SC 3130, TL-SC 3130G, 3171G, 4171G, and 3130 1.6.18P12 due to default hard-coded credentials for the administrative Web interface, which could let a malicious user obtain unauthorized access to CGI files.
An issue was discovered on Enphase Envoy R3.x and D4.x devices. There are hardcoded web-panel login passwords for the installer and Enphase accounts. The passwords for these accounts are hardcoded values derived from the MD5 hash of the username and serial number mixed with some static strings. The serial number can be retrieved by an unauthenticated user at /info.xml. These passwords can be easily calculated by an attacker; users are unable to change these passwords.
On the TP-Link TL-SG108E 1.0, there is a hard-coded ciphering key (a long string beginning with Ei2HNryt). This affects the 1.1.2 Build 20141017 Rel.50749 firmware.
An Authentication vulnerability exists in D-LINK WCS-1100 1.02, TESCO DCS-2121 1.05_TESCO, TESCO DCS-2102 1.05_TESCO, DCS-7510 1.00, DCS-7410 1.00, DCS-6410 1.00, DCS-5635 1.01, DCS-5605 1.01, DCS-5230L 1.02, DCS-5230 1.02, DCS-3430 1.02, DCS-3411 1.02, DCS-3410 1.02, DCS-2121 1.06_FR, DCS-2121 1.06, DCS-2121 1.05_RU, DCS-2102 1.06_FR, DCS-2102 1.06, DCS-2102 1.05_RU, DCS-1130L 1.04, DCS-1130 1.04_US, DCS-1130 1.03, DCS-1100L 1.04, DCS-1100 1.04_US, and DCS-1100 1.03 due to hard-coded credentials that serve as a backdoor, which allows remote attackers to access the RTSP video stream.
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes.
A Use of Hard-Coded Password issue was discovered in Phoenix Broadband PowerAgent SC3 BMS, all versions prior to v6.87. Use of a hard-coded password may allow unauthorized access to the device.
Use of a hard-coded cryptographic key to encrypt password data in CLI configuration in FortiManager 6.2.3 and below, FortiAnalyzer 6.2.3 and below may allow an attacker with access to the CLI configuration or the CLI backup file to decrypt the sensitive data, via knowledge of the hard-coded key.
iball Baton 150M iB-WRA150N v1 00000001 1.2.6 build 110401 Rel.47776n devices are prone to an authentication bypass vulnerability that allows remote attackers to view and modify administrative router settings by reading the HTML source code of the password.cgi file.
A Use of Hard-Coded Cryptographic Key issue was discovered in Hyundai Motor America Blue Link 3.9.5 and 3.9.4. The application uses a hard-coded decryption password to protect sensitive user information.