A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to access internal services that should be restricted on an affected device, such as the NX-API. The vulnerability is due to insufficient validation of arguments passed to a certain CLI command. An attacker could exploit this vulnerability by including malicious input as the argument to the affected command. A successful exploit could allow the attacker to bypass intended restrictions and access internal services of the device. An attacker would need valid device credentials to exploit this vulnerability.
A vulnerability in the Image Signature Verification feature of Cisco NX-OS Software could allow an authenticated, local attacker with administrator-level credentials to install a malicious software patch on an affected device. The vulnerability is due to improper verification of digital signatures for patch images. An attacker could exploit this vulnerability by crafting an unsigned software patch to bypass signature checks and loading it on an affected device. A successful exploit could allow the attacker to boot a malicious software patch image.
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker with administrator credentials to execute arbitrary commands on the underlying Linux operating system with the privilege level of root. The vulnerability is due to insufficient validation of arguments passed to a specific CLI command on the affected device. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying Linux operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability.
A vulnerability in the Python scripting subsystem of Cisco NX-OS Software could allow an authenticated, local attacker to escape the Python parser and issue arbitrary commands to elevate the attacker's privilege level. The vulnerability is due to insufficient sanitization of user-supplied parameters that are passed to certain Python functions in the scripting sandbox of the affected device. An attacker could exploit this vulnerability to escape the scripting sandbox and execute arbitrary commands to elevate the attacker's privilege level. To exploit this vulnerability, the attacker must have local access and be authenticated to the targeted device with administrative or Python execution privileges. These requirements could limit the possibility of a successful exploit.
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. MDS 9000 Series Multilayer Switches are affected in versions prior to 6.2(27), 8.1(1b), and 8.3(1). Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 7.3(3)D1(1), and 8.2(3).
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Nexus 3500 Platform Switches and Nexus 3000 Series Switches software versions prior to 7.0(3)I7(4) are affected.
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected running software versions prior to 7.0(3)I7(4). Nexus 3600 Platform Switches are affected running software versions prior to 7.0(3)F3(5). Nexus 9000 Series Switches in Stand are affected running software versions prior to 7.0(3)F3(5).
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 7.3(3)D1(1), and 8.2(3).
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. MDS 9000 Series Multilayer Switches are affected running software versions prior to 6.2(27) and 8.2(3). Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(6). Nexus 3500 Platform Switches are affected running software versions prior to 6.0(2)A8(11) and 7.0(3)I7(6). Nexus 3600 Platform Switches are affected running software versions prior to 7.0(3)F3(5). Nexus 9000 Series Switches in Standalone NX-OS Mode are affected running software versions prior to 7.0(3)I4(9), 7.0(3)I7(6). Nexus 9500 R-Series Line Cards and Fabric Modules are affected running software versions prior to 7.0(3)F3(5). Nexus 7000 and 7700 Series Switches are affected running software versions prior to 6.2(22) and 8.2(3).
A vulnerability in the Image Signature Verification feature of Cisco NX-OS Software could allow an authenticated, local attacker with administrator-level credentials to install a malicious software image on an affected device. The vulnerability is due to improper verification of digital signatures for software images. An attacker could exploit this vulnerability by loading an unsigned software image on an affected device. A successful exploit could allow the attacker to boot a malicious software image. Note: The fix for this vulnerability requires a BIOS upgrade as part of the software upgrade. For additional information, see the Details section of this advisory. Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I7(5). Nexus 9000 Series Fabric Switches in ACI Mode are affected running software versions prior to 13.2(1l). Nexus 9000 Series Switches in Standalone NX-OS Mode are affected running software versions prior to 7.0(3)I7(5). Nexus 9500 R-Series Line Cards and Fabric Modules are affected running software versions prior to 7.0(3)F3(5).
A vulnerability in Cisco Small Business SPA500 Series IP Phones could allow a physically proximate attacker to execute arbitrary commands on the device. The vulnerability is due to the presence of development testing and verification scripts that remained on the device. An attacker could exploit this vulnerability by accessing the physical interface of a device and inserting a USB storage device. A successful exploit could allow the attacker to execute scripts on the device in an elevated security context.
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to escalate lower-level privileges to the administrator level. The vulnerability is due to insufficient authorization enforcement. An attacker could exploit this vulnerability by authenticating to the targeted device and executing commands that could lead to elevated privileges. A successful exploit could allow an attacker to make configuration changes to the system as administrator. Nexus 3000 Series Switches are affected in versions prior to 7.0(3)I7(4). Nexus 3500 Platform Switches are affected in versions prior to 7.0(3)I7(4). Nexus 3600 Platform Switches are affected in versions prior to 7.0(3)F3(5). Nexus 9000 Series Switches-Standalone are affected in versions prior to 7.0(3)I7(4). Nexus 9500 R-Series Line Cards and Fabric Modules are affected in versions prior to 7.0(3)F3(5).
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. MDS 9000 Series Multilayer Switches are affected in versions prior to 6.2(27), 8.1(1b), and 8.3(2). Nexus 3500 Platform Switches are affected in versions prior to 7.0(3)I7(6). Nexus 3000 Series Switches are affected in versions prior to 7.0(3)I4(9) and 7.0(3)I7(6). Nexus 3600 Platform Switches are affected in versions prior to 7.0(3)F3(5). Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 7.3(3)D1(1), 8.2(3), and 8.3(2). Nexus 9000 Series Switches in Standalone NX-OS Mode are affected in versions prior to 7.0(3)I4(9) and7.0(3)I7(6). Nexus 9500 R-Series Line Cards and Fabric Modules are affected in versions prior to 7.0(3)F3(5).
A vulnerability in the CLI of Cisco NX-OS Software and Cisco FXOS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Firepower 4100 Series Next-Generation Firewalls are affected running software versions prior to 2.2.2.91, 2.3.1.110, and 2.4.1.222. Firepower 9300 Security Appliance are affected running software versions prior to 2.2.2.91, 2.3.1.110, and 2.4.1.222. MDS 9000 Series Multilayer Switches are affected running software versions prior to 6.2(25) and 8.3(1). Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(5). Nexus 3500 Platform Switches are affected running software versions prior to 7.0(3)I7(5). Nexus 3600 Platform Switches are affected running software versions prior to 7.0(3)F3(5). Nexus 2000, 5500, 5600, and 6000 Series Switches are affected running software versions prior to 7.1(5)N1(1b) and 7.3(4)N1(1). Nexus 7000 and 7700 Series Switches are affected running software versions prior to 6.2(22), 7.3(3)D1(1), 8.2(3). Nexus 9000 Series Switches in Standalone NX-OS Mode are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(5). Nexus 9500 R-Series Line Cards and Fabric Modules are affected running software versions prior to 7.0(3)F3(5).
A vulnerability in the DLL loading component of Cisco Advanced Malware Protection (AMP) for Endpoints on Windows could allow an authenticated, local attacker to disable system scanning services or take other actions to prevent detection of unauthorized intrusions. To exploit this vulnerability, the attacker would need to have administrative credentials on the Windows system. The vulnerability is due to the improper validation of resources loaded by a system process at run time. An attacker could exploit this vulnerability by crafting a malicious DLL file and placing it in a specific location on the targeted system. A successful exploit could allow the attacker to disable the targeted system's scanning services and ultimately prevent the system from being protected from further intrusion. There are no workarounds that address this vulnerability.
A vulnerability in CLI of Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, local attacker to inject XML into the command parser. This vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by including crafted input in commands. A successful exploit could allow the attacker to inject XML into the command parser, which could result in unexpected processing of the command and unexpected command output.
A vulnerability in Cisco IOS ROM Monitor (ROMMON) Software for Cisco Catalyst 6800 Series Switches could allow an unauthenticated, local attacker to bypass Cisco Secure Boot validation checks and load a compromised software image on an affected device. The vulnerability is due to the presence of a hidden command in the affected software. An attacker could exploit this vulnerability by connecting to an affected device via the console, forcing the device into ROMMON mode, and writing a malicious pattern to a specific memory address on the device. A successful exploit could allow the attacker to bypass signature validation checks by Cisco Secure Boot technology and load a compromised software image on the affected device. A compromised software image is any software image that has not been digitally signed by Cisco.
A vulnerability in the configuration of a local database installed as part of the Cisco Energy Management Suite (CEMS) could allow an authenticated, local attacker to access and alter confidential data. The vulnerability is due to the installation of the PostgreSQL database with unchanged default access credentials. An attacker could exploit this vulnerability by logging in to the machine where CEMS is installed and establishing a local connection to the database. The fix for this vulnerability randomizes the database access password in new installations; however, the fix will not change the password for existing installations. Users are required to manually change the password, as documented in the Workarounds section of this advisory. There are workarounds that address this vulnerability.
A vulnerability in certain CLI commands of Cisco Identity Services Engine (ISE) could allow an authenticated, local attacker to execute arbitrary commands on the host operating system with the privileges of the local user, aka Command Injection. These commands should have been restricted from this user. The vulnerability is due to insufficient input validation of CLI command user input. An attacker could exploit this vulnerability by authenticating to the targeted device and issuing a CLI command with crafted user input. A successful exploit could allow the attacker to execute arbitrary commands on the affected system that should be restricted. The attacker would need to have valid user credentials for the device. Cisco Bug IDs: CSCvf49844.
A vulnerability in the role-based access-checking mechanisms of Cisco Unified Computing System (UCS) Software could allow an authenticated, local attacker to execute arbitrary commands on an affected system. The vulnerability exists because the affected software lacks proper input and validation checks for certain file systems. An attacker could exploit this vulnerability by issuing crafted commands in the CLI of an affected system. A successful exploit could allow the attacker to cause other users to execute unwanted arbitrary commands on the affected system. Cisco Bug IDs: CSCvf52994.
A vulnerability in TACACS authentication with Cisco Wireless LAN Controller (WLC) Software could allow an authenticated, local attacker to perform certain operations within the GUI that are not normally available to that user on the CLI. The vulnerability is due to incorrect parsing of a specific TACACS attribute received in the TACACS response from the remote TACACS server. An attacker could exploit this vulnerability by authenticating via TACACS to the GUI on the affected device. A successful exploit could allow an attacker to create local user accounts with administrative privileges on an affected WLC and execute other commands that are not allowed from the CLI and should be prohibited.
A vulnerability in BIOS authentication management of Cisco 5000 Series Enterprise Network Compute System and Cisco Unified Computing (UCS) E-Series Servers could allow an unauthenticated, local attacker to bypass the BIOS authentication and execute actions as an unprivileged user. The vulnerability is due to improper security restrictions that are imposed by the affected system. An attacker could exploit this vulnerability by submitting an empty password value to an affected device's BIOS authentication prompt. An exploit could allow the attacker to have access to a restricted set of user-level BIOS commands. Cisco Bug IDs: CSCvh83260.
A vulnerability in the CLI of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an authenticated, high-privileged, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command parameters in the CLI parser. An attacker could exploit this vulnerability by invoking a vulnerable CLI command with crafted malicious parameters. An exploit could allow the attacker to execute arbitrary commands with a non-root user account on the underlying Linux operating system of the affected device. Cisco Bug IDs: CSCvi09723.
Stack-based buffer overflow in the Cisco Thor decoder before commit 18de8f9f0762c3a542b1122589edb8af859d9813 allows local users to cause a denial of service (segmentation fault) and execute arbitrary code via a crafted non-conformant Thor bitstream.
The Comcast firmware on Motorola MX011ANM (firmware version MX011AN_2.9p6s1_PROD_sey) devices allows physically proximate attackers to access an SNMP server by connecting a cable to the Ethernet port, and then establishing communication with the device's link-local IPv6 address.
A vulnerability in the Telnet CLI command of Cisco NX-OS System Software 7.1 through 7.3 running on Cisco Nexus Series Switches could allow an authenticated, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command arguments. An attacker could exploit this vulnerability by injecting crafted command arguments into the Telnet CLI command. An exploit could allow the attacker to read or write arbitrary files at the user's privilege level outside of the user's path. Cisco Bug IDs: CSCvb86771.
A vulnerability in the management of shell user accounts for Cisco Policy Suite (CPS) Software for CPS appliances could allow an authenticated, local attacker to gain elevated privileges on an affected system. The affected privilege level is not at the root level. The vulnerability is due to incorrect role-based access control (RBAC) for shell user accounts. An attacker could exploit this vulnerability by authenticating to an affected appliance and providing crafted user input via the CLI. A successful exploit could allow the attacker to acquire a higher privilege level than should have been granted. To exploit this vulnerability, the attacker must log in to the appliance with valid credentials. Cisco Bug IDs: CSCve37724. Known Affected Releases: 9.0.0, 9.1.0, 10.0.0, 11.0.0, 12.0.0.
A vulnerability in the CLI of Cisco ASR 5000 Series Aggregated Services Routers running the Cisco StarOS operating system could allow an authenticated, local attacker to bypass the CLI restrictions and execute commands on the underlying operating system. The vulnerability is due to insufficient input sanitization of user-supplied input at the CLI. An attacker could exploit this vulnerability by crafting a script on the device that will allow them to bypass built-in restrictions. An exploit could allow the unauthorized user to launch the CLI directly from a command shell. Cisco Bug IDs: CSCvd47722. Known Affected Releases: 21.0.v0.65839.
A vulnerability in the CLI of Cisco ASR 5000 Series Aggregated Services Routers running the Cisco StarOS operating system could allow an authenticated, local attacker to elevate their privileges to admin-level privileges. The vulnerability is due to incorrect permissions that are given to a set of users. An attacker could exploit this vulnerability by logging in to the shell of an affected device and elevating their privileges by modifying environment variables. An exploit could allow the attacker to gain admin-level privileges and take control of the affected device. Cisco Bug IDs: CSCvd47741. Known Affected Releases: 21.0.v0.65839.
A vulnerability in CLI command processing in the Cisco Firepower 4100 Series Next-Generation Firewall and Cisco Firepower 9300 Security Appliance could allow an authenticated, local attacker to inject arbitrary shell commands that are executed by the device. More Information: CSCvb61343. Known Affected Releases: 2.0(1.68). Known Fixed Releases: 2.0(1.118) 2.1(1.47) 92.1(1.1646) 92.1(1.1763) 92.2(1.101).
A vulnerability in the web-based GUI of Cisco UCS Director 6.0.0.0 and 6.0.0.1 could allow an authenticated, local attacker to execute arbitrary workflow items with just an end-user profile, a Privilege Escalation Vulnerability. The vulnerability is due to improper role-based access control (RBAC) after the Developer Menu is enabled in Cisco UCS Director. An attacker could exploit this vulnerability by enabling Developer Mode for his/her user profile with an end-user profile and then adding new catalogs with arbitrary workflow items to his/her profile. An exploit could allow an attacker to perform any actions defined by these workflow items, including actions affecting other tenants. Cisco Bug IDs: CSCvb64765.
The TrustZone implementation in certain Broadcom MediaxChange firmware could allow an unauthenticated, physically proximate attacker to achieve arbitrary code execution in the TrustZone Trusted Execution Environment (TEE) of an affected device. This, for example, affects certain Cisco IP Phone and Wireless IP Phone products before 2021-07-07. Exploitation is possible only when the attacker can disassemble the device in order to control the voltage/current for chip pins.
A vulnerability in the CLI of Cisco SD-WAN Software could allow an authenticated, local attacker to inject arbitrary commands to be executed with Administrator privileges on the underlying operating system. This vulnerability is due to insufficient input validation on certain CLI commands. An attacker could exploit this vulnerability by authenticating to the device and submitting crafted input to the CLI. The attacker must be authenticated as a low-privileged user to execute the affected commands. A successful exploit could allow the attacker to execute commands with Administrator privileges.
Multiple vulnerabilities in Cisco Network Convergence System (NCS) 540 Series Routers, only when running Cisco IOS XR NCS540L software images, and Cisco IOS XR Software for the Cisco 8000 Series Routers could allow an authenticated, local attacker to execute unsigned code during the boot process on an affected device. For more information about these vulnerabilities, see the Details section of this advisory.
Multiple vulnerabilities in Cisco Network Convergence System (NCS) 540 Series Routers, only when running Cisco IOS XR NCS540L software images, and Cisco IOS XR Software for the Cisco 8000 Series Routers could allow an authenticated, local attacker to execute unsigned code during the boot process on an affected device. For more information about these vulnerabilities, see the Details section of this advisory.
A vulnerability in virtualization channel messaging in Cisco Webex Meetings Desktop App for Windows could allow a local attacker to execute arbitrary code on a targeted system. This vulnerability occurs when this app is deployed in a virtual desktop environment and using virtual environment optimization. This vulnerability is due to improper validation of messages processed by the Cisco Webex Meetings Desktop App. A local attacker with limited privileges could exploit this vulnerability by sending malicious messages to the affected software by using the virtualization channel interface. A successful exploit could allow the attacker to modify the underlying operating system configuration, which could allow the attacker to execute arbitrary code with the privileges of a targeted user. Note: This vulnerability can be exploited only when Cisco Webex Meetings Desktop App is in a virtual desktop environment on a hosted virtual desktop (HVD) and is configured to use the Cisco Webex Meetings virtual desktop plug-in for thin clients.
Multiple clientless SSL VPN products that run in web browsers, including Stonesoft StoneGate; Cisco ASA; SonicWALL E-Class SSL VPN and SonicWALL SSL VPN; SafeNet SecureWire Access Gateway; Juniper Networks Secure Access; Nortel CallPilot; Citrix Access Gateway; and other products, when running in configurations that do not restrict access to the same domain as the VPN, retrieve the content of remote URLs from one domain and rewrite them so they originate from the VPN's domain, which violates the same origin policy and allows remote attackers to conduct cross-site scripting attacks, read cookies that originated from other domains, access the Web VPN session to gain access to internal resources, perform key logging, and conduct other attacks. NOTE: it could be argued that this is a fundamental design problem in any clientless VPN solution, as opposed to a commonly-introduced error that can be fixed in separate implementations. Therefore a single CVE has been assigned for all products that have this design
A vulnerability in the application CLI of Cisco Prime Infrastructure and Cisco Evolved Programmable Network Manager could allow an authenticated, local attacker to gain escalated privileges. This vulnerability is due to improper processing of command line arguments to application scripts. An attacker could exploit this vulnerability by issuing a command on the CLI with malicious options. A successful exploit could allow the attacker to gain the escalated privileges of the root user on the underlying operating system.
A vulnerability in the CLI of Cisco ThousandEyes Enterprise Agent, Virtual Appliance installation type, could allow an authenticated, local attacker to elevate privileges to root on an affected device. This vulnerability is due to insufficient input validation of user-supplied CLI arguments. An attacker could exploit this vulnerability by authenticating to an affected device and using crafted commands at the prompt. A successful exploit could allow the attacker to execute arbitrary commands as root. The attacker must have valid credentials on the affected device.
A vulnerability in the restricted security domain implementation of Cisco Application Policy Infrastructure Controller (APIC) could allow an authenticated, remote attacker to read, modify, or delete non-tenant policies (for example, access policies) created by users associated with a different security domain on an affected system. This vulnerability is due to improper access control when restricted security domains are used to implement multi-tenancy for policies outside the tenant boundaries. An attacker with a valid user account associated with a restricted security domain could exploit this vulnerability. A successful exploit could allow the attacker to read, modify, or delete policies created by users associated with a different security domain. Exploitation is not possible for policies under tenants that an attacker has no authorization to access.
A vulnerability in the access control list (ACL) processing on MPLS interfaces in the ingress direction of Cisco IOS XR Software could allow an unauthenticated, remote attacker to bypass a configured ACL. This vulnerability is due to incomplete support for this feature. An attacker could exploit this vulnerability by attempting to send traffic through an affected device. A successful exploit could allow the attacker to bypass an ACL on the affected device. There are workarounds that address this vulnerability. This advisory is part of the September 2023 release of the Cisco IOS XR Software Security Advisory Bundled Publication. For a complete list of the advisories and links to them, see Cisco Event Response: September 2023 Semiannual Cisco IOS XR Software Security Advisory Bundled Publication .
A vulnerability in Cisco DNA Center could allow an unauthenticated, remote attacker to read and modify data in a repository that belongs to an internal service on an affected device. This vulnerability is due to insufficient access control enforcement on API requests. An attacker could exploit this vulnerability by sending a crafted API request to an affected device. A successful exploit could allow the attacker to read and modify data that is handled by an internal service on the affected device.
A vulnerability in the IP geolocation rules of Snort 3 could allow an unauthenticated, remote attacker to potentially bypass IP address restrictions. This vulnerability exists because the configuration for IP geolocation rules is not parsed properly. An attacker could exploit this vulnerability by spoofing an IP address until they bypass the restriction. A successful exploit could allow the attacker to bypass location-based IP address restrictions.
A vulnerability in the web UI of Cisco Catalyst SD-WAN Manager could allow an authenticated, remote attacker to retrieve arbitrary files from an affected system. This vulnerability is due to improper validation of parameters that are sent to the web UI. An attacker could exploit this vulnerability by logging in to Cisco Catalyst SD-WAN Manager and issuing crafted requests using the web UI. A successful exploit could allow the attacker to obtain arbitrary files from the underlying Linux file system of an affected system. To exploit this vulnerability, the attacker must be an authenticated user.
A vulnerability in Cisco Intersight Virtual Appliance could allow an unauthenticated, adjacent attacker to access internal HTTP services that are otherwise inaccessible. This vulnerability is due to insufficient restrictions on internally accessible http proxies. An attacker could exploit this vulnerability by submitting a crafted CLI command. A successful exploit could allow the attacker access to internal subnets beyond the sphere of their intended access level.
A vulnerability in the Cisco IOx application hosting subsystem of Cisco IOS XE Software could allow an authenticated, local attacker to elevate privileges to root on an affected device. This vulnerability is due to insufficient restrictions on the hosted application. An attacker could exploit this vulnerability by logging in to and then escaping the Cisco IOx application container. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with root privileges.
A vulnerability in the Common Execution Environment (CEE) ConfD CLI of Cisco Ultra Cloud Core - Subscriber Microservices Infrastructure (SMI) software could allow an authenticated, local attacker to escalate privileges on an affected device. This vulnerability is due to insufficient access control in the affected CLI. An attacker could exploit this vulnerability by authenticating as a CEE ConfD CLI user and executing a specific CLI command. A successful exploit could allow an attacker to access privileged containers with root privileges.
A vulnerability in the client forwarding code of multiple Cisco Access Points (APs) could allow an unauthenticated, adjacent attacker to inject packets from the native VLAN to clients within nonnative VLANs on an affected device. This vulnerability is due to a logic error on the AP that forwards packets that are destined to a wireless client if they are received on the native VLAN. An attacker could exploit this vulnerability by obtaining access to the native VLAN and directing traffic directly to the client through their MAC/IP combination. A successful exploit could allow the attacker to bypass VLAN separation and potentially also bypass any Layer 3 protection mechanisms that are deployed.
Multiple vulnerabilities in Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an attacker to escape from the guest virtual machine (VM) to the host machine, inject commands that execute at the root level, or leak system data from the host to the VM. For more information about these vulnerabilities, see the Details section of this advisory.
A vulnerability in the web-based management interface of Cisco AsyncOS for Cisco Content Security Management Appliance (SMA) could allow an unauthenticated, remote attacker to obtain sensitive network information.