A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to execute arbitrary code.
In Schneider Electric U.motion Builder software versions prior to v1.3.4, this exploit occurs when the submitted data of an input string is evaluated as a command by the application. In this way, the attacker could execute code, read the stack, or cause a segmentation fault in the running application.
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, a buffer overflow vulnerability exist in cgi program "set".
In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass.
Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors.
A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
A CWE-798: Use of Hard-coded Credentials vulnerability exists. If an attacker were to obtain the TLS cryptographic key and take active control of the Courier tunneling communication network, they could potentially observe and manipulate traffic associated with product configuration.
A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login.
A Format String: CWE-134 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to send a crafted message to the target server, thereby causing arbitrary commands to be executed.
A CWE-287: Improper Authentication vulnerability exists in the NET55XX Encoder with firmware prior to version 2.1.9.7 which could cause impact to confidentiality, integrity, and availability when a remote attacker crafts a malicious request to the encoder webUI.
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus.
Buffer overflow in an unspecified DLL in Schneider Electric Pelco DS-NVs before 7.8.90 allows remote attackers to execute arbitrary code via unspecified vectors.
A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-2276
A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution.
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `FileUploadServlet` which may lead to uploading executable files to non-specified directories.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.
CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests.
An issue was discovered in Schneider Electric Tableau Server/Desktop Versions 7.0 to 10.1.3 in Wonderware Intelligence Versions 2014R3 and prior. These versions contain a system account that is installed by default. The default system account is difficult to configure with non-default credentials after installation, and changing the default credentials in the embedded Tableau Server is not documented. If Tableau Server is used with Windows integrated security (Active Directory), the software is not vulnerable. However, when Tableau Server is used with local authentication mode, the software is vulnerable. The default system account could be used to gain unauthorized access.
Ceragon FibeAir IP-10 wireless radios through 7.2.0 have a default password of mateidu for the mateidu account (a hidden user account established by the vendor). This account can be accessed via both the web interface and SSH. In the web interface, this simply grants an attacker read-only access to the device's settings. However, when using SSH, this gives an attacker access to a Linux shell. NOTE: the vendor has commented "The mateidu user is a known user, which is mentioned in the FibeAir IP-10 User Guide. Customers are instructed to change the mateidu user password. Changing the user password fully solves the vulnerability."
NetApp AFF A700s Baseboard Management Controller (BMC) firmware versions 1.22 and higher were shipped with a default account enabled that could allow unauthorized arbitrary command execution.
Tieline IP Audio Gateway 2.6.4.8 and below is affected by Incorrect Access Control. A vulnerability in the Tieline Web Administrative Interface could allow an unauthenticated user to access a sensitive part of the system with a high privileged account.
Multiple vulnerabilities in the web-based management interface of the Cisco Catalyst Passive Optical Network (PON) Series Switches Optical Network Terminal (ONT) could allow an unauthenticated, remote attacker to perform the following actions: Log in with a default credential if the Telnet protocol is enabled Perform command injection Modify the configuration For more information about these vulnerabilities, see the Details section of this advisory.
On DTEN D5 and D7 before 1.3.4 devices, factory settings allows for firmware reflash and Android Debug Bridge (adb) enablement.
Silver Peak EdgeConnect SD-WAN before 8.1.7.x has an SNMP service with a public value for rocommunity and trapcommunity.
doorGets 7.0 has a default administrator credential vulnerability. A remote attacker can use this vulnerability to gain administrator privileges for the creation and modification of articles via an H0XZlT44FcN1j9LTdFc5XRXhlF30UaGe1g3cZY6i1K9 access_token in a uri=blog&action=index&controller=blog action to /api/index.php.
An issue was discovered in Alfresco Community Edition versions 6.0 and lower. An unauthenticated, remote attacker could authenticate to Alfresco's Solr Web Admin Interface. The vulnerability is due to the presence of a default private key that is present in all default installations. An attacker could exploit this vulnerability by using the extracted private key and bundling it into a PKCS12. A successful exploit could allow the attacker to gain information about the target system (e.g., OS type, system file locations, Java version, Solr version, etc.) as well as the ability to launch further attacks by leveraging the access to Alfresco's Solr Web Admin Interface.
Undocumented Default Cryptographic Key Vulnerability in Cohesity DataPlatform version 6.3 prior 6.3.1g, 6.4 up to 6.4.1c and 6.5.1 through 6.5.1b. The ssh key can provide an attacker access to the linux system in the affected version.
The SD-WAN Orchestrator 3.3.2, 3.4.x, and 4.0.x has default passwords allowing for a Pass-the-Hash Attack. SD-WAN Orchestrator ships with default passwords for predefined accounts which may lead to to a Pass-the-Hash attack.
The defaults settings for the CORS filter provided in Apache Tomcat 9.0.0.M1 to 9.0.8, 8.5.0 to 8.5.31, 8.0.0.RC1 to 8.0.52, 7.0.41 to 7.0.88 are insecure and enable 'supportsCredentials' for all origins. It is expected that users of the CORS filter will have configured it appropriately for their environment rather than using it in the default configuration. Therefore, it is expected that most users will not be impacted by this issue.
MiR robot controllers (central computation unit) makes use of Ubuntu 16.04.2 an operating system, Thought for desktop uses, this operating system presents insecure defaults for robots. These insecurities include a way for users to escalate their access beyond what they were granted via file creation, access race conditions, insecure home directory configurations and defaults that facilitate Denial of Service (DoS) attacks.
The default configuration of broker.conf in Red Hat OpenShift Enterprise 2.x before 2.1 has a password of "mooo" for a Mongo account, which allows remote attackers to hijack the broker by providing this password, related to the openshift.sh script in Openshift Extras before 20130920. NOTE: this may overlap CVE-2013-4253 and CVE-2013-4281.
On D-Link DIR-550A and DIR-604M devices through v2.10KR, a malicious user can use a default TELNET account to get unauthorized access to vulnerable devices, aka a backdoor access vulnerability.
A vulnerability in the use of JSON web tokens by the web-based service portal of Cisco Elastic Services Controller Software could allow an unauthenticated, remote attacker to gain administrative access to an affected system. The vulnerability is due to the presence of static default credentials for the web-based service portal of the affected software. An attacker could exploit this vulnerability by extracting the credentials from an image of the affected software and using those credentials to generate a valid administrative session token for the web-based service portal of any other installation of the affected software. A successful exploit could allow the attacker to gain administrative access to the web-based service portal of an affected system. This vulnerability affects Cisco Elastic Services Controller Software Release 3.0.0. Cisco Bug IDs: CSCvg30884.
The previous default setting for Airflow's Experimental API was to allow all API requests without authentication, but this poses security risks to users who miss this fact. From Airflow 1.10.11 the default has been changed to deny all requests by default and is documented at https://airflow.apache.org/docs/1.10.11/security.html#api-authentication. Note this change fixes it for new installs but existing users need to change their config to default `[api]auth_backend = airflow.api.auth.backend.deny_all` as mentioned in the Updating Guide: https://github.com/apache/airflow/blob/1.10.11/UPDATING.md#experimental-api-will-deny-all-request-by-default
Lansweeper 6.0.x through 7.2.x has a default installation in which the admin password is configured for the admin account, unless "Built-in admin" is manually unchecked. This allows command execution via the Add New Package and Scheduled Deployments features.