General Electric D20ME devices are not properly configured and reveal plaintext passwords.
GE Fanuc Proficy Real-Time Information Portal 2.6 and earlier uses HTTP Basic Authentication, which transmits usernames and passwords in base64-encoded cleartext and allows remote attackers to steal the passwords and gain privileges.
GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier use the same RSA private key across different customers' installations, which makes it easier for remote attackers to obtain the cleartext content of network traffic by reading this key from a firmware image and then sniffing the network.
GE Mark VIe, EX2100e, EX2100e_Reg, and LS2100e Versions 03.03.28C to 05.02.04C, EX2100e All versions prior to v04.09.00C, EX2100e_Reg All versions prior to v04.09.00C, and LS2100e All versions prior to v04.09.00C The affected versions of the application have a path traversal vulnerability that fails to restrict the ability of an attacker to gain access to restricted information.
Multiple variants of XML External Entity (XXE) attacks may be used to exfiltrate data from the host Windows platform in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior.
GE UR firmware versions prior to version 8.1x web server interface is supported on UR over HTTP protocol. It allows sensitive information exposure without authentication.
GE UR firmware versions prior to version 8.1x shares MODBUS memory map as part of the communications guide. GE was made aware a “Last-key pressed” MODBUS register can be used to gain unauthorized information.
GE Intelligent Platforms Proficy Real-Time Information Portal does not restrict access to methods of an unspecified Java class, which allows remote attackers to obtain a username listing via an RMI call.
The Portal installation process in GE Intelligent Platforms Proficy Real-Time Information Portal stores sensitive information under the web root with insufficient access control, which allows remote attackers to read configuration files, and discover data-source credentials, via a direct request.
GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
GE Infinia/Infinia with Hawkeye 4 medical imaging systems all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
The 17046 Ethernet card before 94450214LFMT100SEM-L.R3-CL for the GE Digital Energy Hydran M2 does not properly generate random values for TCP Initial Sequence Numbers (ISNs), which makes it easier for remote attackers to spoof packets by predicting these values.
GE Digital APM Classic, Versions 4.4 and prior. An insecure direct object reference (IDOR) vulnerability allows user account data to be downloaded in JavaScript object notation (JSON) format by users who should not have access to such functionality. An attacker can download sensitive data related to user accounts without having the proper privileges.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-18411.
By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection.
GE Gas Power ToolBoxST Version v04.07.05C suffers from an XML external entity (XXE) vulnerability using the DTD parameter entities technique that could result in disclosure and retrieval of arbitrary data on the affected node via an out-of-band (OOB) attack. The vulnerability is triggered when input passed to the XML parser is not sanitized while parsing the XML project/template file.
Java remote method invocation (RMI) input port in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior may be exploited to allow unauthenticated users to launch applications and support remote code execution through web services.
GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
SSH server configuration file does not implement some best practices. This could lead to a weakening of the SSH protocol strength, which could lead to additional misconfiguration or be leveraged as part of a larger attack on the MU320E (all firmware versions prior to v04A00.1).
An unauthorized user with network access and the decryption key could decrypt sensitive data, such as usernames and passwords.
An issue was discovered in General Electric (GE) Proficy HMI/SCADA iFIX Version 5.8 SIM 13 and prior versions, Proficy HMI/SCADA CIMPLICITY Version 9.0 and prior versions, and Proficy Historian Version 6.0 and prior versions. An attacker may be able to retrieve user passwords if he or she has access to an authenticated session.
Certain General Electric Renewable Energy products have inadequate encryption strength. This affects iNET and iNET II before 8.3.0.
An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.
An issue was discovered on Humax Digital HG100R 2.0.6 devices. To download the backup file it's not necessary to use credentials, and the router credentials are stored in plaintext inside the backup, aka GatewaySettings.bin.
ownCloud iOS app before 3.4.4 does not properly switch state between multiple instances, which might allow remote instance administrators to obtain sensitive credential and cookie information by reading authentication headers.
The Voo branded NETGEAR CG3700b custom firmware V2.02.03 uses HTTP Basic Authentication over cleartext HTTP.
MyBB (aka MyBulletinBoard) 1.4.2 uses insufficient randomness to compose filenames of uploaded files used as attachments, which makes it easier for remote attackers to read these files by guessing filenames.
Typo 5.1.3 and earlier uses a hard-coded salt for calculating password hashes, which makes it easier for attackers to guess passwords via a brute force attack.
Philips Vue PACS versions 12.2.x.x and prior transmits or stores authentication credentials, but it uses an insecure method susceptible to unauthorized interception and/or retrieval.
KACO New Energy XP100U Up to XP-JAVA 2.0 is affected by incorrect access control. Credentials will always be returned in plain-text from the local server during the KACO XP100U authentication process, regardless of whatever passwords have been provided, which leads to an information disclosure vulnerability.
An attacker could decipher the encryption and gain access to MDT AutoSave versions prior to v6.02.06.
The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00.
Dynacolor FCM-MB40 v1.2.0.0 use /etc/appWeb/appweb.pass to store administrative web-interface credentials in cleartext. These credentials can be retrieved via cgi-bin/getuserinfo.cgi?mode=info.
Lexmark Scan To Network (SNF) 3.2.9 and earlier stores network configuration credentials in plaintext and transmits them in requests, which allows remote attackers to obtain sensitive information via requests to (1) cgi-bin/direct/printer/prtappauth/apps/snfDestServlet or (2) cgi-bin/direct/printer/prtappauth/apps/ImportExportServlet.
Anomali Agave (formerly Drupot) through 1.0.0 fails to avoid fingerprinting by including predictable data and minimal variation in size within HTML templates, giving attackers the ability to detect and avoid this system.
In Gradle Enterprise before 2018.5.3, Build Cache Nodes did not store the credentials at rest in an encrypted format.
Pivotal Reactor Netty, versions prior to 0.8.11, passes headers through redirects, including authorization ones. A remote unauthenticated malicious user may gain access to credentials for a different server than they have access to.
Calamares versions 3.1 through 3.2.10 copies a LUKS encryption keyfile from /crypto_keyfile.bin (mode 0600 owned by root) to /boot within a globally readable initramfs image with insecure permissions, which allows this originally protected file to be read by any user, thereby disclosing decryption keys for LUKS containers created with Full Disk Encryption.
A vulnerability involving insecure storage of sensitive information has been reported to affect QSW-M2116P-2T2S and QNAP switches running QuNetSwitch. If exploited, this vulnerability allows remote attackers to read sensitive information by accessing the unrestricted storage mechanism.We have already fixed this vulnerability in the following versions: QSW-M2116P-2T2S 1.0.6 build 210713 and later QGD-1600P: QuNetSwitch 1.0.6.1509 and later QGD-1602P: QuNetSwitch 1.0.6.1509 and later QGD-3014PT: QuNetSwitch 1.0.6.1519 and later
The Linux kernel 4.x (starting from 4.1) and 5.x before 5.0.8 allows Information Exposure (partial kernel address disclosure), leading to a KASLR bypass. Specifically, it is possible to extract the KASLR kernel image offset using the IP ID values the kernel produces for connection-less protocols (e.g., UDP and ICMP). When such traffic is sent to multiple destination IP addresses, it is possible to obtain hash collisions (of indices to the counter array) and thereby obtain the hashing key (via enumeration). This key contains enough bits from a kernel address (of a static variable) so when the key is extracted (via enumeration), the offset of the kernel image is exposed. This attack can be carried out remotely, by the attacker forcing the target device to send UDP or ICMP (or certain other) traffic to attacker-controlled IP addresses. Forcing a server to send UDP traffic is trivial if the server is a DNS server. ICMP traffic is trivial if the server answers ICMP Echo requests (ping). For client targets, if the target visits the attacker's web page, then WebRTC or gQUIC can be used to force UDP traffic to attacker-controlled IP addresses. NOTE: this attack against KASLR became viable in 4.1 because IP ID generation was changed to have a dependency on an address associated with a network namespace.
Airsonic 10.2.1 uses Spring's default remember-me mechanism based on MD5, with a fixed key of airsonic in GlobalSecurityConfig.java. An attacker able to capture cookies might be able to trivially bruteforce offline the passwords of associated users.
Zebra Industrial Printers All Versions, Zebra printers are shipped with unrestricted end-user access to front panel options. If the option to use a passcode to limit the functionality of the front panel is applied, specially crafted packets could be sent over the same network to a port on the printer and the printer will respond with an array of information that includes the front panel passcode for the printer. Once the passcode is retrieved, an attacker must have physical access to the front panel of the printer to enter the passcode to access the full functionality of the front panel.
TeamPass version 2.1.27 and earlier contains a Storing Passwords in a Recoverable Format vulnerability in Shared password vaults that can result in all shared passwords are recoverable server side. This attack appears to be exploitable via any vulnerability that can bypass authentication or role assignment and can lead to shared password leakage.
GNU Libc current is affected by: Mitigation bypass. The impact is: Attacker may guess the heap addresses of pthread_created thread. The component is: glibc. NOTE: the vendor's position is "ASLR bypass itself is not a vulnerability.
A security regression of CVE-2019-9636 was discovered in python since commit d537ab0ff9767ef024f26246899728f0116b1ec3 affecting versions 2.7, 3.5, 3.6, 3.7 and from v3.8.0a4 through v3.8.0b1, which still allows an attacker to exploit CVE-2019-9636 by abusing the user and password parts of a URL. When an application parses user-supplied URLs to store cookies, authentication credentials, or other kind of information, it is possible for an attacker to provide specially crafted URLs to make the application locate host-related information (e.g. cookies, authentication data) and send them to a different host than where it should, unlike if the URLs had been correctly parsed. The result of an attack may vary based on the application.
Aquaverde GmbH Aquarius CMS prior to version 4.1.1 is affected by: Incorrect Access Control. The impact is: The access to the log file is not restricted. It contains sensitive information like passwords etc. The component is: log file. The attack vector is: open the file.
An Elevation of Privilege vulnerability exists in the way Azure IoT Java SDK generates symmetric keys for encryption, allowing an attacker to predict the randomness of the key, aka 'Azure IoT Java SDK Elevation of Privilege Vulnerability'.
SickRage before v2018.03.09-1 includes cleartext credentials in HTTP responses.
Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. The devices store passwords in plaintext, which may allow an attacker with access to the configuration file to log into the SmartServer web user interface.