The identity authentication bypass vulnerability found in some Dahua products during the login process. Attackers can bypass device identity authentication by constructing malicious data packets.
The identity authentication bypass vulnerability found in some Dahua products during the login process. Attackers can bypass device identity authentication by constructing malicious data packets.
Unspecified vulnerability in SimpleIrcBot before 1.0 Stable has unknown impact and attack vectors related to an "auth vulnerability."
In versions 8.2.1 through 8.5.2 of Pega Infinity, the password reset functionality for local accounts can be used to bypass local authentication checks.
Eaton MGEOPS Network Shutdown Module before 3.10 Build 13 allows remote attackers to execute arbitrary code by adding a custom action to the MGE frontend via pane_actionbutton.php, and then executing this action via exec_action.php.
A vulnerability, which was classified as critical, was found in LB-LINK BL-AC1900, BL-AC2100_AZ3, BL-AC3600, BL-AX1800, BL-AX5400P and BL-WR9000 up to 20250702. Affected is the function reboot/restore of the file /cgi-bin/lighttpd.cgi of the component Web Interface. The manipulation leads to improper authentication. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
userHandler.cgi in RaidSonic ICY BOX NAS firmware 2.3.2.IB.2.RS.1 allows remote attackers to bypass authentication and gain administrator privileges by setting the login parameter to admin. NOTE: the provenance of this information is unknown; the details are obtained solely from third party information.
Improper Authentication vulnerability in S&D smarthome(smartcare) application can cause authentication bypass and information exposure. Remote attackers can use this vulerability to take control of the home environment including indoor control.
Siemens SpeedStream 5200 with NetPort Software 1.1 allows remote attackers to bypass authentication via an invalid Host header, possibly involving a trailing dot in the hostname.
FiberHome VDSL2 Modem HG 150-UB devices allow authentication bypass by ignoring the parent.location='login.html' JavaScript code in the response to an unauthenticated request.
Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. An attacker can bypass the required authentication specified in the security configuration file by including extra characters in the directory name when specifying the directory to be accessed. This vulnerability does not affect the i.LON 600 product.
A remote code execution issue was discovered in the WooCommerce Products Filter (aka WOOF) plugin before 2.2.0 for WordPress, as demonstrated by the shortcode parameter in a woof_redraw_woof action. The plugin implemented a page redraw AJAX function accessible to anyone without any authentication. WordPress shortcode markup in the "shortcode" parameters would be evaluated. Normally unauthenticated users can't evaluate shortcodes as they are often sensitive.
West Wind Web Server 6.x does not require authentication for /ADMIN.ASP.
An authentication bypass vulnerability exists in the Green Electronics RainMachine Mini-8 (2nd Generation) and Touch HD 12 web application allowing an unauthenticated attacker to perform authenticated actions on the device via a 127.0.0.1:port value in the HTTP 'Host' header, as demonstrated by retrieving credentials.
The "Java Update" feature for Java Runtime Environment (JRE) for Sun JDK and JRE 6 Update 10 and earlier; JDK and JRE 5.0 Update 16 and earlier; and SDK and JRE 1.4.2_18 and earlier does not verify the signature of the JRE that is downloaded, which allows remote attackers to execute arbitrary code via DNS man-in-the-middle attacks.
The Password Manager Extension in Abine Blur 7.8.242* before 7.8.2428 allows attackers to bypass the Multi-Factor Authentication and macOS disk-encryption protection mechanisms, and consequently exfiltrate secured data, because the right-click context menu is not secured.
It was discovered that the Unitrends Backup (UB) before 10.1.0 user interface was exposed to an authentication bypass, which then could allow an unauthenticated user to inject arbitrary commands into its /api/hosts parameters using backquotes.
A remote code execution vulnerability was identified in HPE Intelligent Management Center (iMC) prior to iMC PLAT 7.3 E0605P04.
A remote code execution vulnerability was identified in HPE Intelligent Management Center (IMC) PLAT earlier than version 7.3 E0506P09.
Authentication Bypass vulnerability in the administrative user interface in McAfee Web Gateway 7.8.1.0 through 7.8.1.5 allows remote attackers to execute arbitrary code via Java management extensions (JMX).
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could potentially circumvent the authentication mechanism if he/she is able to obtain certain knowledge specific to the attacked device.
A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application allows a cookie parameter to consist of only digits, allowing an attacker to perform a brute force attack bypassing authentication and gaining access to device functions.
A business logic issue in the MStore API WordPress plugin, versions before 3.2.0, had an authentication bypass with Sign In With Apple allowing unauthenticated users to recover an authentication cookie with only an email address.
Login with hash: The login routine allows the client to log in to the system not by using the password, but by using the hash of the password. Combined with CVE-2021-23858, this allows an attacker to subsequently login to the system.
Symantec Ghost Solution Suite 1.1 before 1.1 patch 2, 2.0.0, and 2.0.1 does not authenticate connections between the console and the Ghost Management Agent, which allows remote attackers to execute arbitrary commands via unspecified RPC requests in conjunction with ARP spoofing.
A password hash usage authentication bypass vulnerability in Trend Micro Control Manager 6.0 could allow a remote attacker to bypass authentication on vulnerable installations.
index.php in FTP Admin 0.1.0 allows remote attackers to bypass authentication and obtain administrative access via a loggedin parameter with a value of true, as demonstrated by adding a user account.
Podcast Producer in Apple Mac OS X 10.5 before 10.5.6 allows remote attackers to bypass authentication and gain administrative access via unspecified vectors.
The Thomson/Alcatel SpeedTouch 7G router, as used for the BT Home Hub 6.2.6.B and earlier, allows remote attackers on an intranet to bypass authentication and gain administrative access via vectors including a '/' (slash) character at the end of the PATH_INFO to cgi/b, aka "double-slash auth bypass." NOTE: remote attackers outside the intranet can exploit this by leveraging a separate CSRF vulnerability. NOTE: SpeedTouch 780 might also be affected by some of these issues.
IBM BigFix Remote Control before 9.1.3 does not properly restrict failed login attempts, which makes it easier for remote attackers to obtain access via a brute-force approach.
Kentix MultiSensor-LAN 5.63.00 devices and previous allow Authentication Bypass via an Alternate Path or Channel.
Cobham Satcom Sailor 250 and 500 devices before 1.25 contained an unauthenticated password reset vulnerability. This could allow modification of any user account's password (including the default "admin" account), without prior knowledge of their password. All that is required is knowledge of the username and attack vector (/index.lua?pageID=Administration usernameAdmChange, passwordAdmChange1, and passwordAdmChange2 fields).
servermgrd (Server Manager) in Apple Mac OS X 10.5.6 does not properly validate authentication credentials, which allows remote attackers to modify the system configuration.
The TIBCO Spotfire authentication component of TIBCO Software Inc.'s TIBCO Spotfire Analytics Platform for AWS Marketplace, and TIBCO Spotfire Server contains a vulnerability in the handling of the authentication that theoretically may allow an attacker to gain full access to a target account, independent of configured authentication mechanisms. Affected releases are TIBCO Software Inc. TIBCO Spotfire Analytics Platform for AWS Marketplace: versions up to and including 10.0.0, and TIBCO Spotfire Server: versions up to and including 7.10.1; 7.11.0; 7.11.1; 7.12.0; 7.13.0; 7.14.0.
An Authentication Bypass issue exists in Solutions Business Manager (SBM) (formerly Serena Business Manager (SBM)) versions prior to 11.5.
A command execution vulnerability in SonicWall GMS 9.3 allows a remote unauthenticated attacker to locally escalate privilege to root.
Unauthentication vulnerabilities have been identified in Geutebruck G-Cam/EFD-2250 Version 1.12.0.4 and Topline TopFD-2125 Version 3.15.1 IP cameras, which may allow remote code execution.
The SSH server implementation of AsyncSSH before 1.12.1 does not properly check whether authentication is completed before processing other requests. A customized SSH client can simply skip the authentication step.
Unsecured way of firmware update in Hanwha Techwin Smartcams
Due to incorrect access control in Neo4j Enterprise Database Server 3.4.x before 3.4.9, the setting of LDAP for authentication with STARTTLS, and System Account for authorization, allows an attacker to log into the server by sending any valid username with an arbitrary password.
Cybozu Garoon before 4.2.2 allows remote attackers to bypass login authentication via vectors related to API use.
Circontrol CirCarLife all versions prior to 4.3.1, authentication to the device can be bypassed by entering the URL of a specific page.
Aruba ClearPass, all versions of 6.6.x prior to 6.6.9 are affected by an authentication bypass vulnerability, an attacker can leverage this vulnerability to gain administrator privileges on the system. The vulnerability is exposed only on ClearPass web interfaces, including administrative, guest captive portal, and API. Customers who do not expose ClearPass web interfaces to untrusted users are impacted to a lesser extent.
An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455.
The XML API in TelePresence Codec (TC) 7.2.0, 7.2.1, 7.3.0, 7.3.1, 7.3.2, 7.3.3, 7.3.4, and 7.3.5 and Collaboration Endpoint (CE) 8.0.0, 8.0.1, and 8.1.0 in Cisco TelePresence Software mishandles authentication, which allows remote attackers to execute control commands or make configuration changes via an API request, aka Bug ID CSCuz26935.
ZUUSE BEIMS ContractorWeb .NET 5.18.0.0 allows access to various /UserManagement/ privileged modules without authenticating the user; an attacker can misuse these functionalities to perform unauthorized actions, as demonstrated by Edit User Details.
When attempting to allow authentication mode `try` in hapi, hapi-auth-jwt2 version 5.1.1 introduced an issue whereby people could bypass authentication.
In the GUI of Ceragon FibeAir IP-10 (before 7.2.0) devices, a remote attacker can bypass authentication by adding an ALBATROSS cookie with the value 0-4-11 to their browser.
ProjectSend (formerly cFTP) r582 allows authentication bypass via a direct request for users.php, home.php, edit-file.php?file_id=1, or process-zip-download.php, or add_user_form_* parameters to users-add.php.
The Axesstel AXW-D800 modem with D2_ETH_109_01_VEBR Jun-14-2006 software does not require authentication for (1) etc/config/System.html, (2) etc/config/Network.html, (3) etc/config/Security.html, (4) cgi-bin/sysconf.cgi, and (5) cgi-bin/route.cgi, which allows remote attackers to change the modem's configuration via direct requests.