A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution.
Eaton 9000X DriveA versions 2.0.29 and prior has a stack-based buffer overflow vulnerability, which may allow remote code execution.
For Crestron TSW-X60 version prior to 2.001.0037.001 and MC3 version prior to 1.502.0047.001, The devices are shipped with authentication disabled, and there is no indication to users that they need to take steps to enable it. When compromised, the access to the CTP console is left open.
PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted.
Moxa IKS and EDS generate a predictable cookie calculated with an MD5 hash, allowing an attacker to capture the administrator's password, which could lead to a full compromise of the device.
Moxa IKS and EDS do not implement sufficient measures to prevent multiple failed authentication attempts, which may allow an attacker to discover passwords via brute force attack.
AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update. Code is executed under the program runtime privileges, which could lead to the compromise of the machine.
Several buffer overflow vulnerabilities have been identified in Moxa IKS and EDS, which may allow remote code execution.
gpsd versions 2.90 to 3.17 and microjson versions 1.0 to 1.3, an open source project, allow a stack-based buffer overflow, which may allow remote attackers to execute arbitrary code on embedded platforms via traffic on Port 2947/TCP or crafted JSON inputs.
CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has multiple stack-based buffer overflow vulnerabilities that could cause the software to crash due to lacking user input validation before copying data from project files onto the stack. Which may allow an attacker to gain remote code execution with administrator privileges if exploited.
Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior, CX-Server versions 5.0.22 and prior, Network Configurator versions 3.63 and prior, and Switch Box Utility versions 1.68 and prior, may cause a stack-based buffer overflow.
DeltaV Versions 11.3.1, 12.3.1, 13.3.0, 13.3.1, and R5 is vulnerable to a buffer overflow exploit through an open communication port to allow arbitrary code execution.
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an "echo" service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow.
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to access memory ("write-what-where") from an attacker-chosen device address within the same subnet.
Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network packets via a specific network port, causing the buffer to be overwritten. This may allow remote code execution, cause the application to crash, or result in a denial-of-service condition in the application server.
A memory corruption vulnerability has been identified in WECON LeviStudioU version 1.8.56 and prior, which may allow arbitrary code execution. Mat Powell, Ziad Badawi, and Natnael Samson working with Trend Micro's Zero Day Initiative, reported these vulnerabilities to NCCIC.
Multiple stack-based buffer overflow vulnerabilities in WECON LeviStudioU version 1.8.56 and prior may be exploited when parsing strings within project files. The process does not properly validate the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage these vulnerabilities to execute code under the context of the current process. Mat Powell, Ziad Badawi, and Natnael Samson working with Trend Micro's Zero Day Initiative, reported these vulnerabilities to NCCIC.
Several heap-based buffer overflow vulnerabilities in WECON LeviStudioU version 1.8.56 and prior have been identified, which may allow arbitrary code execution. Mat Powell, Ziad Badawi, and Natnael Samson working with Trend Micro's Zero Day Initiative, reported these vulnerabilities to NCCIC.
Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior, CX-Server versions 5.0.22 and prior, Network Configurator versions 3.63 and prior, and Switch Box Utility versions 1.68 and prior, may cause a heap-based buffer overflow.
Heap-based buffer overflow vulnerabilities in Advantech WebAccess HMI Designer 2.1.7.32 and prior caused by processing specially crafted .pm3 files may allow remote code execution.
In Omron CX-Supervisor Versions 3.30 and prior, parsing malformed project files may cause a stack-based buffer overflow.
WPLSoft in Delta Electronics versions 2.45.0 and prior utilizes a fixed length stack buffer where a value larger than the buffer can be read from a file into the buffer, causing the buffer to be overwritten, which may allow remote code execution or cause the application to crash.
WPLSoft in Delta Electronics versions 2.45.0 and prior writes data from a file outside the bounds of the intended buffer space, which could cause memory corruption or may allow remote code execution.
In Omron CX-Supervisor Versions 3.30 and prior, parsing malformed project files may cause a heap-based buffer overflow.
In Omron CX-Supervisor Versions 3.30 and prior, parsing malformed project files may cause an out of bounds vulnerability.
Processing specially crafted .pm3 files in Advantech WebAccess HMI Designer 2.1.7.32 and prior may cause the system to write outside the intended buffer area and may allow remote code execution.
An exploitable code execution vulnerability exists in the HTTP request-parsing function of the NT9665X Chipset firmware running on the Anker Roav A1 Dashcam, version RoavA1SWV1.9. A specially crafted packet can cause an unlimited and arbitrary write to memory, resulting in code execution.
Adobe Acrobat and Reader 2018.011.20040 and earlier, 2017.011.30080 and earlier, and 2015.006.30418 and earlier versions have an Out-of-bounds write vulnerability. Successful exploitation could lead to arbitrary code execution in the context of the current user.
Adobe Acrobat and Reader versions 2018.011.20038 and earlier, 2017.011.30079 and earlier, and 2015.006.30417 and earlier have a Heap Overflow vulnerability. Successful exploitation could lead to arbitrary code execution in the context of the current user.
Adobe Acrobat and Reader versions 2018.011.20038 and earlier, 2017.011.30079 and earlier, and 2015.006.30417 and earlier have a Heap Overflow vulnerability. Successful exploitation could lead to arbitrary code execution in the context of the current user.
An exploitable code execution vulnerability exists in Wi-Fi Command 9999 of the Roav A1 Dashcam running version RoavA1SWV1.9. A specially crafted packet can cause a stack-based buffer overflow, resulting in code execution. An attacker can send a packet to trigger this vulnerability.
An issue was discovered in Adobe Acrobat Reader 2018.009.20050 and earlier versions, 2017.011.30070 and earlier versions, 2015.006.30394 and earlier versions. The vulnerability is caused by the computation that writes data past the end of the intended buffer; the computation is part of the image conversion engine when processing Enhanced Metafile Format Plus (EMF+) data. An attacker can potentially leverage the vulnerability to corrupt sensitive data or execute arbitrary code.
Adobe Acrobat and Reader versions 2018.011.20038 and earlier, 2017.011.30079 and earlier, and 2015.006.30417 and earlier have a Heap Overflow vulnerability. Successful exploitation could lead to arbitrary code execution in the context of the current user.
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formWifiWpsStart.
Adobe Acrobat and Reader 2018.011.20040 and earlier, 2017.011.30080 and earlier, and 2015.006.30418 and earlier versions have an Out-of-bounds write vulnerability. Successful exploitation could lead to arbitrary code execution in the context of the current user.
Adobe Acrobat and Reader versions 2018.009.20050 and earlier, 2017.011.30070 and earlier, 2015.006.30394 and earlier have an exploitable out-of-bounds write vulnerability. Successful exploitation could lead to arbitrary code execution in the context of the current user.
Adobe Acrobat and Reader versions 2018.011.20038 and earlier, 2017.011.30079 and earlier, and 2015.006.30417 and earlier have a Heap Overflow vulnerability. Successful exploitation could lead to arbitrary code execution in the context of the current user.
A vulnerability was detected in D-Link DIR-816L 2_06_b09_beta. Affected by this vulnerability is the function authenticationcgi_main of the file /authentication.cgi. Performing manipulation of the argument Password results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is now public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
Adobe Acrobat and Reader 2018.011.20040 and earlier, 2017.011.30080 and earlier, and 2015.006.30418 and earlier versions have an Out-of-bounds write vulnerability. Successful exploitation could lead to arbitrary code execution in the context of the current user.
Adobe Acrobat and Reader versions 2018.009.20050 and earlier, 2017.011.30070 and earlier, 2015.006.30394 and earlier have an exploitable heap overflow vulnerability. Successful exploitation could lead to arbitrary code execution in the context of the current user.
Adobe Acrobat and Reader 2018.011.20040 and earlier, 2017.011.30080 and earlier, and 2015.006.30418 and earlier versions have an Out-of-bounds write vulnerability. Successful exploitation could lead to arbitrary code execution in the context of the current user.
Adobe Flash Player versions 29.0.0.171 and earlier have a Stack-based buffer overflow vulnerability. Successful exploitation could lead to arbitrary code execution in the context of the current user.
An exploitable code execution vulnerability exists in the XML_UploadFile Wi-Fi command of the NT9665X Chipset firmware, running on the Anker Roav A1 Dashcam, version RoavA1SWV1.9. A specially crafted packet can cause a stack-based buffer overflow, resulting in code execution.
A vulnerability has been identified in RUGGEDCOM i800 (All versions < V4.3.7), RUGGEDCOM i801 (All versions < V4.3.7), RUGGEDCOM i802 (All versions < V4.3.7), RUGGEDCOM i803 (All versions < V4.3.7), RUGGEDCOM M2100 (All versions < V4.3.7), RUGGEDCOM M2200 (All versions < V4.3.7), RUGGEDCOM M969 (All versions < V4.3.7), RUGGEDCOM RMC30 (All versions < V4.3.7), RUGGEDCOM RMC8388 V4.X (All versions < V4.3.7), RUGGEDCOM RMC8388 V5.X (All versions < V5.5.4), RUGGEDCOM RP110 (All versions < V4.3.7), RUGGEDCOM RS1600 (All versions < V4.3.7), RUGGEDCOM RS1600F (All versions < V4.3.7), RUGGEDCOM RS1600T (All versions < V4.3.7), RUGGEDCOM RS400 (All versions < V4.3.7), RUGGEDCOM RS401 (All versions < V4.3.7), RUGGEDCOM RS416 (All versions < V4.3.7), RUGGEDCOM RS416P (All versions < V4.3.7), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.7), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.5.4), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.7), RUGGEDCOM RS416v2 V5.X (All versions < 5.5.4), RUGGEDCOM RS8000 (All versions < V4.3.7), RUGGEDCOM RS8000A (All versions < V4.3.7), RUGGEDCOM RS8000H (All versions < V4.3.7), RUGGEDCOM RS8000T (All versions < V4.3.7), RUGGEDCOM RS900 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RS900G (All versions < V4.3.7), RUGGEDCOM RS900G (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RS900GP (All versions < V4.3.7), RUGGEDCOM RS900L (All versions < V4.3.7), RUGGEDCOM RS900W (All versions < V4.3.7), RUGGEDCOM RS910 (All versions < V4.3.7), RUGGEDCOM RS910L (All versions < V4.3.7), RUGGEDCOM RS910W (All versions < V4.3.7), RUGGEDCOM RS920L (All versions < V4.3.7), RUGGEDCOM RS920W (All versions < V4.3.7), RUGGEDCOM RS930L (All versions < V4.3.7), RUGGEDCOM RS930W (All versions < V4.3.7), RUGGEDCOM RS940G (All versions < V4.3.7), RUGGEDCOM RS969 (All versions < V4.3.7), RUGGEDCOM RSG2100 (All versions < V4.3.7), RUGGEDCOM RSG2100 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RSG2100P (All versions < V4.3.7), RUGGEDCOM RSG2100P (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RSG2200 (All versions < V4.3.7), RUGGEDCOM RSG2288 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2288 V5.X (All versions < V5.5.4), RUGGEDCOM RSG2300 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2300 V5.X (All versions < V5.5.4), RUGGEDCOM RSG2300P V4.X (All versions < V4.3.7), RUGGEDCOM RSG2300P V5.X (All versions < V5.5.4), RUGGEDCOM RSG2488 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2488 V5.X (All versions < V5.5.4), RUGGEDCOM RSG907R (All versions < V5.5.4), RUGGEDCOM RSG908C (All versions < V5.5.4), RUGGEDCOM RSG909R (All versions < V5.5.4), RUGGEDCOM RSG910C (All versions < V5.5.4), RUGGEDCOM RSG920P V4.X (All versions < V4.3.7), RUGGEDCOM RSG920P V5.X (All versions < V5.5.4), RUGGEDCOM RSL910 (All versions < V5.5.4), RUGGEDCOM RST2228 (All versions < V5.5.4), RUGGEDCOM RST2228P (All versions < V5.5.4), RUGGEDCOM RST916C (All versions < V5.5.4), RUGGEDCOM RST916P (All versions < V5.5.4). The DHCP client in affected devices fails to properly sanitize incoming DHCP packets. This could allow an unauthenticated remote attacker to cause memory to be overwritten, potentially allowing remote code execution.
In mjs_json.c in Cesanta MongooseOS mJS 1.26, a maliciously formed JSON string can trigger an off-by-one heap-based buffer overflow in mjs_json_parse, which can potentially lead to redirection of control flow. NOTE: the original reporter disputes the significance of this finding because "there isn’t very much of an opportunity to exploit this reliably for an information leak, so there isn’t any real security impact."
A vulnerability has been found in D-Link DIR-816L 2_06_b09_beta. This affects the function genacgi_main of the file gena.cgi. The manipulation of the argument SERVER_ID/HTTP_SID leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability was determined in D-Link DIR-816L 2_06_b09_beta. This issue affects the function soapcgi_main of the file /soap.cgi. This manipulation causes stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized. This vulnerability only affects products that are no longer supported by the maintainer.
Out-of-bounds Write vulnerability in ixray-team ixray-1.6-stcop.This issue affects ixray-1.6-stcop: before 1.3.
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterDatabase()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
A vulnerability has been found in Tenda W12 3.0.0.6(3948). The affected element is the function wifiMacFilterSet of the file /goform/modules of the component HTTP Request Handler. The manipulation of the argument mac leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used.