SQL injection vulnerability in the RICOH Interactive Whiteboard D2200 V1.3 to V2.2, D5500 V1.3 to V2.2, D5510 V1.3 to V2.2, the display versions with RICOH Interactive Whiteboard Controller Type1 V1.3 to V2.2 attached (D5520, D6500, D6510, D7500, D8400), and the display versions with RICOH Interactive Whiteboard Controller Type2 V3.0 to V3.1.10137.0 attached (D5520, D6510, D7500, D8400) allows remote attackers to execute arbitrary SQL commands via unspecified vectors.
RICOH Interactive Whiteboard D2200 V1.6 to V2.2, D5500 V1.6 to V2.2, D5510 V1.6 to V2.2, and the display versions with RICOH Interactive Whiteboard Controller Type1 V1.6 to V2.2 attached (D5520, D6500, D6510, D7500, D8400) allows remote attackers to execute arbitrary commands via unspecified vectors.
RICOH Printer series SP products 320DN, SP 325DNw, SP 320SN, SP 320SFN, SP 325SNw, SP 325SFNw, SP 330SN, Aficio SP 3500SF, SP 221S, SP 220SNw, SP 221SNw, SP 221SF, SP 220SFNw, SP 221SFNw v1.06 were discovered to contain a stack buffer overflow in the file /etc/wpa_supplicant.conf. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data.
Several Ricoh printers have multiple buffer overflows parsing LPD packets, which allow an attacker to cause a denial of service or code execution via crafted requests to the LPD service. Affected firmware versions depend on the printer models. One affected configuration is cpe:2.3:o:ricoh:sp_c250dn_firmware:-:*:*:*:*:*:*:* up to (including) 1.06 running on cpe:2.3:o:ricoh:sp_c250dn:-:*:*:*:*:*:*:*, cpe:2.3:o:ricoh:sp_c252dn:-:*:*:*:*:*:*:*. Another affected configuration is cpe:2.3:o:ricoh:sp_c250sf_firmware:-:*:*:*:*:*:*:* up to (including) 1.12 running on cpe:2.3:o:ricoh:sp_c250sf:-:*:*:*:*:*:*:*, cpe:2.3:o:ricoh:sp_c252sf:-:*:*:*:*:*:*:*.
Several Ricoh printers have multiple buffer overflows parsing HTTP cookie headers, which allow an attacker to cause a denial of service or code execution via crafted requests to the web server. Affected firmware versions depend on the printer models. One affected configuration is cpe:2.3:o:ricoh:sp_c250dn_firmware:-:*:*:*:*:*:*:* up to (including) 1.06 running on cpe:2.3:o:ricoh:sp_c250dn:-:*:*:*:*:*:*:*, cpe:2.3:o:ricoh:sp_c252dn:-:*:*:*:*:*:*:*. Another affected configuration is cpe:2.3:o:ricoh:sp_c250sf_firmware:-:*:*:*:*:*:*:* up to (including) 1.12 running on cpe:2.3:o:ricoh:sp_c250sf:-:*:*:*:*:*:*:*, cpe:2.3:o:ricoh:sp_c252sf:-:*:*:*:*:*:*:*.
Several Ricoh printers have multiple buffer overflows parsing HTTP parameter settings for Wi-Fi, mDNS, POP3, SMTP, and notification alerts, which allow an attacker to cause a denial of service or code execution via crafted requests to the web server. Affected firmware versions depend on the printer models. One affected configuration is cpe:2.3:o:ricoh:sp_c250dn_firmware:-:*:*:*:*:*:*:* up to (including) 1.06 running on cpe:2.3:o:ricoh:sp_c250dn:-:*:*:*:*:*:*:*, cpe:2.3:o:ricoh:sp_c252dn:-:*:*:*:*:*:*:*. Another affected configuration is cpe:2.3:o:ricoh:sp_c250sf_firmware:-:*:*:*:*:*:*:* up to (including) 1.12 running on cpe:2.3:o:ricoh:sp_c250sf:-:*:*:*:*:*:*:*, cpe:2.3:o:ricoh:sp_c252sf:-:*:*:*:*:*:*:*.
Several Ricoh printers have multiple buffer overflows parsing HTTP parameter settings for SNMP, which allow an attacker to cause a denial of service or code execution via crafted requests to the web server. Affected firmware versions depend on the printer models. One affected configuration is cpe:2.3:o:ricoh:sp_c250dn_firmware:-:*:*:*:*:*:*:* up to (including) 1.06 running on cpe:2.3:o:ricoh:sp_c250dn:-:*:*:*:*:*:*:*, cpe:2.3:o:ricoh:sp_c252dn:-:*:*:*:*:*:*:*. Another affected configuration is cpe:2.3:o:ricoh:sp_c250sf_firmware:-:*:*:*:*:*:*:* up to (including) 1.12 running on cpe:2.3:o:ricoh:sp_c250sf:-:*:*:*:*:*:*:*, cpe:2.3:o:ricoh:sp_c252sf:-:*:*:*:*:*:*:*.
Buffer overflow in Ricoh DL FTP Server 1.1.0.6 and earlier allows remote attackers to execute arbitrary code via a long USER command.
RICOH Interactive Whiteboard D2200 V1.1 to V2.2, D5500 V1.1 to V2.2, D5510 V1.1 to V2.2, the display versions with RICOH Interactive Whiteboard Controller Type1 V1.1 to V2.2 attached (D5520, D6500, D6510, D7500, D8400), and the display versions with RICOH Interactive Whiteboard Controller Type2 V3.0 to V3.1.10137.0 attached (D5520, D6510, D7500, D8400) uses hard-coded credentials, which may allow an attacker on the same network segments to login to the administrators settings screen and change the configuration.
Ricoh SP C250DN 1.05 devices have a fixed password. FTP service credential were found to be hardcoded within the printer firmware. This would allow to an attacker to access and read information stored on the shared FTP folders.
Use of hard-coded credentials issue exists in Ricoh Streamline NX PC Client ver.3.7.2 and earlier. If this vulnerability is exploited, an attacker may obtain LocalSystem Account of the PC where the product is installed. As a result, unintended operations may be performed on the PC.
ZModo ZP-NE14-S and ZP-IBH-13W devices have a hardcoded root password, which makes it easier for remote attackers to obtain access via a TELNET session.
Juniper ATP ships with hard coded credentials in the Cyphort Core instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3.
Juniper ATP ships with hard coded credentials in the Web Collector instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3.
The installation of Microsoft Exchange 2000 before Rev. A creates a user account with a known password, which could allow attackers to gain privileges, aka the "Exchange User Account" vulnerability.
A low privileged admin account with a weak default password of admin exists on the Foxconn FEMTO AP-FC4064-T AP_GT_B38_5.8.3lb15-W47 LTE Build 15. In addition, its web management page relies on the existence or values of cookies when performing security-critical operations. One can gain privileges by modifying cookies.
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data.
An issue was discovered on MOBOTIX S14 MX-V4.2.1.61 devices. There is a default password of meinsm for the admin account.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.
ExaGrid appliances with firmware before 4.8 P26 have a default password of (1) inflection for the root shell account and (2) support for the support account in the web interface, which allows remote attackers to obtain administrative access via an SSH or HTTP session.
A vulnerability in Brocade Network Advisor Version Before 14.3.1 could allow an unauthenticated, remote attacker to log in to the JBoss Administration interface of an affected system using an undocumented user credentials and install additional JEE applications.
An issue was discovered on VOBOT CLOCK before 0.99.30 devices. An SSH server exists with a hardcoded vobot account that has root access.
iBall iB-WRA150N 1.2.6 build 110401 Rel.47776n devices have a hardcoded password of admin for the admin account, a hardcoded password of support for the support account, and a hardcoded password of user for the user account.
An issue was discovered in the MBeans Server in Wowza Streaming Engine before 4.7.1. The file system may be read and written to via JMX using the default JMX credentials (remote code execution may be possible as well).
The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running. The Dropbear server is configured with a hard-coded user name and password combination of root / amroot. The server is configured to use password only authentication not cryptographic keys, however the firmware image contains an RSA host-key for the server. An attacker can exploit this vulnerability to gain root access to the Angstrom Linux operating system and modify any binaries or configuration files in the firmware. Affected releases are Auto-Maskin DCU-210E RP-210E: Versions prior to 3.7 on ARMv7.
backupmgt/pre_connect_check.php in Seagate BlackArmor NAS contains a hard-coded password of '!~@##$$%FREDESWWSED' for a backdoor user.
MASTER IPCAMERA01 3.3.4.2103 devices have a hardcoded password of cat1029 for the root account.
Siklu EtherHaul radios before 3.7.1 and 6.x before 6.9.0 have a built-in, hidden root account, with an unchangeable password that is the same across all devices. This account is accessible via both SSH and the device's web interface and grants access to the underlying embedded Linux OS on the device, allowing full control over it.
A remote, unauthenticated attacker can gain remote code execution on the the Tenda AC15 router with a specially crafted password parameter for the COOKIE header.
Trango Altum AC600 devices have a built-in, hidden root account, with a default password of abcd1234. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). A factory account with hardcoded password might allow attackers access to the device over port 5900/tcp. Successful exploitation requires no user interaction or privileges and impacts the confidentiality, integrity, and availability of the affected device. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
Meross MSS110 devices before 1.1.24 contain a TELNET listener providing access for an undocumented admin account with a blank password.
NETGEAR Arlo base stations with firmware 1.7.5_6178 and earlier, Arlo Q devices with firmware 1.8.0_5551 and earlier, and Arlo Q Plus devices with firmware 1.8.1_6094 and earlier have a default password of 12345678, which makes it easier for remote attackers to obtain access after a factory reset or in a factory configuration.
The Fedora Nagios package uses "nagiosadmin" as the default password for the "nagiosadmin" administrator account, which makes it easier for remote attackers to obtain access by leveraging knowledge of the credentials.
A Hard-coded Credentials vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable an attacker to gain access to the device.
Datto ALTO and SIRIS devices have a default VNC password.
In the web server on D-Link DIR-620 devices with a certain customized (by ISP) variant of firmware 1.0.3, 1.0.37, 1.3.1, 1.3.3, 1.3.7, 1.4.0, and 2.0.22, there is a hardcoded password of anonymous for the admin account.
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded.
A vulnerability has been found in E-Lins H685, H685f, H700, H720, H750, H820, H820Q, H820Q0 and H900 up to 3.2 and classified as critical. This vulnerability affects unknown code of the component OEM Backend. The manipulation leads to hard-coded credentials. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. It is recommended to change the configuration settings. The vendor was contacted early about this disclosure but did not respond in any way.
Certain NETGEAR devices are affected by a hardcoded password. This affects D3600 before 1.0.0.76 and D6000 before 1.0.0.76.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. There is a hardcoded Ak47@99 password for the factory~ account.
IBM Security Identity Governance and Intelligence 5.2 through 5.2.4.1 Virtual Appliance contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 153386.
Hard coded weak credentials in Barracuda Load Balancer 5.0.0.015.
LCDS Laquis SCADA prior to version 4.1.0.4150 uses hard coded credentials, which may allow an attacker unauthorized access to the system with high privileges.
A vulnerability in the Telnet service of Cisco Small Business RV110W Wireless-N VPN Firewall Routers could allow an unauthenticated, remote attacker to take full control of the device with a high-privileged account. The vulnerability exists because a system account has a default and static password. An attacker could exploit this vulnerability by using this default account to connect to the affected system. A successful exploit could allow the attacker to gain full control of an affected device.
A hidden backdoor on PATLITE NH-FB Series devices with firmware version 1.45 or earlier, NH-FV Series devices with firmware version 1.10 or earlier, and NBM Series devices with firmware version 1.09 or earlier allow attackers to enable an SSH daemon via the "kankichi" or "kamiyo4" password to the _secret1.htm URI. Subsequently, the default password of root for the root account allows an attacker to conduct remote code execution and as a result take over the system.
NUUO CMS all versions 3.1 and prior, The application creates default accounts that have hard-coded passwords, which could allow an attacker to gain privileged access.
Deltek Vision 7.x before 7.6 permits the execution of any attacker supplied SQL statement through a custom RPC over HTTP protocol. The Vision system relies on the client binary to enforce security rules and integrity of SQL statements and other content being sent to the server. Client HTTP calls can be manipulated by one of several means to execute arbitrary SQL statements (similar to SQLi) or possibly have unspecified other impact via this custom protocol. To perform these attacks an authenticated session is first required. In some cases client calls are obfuscated by encryption, which can be bypassed due to hard-coded keys and an insecure key rotation protocol. Impacts may include remote code execution in some deployments; however, the vendor states that this cannot occur when the installation documentation is heeded.
Allegra Hard-coded Credentials Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Allegra. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of a database. The issue results from the use of a hardcoded password. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-22360.