SQL injection vulnerability in summary.php in Xerox Fiery Webtools allows remote attackers to execute arbitrary SQL commands via the select parameter.
Xerox AltaLink B80xx before 103.008.020.23120, C8030/C8035 before 103.001.020.23120, C8045/C8055 before 103.002.020.23120 and C8070 before 103.003.020.23120 has several SQL injection vulnerabilities.
Unknown vulnerability in Xerox MicroServer Web Server in Document Centre 220 through 265, 332 and 340, 420 through 490, and 535 through 555 allows remote attackers to bypass authentication.
The default configuration of Xerox DocuTech 6110 and DocuTech 6115 running Solaris 8.0 has a large number of unnecessary services enabled such as RPC and sprayd, which could allow remote attackers to obtain access to the device.
The default configurations for DocuTech 6110 and DocuTech 6115 have a default administrative password of (1) "service!" on Solaris 8.0 or (2) "administ" on Windows NT, which allows remote attackers to gain privileges.
Unspecified vulnerability in the Web User Interface in Xerox WorkCentre and WorkCentre Pro before 12.050.03.000, 13.x before 13.050.03.000, and 14.x before 14.050.03.000 allows remote attackers to bypass authentication controls via unknown vectors.
The Web User Interface in Xerox WorkCentre and WorkCentre Pro before 12.060.17.000, 13.x before 13.060.17.000, and 14.x before 14.060.17.000 allows remote attackers to execute arbitrary commands via unspecified vectors involving "command injection" in (1) the TCP/IP hostname, (2) Scan-to-mailbox folder names, and (3) certain parameters in the Microsoft Networking configuration. NOTE: vector 1 might be the same as CVE-2006-5290.
Xerox WorkCentre and WorkCentre Pro before 12.060.17.000, 13.x before 13.060.17.000, and 14.x before 14.060.17.000 allow remote attackers to gain access via unspecified vectors related to "browser permissions."
Xerox AtlaLink B8045/B8055/B8065/B8075/B8090 C8030/C8035/C8045/C8055/C8070 printers with software before 101.00x.089.22600 allow an attacker to gain privileges.
Xerox AltaLink B8045/B8055/B8065/B8075/B8090, AltaLink C8030/C8035/C8045/C8055/C8070 with software releases before 103.xxx.030.32000 includes two accounts with weak hard-coded passwords which can be exploited and allow unauthorized access which cannot be disabled.
An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is unauthenticated Remote Command Execution.
The web application on Xerox AltaLink B80xx before 100.008.028.05200, C8030/C8035 before 100.001.028.05200, C8045/C8055 before 100.002.028.05200, and C8070 before 100.003.028.05200 allows unauthenticated command injection.
The SNMP implementation in Xerox WorkCentre and WorkCentre Pro before 12.050.03.000, 13.x before 13.050.03.000, and 14.x before 14.050.03.000 does not generate authentication failure traps, which allows remote attackers to more easily gain system access and obtain sensitive information via a brute force attack.
Multiple unspecified vulnerabilities in Xerox WorkCentre and WorkCentre Pro before 12.050.03.000, 13.x before 13.050.03.000, and 14.x before 14.050.03.000 allow remote attackers to have an unspecified impact via unspecified vectors relating to "HTTP Security issues."
The ESS/ Network Controller and MicroServer Web Server components of Xerox WorkCentre and WorkCentre Pro 232, 238, 245, 255, 265 and 275 allow remote attackers to bypass authentication and execute arbitrary code via "WebUI command injection on TCP/IP hostname."
Within multiple XEROX products a vulnerability allows remote command execution on the Linux system, as the "nobody" user through a crafted "HTTP" request (OS Command Injection vulnerability in the HTTP interface). Depending upon configuration authentication may not be necessary.
Xerox Phaser 4622 v35.013.01.000 was discovered to contain a buffer overflow in the function sub_3226AC via the TIMEZONE variable. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data.
Multiple unspecified vulnerabilities in ESS/ Network Controller and MicroServer Web Server in Xerox WorkCentre Pro and Xerox WorkCentre running software 13.027.24.015 and 14.027.24.015 allow remote attackers to bypass authentication or gain "unauthorized network access" via unknown attack vectors.
Multiple unknown vulnerabilities in the MicroServer Web Server for Xerox WorkCentre Pro Color 2128, 2636, and 3545, version 0.001.04.044 through 0.001.04.504, allow attackers to bypass authentication.
Unknown vulnerability in the web server for the ESS/ Network Controller for Xerox Document Centre 240 through 555 running System Software 27.18.017 and earlier allows attackers to "gain unauthorized access."
Xerox Phaser 6510 before 64.61.23 and 64.59.11 (Bridge), WorkCentre 6515 before 65.61.23 and 65.59.11 (Bridge), VersaLink B400 before 37.61.23 and 37.59.01 (Bridge), B405 before 38.61.23 and 38.59.01 (Bridge), B600/B610 before 32.61.23 and 32.59.01 (Bridge), B605/B615 before 33.61.23 and 33.59.01 (Bridge), B7025/30/35 before 58.61.23 and 58.59.11 (Bridge), C400 before 67.61.23 and 67.59.01 (Bridge), C405 before 68.61.23 and 68.59.01 (Bridge), C500/C600 before 61.61.23 and 61.59.01 (Bridge), C505/C605 before 62.61.23 and 62.59.11 (Bridge), C7000 before 56.61.23 and 56.59.01 (Bridge), C7020/25/30 before 57.61.23 and 57.59.01 (Bridge), C8000/C9000 before 70.61.23 and 70.59.01 (Bridge), allows remote attackers with "a weaponized clone file" to execute arbitrary commands in the Web User Interface.
Xerox Phaser 6510 before 64.65.51 and 64.59.11 (Bridge), WorkCentre 6515 before 65.65.51 and 65.59.11 (Bridge), VersaLink B400 before 37.65.51 and 37.59.01 (Bridge), B405 before 38.65.51 and 38.59.01 (Bridge), B600/B610 before 32.65.51 and 32.59.01 (Bridge), B605/B615 before 33.65.51 and 33.59.01 (Bridge), B7025/30/35 before 58.65.51 and 58.59.11 (Bridge), C400 before 67.65.51 and 67.59.01 (Bridge), C405 before 68.65.51 and 68.59.01 (Bridge), C500/C600 before 61.65.51 and 61.59.01 (Bridge), C505/C605 before 62.65.51 and 62.59.01 (Bridge), C7000 before 56.65.51 and 56.59.01 (Bridge), C7020/25/30 before 57.65.51 and 57.59.01 (Bridge), C8000/C9000 before 70.65.51 and 70.59.01 (Bridge), C8000W before 72.65.51 allows remote attackers to execute arbitrary code through a buffer overflow in Web page parameter handling.
Xerox Phaser 6510 before 64.65.51 and 64.59.11 (Bridge), WorkCentre 6515 before 65.65.51 and 65.59.11 (Bridge), VersaLink B400 before 37.65.51 and 37.59.01 (Bridge), B405 before 38.65.51 and 38.59.01 (Bridge), B600/B610 before 32.65.51 and 32.59.01 (Bridge), B605/B615 before 33.65.51 and 33.59.01 (Bridge), B7025/30/35 before 58.65.51 and 58.59.11 (Bridge), C400 before 67.65.51 and 67.59.01 (Bridge), C405 before 68.65.51 and 68.59.01 (Bridge), C500/C600 before 61.65.51 and 61.59.01 (Bridge), C505/C605 before 62.65.51 and 62.59.01 (Bridge), C7000 before 56.65.51 and 56.59.01 (Bridge), C7020/25/30 before 57.65.51 and 57.59.01 (Bridge), C8000/C9000 before 70.65.51 and 70.59.01 (Bridge), C8000W before 72.65.51 have a remote Command Execution vulnerability in the Web User Interface that allows remote attackers with "a weaponized clone file" to execute arbitrary commands.
An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. An attacker can execute PHP code by leveraging a writable file.
Multiple SQL injection vulnerabilities in Xerox CentreWare Web (CWW) before 4.6.46 allow remote authenticated users to execute arbitrary SQL commands via the unspecified vectors.
SQL injection vulnerability in Xerox DocuShare before 6.53 Patch 6 Hotfix 2, 6.6.1 Update 1 before Hotfix 24, and 6.6.1 Update 2 before Hotfix 3 allows remote authenticated users to execute arbitrary SQL commands via the PATH_INFO to /docushare/dsweb/ResultBackgroundJobMultiple/. NOTE: some of these details are obtained from third party information.
SQL injection vulnerability in news_detail.php in Green Desktiny 2.3.1, and possibly earlier versions, allows remote attackers to execute arbitrary SQL commands via the id parameter.
SQL injection vulnerability in ogp_show.php in Online Guestbook Pro allows remote attackers to execute arbitrary SQL commands via the display parameter.
Multiple SQL injection vulnerabilities in Alwasel 1.5 allow remote attackers to execute arbitrary SQL commands via the id parameter to (1) show.php and (2) xml.php.
SQL injection vulnerability in boardrule.php in DVBBS 2.0 allows remote attackers to execute arbitrary SQL commands via the groupboardid parameter.
A vulnerability was identified in tushar-2223 Hotel Management System up to bb1f3b3666124b888f1e4bcf51b6fba9fbb01d15. Affected by this vulnerability is an unknown functionality of the file /admin/roomdelete.php. The manipulation of the argument ID leads to sql injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. This product follows a rolling release approach for continuous delivery, so version details for affected or updated releases are not provided. The project was informed of the problem early through an issue report but has not responded yet.
SQL injection vulnerability in the JExtensions JE Directory (com_jedirectory) component 1.0 for Joomla! allows remote attackers to execute arbitrary SQL commands via the catid parameter in an item action to index.php.
SQL injection vulnerability in index.php in RadNICS Gold 5 allows remote attackers to execute arbitrary SQL commands via the fid parameter in a view_forum action.
A vulnerability was identified in itsourcecode Courier Management System 1.0. The affected element is an unknown function of the file /edit_parcel.php. The manipulation of the argument ID leads to sql injection. The attack can be initiated remotely. The exploit is publicly available and might be used.
SQL injection vulnerability in the Tiny Market (hm_tinymarket) extension 0.5.4 and earlier for TYPO3 allows remote attackers to execute arbitrary SQL commands via unspecified vectors.
Online Accreditation Management v1.0 was discovered to contain a SQL injection vulnerability via the USERNAME parameter at process.php.
Hospital Management System v1.0 was discovered to contain a SQL injection vulnerability via the editid parameter at orders.php.
SQL injection vulnerability in the Versatile Calendar Extension [VCE] (sk_calendar) extension before 0.3.4 for TYPO3 allows remote attackers to execute arbitrary SQL commands via unspecified vectors.
Multiple SQL injection vulnerabilities in Tourism Script Bus Script allow remote attackers to execute arbitrary SQL commands via the sitetext_id parameter to (1) aboutus.php and (2) faq.php.
SQL injection vulnerability in the JExtensions JE Auto (com_jeauto) component before 1.1 for Joomla! allows remote attackers to execute arbitrary SQL commands via unspecified vectors related to the view item page.
SQL injection vulnerability in video.php in Get Tube 4.51 and earlier allows remote attackers to execute arbitrary SQL commands via the id parameter.
Rescue Dispatch Management System v1.0 is vulnerable to SQL Injection via /rdms/admin/incident_reports/manage_report.php?id=.
CMS ISWEB 3.5.3 is vulnerable to multiple SQL injection flaws. An attacker can inject malicious queries into the application and obtain sensitive information.
SQL injection vulnerability in ChronoScan version 1.5.4.3 and earlier allows an unauthenticated attacker to execute arbitrary SQL commands via the wcr_machineid cookie.
Hospital Management System v1.0 was discovered to contain a SQL injection vulnerability via the loginid parameter at adminlogin.php.
SQL injection vulnerability in the Addressbook module for Drupal 6.x-4.2 and earlier allows remote attackers to execute arbitrary SQL commands via unspecified vectors.
Badminton Center Management System v1.0 is vulnerable to SQL Injection via bcms/classes/Master.php?f=delete_product.
A vulnerability classified as critical was found in PHPGurukul e-Diary Management System 1.0. This vulnerability affects unknown code of the file /view-note.php?noteid=11. The manipulation of the argument remark leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Online Ordering System v2.3.2 was discovered to contain a SQL injection vulnerability via /ordering/admin/store/index.php?view=edit&id=.
Multiple SQL injection vulnerabilities in Graugon PHP Article Publisher 1.0 allow remote attackers to execute arbitrary SQL commands via the (1) c parameter to index.php and the (2) id parameter to view.php.