Grandstream GWN7000 firmware version 1.0.9.4 and below allows authenticated remote users to modify the system's crontab via undocumented API. An attacker can use this functionality to execute arbitrary OS commands on the router.
Grandstream GXV3370 before 1.0.1.41 and WP820 before 1.0.3.6 devices allow remote authenticated users to execute arbitrary code via shell metacharacters in a /manager?action=getlogcat priority field.
Grandstream UCM6204 before 1.0.19.20 devices allow remote authenticated users to execute arbitrary code via shell metacharacters in the backupUCMConfig file-backup parameter to the /cgi? URI.
Grandstream GWN7000 before 1.0.6.32 devices allow remote authenticated users to execute arbitrary code via shell metacharacters in the filename in a /ubus/uci.apply update_nds_webroot_from_tmp API call.
Grandstream UCM6200 series firmware version 1.0.20.23 and below is vulnerable to OS command injection via HTTP. An authenticated remote attacker can execute commands as the root user by sending a crafted HTTP GET to the UCM's "Old" HTTPS API.
Grandstream GWN7610 before 1.0.8.18 devices allow remote authenticated users to execute arbitrary code via shell metacharacters in the filename in a /ubus/controller.icc.update_nds_webroot_from_tmp update_nds_webroot_from_tmp API call.
The Grandstream UCM Series IP PBX before firmware version 1.0.20.52 is affected by a parameter injection vulnerability in the HTTP interface. A remote and authenticated attacker can execute arbitrary code by sending a crafted HTTP request. Authentication may be possible using a default user and password. Affected models are the UCM6202, UCM6204, UCM6208, and UCM6510.
Grandstream GXP1600 series firmware 1.0.4.152 and below is vulnerable to authenticated remote command execution when an attacker adds an OpenVPN up script to the phone's VPN settings via the "Additional Settings" field in the web interface. When the VPN's connection is established, the user defined script is executed with root privileges.
An issue was discovered on the Grandstream HT801 Analog Telephone Adaptor before 1.0.29.8. From the limited configuration shell, it is possible to set the malicious gdb_debug_server variable. As a result, after a reboot, the device downloads and executes malicious scripts from an attacker-defined host.
Multiple buffer overflows in the limited configuration shell (/sbin/gs_config) on Grandstream HT801 devices before 1.0.29 allow remote authenticated users to execute arbitrary code as root via a crafted manage_if setting, thus bypassing the intended restrictions of this shell and taking full control of the device. There are default weak credentials that can be used to authenticate.
Grandstream GXP1600 series firmware 1.0.4.152 and below is vulnerable to authenticated remote command execution when an attacker uploads a specially crafted tar file to the HTTP /cgi-bin/upload_vpntar interface.
Grandstream UCM6204 before 1.0.19.20 devices allow remote authenticated users to conduct SQL injection attacks via the sord parameter in a listCodeblueGroup API call to the /cgi? URI.
Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt.
Shell Metacharacter Injection in the SSH configuration interface on Grandstream GXP16xx VoIP 1.0.4.128 phones allows attackers to execute arbitrary system commands and gain a root shell.
Grandstream UCM6200 series firmware version 1.0.20.23 and below is vulnerable to OS command injection via SSH. An authenticated remote attacker can execute commands as the root user by issuing a specially crafted "unset" command.
Grandstream UCM6200 series firmware version 1.0.20.23 and below is vulnerable to OS command injection via HTTP. An authenticated remote attacker can bypass command injection mitigations and execute commands as the root user by sending a crafted HTTP POST to the UCM's "New" HTTPS API.
An os command injection vulnerability exists in the CWMP SelfDefinedTimeZone functionality of Grandstream GXP2135 1.0.9.129, 1.0.11.74 and 1.0.11.79. A specially crafted network packet can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability.
Grandstream GAC2500 1.0.3.35, GXP2200 1.0.3.27, GVC3202 1.0.3.51, GXV3275 before 1.0.3.219 Beta, and GXV3240 before 1.0.3.219 Beta devices allow unauthenticated remote code execution via shell metacharacters in a /manager?action=getlogcat priority field, in conjunction with a buffer overflow (via the phonecookie cookie) to overwrite a data structure and consequently bypass authentication. This can be exploited remotely or via CSRF because the cookie can be placed in an Accept HTTP header in an XMLHttpRequest call to lighttpd.
Grandstream GWN7000 before 1.0.6.32 and GWN7610 before 1.0.8.18 devices allow remote authenticated users to discover passwords via a /ubus/uci.apply config request.
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message.
IBM FileNet Content Manager 5.5.4, 5.5.6, and 5.5.7 could allow a remote authenticated attacker to execute arbitrary commands on the system by sending a specially crafted request. IBM X-Force ID: 212346.
A vulnerability has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this issue is the function setDFSSetting of the file /goform/setLan. The manipulation of the argument lanNetmask/lanIp leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function um_inspect_cross_band of the file /goform/RP_setBasicAuto. The manipulation of the argument staticGateway leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
User provided input is not sanitized on the AXIS License Plate Verifier specific “api.cgi” allowing for arbitrary code execution.
An OS command injection vulnerability in FortiWeb's management interface 6.3.7 and below, 6.2.3 and below, 6.1.x, 6.0.x, 5.9.x may allow a remote authenticated attacker to execute arbitrary commands on the system via the SAML server configuration page.
User provided input is not sanitized in the “Settings > Access Control” configuration interface allowing for arbitrary code execution.
The administrative web interface in Cisco TelePresence Video Communication Server Expressway X8.5.2 allows remote authenticated users to execute arbitrary commands via crafted fields, aka Bug ID CSCuv12531.
In the web ui of the openbuildservice before 2.3.0 a code injection of the project rebuildtimes statistics could be used by authorized attackers to execute shellcode.
MiR software versions prior to version 3.0.0 are affected by a command injection vulnerability. A malicious HTTP request crafted by an authenticated user could allow the execution of arbitrary commands on the underlying operating system.
A vulnerability was found in DCN DCME-720 9.1.5.11. This affects an unknown function of the file /usr/local/www/function/audit/newstatistics/ip_block.php of the component Web Management Backend. Performing manipulation of the argument ip results in os command injection. It is possible to initiate the attack remotely. The exploit has been made public and could be used. Other products might be affected as well. The vendor was contacted early about this disclosure but did not respond in any way.
In some Lenovo ThinkServer-branded servers, a command injection vulnerability exists in the BMC firmware download command. This allows a privileged user to download and execute arbitrary code inside the BMC. This can only be exploited by authorized privileged users.
Unitronics Unistream Unilogic – Versions prior to 1.35.227 - CWE-78: 'OS Command Injection' may allow RCE
Multiple vulnerabilities in the web management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system. The attacker would need valid device credentials but does not require administrator privileges to exploit this vulnerability. These vulnerabilities are due to insufficient validation of user-supplied input for certain configuration options. An attacker could exploit these vulnerabilities by using crafted input within the device configuration GUI. A successful exploit could allow the attacker to execute arbitrary commands on the device including the underlying operating system which could also affect the availability of the device.
An OS Command Injection vulnerability exists in SIMULIA 3DOrchestrate from Release 3DEXPERIENCE R2021x through Release 3DEXPERIENCE R2023x. A specially crafted HTTP request can lead to arbitrary command execution.
A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this vulnerability is the function setDeviceName of the file /goform/setDeviceName. The manipulation of the argument DeviceName leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability in the Cisco IOx application hosting environment could allow an authenticated, remote attacker to execute arbitrary commands as root on the underlying host operating system. This vulnerability is due to incomplete sanitization of parameters that are passed in for activation of an application. An attacker could exploit this vulnerability by deploying and activating an application in the Cisco IOx application hosting environment with a crafted activation payload file. A successful exploit could allow the attacker to execute arbitrary commands as root on the underlying host operating system.
Improper Input Validation vulnerability in N-able N-central allows OS Command Injection.This issue affects N-central: before 2025.3.1.
A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this vulnerability is the function um_red of the file /goform/RP_setBasicAuto. The manipulation of the argument hname leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257667. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
InHand Networks IR615 Router's Versions 2.3.0.r4724 and 2.3.0.r4870 are vulnerable to an attacker using a ping tool to inject commands into the device. This may allow the attacker to remotely run commands on behalf of the device.
InHand Networks IR615 Router's Versions 2.3.0.r4724 and 2.3.0.r4870 are vulnerable to an attacker using a traceroute tool to inject commands into the device. This may allow the attacker to remotely run commands on behalf of the device.
A vulnerability, which was classified as critical, has been found in agno-agi agno up to 1.7.5. This issue affects the function MCPTools/MultiMCPTools in the library libs/agno/agno/tools/mcp.py of the component Model Context Protocol Handler. The manipulation of the argument command leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected is the function ipv6cmd of the file /goform/setIpv6. The manipulation of the argument Ipv6PriDns/Ipv6SecDns/Ipv6StaticGateway/LanIpv6Addr/LanPrefixLen/pppoeUser/pppoePass/pppoeIdleTime/pppoeRedialPeriod/Ipv6in4_PrefixLen/LocalIpv6/RemoteIpv4/LanIPv6_Prefix/LanPrefixLen/ipv6to4Relay/ipv6rdRelay/tunrd_PrefixLen/wan_UseLinkLocal/Ipv6StaticIp/Ipv6PrefixLen leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A security vulnerability has been detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function addStaticRoute of the file /goform/addStaticRoute. Such manipulation of the argument staticRoute_IP_setting/staticRoute_Netmask_setting/staticRoute_Gateway_setting/staticRoute_Metric_setting/staticRoute_destType_setting leads to os command injection. The attack may be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
programs/pluto/xauth.c in the client in Openswan 2.6.25 through 2.6.28 allows remote authenticated gateways to execute arbitrary commands via shell metacharacters in (1) cisco_dns_info or (2) cisco_domain_info data in a packet, a different vulnerability than CVE-2010-3302.
NETGEAR Prosafe WC9500 5.1.0.17, WC7600 5.1.0.17, and WC7520 2.5.0.35 devices allow a remote attacker to execute code with root privileges via shell metacharacters in the reqMethod parameter to login_handler.php.
A vulnerability was found in agentUniverse up to 0.0.18 and classified as critical. This issue affects the function StdioServerParameters of the component MCPSessionManager/MCPTool/MCPToolkit. The manipulation leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this issue is the function sub_3517C of the file /goform/setWan. The manipulation of the argument Hostname leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Silex SD-320AN version 2.01 and prior and GE MobileLink(GEH-SD-320AN) version GEH-1.1 and prior have a system call parameter that is not properly sanitized, which may allow remote code execution.
A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This affects the function RP_setBasicAuto of the file /goform/RP_setBasicAuto. The manipulation of the argument staticIp/staticNetmask leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.