Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18593.
Multiple vulnerabilities in Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an attacker to escape from the guest virtual machine (VM) to the host machine, inject commands that execute at the root level, or leak system data from the host to the VM. For more information about these vulnerabilities, see the Details section of this advisory.
Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18644.
Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18591.
An XML External Entity Injection (XXE) vulnerability in the Management System (console) of BlackBerry AtHoc versions earlier than 7.6 HF-567 could allow an attacker to potentially read arbitrary local files from the application server or make requests on the network by entering maliciously crafted XML in an existing field.
When opening a malicious solution file provided by an attacker, the application suffers from an XML external entity vulnerability due to an unsafe call within a dynamic link library file. An attacker could exploit this to pass data from local files to a remote web server, leading to a loss of confidentiality.
In four instances DMARS (All versions prior to v2.1.10.24) does not properly restrict references of XML external entities while processing specific project files, which may allow unauthorized information disclosure.
Improper Restriction of XML External Entity Reference in GitHub repository skylot/jadx prior to 1.3.2.
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could result in information disclosure when opening a malicious solution file provided by an attacker with SCADAPack Workbench. This could be exploited to pass data from local files to a remote system controlled by an attacker. Affected Product: SCADAPack Workbench (6.6.8a and prior)
An information disclosure vulnerability exists in Microsoft SQL Server Management Studio (SSMS) when parsing malicious XML content containing a reference to an external entity, aka "SQL Server Management Studio Information Disclosure Vulnerability." This affects SQL Server Management Studio 17.9, SQL Server Management Studio 18.0. This CVE ID is unique from CVE-2018-8527, CVE-2018-8532.
An information disclosure vulnerability exists in Microsoft SQL Server Management Studio (SSMS) when parsing a malicious XMLA file containing a reference to an external entity, aka "SQL Server Management Studio Information Disclosure Vulnerability." This affects SQL Server Management Studio 17.9, SQL Server Management Studio 18.0. This CVE ID is unique from CVE-2018-8527, CVE-2018-8533.
An information disclosure vulnerability exists in Microsoft SQL Server Management Studio (SSMS) when parsing a malicious XEL file containing a reference to an external entity, aka "SQL Server Management Studio Information Disclosure Vulnerability." This affects SQL Server Management Studio 17.9, SQL Server Management Studio 18.0. This CVE ID is unique from CVE-2018-8532, CVE-2018-8533.