In ONAP DCAE through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
In ONAP CLI through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
In ONAP OOM through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
In ONAP SO through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
In ONAP Logging through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
In ONAP MSB through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in ONAP SDC through Dublin. By accessing port 6000 of demo-sdc-sdc-fe pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in ONAP SDC through Dublin. By accessing port 7000 of demo-sdc-sdc-wfd-fe pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in ONAP SDC through Dublin. By accessing port 4000 of demo-sdc-sdc-be pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in ONAP SDC through Dublin. By accessing port 7001 of demo-sdc-sdc-wfd-be pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in ONAP SDC through Dublin. By accessing port 4001 of demo-sdc-sdc-onboarding-be pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in ONAP HOLMES before Dublin. By accessing port 9202 of dep-holmes-engine-mgmt pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in ONAP SDNC before Dublin. By executing sla/dgUpload with a crafted filename parameter, an unauthenticated attacker can execute an arbitrary command. All SDC setups that include admportal are affected.
An issue was discovered in ONAP SDNC before Dublin. By executing sla/upload with a crafted filename parameter, an unauthenticated attacker can execute an arbitrary command. All SDC setups that include admportal are affected.
Trendnet AC2600 TEW-827DRU version 2.08B01 contains an authentication bypass vulnerability. It is possible for an unauthenticated, malicous actor to force the change of the admin password due to a hidden administrative command.
A vulnerability in the REST API of Cisco IoT Field Network Director (FND) could allow an unauthenticated, remote attacker to access the back-end database of an affected system. The vulnerability exists because the affected software does not properly authenticate REST API calls. An attacker could exploit this vulnerability by obtaining a cross-site request forgery (CSRF) token and then using the token with REST API requests. A successful exploit could allow the attacker to access the back-end database of the affected device and read, alter, or drop information.
Multiple vulnerabilities in Cisco Application Services Engine could allow an unauthenticated, remote attacker to gain privileged access to host-level operations or to learn device-specific information, create diagnostic files, and make limited configuration changes. For more information about these vulnerabilities, see the Details section of this advisory.
The affected product’s configuration is vulnerable due to missing authentication, which may allow an attacker to change configurations and execute arbitrary code on the iView (versions prior to v5.7.03.6182).
CouchDB version 3.0.0 shipped with a new configuration setting that governs access control to the entire database server called `require_valid_user_except_for_up`. It was meant as an extension to the long standing setting `require_valid_user`, which in turn requires that any and all requests to CouchDB will have to be made with valid credentials, effectively forbidding any anonymous requests. The new `require_valid_user_except_for_up` is an off-by-default setting that was meant to allow requiring valid credentials for all endpoints except for the `/_up` endpoint. However, the implementation of this made an error that lead to not enforcing credentials on any endpoint, when enabled. CouchDB versions 3.0.1[1] and 3.1.0[2] fix this issue.
Missing Authentication for Critical Function vulnerability in Centreon Infra Monitoring centreon-awie (Awie import module) allows Accessing Functionality Not Properly Constrained by ACLs. This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.3, from 24.04.0 before 24.04.3.
WHILL Model C2 Electric Wheelchairs and Model F Power Chairs do not enforce authentication for Bluetooth connections. An attacker within range can pair with the device and issue movement commands, override speed restrictions, and manipulate configuration profiles without any credentials or user interaction.
Missing authentication and improper input validation in KERUI Wifi Endoscope Camera (YPC99) allow an attacker to execute arbitrary commands (with a length limit of 19 characters) via the "ssid" value, as demonstrated by ssid:;ping 192.168.1.2 in the body of a SETSSID command.
The Dingtian DT-R0 Series is vulnerable to an exploit that allows attackers to bypass login requirements by directly navigating to the main page.
An issue was discovered on D-Link DSL-2640B B2 EU_4.01B devices. A cfm UDP service listening on port 65002 allows remote, unauthenticated exfiltration of administrative credentials.
Missing Authentication for Critical Function vulnerability in Sharp Display Solutions Media Player MP-01 All Verisons allows a attacker may access to the web interface of the affected product without authentication and change settings or perform other operations, and deliver content from the authoring software to the affected product without authentication.
A security flaw has been discovered in ChurchCRM up to 5.18.0. This impacts the function AuthMiddleware of the file src/ChurchCRM/Slim/Middleware/AuthMiddleware.php of the component API Endpoint. The manipulation results in missing authentication. The attack can be executed remotely. The exploit has been released to the public and may be exploited. The patch is identified as 3a1cffd2aea63d884025949cfbcfd274d06216a4. A patch should be applied to remediate this issue.
A flaw has been found in 70mai X200 up to 20251010. Affected is an unknown function of the component Pairing. Executing manipulation can lead to missing authentication. It is possible to launch the attack remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T300 (with firmware 2.7 and older) that could cause a wide range of problems, including information exposure, denial of service, and command execution when access to a resource from an attacker is not restricted or incorrectly restricted.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Unauthenticated API Endpoints.
Server Version Disclosure.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 .
A vulnerability was found in ProjectsAndPrograms School Management System up to 6b6fae5426044f89c08d0dd101c7fa71f9042a59. This affects an unknown part. Performing manipulation results in missing authentication. The attack is possible to be carried out remotely. The exploit has been made public and could be used. This product adopts a rolling release strategy to maintain continuous delivery
Resource Lacking AuthN.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 .
Trend Micro Apex One (2019), OfficeScan XG and Worry-Free Business Security (9.0, 9.5, 10.0) server contains a vulnerable service DLL file that could allow a remote attacker to execute arbitrary code on affected installations with SYSTEM level privileges. Authentication is not required to exploit this vulnerability.
AVEVA System Platform versions 2017 through 2020 R2 P01 does not perform any authentication for functionality that requires a provable user identity.
An issue was discovered in OpServices OpMon 9.3.2 that allows Remote Code Execution .
The CE21 Suite plugin for WordPress is vulnerable to unauthorized plugin settings update due to a missing capability check on the wp_ajax_nopriv_ce21_single_sign_on_save_api_settings AJAX action in versions 2.2.1 to 2.3.1. This makes it possible for unauthenticated attackers to update the plugin's API settings including a secret key used for authentication. This allows unauthenticated attackers to create new admin accounts on an affected site.
A remote unauthenticated arbitrary code execution vulnerability was discovered in Aruba Airwave Software version(s): Prior to 1.3.2.
A ZTE product is impacted by the improper access control vulnerability. Due to lack of an authentication protection mechanism in the program, attackers could use this vulnerability to gain access right through brute-force attacks. This affects: <ZXONE 19700 SNPE><ZXONE8700V1.40R2B13_SNPE>
Standalone clients connecting to SAP NetWeaver AS Java via P4 Protocol, versions (SAP-JEECOR 7.00, 7.01; SERVERCOR 7.10, 7.11, 7.20, 7.30, 7.31, 7.40, 7.50; CORE-TOOLS 7.00, 7.01, 7.02, 7.05, 7.10, 7.11, 7.20, 7.30, 7.31, 7.40, 7.50) do not perform any authentication checks for operations that require user identity leading to Authentication Bypass.
Statistical Database System developed by Gotac has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to read, modify, and delete database contents with high-level privileges.
The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions).
The JMX/RMI interface in Nasdaq BWise 5.0 does not require authentication for an SAP BO Component, which allows remote attackers to execute arbitrary code via a session on port 81.
The airPASS from NetVision Information has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access the specific administrative functionality to retrieve * all accounts and passwords.
Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior do not perform authentication of IEC-104 control commands, which may allow a rogue node a remote control of the industrial process.
An authentication bypass vulnerability on Genexis Platinum-4410 v2.1 P4410-V2 1.28 devices allows attackers to obtain cleartext credentials from the HTML source code of the cgi-bin/index2.asp URI.
Orthanc server prior to version 1.5.8 does not enable basic authentication by default when remote access is enabled. This could result in unauthorized access by an attacker.
SAP Business Objects Business Intelligence Platform (Live Data Connect), versions 1.0, 2.0, 2.1, 2.2, 2.3, allows an attacker to logon on the Central Management Console without password in case of the BIPRWS application server was not protected with some specific certificate, leading to Missing Authentication Check.
The ClearPass Policy Manager web interface is affected by a vulnerability that leads to authentication bypass. Upon successful bypass an attacker could then execute an exploit that would allow to remote command execution in the underlying operating system. Resolution: Fixed in 6.7.13-HF, 6.8.5-HF, 6.8.6, 6.9.1 and higher.
The WordPress & WooCommerce Affiliate Program plugin for WordPress is vulnerable to authentication bypass in all versions up to, and including, 8.4.1. This is due to the rtwwwap_login_request_callback() function not properly validating a user's identity prior to authenticating them to the site. This makes it possible for unauthenticated attackers to log in as any user, including administrators, granted they have access to the administrator's email.
SAP Solution Manager (User Experience Monitoring), version- 7.2, due to Missing Authentication Check does not perform any authentication for a service resulting in complete compromise of all SMDAgents connected to the Solution Manager.