Softing Secure Integration Server Exposure of Resource to Wrong Sphere Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Softing Secure Integration Server. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the handling of OPC FileDirectory namespaces. The issue results from the lack of proper validation of user-supplied data before using it to create a server object. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of root. Was ZDI-CAN-20547.
Softing Secure Integration Server Interpretation Conflict Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Softing Secure Integration Server. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the web server. The issue results from an inconsistency in URI parsing between NGINX and application code. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of root. Was ZDI-CAN-20551.
An issue was discovered in Softing uaGate SI 1.60.01. A CGI script is vulnerable to command injection with a maliciously crafted url parameter.
Softing Secure Integration Server OPC UA Gateway Directory Creation Vulnerability. This vulnerability allows remote attackers to create directories on affected installations of Softing Secure Integration Server. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the handling of FileDirectory OPC UA Objects. The issue results from allowing unauthorized access to the filesystem. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of root. Was ZDI-CAN-20548.
Softing edgeAggregator Permissive Cross-domain Policy with Untrusted Domains Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Softing edgeAggregator. Authentication is required to exploit this vulnerability. The specific flaw exists within the configuration of the web server. The issue results from the lack of appropriate Content Security Policy headers. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20542.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects GC108P before 1.0.8.2, GC108PP before 1.0.8.2, GS108Tv3 before 7.0.7.2, GS110TPv3 before 7.0.7.2, GS110TPP before 7.0.7.2, GS110TUP before 1.0.5.3, GS710TUP before 1.0.5.3, GS308T before 1.0.3.2, GS310TP before 1.0.3.2, GS710TUP before 1.0.5.3, GS716TP before 1.0.4.2, GS716TPP before 1.0.4.2, GS724TPP before 2.0.6.3, GS724TPv2 before 2.0.6.3, GS724TPP before 2.0.6.3, GS728TPPv2 before 6.0.8.2, GS728TPv2 before 6.0.8.2, GS752TPv2 before 6.0.8.2, GS752TPP before 6.0.8.2, GS750E before 1.0.1.10, MS510TXM before 1.0.4.2, and MS510TXUP before 1.0.4.2.
An issue was discovered on Vera VeraEdge 1.7.19 and Veralite 1.7.481 devices. The device provides a web user interface that allows a user to manage the device. As a part of the functionality the device firmware file contains a file known as relay.sh which allows the device to create relay ports and connect the device to Vera servers. This is primarily used as a method of communication between the device and Vera servers so the devices can be communicated with even when the user is not at home. One of the parameters retrieved by this specific script is "remote_host". This parameter is not sanitized by the script correctly and is passed in a call to "eval" to execute another script where remote_host is concatenated to be passed a parameter to the second script. This allows an attacker to escape from the executed command and then execute any commands of his/her choice.
RELY-PCIe v22.2.1 to v23.1.0 was discovered to contain a code injection vulnerability via the getParams function in phpinf.php.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
The KuWFi 4G AC900 LTE router 1.0.13 is vulnerable to command injection on the HTTP API endpoints /goform/formMultiApnSetting and /goform/atCmd. An authenticated attacker can execute arbitrary OS commands with root privileges via shell metacharacters in parameters such as pincode and cmds. Exploitation can lead to full system compromise, including enabling remote access (e.g., enabling telnet).
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, and RBS850 before 3.2.17.12.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7000 before 1.0.11.126, R6900P before 1.3.2.126, and R7000P before 1.3.2.126.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6200 before 1.1.00.40, D7000 before 1.0.1.78, R6020 before 1.0.0.42, R6080 before 1.0.0.42, R6050 before 1.0.1.26, JR6150 before 1.0.1.26, R6120 before 1.0.0.66, R6220 before 1.1.0.110, R6230 before 1.1.0.110, R6260 before 1.1.0.64, R6800 before 1.2.0.62, R6700v2 before 1.2.0.62, R6900v2 before 1.2.0.62, R7450 before 1.2.0.62, AC2100 before 1.2.0.62, AC2400 before 1.2.0.62, AC2600 before 1.2.0.62, and WNR2020 before 1.1.0.62.
An issue was discovered on Securifi Almond, Almond+, and Almond 2015 devices with firmware AL-R096. The device provides a user with the capability of adding new routes to the device. It seems that the POST parameters passed in this request to set up routes on the device can be set in such a way that would result in passing commands to a "popen" API in the function and thus result in command injection on the device. If the firmware version AL-R096 is dissected using binwalk tool, we obtain a cpio-root archive which contains the filesystem set up on the device that contains all the binaries. The binary "goahead" is the one that has the vulnerable function that receives the values sent by the POST request. If we open this binary in IDA-pro we will notice that this follows a MIPS little endian format. The function sub_00420F38 in IDA pro is identified to be receiving the values sent in the POST request and the value set in POST parameter "dest" is extracted at address 0x00420FC4. The POST parameter "dest is concatenated in a route add command and this is passed to a "popen" function at address 0x00421220. This allows an attacker to provide the payload of his/her choice and finally take control of the device.
NETGEAR D6220 devices before 1.0.0.76 are affected by command injection by an authenticated user.
FusionSphere V100R006C00SPC102(NFV) has a command injection vulnerability. An authenticated, remote attacker could craft packets with malicious strings and send them to a target device. Successful exploit could allow the attacker to launch a command injection attack and execute system commands.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects LBR20 before 2.6.3.50, RBS50Y before 2.7.3.22, RBR10 before 2.7.3.22, RBR20 before 2.7.3.22, RBR40 before 2.7.3.22, RBR50 before 2.7.3.22, RBS10 before 2.7.3.22, RBS20 before 2.7.3.22, RBS40 before 2.7.3.22, RBS50 before 2.7.3.22, RBK12 before 2.7.3.22, RBK20 before 2.7.3.22, RBK40 before 2.7.3.22, and RBK50 before 2.7.3.22.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7900 before 1.0.4.38, R7900P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6.
In Draytek Vigor3900 1.5.1.3, attackers can inject malicious commands into mainfunction.cgi and execute arbitrary commands by calling the pingtrace function.
In Draytek Vigor3900 1.5.1.3, attackers can inject malicious commands into mainfunction.cgi and execute arbitrary commands by calling the packet_monitor function.
The Symantec Messaging Gateway before 10.6.3-267 can encounter an issue of remote code execution, which describes a situation whereby an individual may obtain the ability to execute commands remotely on a target machine or in a target process. In this type of occurrence, after gaining access to the system, the attacker may attempt to elevate their privileges.
A vulnerability in the HPE Aruba Networking ClearPass Policy Manager web-based management interface could allow an authenticated remote threat actor to conduct a remote code execution attack. Successful exploitation could enable the attacker to run arbitrary commands on the underlying operating system.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.60, DM200 before 1.0.0.66, EX2700 before 1.0.1.56, EX6150v2 before 1.0.1.86, EX6200v2 before 1.0.1.86, EX6250 before 1.0.0.128, EX6400 before 1.0.2.144, EX6400v2 before 1.0.0.128, EX6410 before 1.0.0.128, EX6420 before 1.0.0.128, EX7300 before 1.0.2.144, EX7300v2 before 1.0.0.128, EX7320 before 1.0.0.128, R7500v2 before 1.0.3.46, R7800 before 1.0.2.74, R8900 before 1.0.5.26, R9000 before 1.0.5.2, RAX120 before 1.0.1.128, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.80, WNR2000v5 before 1.0.0.74, XR500 before 2.3.2.66, RBK20 before 2.7.3.22, RBR20 before 2.7.3.22, RBS20 before 2.7.3.22, RBK40 before 2.7.3.22, RBR40 before 2.7.3.22, and RBS40 before 2.7.3.22.
DrayTek Vigor3900 1.5.1.3 allows attackers to inject malicious commands into mainfunction.cgi and execute arbitrary commands by calling the doCertificate function.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
A command-injection vulnerability exists in a web application on a custom-built GoAhead web server used on Foscam, Vstarcam, and multiple white-label IP camera models. The mail-sending form in the mail.htm page allows an attacker to inject a command into the receiver1 field in the form; it will be executed with root privileges.
VINGA WR-N300U 77.102.1.4853 is affected by a command execution vulnerability in the goahead component.
Edimax AC1200 Wi-Fi 5 Dual-Band Router BR-6476AC 1.06 suffers from Command Injection issues in /bin/goahead. Specifically, these issues can be triggered through /goform/tracerouteDiagnosis, /goform/pingDiagnosis, and /goform/fromSysToolPingCmd Each of these issues allows an attacker with access to the web interface to inject and execute arbitrary shell commands, with "root" privileges.
In Citrix XenMobile Server through 10.12 RP9, there is an Authenticated Command Injection vulnerability, leading to remote code execution with root privileges.
An exploitable command injection vulnerability exists in the web management interface used by the Foscam C1 Indoor HD Camera running application firmware 2.52.2.37. A specially crafted HTTP request can allow for a user to inject arbitrary shell characters during a password change resulting in command injection. An attacker can simply send an HTTP request to the device to trigger this vulnerability.
A Remote Code Execution (RCE) vulnerability exists in Ruijie Networks Ruijie RG-EW Series Routers up to ReyeeOS 1.55.1915 / EW_3.0(1)B11P55 via the doSwitchApi function in /cgi-bin/luci/api/switch.
The affected product is vulnerable to a parameter injection via passphrase, which enables the attacker to supply uncontrolled input.
GaussDB 200 with version of 6.5.1 have a command injection vulnerability. Due to insufficient input validation, remote attackers with low permissions could exploit this vulnerability by sending crafted commands to the affected device. Successful exploit could allow an attacker to execute commands.
OPNsense 25.1 contains an authenticated command injection vulnerability in its Bridge Interface Edit endpoint (interfaces_bridge_edit.php). The span POST parameter is concatenated into a system-level command without proper sanitization or escaping, allowing an administrator to inject arbitrary shell operators and payloads. Successful exploitation grants RCE with the privileges of the web service (typically root), potentially leading to full system compromise or lateral movement. This vulnerability arises from inadequate input validation and improper handling of user-supplied data in backend command invocations.
Command Injection in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to execute commands as root.
A Remote Code Execution (RCE) vulnerability exists in Ruijie Networks Ruijie RG-EW Series Routers up to ReyeeOS 1.55.1915 / EW_3.0(1)B11P55 via the switchFastDhcp function in /cgi-bin/luci/api/diagnose.
A Remote Code Execution (RCE) vulnerability exists in Ruijie Networks Ruijie RG-EW Series Routers up to ReyeeOS 1.55.1915 / EW_3.0(1)B11P55 via the setSessionTime function in /cgi-bin/luci/api/common..
A Remote Code Execution (RCE) vulnerability exists in Ruijie Networks Ruijie RG-EW Series Routers up to ReyeeOS 1.55.1915 / EW_3.0(1)B11P55 via the runPackDiagnose function in /cgi-bin/luci/api/diagnose.
A command injection vulnerability in the IDP feature of Juniper Networks Junos OS on SRX series devices potentially allows a user with login access to the device to execute shell commands and elevate privileges. Affected releases are Juniper Networks Junos OS 12.1X44 prior to 12.1X44-D60; 12.1X46 prior to 12.1X46-D50; 12.1X47 prior to 12.1X47-D30, 12.1X47-D35; 12.3X48 prior to 12.3X48-D20, 12.3X48-D30; 15.1X49 prior to 15.1X49-D20, 15.1X49-D30.
An issue was discovered in CALDERA 2.8.1. It contains multiple startup "requirements" that execute commands when starting the server. Because these commands can be changed via the REST API, an authenticated user can insert arbitrary commands that will execute when the server is restarted.
A improper neutralization of special elements used in a command ('command injection') in Fortinet FortiManager versions 7.4.1 through 7.4.3, FortiManager Cloud versions 7.4.1 through 7.4.3 allows attacker to escalation of privilege via specifically crafted packets
In Ericsson Network Location before 2021-07-31, it is possible for an authenticated attacker to inject commands via file_name in the export functionality. For example, a new admin user could be created.
A command injection vulnerability exists in Ivanti Avalanche before 6.3.3 allows an attacker with access to the Inforail Service to perform arbitrary command execution.
An authenticated remote code execution vulnerability was discovered in the AOS-CX Network Analytics Engine (NAE) in Aruba CX 6200F Switch Series, Aruba 6300 Switch Series, Aruba 6400 Switch Series, Aruba 8320 Switch Series, Aruba 8325 Switch Series, Aruba 8400 Switch Series, Aruba CX 8360 Switch Series version(s): AOS-CX 10.07.xxxx: 10.07.0050 and below, AOS-CX 10.08.xxxx: 10.08.1030 and below, AOS-CX 10.09.xxxx: 10.09.0002 and below. Aruba has released upgrades for Aruba AOS-CX devices that address this security vulnerability.
setup.cgi on NETGEAR R6020 1.0.0.48 devices allows an admin to execute arbitrary shell commands via shell metacharacters in the ntp_server field.
Multiple authenticated remote code execution vulnerabilities were discovered in the AOS-CX command line interface in Aruba CX 6200F Switch Series, Aruba 6300 Switch Series, Aruba 6400 Switch Series, Aruba 8320 Switch Series, Aruba 8325 Switch Series, Aruba 8400 Switch Series, Aruba CX 8360 Switch Series version(s): AOS-CX 10.06.xxxx: 10.06.0170 and below, AOS-CX 10.07.xxxx: 10.07.0050 and below, AOS-CX 10.08.xxxx: 10.08.1030 and below. Aruba has released upgrades for Aruba AOS-CX devices that address these security vulnerabilities.
In Ubiquiti Networks EdgeSwitch X v1.1.0 and prior, a privileged user can execute arbitrary shell commands over the SSH CLI interface. This allows to execute shell commands under the root user.
RELY-PCIe v22.2.1 to v23.1.0 was discovered to contain a command injection vulnerability via the time_date function.
A remote code execution vulnerability was identified in GitHub Enterprise Server that could be exploited when building a GitHub Pages site. To exploit this vulnerability, an attacker would need permission to create and build a GitHub Pages site on the GitHub Enterprise Server instance. This vulnerability affected all versions of GitHub Enterprise Server prior to 3.3 and was fixed in versions 3.0.21, 3.1.13, 3.2.5. This vulnerability was reported via the GitHub Bug Bounty program.