Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2019-16213

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-25 Jun, 2020 | 19:19
Updated At-05 Aug, 2024 | 01:10
Rejected At-
Credits

Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 could allow a remote authenticated attacker to execute arbitrary commands on the system. By sending a specially crafted string, an attacker could modify the device name of an attached PLC adapter to inject and execute arbitrary commands on the system with root privileges.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:25 Jun, 2020 | 19:19
Updated At:05 Aug, 2024 | 01:10
Rejected At:
▼CVE Numbering Authority (CNA)

Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 could allow a remote authenticated attacker to execute arbitrary commands on the system. By sending a specially crafted string, an attacker could modify the device name of an attached PLC adapter to inject and execute arbitrary commands on the system with root privileges.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://securityintelligence.com/posts/vulnerable-powerline-extenders-underline-lax-iot-security/
x_refsource_MISC
Hyperlink: https://securityintelligence.com/posts/vulnerable-powerline-extenders-underline-lax-iot-security/
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://securityintelligence.com/posts/vulnerable-powerline-extenders-underline-lax-iot-security/
x_refsource_MISC
x_transferred
Hyperlink: https://securityintelligence.com/posts/vulnerable-powerline-extenders-underline-lax-iot-security/
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:25 Jun, 2020 | 20:15
Updated At:01 Jul, 2020 | 20:59

Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 could allow a remote authenticated attacker to execute arbitrary commands on the system. By sending a specially crafted string, an attacker could modify the device name of an attached PLC adapter to inject and execute arbitrary commands on the system with root privileges.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary2.09.0HIGH
AV:N/AC:L/Au:S/C:C/I:C/A:C
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 9.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
CPE Matches

Tenda Technology Co., Ltd.
tendacn
>>pa6_firmware>>1.0.1.21
cpe:2.3:o:tendacn:pa6_firmware:1.0.1.21:*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tendacn
>>pa6>>-
cpe:2.3:h:tendacn:pa6:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-78Primarynvd@nist.gov
CWE ID: CWE-78
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://securityintelligence.com/posts/vulnerable-powerline-extenders-underline-lax-iot-security/cve@mitre.org
Exploit
Third Party Advisory
Hyperlink: https://securityintelligence.com/posts/vulnerable-powerline-extenders-underline-lax-iot-security/
Source: cve@mitre.org
Resource:
Exploit
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

1160Records found

CVE-2018-16334
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-11.98% / 93.51%
||
7 Day CHG~0.00%
Published-02 Sep, 2018 | 03:00
Updated-05 Aug, 2024 | 10:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN and AC10 V15.03.06.23_CN devices. The mac parameter in a POST request is used directly in a doSystemCmd call, causing OS command injection.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10ac9_firmwareac10_firmwareac9n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-50852
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-7.98% / 91.72%
||
7 Day CHG~0.00%
Published-13 Nov, 2024 | 00:00
Updated-21 Nov, 2024 | 16:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda G3 v3.0 v15.11.0.20 was discovered to contain a command injection vulnerability via the formSetUSBPartitionUmount function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g3g3_firmwaren/ag3
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-50853
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-7.98% / 91.72%
||
7 Day CHG~0.00%
Published-13 Nov, 2024 | 00:00
Updated-21 Nov, 2024 | 16:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda G3 v3.0 v15.11.0.20 was discovered to contain a command injection vulnerability via the formSetDebugCfg function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g3g3_firmwaren/ag3
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-2764
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.73% / 71.71%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 20:31
Updated-12 Dec, 2024 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-0535
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.22% / 44.37%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 03:00
Updated-14 Nov, 2024 | 14:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda PA6 httpd portmap cgiPortMapAdd stack-based overflow

A vulnerability classified as critical was found in Tenda PA6 1.0.1.21. Affected by this vulnerability is the function cgiPortMapAdd of the file /portmap of the component httpd. The manipulation of the argument groupName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-250705 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-pa6pa6_firmwarePA6
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2019-19505
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-4.41% / 88.58%
||
7 Day CHG~0.00%
Published-25 Jun, 2020 | 19:22
Updated-05 Aug, 2024 | 02:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 is vulnerable to a stack-based buffer overflow, caused by improper bounds checking by the "Wireless" section in the web-UI. By sending a specially crafted hostname, a remote attacker could overflow a buffer and execute arbitrary code on the system or cause the application to crash.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-pa6pa6_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-8224
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.43% / 62.05%
||
7 Day CHG~0.00%
Published-27 Aug, 2024 | 23:00
Updated-13 Dec, 2024 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda G3 setDebugCfg formSetDebugCfg stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.20. This issue affects the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-g3g3_firmwareG3g3_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-6189
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.47% / 63.79%
||
7 Day CHG~0.00%
Published-20 Jun, 2024 | 14:00
Updated-01 Nov, 2024 | 14:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A301 WifiExtraSet fromSetWirelessRepeat stack-based overflow

A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a301_firmwarea301A301a301
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-41459
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.28% / 51.39%
||
7 Day CHG~0.00%
Published-24 Jul, 2024 | 00:00
Updated-02 Aug, 2024 | 04:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the PPPOEPassword parameter at ip/goform/QuickIndex.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1201_firmwarefh1201n/afh1201_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7581
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.04% / 76.59%
||
7 Day CHG~0.00%
Published-07 Aug, 2024 | 15:00
Updated-07 Aug, 2024 | 19:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A301 WifiBasicSet formWifiBasicSet stack-based overflow

A vulnerability classified as critical has been found in Tenda A301 15.13.08.12. This affects the function formWifiBasicSet of the file /goform/WifiBasicSet. The manipulation of the argument security leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a301_firmwarea301A301a301_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-50854
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.19% / 41.66%
||
7 Day CHG~0.00%
Published-13 Nov, 2024 | 00:00
Updated-14 Mar, 2025 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda G3 v3.0 v15.11.0.20 was discovered to contain a stack overflow via the formSetPortMapping function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g3_firmwareg3n/ag3
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-31446
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-29.95% / 96.49%
||
7 Day CHG-18.70%
Published-14 Jun, 2022 | 02:41
Updated-03 Aug, 2024 | 07:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC18 router V15.03.05.19 and V15.03.05.05 was discovered to contain a remote code execution (RCE) vulnerability via the Mac parameter at ip/goform/WriteFacMac.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac18_firmwareac18n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-27691
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.50% / 87.13%
||
7 Day CHG~0.00%
Published-15 Apr, 2021 | 23:14
Updated-03 Aug, 2024 | 21:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Command Injection in Tenda G0 routers with firmware versions v15.11.0.6(9039)_CN and v15.11.0.5(5876)_CN , and Tenda G1 and G3 routers with firmware versions v15.11.0.17(9502)_CN or v15.11.0.16(9024)_CN allows remote attackers to execute arbitrary OS commands via a crafted action/setDebugCfg request. This occurs because the "formSetDebugCfg" function executes glibc's system function with untrusted input.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g3g1g1_firmwareg0g0_firmwareg3_firmwaren/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-27692
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.58% / 84.98%
||
7 Day CHG~0.00%
Published-15 Apr, 2021 | 23:14
Updated-03 Aug, 2024 | 21:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Command Injection in Tenda G1 and G3 routers with firmware versions v15.11.0.17(9502)_CN or v15.11.0.16(9024)_CN allows remote attackers to execute arbitrary OS commands via a crafted "action/umountUSBPartition" request. This occurs because the "formSetUSBPartitionUmount" function executes the "doSystemCmd" function with untrusted input.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g3g1_firmwareg1g3_firmwaren/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-5072
Matching Score-6
Assigner-Talos
ShareView Details
Matching Score-6
Assigner-Talos
CVSS Score-7.8||HIGH
EPSS-0.59% / 68.23%
||
7 Day CHG~0.00%
Published-21 Nov, 2019 | 16:16
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the /goform/WanParameterSetting functionality of Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (AC9V1.0 Firmware V15.03.05.16multiTRU). A specially crafted HTTP POST request can cause a command injection in the DNS2 post parameters, resulting in code execution. An attacker can send HTTP POST request with command to trigger this vulnerability.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac1200_smart_dual-band_gigabit_wifiac9v1.0_firmwareTenda AC9
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-5071
Matching Score-6
Assigner-Talos
ShareView Details
Matching Score-6
Assigner-Talos
CVSS Score-7.8||HIGH
EPSS-0.43% / 62.01%
||
7 Day CHG~0.00%
Published-21 Nov, 2019 | 16:15
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the /goform/WanParameterSetting functionality of Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (AC9V1.0 Firmware V15.03.05.16multiTRU). A specially crafted HTTP POST request can cause a command injection in the DNS1 post parameters, resulting in code execution. An attacker can send HTTP POST request with command to trigger this vulnerability.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac1200_smart_dual-band_gigabit_wifiac9v1.0_firmwareTenda AC9
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-46628
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8||HIGH
EPSS-8.29% / 91.90%
||
7 Day CHG~0.00%
Published-26 Sep, 2024 | 00:00
Updated-04 Oct, 2024 | 17:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda G3 Router firmware v15.03.05.05 was discovered to contain a remote code execution (RCE) vulnerability via the usbPartitionName parameter in the formSetUSBPartitionUmount function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g3g3_firmwaren/ag3_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-45986
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.08% / 83.26%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 04:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetUSBShareInfo. This vulnerability allows attackers to execute arbitrary commands via the usbOrdinaryUserName parameter.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g3g1_firmwareg1g3_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-45987
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.08% / 83.26%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 04:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetNetCheckTools. This vulnerability allows attackers to execute arbitrary commands via the hostName parameter.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g3g1_firmwareg1g3_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-2853
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-1.90% / 82.50%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 05:00
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U setsambacfg formSetSambaConf os command injection

A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-24390
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
ShareView Details
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.04%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 19:27
Updated-16 Sep, 2024 | 16:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Command Injection Vulnerability in Fidelis Network and Deception

Vulnerability in rconfig “remote_text_file” enables an attacker with user level access to the CLI to inject user level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.

Action-Not Available
Vendor-fidelissecurityFidelis Cybersecurity
Product-deceptionnetworkFidelis DeceptionFidelis Network
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-24635
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-5.12% / 89.45%
||
7 Day CHG~0.00%
Published-29 Mar, 2021 | 19:05
Updated-04 Aug, 2024 | 15:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.5.x: 6.5.4.17 and below; Aruba Instant 8.3.x: 8.3.0.13 and below; Aruba Instant 8.5.x: 8.5.0.10 and below; Aruba Instant 8.6.x: 8.6.0.5 and below; Aruba Instant 8.7.x: 8.7.0.0 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-scalance_w1750d_firmwareinstantscalance_w1750dAruba Instant Access Points
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-23663
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.1||CRITICAL
EPSS-2.39% / 84.39%
||
7 Day CHG~0.00%
Published-16 May, 2022 | 19:30
Updated-03 Aug, 2024 | 03:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A authenticated remote command injection vulnerability was discovered in Aruba ClearPass Policy Manager version(s): 6.10.4 and below, 6.9.9 and below, 6.8.9-HF2 and below, 6.7.x and below. Aruba has released updates to ClearPass Policy Manager that address this security vulnerability.

Action-Not Available
Vendor-n/aAruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-23666
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.1||CRITICAL
EPSS-2.39% / 84.39%
||
7 Day CHG~0.00%
Published-16 May, 2022 | 19:49
Updated-03 Aug, 2024 | 03:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A authenticated remote command injection vulnerability was discovered in Aruba ClearPass Policy Manager version(s): 6.10.4 and below, 6.9.9 and below, 6.8.9-HF2 and below, 6.7.x and below. Aruba has released updates to ClearPass Policy Manager that address this security vulnerability.

Action-Not Available
Vendor-n/aAruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-24393
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
ShareView Details
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
CVSS Score-8.8||HIGH
EPSS-0.68% / 70.73%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 19:24
Updated-16 Sep, 2024 | 23:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Command Injection Vulnerability in Fidelis Network and Deception

Vulnerability in Fidelis Network and Deception CommandPost enables authenticated command injection through the web interface using the “check_vertica_upgrade” value for the “cpIp” parameter. The vulnerability could allow a specially crafted HTTP request to execute system commands on the CommandPost and return results in an HTTP response via an authenticated session. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.

Action-Not Available
Vendor-fidelissecurityFidelis Cybersecurity
Product-deceptionnetworkFidelis DeceptionFidelis Network
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-39202
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.6||HIGH
EPSS-2.31% / 84.15%
||
7 Day CHG~0.00%
Published-08 Jul, 2024 | 00:00
Updated-02 Aug, 2024 | 04:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-823X firmware - 240126 was discovered to contain a remote command execution (RCE) vulnerability via the dhcpd_startip parameter at /goform/set_lan_settings.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-823x_ax3000_firmwaredir-823x_ax3000n/adir-823x_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-24392
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
ShareView Details
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
CVSS Score-8.8||HIGH
EPSS-0.68% / 70.73%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 19:26
Updated-16 Sep, 2024 | 16:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Command Injection Vulnerability in Fidelis Network and Deception

Vulnerability in Fidelis Network and Deception CommandPost enables authenticated command injection through the web interface using the “feed_comm_test” value for the “feed” parameter. The vulnerability could allow a specially crafted HTTP request to execute system commands on the CommandPost and return results in an HTTP response via an authenticated session. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.

Action-Not Available
Vendor-fidelissecurityFidelis Cybersecurity
Product-deceptionnetworkFidelis DeceptionFidelis Network
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-24388
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
ShareView Details
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
CVSS Score-8.8||HIGH
EPSS-0.84% / 73.84%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 19:30
Updated-16 Sep, 2024 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Privileged Command Injection Vulnerability in Fidelis Network and Deception

Vulnerability in rconfig “date” enables an attacker with user level access to the CLI to inject root level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.

Action-Not Available
Vendor-fidelissecurityFidelis Cybersecurity
Product-deceptionnetworkFidelis DeceptionFidelis Network
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-42744
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-12.76% / 93.74%
||
7 Day CHG~0.00%
Published-12 Aug, 2024 | 00:00
Updated-15 Aug, 2024 | 15:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setModifyVpnUser. Authenticated Attackers can send malicious packet to execute arbitrary commands.

Action-Not Available
Vendor-n/aTOTOLINK
Product-x5000r_firmwarex5000rn/ax5000r_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-23672
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-3.90% / 87.80%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 17:52
Updated-03 Aug, 2024 | 03:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A authenticated remote command injection vulnerability was discovered in Aruba ClearPass Policy Manager version(s): 6.10.4 and below, 6.9.9 and below, 6.8.9-HF2 and below, 6.7.x and below. Aruba has released updates to ClearPass Policy Manager that address this security vulnerability.

Action-Not Available
Vendor-n/aAruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-24220
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.81% / 73.28%
||
7 Day CHG~0.00%
Published-17 Aug, 2020 | 16:03
Updated-04 Aug, 2024 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

ShopXO v1.8.1 has a command execution vulnerability. Attackers can use this vulnerability to execute arbitrary commands and gain control of the server.

Action-Not Available
Vendor-shopxon/a
Product-shopxon/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-42742
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-12.76% / 93.74%
||
7 Day CHG~0.00%
Published-12 Aug, 2024 | 00:00
Updated-13 Aug, 2024 | 20:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setUrlFilterRules. Authenticated Attackers can send malicious packet to execute arbitrary commands.

Action-Not Available
Vendor-n/aTOTOLINK
Product-x5000r_firmwarex5000rn/ax5000r_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-23665
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.1||CRITICAL
EPSS-2.39% / 84.39%
||
7 Day CHG~0.00%
Published-16 May, 2022 | 19:40
Updated-03 Aug, 2024 | 03:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A authenticated remote command injection vulnerability was discovered in Aruba ClearPass Policy Manager version(s): 6.10.4 and below, 6.9.9 and below, 6.8.9-HF2 and below, 6.7.x and below. Aruba has released updates to ClearPass Policy Manager that address this security vulnerability.

Action-Not Available
Vendor-n/aAruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-42739
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-12.76% / 93.74%
||
7 Day CHG~0.00%
Published-13 Aug, 2024 | 00:00
Updated-14 Aug, 2024 | 15:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setAccessDeviceCfg. Authenticated Attackers can send malicious packet to execute arbitrary commands.

Action-Not Available
Vendor-n/aTOTOLINK
Product-x5000r_firmwarex5000rn/ax5000r
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-3880
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-1.58% / 80.83%
||
7 Day CHG+0.31%
Published-16 Apr, 2024 | 19:00
Updated-27 Jan, 2025 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W30E WriteFacMac formWriteFacMac os command injection

A vulnerability has been found in Tenda W30E 1.0.1.25(633) and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-260914 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w30ew30e_firmwareW30Ew30e
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-24288
Matching Score-4
Assigner-Apache Software Foundation
ShareView Details
Matching Score-4
Assigner-Apache Software Foundation
CVSS Score-8.8||HIGH
EPSS-91.64% / 99.67%
||
7 Day CHG~0.00%
Published-25 Feb, 2022 | 08:30
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Apache Airflow: RCE in example DAGs

In Apache Airflow, prior to version 2.2.4, some example DAGs did not properly sanitize user-provided params, making them susceptible to OS Command Injection from the web UI.

Action-Not Available
Vendor-The Apache Software Foundation
Product-airflowApache Airflow
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-22345
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-20.04% / 95.27%
||
7 Day CHG~0.00%
Published-18 Aug, 2021 | 20:21
Updated-04 Aug, 2024 | 14:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

/graphStatus/displayServiceStatus.php in Centreon 19.10.8 allows remote attackers to execute arbitrary OS commands via shell metacharacters in the RRDdatabase_path parameter.

Action-Not Available
Vendor-n/aCENTREON
Product-centreonn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2011-0373
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-9||HIGH
EPSS-1.63% / 81.14%
||
7 Day CHG~0.00%
Published-25 Feb, 2011 | 11:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The CGI implementation on Cisco TelePresence endpoint devices with software 1.2.x through 1.5.x allows remote authenticated users to execute arbitrary commands via a malformed request, related to "command injection vulnerabilities," aka Bug ID CSCtb31685.

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-telepresence_system_1100telepresence_system_softwaretelepresence_system_1300_seriestelepresence_system_3000telepresence_system_1000telepresence_system_3200_seriestelepresence_system_500_seriesn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-29150
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.09% / 26.35%
||
7 Day CHG~0.00%
Published-27 Apr, 2023 | 22:01
Updated-17 Jan, 2025 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
CVE-2023-29150

mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands.

Action-Not Available
Vendor-myscadamySCADA Technologies
Product-mypromySCADA myPRO
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-24237
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-29.57% / 96.45%
||
7 Day CHG~0.00%
Published-21 Mar, 2022 | 17:24
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The snaptPowered2 component of Snapt Aria v12.8 was discovered to contain a command injection vulnerability. This vulnerability allows authenticated attackers to execute arbitrary commands.

Action-Not Available
Vendor-snaptn/a
Product-arian/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-24552
Matching Score-4
Assigner-TWCERT/CC
ShareView Details
Matching Score-4
Assigner-TWCERT/CC
CVSS Score-5.5||MEDIUM
EPSS-1.28% / 78.76%
||
7 Day CHG~0.00%
Published-10 Sep, 2020 | 08:40
Updated-16 Sep, 2024 | 18:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Atop Technology 3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway - Command Injection

Atop Technology industrial 3G/4G gateway contains Command Injection vulnerability. Due to insufficient input validation, the device's web management interface allows attackers to inject specific code and execute system commands without privilege.

Action-Not Available
Vendor-atoptechnologyAtop Technology
Product-se5908ase5908_firmwarese5916ase5901se5916a_firmwarese5901_firmwarese5904d_firmwarese5916se5904dse5908a_firmwarese5916_firmwarese5908se5901b_firmwarese5901b3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway SE5904D3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway SE59013G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway SE5901B3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway SE59163G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway SE5908A3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway SE59083G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway SE5916A
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-23664
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.1||CRITICAL
EPSS-2.39% / 84.39%
||
7 Day CHG~0.00%
Published-16 May, 2022 | 19:37
Updated-03 Aug, 2024 | 03:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A authenticated remote command injection vulnerability was discovered in Aruba ClearPass Policy Manager version(s): 6.10.4 and below, 6.9.9 and below, 6.8.9-HF2 and below, 6.7.x and below. Aruba has released updates to ClearPass Policy Manager that address this security vulnerability.

Action-Not Available
Vendor-n/aAruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-24394
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
ShareView Details
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
CVSS Score-8.8||HIGH
EPSS-0.68% / 70.73%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 19:22
Updated-17 Sep, 2024 | 03:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Command Injection Vulnerability in Fidelis Network and Deception

Vulnerability in Fidelis Network and Deception CommandPost enables authenticated command injection through the web interface using the “update_checkfile” value for the “filename” parameter. The vulnerability could allow a specially crafted HTTP request to execute system commands on the CommandPost and return results in an HTTP response via an authenticated session. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.

Action-Not Available
Vendor-fidelissecurityFidelis Cybersecurity
Product-deceptionnetworkFidelis DeceptionFidelis Network
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2011-0374
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-9||HIGH
EPSS-1.63% / 81.14%
||
7 Day CHG~0.00%
Published-25 Feb, 2011 | 11:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The CGI implementation on Cisco TelePresence endpoint devices with software 1.2.x through 1.5.x allows remote authenticated users to execute arbitrary commands via a malformed request, related to "command injection vulnerabilities," aka Bug ID CSCtb31659.

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-telepresence_system_1100telepresence_system_softwaretelepresence_system_1300_seriestelepresence_system_3000telepresence_system_1000telepresence_system_3200_seriestelepresence_system_500_seriesn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-24354
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.79% / 72.94%
||
7 Day CHG~0.00%
Published-31 Aug, 2020 | 17:38
Updated-04 Aug, 2024 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Zyxel VMG5313-B30B router on firmware 5.13(ABCJ.6)b3_1127, and possibly older versions of firmware are affected by shell injection.

Action-Not Available
Vendor-n/aZyxel Networks Corporation
Product-vmg5313-b30bvmg5313-b30b_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2011-0375
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-9||HIGH
EPSS-1.63% / 81.14%
||
7 Day CHG~0.00%
Published-25 Feb, 2011 | 11:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The CGI implementation on Cisco TelePresence endpoint devices with software 1.2.x through 1.6.x allows remote authenticated users to execute arbitrary commands via a malformed request, related to "command injection vulnerabilities," aka Bug ID CSCth24671.

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-telepresence_system_1100telepresence_system_softwaretelepresence_system_1300_seriestelepresence_system_3000telepresence_system_1000telepresence_system_3200_seriestelepresence_system_500_seriesn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-42633
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8||HIGH
EPSS-11.01% / 93.15%
||
7 Day CHG~0.00%
Published-19 Aug, 2024 | 00:00
Updated-20 Aug, 2024 | 16:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection vulnerability exists in the do_upgrade_post function of the httpd binary in Linksys E1500 v1.0.06.001. As a result, an authenticated attacker can execute OS commands with root privileges.

Action-Not Available
Vendor-n/aLinksys Holdings, Inc.
Product-e1500_firmwaree1500n/ae1500_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-42747
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.3||HIGH
EPSS-2.08% / 83.30%
||
7 Day CHG~0.00%
Published-12 Aug, 2024 | 00:00
Updated-13 Aug, 2024 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setWanIeCfg. Authenticated Attackers can send malicious packet to execute arbitrary commands.

Action-Not Available
Vendor-n/aTOTOLINK
Product-x5000r_firmwarex5000rn/ax5000r_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-2261
Matching Score-4
Assigner-Jenkins Project
ShareView Details
Matching Score-4
Assigner-Jenkins Project
CVSS Score-8.8||HIGH
EPSS-0.25% / 47.75%
||
7 Day CHG~0.00%
Published-16 Sep, 2020 | 13:20
Updated-04 Aug, 2024 | 07:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Jenkins Perfecto Plugin 1.17 and earlier executes a command on the Jenkins controller, allowing attackers with Job/Configure permission to run arbitrary commands on the Jenkins controller

Action-Not Available
Vendor-Jenkins
Product-perfectoJenkins Perfecto Plugin
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-28983
Matching Score-4
Assigner-Juniper Networks, Inc.
ShareView Details
Matching Score-4
Assigner-Juniper Networks, Inc.
CVSS Score-8.8||HIGH
EPSS-0.65% / 69.77%
||
7 Day CHG~0.00%
Published-17 Apr, 2023 | 00:00
Updated-05 Feb, 2025 | 21:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Junos OS Evolved: Shell Injection vulnerability in the gNOI server

An OS Command Injection vulnerability in gRPC Network Operations Interface (gNOI) server module of Juniper Networks Junos OS Evolved allows an authenticated, low privileged, network based attacker to inject shell commands and execute code. This issue affects Juniper Networks Junos OS Evolved 21.4 version 21.4R1-EVO and later versions prior to 22.1R1-EVO.

Action-Not Available
Vendor-Juniper Networks, Inc.
Product-junos_os_evolvedJunos OS Evolved
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 23
  • 24
  • Next
Details not found