EMC Dantz Retrospect Backup Client 7.5.116 sends the password hash in cleartext at an unspecified point, which allows remote attackers to obtain sensitive information via a crafted packet.
In FiberHome VDSL2 Modem HG150-Ub_V3.0, Credentials of Admin are submitted in URL, which can be logged/sniffed.
There are few web pages associated with the genie app on the Netgear WNDR4500 running firmware version V1.0.1.40_1.0.6877. Genie app adds some capabilities over the Web GUI and can be accessed even when you are away from home. A remote attacker can access genie_ping.htm or genie_ping2.htm or genie_ping3.htm page without authentication. Once accessed, the page will be redirected to the aCongratulations2.htma page, which reveals some sensitive information such as 2.4GHz & 5GHz Wireless Network Name (SSID) and Network Key (Password) in clear text.
The ksmbd server through 3.4.2, as used in the Linux kernel through 5.15.8, sometimes communicates in cleartext even though encryption has been enabled. This occurs because it sets the SMB2_GLOBAL_CAP_ENCRYPTION flag when using the SMB 3.1.1 protocol, which is a violation of the SMB protocol specification. When Windows 10 detects this protocol violation, it disables encryption.
TOTOLINK X5000R v9.1.0u.6118_B20201102 was discovered to use the HTTP protocol for authentication into the admin interface, allowing attackers to intercept user credentials via packet capture software.
A vulnerability was found in whohas. It has been rated as problematic. This issue affects some unknown processing of the component Package Information Handler. The manipulation leads to cleartext transmission of sensitive information. The attack may be initiated remotely. The real existence of this vulnerability is still doubted at the moment. The name of the patch is 667c3e2e9178f15c23d7918b5db25cd0792c8472. It is recommended to apply a patch to fix this issue. The associated identifier of this vulnerability is VDB-216251. NOTE: Most sources redirect to the encrypted site which limits the possibilities of an attack.
BigFix Inventory up to v10.0.2 does not set the secure flag for the session cookie in an https session, which can cause the cookie to be sent in http requests and make it easier for remote attackers to capture this cookie.
Datalust Seq.App.EmailPlus (aka seq-app-htmlemail) 3.1.0-dev-00148, 3.1.0-dev-00170, and 3.1.0-dev-00176 can use cleartext SMTP on port 25 in some cases where encryption on port 465 was intended.
In phpipam/phpipam version 1.5.1, the Secure attribute for sensitive cookies in HTTPS sessions is not set. This could cause the user agent to send those cookies in plaintext over an HTTP session, potentially exposing sensitive information. The issue is fixed in version 1.7.0.
The affected products contain vulnerable firmware, which could allow an attacker to sniff the traffic and decrypt login credential details. This could give an attacker admin rights through the HTTP web server.
Cleartext transmission of sensitive information. The following products are affected: Acronis Cyber Protect 15 (Windows) before build 29240
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior have only FTP and Telnet available for device management. Any sensitive information communicated through these protocols, such as credentials, is sent in cleartext. An attacker could obtain sensitive information such as user credentials to gain access to the system.
Cleartext transmission of sensitive information. The following products are affected: Acronis Cyber Protect 15 (Linux, Windows) before build 29240
In Modem EMM, there is a possible information disclosure due to a missing data encryption. This could lead to remote information disclosure with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: MOLY00716585; Issue ID: ALPS05886933.
A vulnerability exists in libgwenhywfar through 4.12.0 due to the usage of outdated bundled CA certificates.
In all versions of GitLab CE/EE, provided a user ID, anonymous users can use a few endpoints to retrieve information about any GitLab user.
A vulnerability was found in Intergard SGS 8.7.0 and classified as problematic. Affected by this issue is some unknown functionality of the component Password Change Handler. The manipulation leads to cleartext transmission of sensitive information. The attack may be launched remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. VDB-234446 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
OKI C5510MFP Printer CU H2.15, PU 01.03.01, System F/W 1.01, and Web Page 1.00 sends the configuration of the printer in cleartext, which allows remote attackers to obtain the administrative password by connecting to TCP port 5548 or 7777.
Omron CS series, CJ series, and CP series PLCs through 2022-05-18 use cleartext passwords. They feature a UM Protection setting that allows users or system integrators to configure a password in order to restrict sensitive engineering operations (such as project/logic uploads and downloads). This password is set using the OMRON FINS command Program Area Protect and unset using the command Program Area Protect Clear, both of which are transmitted in cleartext.
The affected product is vulnerable to a cleartext transmission of sensitive information vulnerability, which may allow an attacker to capture packets to craft their own requests.
ONTAP Select Deploy administration utility versions 2.2 through 2.12.1 transmit credentials in plaintext.
IBM Cognos Analytics Mobile for Android 1.1.14 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information.
This vulnerability exist in Skyworth Router CM5100, version 4.1.1.24, due to transmission of authentication credentials in plaintext over the network. A remote attacker could exploit this vulnerability by eavesdropping on the victim’s network traffic to extract username and password from the web interface (Password Reset Page) of the vulnerable targeted system.
journalpump is a daemon that takes log messages from journald and pumps them to a given output. A logging vulnerability was found in journalpump which logs out the configuration of a service integration in plaintext to the supplied logging pipeline, including credential information contained in the configuration if any. The problem has been patched in journalpump 2.5.0.
Some device communications in some Motorola-branded Binatone Hubble Cameras with backend Hubble services are not encrypted which could lead to the communication channel being accessible by an attacker.
A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00). Affected devices do not encrypt web traffic with clients but communicate in cleartext via HTTP. This could allow an unauthenticated attacker to capture the traffic and interfere with the functionality of the device.
RICON Industrial Cellular Router S9922L 16.10.3(3794) is affected by cleartext storage of sensitive information and sends username and password as base64.
Quassel through 0.13.1, when --require-ssl is enabled, launches without SSL or TLS support if a usable X.509 certificate is not found on the local system.
An issue discovereed in EBYTE E880-IR01-V1.1 allows an attacker to obtain sensitive information via crafted POST request to /cgi-bin/luci.
This vulnerability exist in Skyworth Router CM5100, version 4.1.1.24, due to transmission of authentication credentials in plaintext over the network. A remote attacker could exploit this vulnerability by eavesdropping on the victim’s network traffic to extract username and password from the web interface (Login Page) of the vulnerable targeted system.
IBM PowerSC 1.3, 2.0, and 2.1 MFA does not implement the "HTTP Strict Transport Security" (HSTS) web security policy mechanism. IBM X-Force ID: 276004.
The affected ThroughTek P2P products (SDKs using versions before 3.1.5, any versions with nossl tag, device firmware not using AuthKey for IOTC conneciton, firmware using AVAPI module without enabling DTLS mechanism, and firmware using P2PTunnel or RDT module) do not sufficiently protect data transferred between the local device and ThroughTek servers. This can allow an attacker to access sensitive information, such as camera feeds.
While investigating DIRSTUDIO-1219 it was noticed that configured StartTLS encryption was not applied when any SASL authentication mechanism (DIGEST-MD5, GSSAPI) was used. While investigating DIRSTUDIO-1220 it was noticed that any configured SASL confidentiality layer was not applied. This issue affects Apache Directory Studio version 2.0.0.v20210213-M16 and prior versions.
A Cleartext Transmission of Sensitive Information vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote attacker to obtain sensitive information by snooping on the network traffic. The exposed data includes critical values for a pump's internal configuration.
A vulnerability was found in ISS BlackICE PC Protection. It has been declared as problematic. Affected by this vulnerability is the component Update Handler which allows cleartext transmission of data. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
D-Link DIR-865L Ax 1.20B01 Beta devices have Cleartext Transmission of Sensitive Information.
Cleartext Transmission of Sensitive Information in /northstar/Admin/login.jsp in Northstar Technologies Inc NorthStar Club Management 6.3 allows remote local user to intercept users credentials transmitted in cleartext over HTTP.
An information disclosure vulnerability exists in Visual Studio Code Live Share Extension when it exposes tokens in plain text, aka 'Visual Studio Code Live Share Information Disclosure Vulnerability'.
A vulnerability in the auto discovery phase of Cisco Spark Hybrid Calendar Service could allow an unauthenticated, remote attacker to view sensitive information in the unencrypted headers of an HTTP method request. The attacker could use this information to conduct additional reconnaissance attacks leading to the disclosure of sensitive customer data. The vulnerability exists in the auto discovery phase because an unencrypted HTTP request is made due to requirements for implementing the Hybrid Calendar service. An attacker could exploit this vulnerability by monitoring the unencrypted traffic on the network. An exploit could allow the attacker to access sensitive customer data belonging to Office365 users, such as email and calendar events. Cisco Bug IDs: CSCvg35593.
Philips Vue PACS versions 12.2.x.x and prior transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors.
LOYTEC LINX-151, LINX-212, LVIS-3ME12-A1, LIOB-586, LIOB-580 V2, LIOB-588, L-INX Configurator devices (all versions) use cleartext HTTP for login.
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device.
If Thunderbird is configured to use STARTTLS for an IMAP server, and the server sends a PREAUTH response, then Thunderbird will continue with an unencrypted connection, causing email data to be sent without protection. This vulnerability affects Thunderbird < 68.9.0.
Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker with access to the network could observe sensitive treatment and prescription data sent between the Phoenix system and the Exalis tool.
LOYTEC LINX-151, LINX-212, LVIS-3ME12-A1, LIOB-586, LIOB-580 V2, LIOB-588, L-INX Configurator devices (all versions) send password-change requests via cleartext HTTP.
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device.
TYPO3 7.6.15 sends an http request to an index.php?loginProvider URI in cases with an https Referer, which allows remote attackers to obtain sensitive cleartext information by sniffing the network and reading the userident and username fields.
An issue was discovered in Castle Rock SNMPc Online 12.10.10 before 2020-01-28. It includes the username and password values in cleartext within each request's cookie value.
LOYTEC electronics GmbH LINX Configurator (all versions) uses HTTP Basic Authentication, which transmits usernames and passwords in base64-encoded cleartext and allows remote attackers to steal the password and gain full control of Loytec device configuration.
Sigma Spectrum Infusion System v's6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application layer uses an unauthenticated clear-text communication channel to send and receive system status and operational data. This could allow an attacker that has circumvented network security measures to view sensitive non-private data or to perform a man-in-the-middle attack.