In Honeywell Performance IP Cameras and Performance NVRs, the integrated web server of the affected devices could allow remote attackers to obtain web configuration data in JSON format for IP cameras and NVRs (Network Video Recorders), which can be accessed without authentication over the network. Affected performance IP Cameras: HBD3PR2,H4D3PRV3,HED3PR3,H4D3PRV2,HBD3PR1,H4W8PR2,HBW8PR2,H2W2PC1M,H2W4PER3,H2W2PER3,HEW2PER3,HEW4PER3B,HBW2PER1,HEW4PER2,HEW4PER2B,HEW2PER2,H4W2PER2,HBW2PER2,H4W2PER3, and HPW2P1. Affected Performance Series NVRs: HEN08104,HEN08144,HEN081124,HEN16104,HEN16144,HEN16184,HEN16204,HEN162244,HEN16284,HEN16304,HEN16384,HEN32104,HEN321124,HEN32204,HEN32284,HEN322164,HEN32304, HEN32384,HEN323164,HEN64204,HEN64304,HEN643164,HEN643324,HEN643484,HEN04103,HEN04113,HEN04123,HEN08103,HEN08113,HEN08123,HEN08143,HEN16103,HEN16123,HEN16143,HEN16163,HEN04103L,HEN08103L,HEN16103L,HEN32103L.
In IP-AK2 Access Control Panel Version 1.04.07 and prior, the integrated web server of the affected devices could allow remote attackers to obtain web configuration data, which can be accessed without authentication over the network.
Missing Authentication for Critical Function vulnerability in Honeywell OneWireless allows Authentication Bypass. This issue affects OneWireless version 322.1
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. Password is stored in clear text.
Honeywell Experion PKS C200, C200E, C300, and ACE controllers are vulnerable to relative path traversal, which may allow an attacker access to unauthorized files and directories.
C300 information leak due to an analysis feature which allows extracting more memory over the network than required by the function. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.
Server information leak of configuration data when an error is generated in response to a specially crafted message. See Honeywell Security Notification for recommendations on upgrading and versioning.
Experion server may experience a DoS due to a heap overflow which could occur when handling a specially crafted message
A directory traversal vulnerability exists in the confd.exe module in Honeywell Experion PKS R40x before R400.6, R41x before R410.6, and R43x before R430.2, which could lead to possible information disclosure. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version.
Honeywell Tuxedo Touch before 5.2.19.0_VA relies on client-side authentication involving JavaScript, which allows remote attackers to bypass intended access restrictions by removing USERACCT requests from the client-server data stream.
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. Any user is able to disclose a password by accessing a specific URL, because of Plaintext Storage of a Password.
Experion server may experience a DoS due to a stack overflow when handling a specially crafted message.
ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes unencrypted passwords on the network.
ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes a session token on the network.
Honeywell Experion LX through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0055, there is a Honeywell Experion LX Control Data Access (CDA) EpicMo protocol with unauthenticated functionality issue. The affected components are characterized as: Honeywell Control Data Access (CDA) EpicMo (55565/TCP). The potential impact is: Firmware manipulation, Denial of service. The Honeywell Experion LX Distributed Control System (DCS) utilizes the Control Data Access (CDA) EpicMo protocol (55565/TCP) for device diagnostics and maintenance purposes. This protocol does not have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocol in question. An attacker capable of invoking the protocols' functionalities could issue firmware download commands potentially allowing for firmware manipulation and reboot devices causing denial of service.
Honeywell Experion PKS Safety Manager through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0051, there is a Honeywell Experion PKS Safety Manager multiple proprietary protocols with unauthenticated functionality issue. The affected components are characterized as: Honeywell Experion TCP (51000/TCP), Safety Builder (51010/TCP). The potential impact is: Manipulate controller state, Manipulate controller configuration, Manipulate controller logic, Manipulate controller files, Manipulate IO. The Honeywell Experion PKS Distributed Control System (DCS) Safety Manager utilizes several proprietary protocols for a wide variety of functionality, including process data acquisition, controller steering and configuration management. These protocols include: Experion TCP (51000/TCP) and Safety Builder (51010/TCP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocols in question. An attacker capable of invoking the protocols' functionalities could achieve a wide range of adverse impacts, including (but not limited to), the following: for Experion TCP (51000/TCP): Issue IO manipulation commands, Issue file read/write commands; and for Safety Builder (51010/TCP): Issue controller start/stop commands, Issue logic download/upload commands, Issue file read commands, Issue system time change commands. A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.
D-Link routers with the mydlink feature have some web interfaces without authentication requirements. An attacker can remotely obtain users' DNS query logs and login logs. Vulnerable targets include but are not limited to the latest firmware versions of DIR-817LW (A1-1.04), DIR-816L (B1-2.06), DIR-816 (B1-2.06?), DIR-850L (A1-1.09), and DIR-868L (A1-1.10).
Zoho ManageEngine ServiceDesk Plus before 13001 allows anyone to know the organisation's default currency name.
Missing authentication for critical function vulnerability in the webapi component in Synology Drive Server before 3.0.4-12699, 3.2.1-23280, 3.5.0-26085 and 3.5.1-26102 allows remote attackers to obtain administrator credentials via unspecified vectors.
A vulnerability is in the 'live_mfg.html' page of the WAVLINK AC1200, version WAVLINK-A42W-1.27.6-20180418, which can allow a remote attacker to access this page without any authentication. When processed, it exposes some key information of the manager of router.
In TOTOLINK EX1200T V4.1.2cu.5215, an attacker can obtain sensitive information (wifikey, etc.) without authorization through getSysStatusCfg.
An issue was discovered on Samsung mobile devices with N(7.x) and O(8.x) software. S-Voice leaks keyboard learned words via the lock screen. The Samsung ID is SVE-2018-12981 (February 2019).
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may enumerate the user names and facility names in use on a particular installation.
FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. By default, SIP requests of the type SUBSCRIBE are not authenticated in the affected versions of FreeSWITCH. Abuse of this security issue allows attackers to subscribe to user agent event notifications without the need to authenticate. This abuse poses privacy concerns and might lead to social engineering or similar attacks. For example, attackers may be able to monitor the status of target SIP extensions. Although this issue was fixed in version v1.10.6, installations upgraded to the fixed version of FreeSWITCH from an older version, may still be vulnerable if the configuration is not updated accordingly. Software upgrades do not update the configuration by default. SIP SUBSCRIBE messages should be authenticated by default so that FreeSWITCH administrators do not need to explicitly set the `auth-subscriptions` parameter. When following such a recommendation, a new parameter can be introduced to explicitly disable authentication.
An unauthenticated remote attacker can get read access to files in the "/tmp" directory due to missing authentication.
openstack-utils openstack-db has insecure password creation
userfiles/modules/users/controller/controller.php in Microweber before 1.1.20 allows an unauthenticated user to disclose the users database via a /modules/ POST request.
An issue was discovered where there are multiple externally accessible pages that do not require any sort of authentication, and store system information for internal usage. The devices automatically query these pages to update dashboards and other statistics, but the pages can be accessed externally without any authentication. All the pages follow the naming convention live_(string).shtml. Among the information disclosed is: interface status logs, IP address of the device, MAC address of the device, model and current firmware version, location, all running processes, all interfaces and their statuses, all current DHCP leases and the associated hostnames, all other wireless networks in range of the router, memory statistics, and components of the configuration of the device such as enabled features. Affected devices: Affected devices are: Wavlink WN530HG4, Wavlink WN575A3, Wavlink WN579G3,Wavlink WN531G3, Wavlink WN533A8, Wavlink WN531A6, Wavlink WN551K1, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, WN572HG3, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000
A flaw was found in the CloudForms web interface, versions 5.8 - 5.10, where the RSS feed URLs are not properly restricted to authenticated users only. An attacker could use this flaw to view potentially sensitive information from CloudForms including data such as newly created virtual machines.
All versions up to BD_R218V2.4 of ZTE MF920 product are impacted by information leak vulnerability. Due to some interfaces can obtain the WebUI login password without login, an attacker can exploit the vulnerability to obtain sensitive information about the affected components.
An information disclosure vulnerability in the /cgi-bin/ExportAllSettings.sh endpoint of the WAVLINK WN530H4 M30H4.V5030.190403 allows an attacker to leak router settings, including cleartext login details, DNS settings, and other sensitive information without authentication.
The Amcrest IP2M-841B V2.520.AC00.18.R, Dahua IPC-XXBXX V2.622.0000000.9.R, Dahua IPC HX5X3X and HX4X3X V2.800.0000008.0.R, Dahua DH-IPC HX883X and DH-IPC-HX863X V2.622.0000000.7.R, Dahua DH-SD4XXXXX V2.623.0000000.7.R, Dahua DH-SD5XXXXX V2.623.0000000.1.R, Dahua DH-SD6XXXXX V2.640.0000000.2.R and V2.623.0000000.1.R, Dahua NVR5XX-4KS2 V3.216.0000006.0.R, Dahua NVR4XXX-4KS2 V3.216.0000006.0.R, and NVR2XXX-4KS2 do not require authentication to access the HTTP endpoint /videotalk. An unauthenticated, remote person can connect to this endpoint and potentionally listen to the audio of the capturing device.
Wipro Holmes Orchestrator 20.4.1 (20.4.1_02_11_2020) allows remote attackers to download arbitrary files, such as reports containing sensitive information, because authentication is not required for API access to processexecution/DownloadExcelFile/Domain_Credential_Report_Excel, processexecution/DownloadExcelFile/User_Report_Excel, processexecution/DownloadExcelFile/Process_Report_Excel, processexecution/DownloadExcelFile/Infrastructure_Report_Excel, or processexecution/DownloadExcelFile/Resolver_Report_Excel.
Grundfos CIM 500 before v06.16.00 responds to unauthenticated requests for password storage files.
IBM Security Directory Server 6.4.0 does not perform an authentication check for a critical resource or functionality allowing anonymous users access to protected areas. IBM X-Force ID: 165953.
On 2.1.15 version and below of Lider module in LiderAhenk software is leaking it's configurations via an unsecured API. An attacker with an access to the configurations API could get valid LDAP credentials.
An issue in Plug n Play Camera com.starvedia.mCamView.zwave 5.5.1 allows a remote attacker to obtain sensitive information via the firmware update process
Insecure permissions in the component /api/admin/user of 14Finger v1.1 allows attackers to access all user information via a crafted GET request.
An issue in Shelly com.home.shelly 1.0.4 allows a remote attacker to obtain sensitive information via the firmware update process
A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE. The vulnerability allows a user from a remote system with FTView to send a packet to the customer’s server to view an HMI project. Due to the lack of proper authentication, this action is allowed without proper authentication verification.
antd-admin 5.5.0 is affected by an incorrect access control vulnerability. Unauthorized access to some interfaces in the foreground leads to leakage of sensitive information.
Argo CD is a declarative, GitOps continuous delivery tool for Kubernetes. The vulnerability allows unauthorized access to the sensitive settings exposed by /api/v1/settings endpoint without authentication. All sensitive settings are hidden except passwordPattern. This vulnerability is fixed in 2.11.3, 2.10.12, and 2.9.17.
An issue exists on NightOwl WDB-20-V2 WDB-20-V2_20190314 devices that allows an unauthenticated user to gain access to snapshots and video streams from the doorbell. The binary app offers a web server on port 80 that allows an unauthenticated user to take a snapshot from the doorbell camera via the /snapshot URI.
A missing authentication for critical function in Fortinet FortiPortal version 6.0.0 through 6.0.15, FortiManager version 7.4.0 through 7.4.2, 7.2.0 through 7.2.5, 7.0.0 through 7.0.12, 6.4.0 through 6.4.14 allows attacker to access to the configuration of the managed devices by sending specifically crafted packets
An issue was discovered in Emote Remote Mouse through 4.0.0.0. Attackers can retrieve recently used and running applications, their icons, and their file paths. This information is sent in cleartext and is not protected by any authentication logic.
HashiCorp Vault Enterprise 0.9.2 through 1.6.2 allowed the read of license metadata from DR secondaries without authentication. Fixed in 1.6.3.
D-Link DWL-900AP+ Access Point 2.1 and 2.2 allows remote attackers to access the TFTP server without authentication and read the config.img file, which contains sensitive information such as the administrative password, the WEP encryption keys, and network configuration information.
EBM Technologies RISWEB's specific URL path is not properly controlled by permission, allowing attackers to browse specific pages and query sensitive data without login.
An issue was discovered on the NEC Aterm WG2600HP2 1.0.2. The router has a set of web service APIs for access to and setup of the configuration. Some APIs don't require authentication. An attacker could exploit this vulnerability by sending a crafted HTTP request to retrieve DHCP clients, firmware version, and network status (ex.: curl -X http://[IP]/aterm_httpif.cgi/negotiate -d "REQ_ID=SUPPORT_IF_GET").
OpenVPN 2.5.1 and earlier versions allows a remote attackers to bypass authentication and access control channel data on servers configured with deferred authentication, which can be used to potentially trigger further information leaks.