A vulnerability in the Image Signature Verification feature of Cisco NX-OS Software could allow an authenticated, local attacker with administrator-level credentials to install a malicious software image on an affected device. The vulnerability is due to improper verification of digital signatures for software images. An attacker could exploit this vulnerability by loading an unsigned software image on an affected device. A successful exploit could allow the attacker to boot a malicious software image. Note: The fix for this vulnerability requires a BIOS upgrade as part of the software upgrade. For additional information, see the Details section of this advisory. Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I7(5). Nexus 9000 Series Fabric Switches in ACI Mode are affected running software versions prior to 13.2(1l). Nexus 9000 Series Switches in Standalone NX-OS Mode are affected running software versions prior to 7.0(3)I7(5). Nexus 9500 R-Series Line Cards and Fabric Modules are affected running software versions prior to 7.0(3)F3(5).
A vulnerability in Cisco NX-OS System Software could allow an authenticated, local attacker to bypass signature verification when loading a software image. The vulnerability is due to insufficient NX-OS signature verification for software images. An authenticated, local attacker could exploit this vulnerability to bypass signature verification and load a crafted, unsigned software image on a targeted device. The attacker would need valid administrator credentials to perform this exploit. This vulnerability affects the following products running Cisco NX-OS System Software: Multilayer Director Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Unified Computing System Manager. Cisco Bug IDs: CSCvf25045, CSCvf31495.
A vulnerability in Cisco Umbrella Insights Virtual Appliances 2.1.0 and earlier could allow an authenticated, local attacker to log in to an affected virtual appliance with root privileges. The vulnerability is due to the presence of default, static user credentials for an affected virtual appliance. An attacker could exploit this vulnerability by using the hypervisor console to connect locally to an affected system and then using the static credentials to log in to an affected virtual appliance. A successful exploit could allow the attacker to log in to the affected appliance with root privileges. Cisco Bug IDs: CSCvg31220.
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. MDS 9000 Series Multilayer Switches are affected in versions prior to 6.2(27), 8.1(1b), and 8.3(2). Nexus 3500 Platform Switches are affected in versions prior to 7.0(3)I7(6). Nexus 3000 Series Switches are affected in versions prior to 7.0(3)I4(9) and 7.0(3)I7(6). Nexus 3600 Platform Switches are affected in versions prior to 7.0(3)F3(5). Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 7.3(3)D1(1), 8.2(3), and 8.3(2). Nexus 9000 Series Switches in Standalone NX-OS Mode are affected in versions prior to 7.0(3)I4(9) and7.0(3)I7(6). Nexus 9500 R-Series Line Cards and Fabric Modules are affected in versions prior to 7.0(3)F3(5).
A vulnerability in the Bash shell implementation for Cisco NX-OS Software could allow an authenticated, local attacker to escalate their privilege level to root. The attacker must authenticate with valid user credentials. The vulnerability is due to incorrect permissions of a system executable. An attacker could exploit this vulnerability by authenticating to the device and entering a crafted command at the Bash prompt. A successful exploit could allow the attacker to escalate their privilege level to root. Nexus 3000 Series Switches are affected in versions prior to 7.0(3)I7(4). Nexus 3500 Platform Switches are affected in versions prior to 7.0(3)I7(4). Nexus 3600 Platform Switches are affected in versions prior to 7.0(3)F3(5). Nexus 9000 Series Switches in Standalone NX-OS Mode are affected in versions prior to 7.0(3)I7(4). Nexus 9500 R-Series Line Cards and Fabric Modules are affected in versions prior to 7.0(3)F3(5).
A vulnerability in the debug interface of Cisco IP Phone 8800 series could allow an authenticated, local attacker to execute arbitrary commands, aka Debug Shell Command Injection. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by authenticating to the device and submitting additional command input to the affected parameter in the debug shell. Cisco Bug IDs: CSCvf80034.
A vulnerability in the CLI of Cisco NX-OS System Software could allow an authenticated, local attacker to perform a command injection attack. An attacker would need valid administrator credentials to perform this exploit. The vulnerability is due to insufficient input validation during the installation of a software patch. An attacker could exploit this vulnerability by installing a crafted patch image with the vulnerable operation occurring prior to patch activation. An exploit could allow the attacker to execute arbitrary commands on an affected system as root. This vulnerability affects the following products running Cisco NX-OS System Software: Multilayer Director Switches, Nexus 2000 Series Fabric Extenders, Nexus 5000 Series Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Unified Computing System Manager. Cisco Bug IDs: CSCvf23735, CSCvg04072.
A vulnerability in motherboard console ports of line cards for Cisco ASR 1000 Series Aggregation Services Routers and Cisco cBR-8 Converged Broadband Routers could allow an unauthenticated, physical attacker to access an affected device's operating system. The vulnerability exists because an engineering console port is available on the motherboard of the affected line cards. An attacker could exploit this vulnerability by physically connecting to the console port on the line card. A successful exploit could allow the attacker to gain full access to the affected device's operating system. This vulnerability affects only Cisco ASR 1000 Series Routers that have removable line cards and Cisco cBR-8 Converged Broadband Routers, if they are running certain Cisco IOS XE 3.16 through 16.5 releases. Cisco Bug IDs: CSCvc65866, CSCve77132.
A vulnerability in Cisco NX-OS System Software could allow an authenticated, local attacker to bypass signature verification when loading a software patch. The vulnerability is due to insufficient NX-OS signature verification for software patches. An authenticated, local attacker could exploit this vulnerability to bypass signature verification and load a crafted, unsigned software patch on a targeted device. The attacker would need valid administrator credentials to perform this exploit. This vulnerability affects the following products running Cisco NX-OS System Software: Multilayer Director Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Unified Computing System Manager. Cisco Bug IDs: CSCvf16494, CSCvf23655.
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected running software versions prior to 7.0(3)I7(4). Nexus 3600 Platform Switches are affected running software versions prior to 7.0(3)F3(5). Nexus 9000 Series Switches in Stand are affected running software versions prior to 7.0(3)F3(5).
A vulnerability in Cisco DNA Spaces: Connector could allow an authenticated, local attacker to perform a command injection attack and execute arbitrary commands on the underlying operating system as root. The vulnerability is due to insufficient validation of arguments passed to a specific CLI command. An attacker could exploit this vulnerability by including malicious input during the execution of the affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system as root.
A vulnerability in the controller authorization functionality of Cisco Nexus 9000 Series ACI Mode Switch Software could allow an authenticated, local attacker to escalate standard users with root privilege on an affected device. The vulnerability is due to a misconfiguration of certain sudoers files for the bashroot component on an affected device. An attacker could exploit this vulnerability by authenticating to the affected device with a crafted user ID, which may allow temporary administrative access to escalate privileges. A successful exploit could allow the attacker to escalate privileges on an affected device. This Vulnerability has been fixed in version 4.0(1h)
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 7.3(3)D1(1), and 8.2(3).
A vulnerability in the CLI of Cisco NX-OS System Software could allow an authenticated, local attacker to perform a command injection attack. An attacker would need valid administrator credentials to perform this exploit. The vulnerability is due to insufficient input validation of command arguments. An attacker could exploit this vulnerability by injecting crafted command arguments into a vulnerable CLI command. An exploit could allow the attacker to execute arbitrary commands as root. This vulnerability affects the following products running Cisco NX-OS System Software: Multilayer Director Switches, Nexus 2000 Series Fabric Extenders, Nexus 3000 Series Switches, Nexus 3500 Platform Switches, Nexus 5000 Series Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Switches in standalone NX-OS mode, Nexus 9500 R-Series Line Cards and Fabric Modules, Unified Computing System Manager. Cisco Bug IDs: CSCvf15113, CSCvf15122, CSCvf15125, CSCvf15131, CSCvf15143, CSCvg04088.
A vulnerability in the CLI of Cisco NX-OS Software and Cisco FXOS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Firepower 4100 Series Next-Generation Firewalls are affected running software versions prior to 2.2.2.91, 2.3.1.110, and 2.4.1.222. Firepower 9300 Security Appliance are affected running software versions prior to 2.2.2.91, 2.3.1.110, and 2.4.1.222. MDS 9000 Series Multilayer Switches are affected running software versions prior to 6.2(25) and 8.3(1). Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(5). Nexus 3500 Platform Switches are affected running software versions prior to 7.0(3)I7(5). Nexus 3600 Platform Switches are affected running software versions prior to 7.0(3)F3(5). Nexus 2000, 5500, 5600, and 6000 Series Switches are affected running software versions prior to 7.1(5)N1(1b) and 7.3(4)N1(1). Nexus 7000 and 7700 Series Switches are affected running software versions prior to 6.2(22), 7.3(3)D1(1), 8.2(3). Nexus 9000 Series Switches in Standalone NX-OS Mode are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(5). Nexus 9500 R-Series Line Cards and Fabric Modules are affected running software versions prior to 7.0(3)F3(5).
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. MDS 9000 Series Multilayer Switches are affected in versions prior to 6.2(27), 8.1(1b), and 8.3(1). Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 7.3(3)D1(1), and 8.2(3).
A vulnerability in the NX-API feature of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary code as root. The vulnerability is due to incorrect input validation in the NX-API feature. An attacker could exploit this vulnerability by sending a crafted HTTP or HTTPS request to an internal service on an affected device that has the NX-API feature enabled. A successful exploit could allow the attacker to cause a buffer overflow and execute arbitrary code as root. Note: The NX-API feature is disabled by default. MDS 9000 Series Multilayer Switches are affected in versions prior to 8.1(1). Nexus 3000 Series Switches are affected in versions prior to 7.0(3)I4(8) and 7.0(3)I7(1). Nexus 3500 Platform Switches are affected in versions prior to 6.0(2)A8(8). Nexus 3600 Platform Switches are affected in versions prior to 7.0(3)F3(5). Nexus 2000, 5500, 5600, and 6000 Series Switches are affected in versions prior to 7.3(2)N1(1). Nexus 7000 and 7700 Series Switches are affected in versions prior to 7.3(3)D1(1). Nexus 9000 Series Switches in Standalone NX-OS Mode are affected in versions prior to 7.0(3)I4(8) and 7.0(3)I7(1). Nexus 9500 R-Series Line Cards and Fabric Modules are affected in versions prior to 7.0(3)F3(5).
A vulnerability in the CLI of Cisco Unity Express could allow an authenticated, local attacker to inject arbitrary commands that are executed with root privileges. To exploit this vulnerability, an attacker would need valid administrator credentials. The vulnerability is due to improper input validation for certain CLI commands that are executed on a vulnerable system. An attacker could exploit this vulnerability by logging in to the system and sending crafted CLI commands. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system and elevate privileges to root.
A vulnerability in the background operations functionality of Cisco Nexus 9000 Series Application Centric Infrastructure (ACI) Mode Switch Software could allow an authenticated, local attacker to gain elevated privileges as root on an affected device. The vulnerability is due to insufficient validation of user-supplied files on an affected device. An attacker could exploit this vulnerability by logging in to the CLI of the affected device and creating a crafted file in a specific directory on the filesystem. A successful exploit could allow the attacker to execute arbitrary operating system commands as root on an affected device.
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. Nexus 3500 Platform Switches and Nexus 3000 Series Switches software versions prior to 7.0(3)I7(4) are affected.
An untrusted search path (aka DLL Preload) vulnerability in the Cisco Network Academy Packet Tracer software could allow an authenticated, local attacker to execute arbitrary code via DLL hijacking if a local user with administrative privileges executes the installer in the current working directory where a crafted DLL has been placed by an attacker. The vulnerability is due to incomplete input validation of path and file names of a DLL file before it is loaded. An attacker could exploit this vulnerability by creating a malicious DLL file and installing it in a specific system directory. A successful exploit could allow the attacker to execute commands on the underlying Microsoft Windows host with privileges equivalent to the SYSTEM account. An attacker would need valid user credentials to exploit this vulnerability.
A vulnerability in the user account management interface of Cisco NX-OS Software could allow an authenticated, local attacker to gain elevated privileges on an affected device. The vulnerability is due to an incorrect authorization check of user accounts and their associated Group ID (GID). An attacker could exploit this vulnerability by taking advantage of a logic error that will permit the use of higher privileged commands than what is necessarily assigned. A successful exploit could allow an attacker to execute commands with elevated privileges on the underlying Linux shell of an affected device. Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 8.2(3), and 8.3(2). Nexus 3000 Series Switches are affected in versions prior to 7.0(3)I7(4). Nexus 3500 Platform Switches are affected in versions prior to 7.0(3)I7(4). Nexus 3600 Platform Switches are affected in versions prior to 7.0(3)F3(5). Nexus 9000 Series Switches-Standalone are affected in versions prior to 7.0(3)I7(4). Nexus 9500 R-Series Line Cards and Fabric Modules are affected in versions prior to 7.0(3)F3(5).
A vulnerability in the restricted shell of the Cisco Identity Services Engine (ISE) that is accessible via SSH could allow an authenticated, local attacker to run arbitrary CLI commands with elevated privileges. The vulnerability is due to incomplete input validation of the user input for CLI commands issued at the restricted shell. An attacker could exploit this vulnerability by authenticating to the targeted device and executing commands that could lead to elevated privileges. An attacker would need valid user credentials to the device to exploit this vulnerability. The vulnerability affects the following Cisco Identity Services Engine (ISE) products running Release 1.4, 2.0, 2.0.1, 2.1.0: ISE, ISE Express, ISE Virtual Appliance. Cisco Bug IDs: CSCve74916.
The Cisco AMP For Endpoints application allows an authenticated, local attacker to access a static key value stored in the local application software. The vulnerability is due to the use of a static key value stored in the application used to encrypt the connector protection password. An attacker could exploit this vulnerability by gaining local, administrative access to a Windows host and stopping the Cisco AMP for Endpoints service. Cisco Bug IDs: CSCvg42904.
The Microsoft Device Guard on Microsoft Windows 10 Gold, 1511, 1607, and 1703, and Windows Server 2016 allows a security feature bypass by the way it handles Windows PowerShell sessions, aka "Microsoft Windows Security Feature Bypass".
A vulnerability in the filesystem permissions of Cisco NX-OS Software could allow an authenticated, local attacker to gain read and write access to a critical configuration file. The vulnerability is due to a failure to impose strict filesystem permissions on the targeted device. An attacker could exploit this vulnerability by accessing and modifying restricted files. A successful exploit could allow an attacker to use the content of this configuration file to bypass authentication and log in as any user of the device. MDS 9000 Series Multilayer Switches are affected in versions prior to 6.2(25), 8.1(1b), and 8.3(1). Nexus 3000 Series Switches are affected in versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected in versions prior to 6.0(2)A8(10) and 7.0(3)I7(4). Nexus 3600 Platform Switches are affected in versions prior to 7.0(3)F3(5). Nexus 2000, 5500, 5600, and 6000 Series Switches are affected in versions prior to 7.1(5)N1(1b) and 7.3(3)N1(1). Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 7.3(3)D1(1), and 8.2(3). Nexus 9000 Series Switches-Standalone are affected in versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 9500 R-Series Line Cards and Fabric Modules are affected in versions prior to 7.0(3)F3(5).
A vulnerability in a specific CLI command implementation of Cisco Nexus 9000 Series ACI Mode Switch Software could allow an authenticated, local attacker to escape a restricted shell on an affected device. The vulnerability is due to insufficient sanitization of user-supplied input when issuing a specific CLI command with parameters on an affected device. An attacker could exploit this vulnerability by authenticating to the device CLI and issuing certain commands. A successful exploit could allow the attacker to escape the restricted shell and execute arbitrary commands with root-level privileges on the affected device. This vulnerability only affects Cisco Nexus 9000 Series ACI Mode Switches that are running a release prior to 14.0(3d).
A vulnerability in the CLI of Cisco SD-WAN Solution could allow an authenticated, local attacker to elevate lower-level privileges to the root user on an affected device. The vulnerability is due to insufficient authorization enforcement. An attacker could exploit this vulnerability by authenticating to the targeted device and executing commands that could lead to elevated privileges. A successful exploit could allow the attacker to make configuration changes to the system as the root user.
A vulnerability in the Bash shell implementation for Cisco NX-OS Software could allow an authenticated, local attacker to escalate their privilege level by executing commands authorized to other user roles. The attacker must authenticate with valid user credentials. The vulnerability is due to the incorrect implementation of a Bash shell command that allows role-based access control (RBAC) to be bypassed. An attacker could exploit this vulnerability by authenticating to the device and entering a crafted command at the Bash prompt. A successful exploit could allow the attacker to escalate their privilege level by executing commands that should be restricted to other roles. For example, a dev-ops user could escalate their privilege level to admin with a successful exploit of this vulnerability.
A vulnerability in the CLI of Cisco UCS Central Software could allow an authenticated, local attacker to gain shell access. The vulnerability is due to insufficient input validation of commands entered in the CLI, aka a Restricted Shell Break Vulnerability. An attacker could exploit this vulnerability by entering a specific command with crafted arguments. An exploit could allow the attacker to gain shell access to the underlying system. Cisco Bug IDs: CSCve70762.
A vulnerability in Cisco DNA Spaces: Connector could allow an authenticated, local attacker to elevate privileges and execute arbitrary commands on the underlying operating system as root. The vulnerability is due to insufficient restrictions during the execution of an affected CLI command. An attacker could exploit this vulnerability by leveraging the insufficient restrictions to modify sensitive files. A successful exploit could allow the attacker to elevate privileges and execute arbitrary commands on the underlying operating system as root.
Valve Steam Client for Windows through 2019-08-16 allows privilege escalation (to NT AUTHORITY\SYSTEM) because local users can replace the current versions of SteamService.exe and SteamService.dll with older versions that lack the CVE-2019-14743 patch.
An elevation of privilege vulnerability exists when the Windows AppX Deployment Server improperly handles junctions.To exploit this vulnerability, an attacker would first have to gain execution on the victim system, aka 'Windows Elevation of Privilege Vulnerability'. This CVE ID is unique from CVE-2019-1476.
An elevation of privilege vulnerability exists when Windows AppX Deployment Service (AppXSVC) improperly handles hard links, aka 'Windows Elevation of Privilege Vulnerability'. This CVE ID is unique from CVE-2019-1483.
A local privilege escalation vulnerability exists in Trend Micro Security 2019 (v15.0) in which, if exploited, would allow an attacker to manipulate a specific product feature to load a malicious service.
Use-after-free vulnerability in win32k.sys in the kernel-mode drivers in Microsoft Windows XP SP2 and SP3, Windows Server 2003 SP2, Windows Vista SP1 and SP2, Windows Server 2008 Gold, SP2, R2, and R2 SP1, and Windows 7 Gold and SP1 allows local users to gain privileges via a crafted application that leverages incorrect driver object management, a different vulnerability than other "Vulnerability Type 1" CVEs listed in MS11-034, aka "Win32k Use After Free Vulnerability."
An elevation of privilege vulnerability exists in Windows when the Win32k component fails to properly handle objects in memory, aka 'Win32k Elevation of Privilege Vulnerability'.
A vulnerability in the CLI of Cisco TelePresence Collaboration Endpoint (CE) Software could allow an authenticated, local attacker to execute arbitrary commands with root privileges. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by authenticating as the remote support user and submitting malicious input to a specific command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system (OS) with root privileges.
An elevation of privilege vulnerability exists when the Windows Printer Service improperly validates file paths while loading printer drivers, aka 'Windows Printer Service Elevation of Privilege Vulnerability'.
An elevation of privilege vulnerability exists when the Windows Graphics Component improperly handles objects in memory, aka 'Windows Graphics Component Elevation of Privilege Vulnerability'. This CVE ID is unique from CVE-2019-1407, CVE-2019-1433, CVE-2019-1437, CVE-2019-1438.
An elevation of privilege vulnerability exists when the Windows Graphics Component improperly handles objects in memory, aka 'Windows Graphics Component Elevation of Privilege Vulnerability'. This CVE ID is unique from CVE-2019-1433, CVE-2019-1435, CVE-2019-1437, CVE-2019-1438.
An elevation of privilege vulnerability exists in Windows when the Windows kernel-mode driver fails to properly handle objects in memory, aka 'Win32k Elevation of Privilege Vulnerability'. This CVE ID is unique from CVE-2019-1393, CVE-2019-1394, CVE-2019-1395, CVE-2019-1396, CVE-2019-1408.
An elevation of privilege vulnerability exists when Windows CloudStore improperly handles file Discretionary Access Control List (DACL), aka 'Microsoft Windows CloudStore Elevation of Privilege Vulnerability'.
An elevation of privilege vulnerability exists when the Windows Graphics Component improperly handles objects in memory, aka 'Windows Graphics Component Elevation of Privilege Vulnerability'. This CVE ID is unique from CVE-2019-1407, CVE-2019-1433, CVE-2019-1435, CVE-2019-1437.
Windows Event Tracing Elevation of Privilege Vulnerability
An elevation of privilege vulnerability exists when the Windows Graphics Component improperly handles objects in memory, aka 'Windows Graphics Component Elevation of Privilege Vulnerability'. This CVE ID is unique from CVE-2019-1407, CVE-2019-1433, CVE-2019-1435, CVE-2019-1438.
An elevation of privilege vulnerability exists when the Windows kernel fails to properly handle objects in memory, aka 'Windows Kernel Elevation of Privilege Vulnerability'.
An elevation of privilege vulnerability exists when umpo.dll of the Power Service, improperly handles a Registry Restore Key function, aka 'Windows Power Service Elevation of Privilege Vulnerability'.
All versions of NVIDIA Windows GPU Display Driver contain a vulnerability in the kernel mode layer (nvlddmkm.sys) handler where a value passed from a user to the driver is not correctly validated and used as the index to an array, leading to denial of service or potential escalation of privileges.
An elevation of privilege vulnerability exists when Windows Error Reporting manager improperly handles hard links, aka 'Windows Error Reporting Manager Elevation of Privilege Vulnerability'. This CVE ID is unique from CVE-2019-1315, CVE-2019-1342.