Vulnerability in Tenable Tenable.Io, Tenable Nessus, Tenable Security Center.This issue affects Tenable.Io: before Plugin Feed ID #202306261202 ; Nessus: before Plugin Feed ID #202306261202 ; Security Center: before Plugin Feed ID #202306261202 . This vulnerability could allow a malicious actor with sufficient permissions on a scan target to place a binary in a specific filesystem location, and abuse the impacted plugin in order to escalate privileges.
Under certain conditions, Nessus Network Monitor could allow a low privileged user to escalate privileges to NT AUTHORITY\SYSTEM on Windows hosts by replacing a specially crafted file.
Chunghwa Telecom NOKIA G-040W-Q has a vulnerability of weak password requirements. A remote attacker with regular user privilege can easily infer the administrator password from system information after logging system, resulting in admin access and performing arbitrary system operations or disrupt service.
In NOKIA 1350 OMS R14.2, multiple OS Command Injection vulnerabilities occurs. This allows authenticated users to execute commands on the operating system.
In Nokia One-NDS (aka Network Directory Server) through 20.9, some Sudo permissions can be exploited by some users to escalate to root privileges and execute arbitrary commands.
Grandstream GWN7000 firmware version 1.0.9.4 and below allows authenticated remote users to modify the system's crontab via undocumented API. An attacker can use this functionality to execute arbitrary OS commands on the router.
Multiple Improper Access Control was discovered in Nokia AirFrame BMC Web GUI < R18 Firmware v4.13.00. It does not properly validate requests for access to (or editing of) data and functionality in all endpoints under /#settings/* and /api/settings/*. By not verifying the permissions for access to resources, it allows a potential attacker to view pages, with sensitive data, that are not allowed, and modify system configurations also causing DoS, which should be accessed only by user with administration profile, bypassing all controls (without checking for user identity).
An issue was discovered in Nokia NetAct before 22 FP2211. On the Working Set Manager page, users can create a Working Set with a name that has a client-side template injection payload. Input validation is missing during creation of the working set. For an external attacker, it is very difficult to exploit this, because a few dynamically created parameters such as Jsession-id, a CSRF token, and an Nxsrf token would be needed. The attack can realistically only be performed by an internal user.
An issue was discovered in Nokia NetAct 22 through the Administration of Measurements website section. A malicious user can edit or add the templateName parameter in order to include malicious code, which is then downloaded as a .csv or .xlsx file and executed on a victim machine. Here, the /aom/html/EditTemplate.jsf and /aom/html/ViewAllTemplatesPage.jsf templateName parameter is used.
An issue was discovered in Nokia NetAct 22. A remote user, authenticated to the website, can visit the Site Configuration Tool section and arbitrarily upload potentially dangerous files without restrictions via the /netact/sct dir parameter in conjunction with the operation=upload value.
The Alcatel Lucent I-240W-Q GPON ONT using firmware version 3FE54567BOZJ19 is vulnerable to command injection via crafted HTTP request sent by a remote, authenticated attacker to /GponForm/usb_restore_Form?script/.
Nokia FastMile 3TG00118ABAD52 devices allow privilege escalation by an authenticated user via is_ctc_admin=1 to login_web_app.cgi and use of Import Config File.
The Alcatel Lucent I-240W-Q GPON ONT using firmware version 3FE54567BOZJ19 is vulnerable to authenticated command injection via crafted HTTP request sent by a remote, authenticated attacker to /GponForm/device_Form?script/.
SecurityCenter versions 5.5.0, 5.5.1 and 5.5.2 contain a SQL Injection vulnerability that could be exploited by an authenticated user with sufficient privileges to run diagnostic scans. An attacker could exploit this vulnerability by entering a crafted SQL query into the password field of a diagnostic scan within SecurityCenter. Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access.
Nokia IMPACT < 18A: An unrestricted File Upload vulnerability was found that may lead to Remote Code Execution.
An issue was discovered in NOKIA AMS 9.7.05. Remote Code Execution exists via the debugger of the ipAddress variable. A remote user, authenticated to the AMS server, could inject code in the PING function. The privileges of the command executed depend on the user that runs the service.
In NOKIA 1350 OMS R14.2, multiple SQL Injection vulnerabilities occurs. Exploitation requires an authenticated attacker. Through the injection of arbitrary SQL statements, a potential authenticated attacker can modify query syntax and perform unauthorized (and unexpected) operations against the remote database.
In NOKIA NFM-T R19.9, a SQL Injection vulnerability occurs in /cgi-bin/R19.9/easy1350.pl of the VM Manager WebUI via the id or host HTTP GET parameter. An authenticated attacker is required for exploitation.
In NOKIA NFM-T R19.9, an OS Command Injection vulnerability occurs in /cgi-bin/R19.9/log.pl of the VM Manager WebUI via the cmd HTTP GET parameter. This allows authenticated users to execute commands, with root privileges, on the operating system.
An arbitrary file write vulnerability exists where an authenticated attacker with privileges on the managing application could alter Nessus Rules variables to overwrite arbitrary files on the remote host, which could lead to a denial of service condition.
An arbitrary file write vulnerability exists where an authenticated, remote attacker with administrator privileges on the Nessus application could alter Nessus Rules variables to overwrite arbitrary files on the remote host, which could lead to a denial of service condition.
The Alcatel Lucent I-240W-Q GPON ONT using firmware version 3FE54567BOZJ19 is vulnerable to a stack buffer overflow via crafted HTTP POST request sent by a remote, unauthenticated attacker to /GponForm/fsetup_Form. An attacker can leverage this vulnerability to potentially execute arbitrary code.
An issue was discovered in heif through v3.6.2. A global-buffer-overflow exists in the function HevcDecoderConfigurationRecord::getPicHeight() located in hevcdecoderconfigrecord.cpp. It allows an attacker to cause code Execution.
An issue was discovered in heif through v3.6.2. A global-buffer-overflow exists in the function HevcDecoderConfigurationRecord::getPicWidth() located in hevcdecoderconfigrecord.cpp. It allows an attacker to cause code Execution.
The affected product’s code base doesn’t properly control arguments for specific functions, which could lead to a stack overflow.
A vulnerability was determined in Tenda AC20 16.03.08.12. This issue affects the function sub_48E628 of the file /goform/SetIpMacBind. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this vulnerability is the function setLan of the file /goform/setLan. The manipulation of the argument lan2enabled leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This affects the function portTriggerManageRule of the file /goform/portTriggerManageRule. The manipulation of the argument triggerRuleName/schedule leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this issue is the function inboundFilterAdd of the file /goform/inboundFilterAdd. Executing manipulation of the argument ruleName can lead to stack-based buffer overflow. The attack may be performed from a remote location. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
A security vulnerability has been detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this issue is the function RP_doSpecifySiteSurvey of the file /goform/RP_doSpecifySiteSurvey. The manipulation of the argument ssidhex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected is the function setOpMode of the file /goform/setOpMode. The manipulation of the argument ethConv leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was detected in Tenda i22 1.0.0.3(4687). This impacts the function formWeixinAuthInfoGet of the file /goform/wxportalauth. Performing manipulation of the argument Type results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.
A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This impacts the function setPWDbyBBS of the file /goform/setPWDbyBBS. Such manipulation of the argument hint leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in D-Link DIR-513 1.0. It has been rated as critical. Affected by this issue is the function sprintf of the file /goform/formLanSetupRouterSettings of the component Boa Webserver. The manipulation of the argument curTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A security flaw has been discovered in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function setSysAdm of the file /goform/setSysAdm. The manipulation of the argument admpasshint results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in D-Link DI-8100 1.0. It has been declared as critical. Affected by this vulnerability is the function sprintf of the file /ddns.asp?opt=add of the component jhttpd. The manipulation of the argument mx leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. The affected element is the function ipRangeBlockManageRule of the file /goform/ipRangeBlockManageRule. Performing manipulation of the argument ipRangeBlockRuleName/scheduleIp/ipRangeBlockRuleIpAddr results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in TOTOLINK X15 1.0.0-B20230714.1105 and classified as critical. This issue affects some unknown processing of the file /boafrm/formMapDel of the component HTTP POST Request Handler. The manipulation of the argument devicemac1 leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was identified in Tenda AC20 16.03.08.12. This issue affects the function sub_46A2AC of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This vulnerability affects the function setDMZ of the file /goform/setDMZ. The manipulation of the argument DMZIPAddress leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. The impacted element is the function RP_pingGatewayByBBS of the file /goform/RP_pingGatewayByBBS. The manipulation of the argument ssidhex results in stack-based buffer overflow. The attack may be performed from a remote location. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this issue is the function setRIP of the file /goform/setRIP. The manipulation of the argument RIPmode/RIPpasswd leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This affects the function langSwitchByBBS of the file /goform/langSwitchByBBS. The manipulation of the argument langSelectionOnly leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected is the function algDisable of the file /goform/setOpMode. The manipulation of the argument opMode leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A security flaw has been discovered in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected is the function sta_wps_pin of the file /goform/sta_wps_pin. Performing manipulation of the argument Ssid results in stack-based buffer overflow. The attack can be initiated remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical was found in Tenda AC20 16.03.08.05. Affected by this vulnerability is the function strcpy of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda AC20 16.03.08.05. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This vulnerability affects the function wirelessBasic of the file /goform/wirelessBasic. The manipulation of the argument submit_SSID1 leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been found in Tenda AC20 16.03.08.12. This affects the function set_qosMib_list of the file /goform/SetNetControlList of the component SetNetControlList Endpoint. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.