An exploitable command injection vulnerability exists in the cloud connectivity feature of WAGO PFC200. An attacker can inject operating system commands into any of the parameter values contained in the firmware update command. This affects WAGO PFC200 Firmware version 03.02.02(14), version 03.01.07(13), and version 03.00.39(12)
An exploitable command injection vulnerability exists in the cloud connectivity functionality of WAGO PFC200 versions 03.02.02(14), 03.01.07(13), and 03.00.39(12). An attacker can inject operating system commands into the TimeoutPrepared parameter value contained in the firmware update command.
An issue was discovered on WAGO e!DISPLAY 762-3000 through 762-3003 devices with firmware before FW 02. The vulnerability allows an authenticated user to upload arbitrary files to the file system with the permissions of the web server.
An exploitable code execution vulnerability exists in the Web-Based Management (WBM) functionality of WAGO PFC 200 03.03.10(15). A specially crafted series of HTTP requests can cause code execution resulting in remote code execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.
An exploitable improper host validation vulnerability exists in the Cloud Connectivity functionality of WAGO PFC200 Firmware versions 03.02.02(14), 03.01.07(13), and 03.00.39(12). A specially crafted HTTPS POST request can cause the software to connect to an unauthorized host, resulting in unauthorized access to firmware update functionality. An attacker can send an authenticated HTTPS POST request to direct the Cloud Connectivity software to connect to an attacker controlled Azure IoT Hub node.
In multiple products of WAGO a vulnerability allows an unauthenticated, remote attacker to create new users and change the device configuration which can result in unintended behaviour, Denial of Service and full system compromise.
CODESYS V2 runtime system SP before 2.4.7.55 has Improper Neutralization of Special Elements used in an OS Command.
A vulnerability in the web-based management allows an unauthenticated remote attacker to inject arbitrary system commands and gain full system control. Those commands are executed with root privileges. The vulnerability is located in the user request handling of the web-based management.
The reported vulnerability allows an attacker who has network access to the device to execute code with specially crafted packets in WAGO Series PFC 100 (750-81xx/xxx-xxx), Series PFC 200 (750-82xx/xxx-xxx), Series Wago Touch Panel 600 Standard Line (762-4xxx), Series Wago Touch Panel 600 Advanced Line (762-5xxx), Series Wago Touch Panel 600 Marine Line (762-6xxx) with firmware versions <=FW10.
An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 Firmware version 03.02.02(14). An attacker can send specially crafted packet at 0x1ea48 to the extracted hostname value from the xml file that is used as an argument to /etc/config-tools/config_interfaces interface=X1 state=enabled ip-address=<contents of ip node> using sprintf().
An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 version 03.02.02(14). A specially crafted XML cache file written to a specific location on the device can be used to inject OS commands. An attacker can send a specially crafted packet to trigger the parsing of this cache file.At 0x1e9fc the extracted subnetmask value from the xml file is used as an argument to /etc/config-tools/config_interfaces interface=X1 state=enabled subnet-mask=<contents of subnetmask node> using sprintf(). This command is later executed via a call to system().
An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 Firmware version 03.02.02(14). A specially crafted XML cache file written to a specific location on the device can be used to inject OS commands. An attacker can send a specially crafted packet to trigger the parsing of this cache file.At 0x1ea28 the extracted type value from the xml file is used as an argument to /etc/config-tools/config_interfaces interface=X1 state=enabled config-type=<contents of type node> using sprintf(). This command is later executed via a call to system().
An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 Firmware version 03.02.02(14). A specially crafted XML cache file written to a specific location on the device can be used to inject OS commands. An attacker can send a specially crafted packet to trigger the parsing of this cache file.At 0x1e87c the extracted hostname value from the xml file is used as an argument to /etc/config-tools/change_hostname hostname=<contents of hostname node> using sprintf(). This command is later executed via a call to system().
An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 version 03.02.02(14). An attacker can send a specially crafted XML cache file At 0x1e8a8 the extracted domainname value from the xml file is used as an argument to /etc/config-tools/edit_dns_server domain-name=<contents of domainname node> using sprintf().This command is later executed via a call to system().
An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 version 03.02.02(14). At 0x1e3f0 the extracted dns value from the xml file is used as an argument to /etc/config-tools/edit_dns_server %s dns-server-nr=%d dns-server-name=<contents of dns node> using sprintf(). This command is later executed via a call to system(). This is done in a loop and there is no limit to how many dns entries will be parsed from the xml file.
An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 Firmware version 03.02.02(14). An attacker can send a specially crafted packet to trigger the parsing of this cache file. At 0x1e840 the extracted ntp value from the xml file is used as an argument to /etc/config-tools/config_sntp time-server-%d=<contents of ntp node> using sprintf(). This command is later executed via a call to system(). This is done in a loop and there is no limit to how many ntp entries will be parsed from the xml file.
An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 Firmware version 03.02.02(14). A specially crafted XML cache file written to a specific location on the device can be used to inject OS commands. An attacker can send a specially crafted packet to trigger the parsing of this cache file. At 0x1e900 the extracted gateway value from the xml file is used as an argument to /etc/config-tools/config_default_gateway number=0 state=enabled value=<contents of gateway node> using sprintf(). This command is later executed via a call to system().
An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 Firmware version 03.02.02(14). A specially crafted XML cache file written to a specific location on the device can be used to inject OS commands. An attacker can send a specially crafted packet to trigger the parsing of this cache file. At 0x1e9fc the extracted state value from the xml file is used as an argument to /etc/config-tools/config_interfaces interface=X1 state=<contents of state node> using sprintf(). This command is later executed via a call to system().
A vulnerability has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this issue is the function setDFSSetting of the file /goform/setLan. The manipulation of the argument lanNetmask/lanIp leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function um_inspect_cross_band of the file /goform/RP_setBasicAuto. The manipulation of the argument staticGateway leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
An issue was discovered in PRTG Network Monitor before 18.2.39. An attacker who has access to the PRTG System Administrator web console with administrative privileges can exploit an OS command injection vulnerability (both on the server and on devices) by sending malformed parameters in sensor or notification management scenarios.
User provided input is not sanitized on the AXIS License Plate Verifier specific “api.cgi” allowing for arbitrary code execution.
User provided input is not sanitized in the “Settings > Access Control” configuration interface allowing for arbitrary code execution.
The administrative web interface in Cisco TelePresence Video Communication Server Expressway X8.5.2 allows remote authenticated users to execute arbitrary commands via crafted fields, aka Bug ID CSCuv12531.
In the web ui of the openbuildservice before 2.3.0 a code injection of the project rebuildtimes statistics could be used by authorized attackers to execute shellcode.
A vulnerability in the web UI feature of Cisco IOS XE Software could allow an authenticated, remote attacker to inject commands with the privileges of root. This vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending crafted input to the web UI. A successful exploit could allow the attacker to inject commands to the underlying operating system with root privileges.
A vulnerability was found in DCN DCME-720 9.1.5.11. This affects an unknown function of the file /usr/local/www/function/audit/newstatistics/ip_block.php of the component Web Management Backend. Performing manipulation of the argument ip results in os command injection. It is possible to initiate the attack remotely. The exploit has been made public and could be used. Other products might be affected as well. The vendor was contacted early about this disclosure but did not respond in any way.
In some Lenovo ThinkServer-branded servers, a command injection vulnerability exists in the BMC firmware download command. This allows a privileged user to download and execute arbitrary code inside the BMC. This can only be exploited by authorized privileged users.
Multiple vulnerabilities in the web management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system. The attacker would need valid device credentials but does not require administrator privileges to exploit this vulnerability. These vulnerabilities are due to insufficient validation of user-supplied input for certain configuration options. An attacker could exploit these vulnerabilities by using crafted input within the device configuration GUI. A successful exploit could allow the attacker to execute arbitrary commands on the device including the underlying operating system which could also affect the availability of the device.
A command injection vulnerability is present in Aruba Instant that permits an authenticated administrative user to execute arbitrary commands on the underlying operating system. A malicious administrator could use this ability to install backdoors or change system configuration in a way that would not be logged. Workaround: None. Resolution: Fixed in Aruba Instant 4.2.4.12, 6.5.4.11, 8.3.0.6, and 8.4.0.0
A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this vulnerability is the function setDeviceName of the file /goform/setDeviceName. The manipulation of the argument DeviceName leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability in the Cisco IOx application hosting environment could allow an authenticated, remote attacker to execute arbitrary commands as root on the underlying host operating system. This vulnerability is due to incomplete sanitization of parameters that are passed in for activation of an application. An attacker could exploit this vulnerability by deploying and activating an application in the Cisco IOx application hosting environment with a crafted activation payload file. A successful exploit could allow the attacker to execute arbitrary commands as root on the underlying host operating system.
A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this vulnerability is the function um_red of the file /goform/RP_setBasicAuto. The manipulation of the argument hname leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257667. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
InHand Networks IR615 Router's Versions 2.3.0.r4724 and 2.3.0.r4870 are vulnerable to an attacker using a ping tool to inject commands into the device. This may allow the attacker to remotely run commands on behalf of the device.
Multiple vulnerabilities in the web-based management interface of Cisco Small Business RV320 and RV325 Dual Gigabit WAN VPN Routers could allow an authenticated, remote attacker to inject and execute arbitrary commands on the underlying operating system of an affected device. These vulnerabilities are due to insufficient validation of user-supplied input. An attacker could exploit these vulnerabilities by sending malicious input to an affected device. A successful exploit could allow the attacker to execute arbitrary commands as the root user on the underlying Linux operating system of the affected device. To exploit these vulnerabilities, an attacker would need to have valid Administrator credentials on the affected device. Cisco has not released software updates to address these vulnerabilities.
InHand Networks IR615 Router's Versions 2.3.0.r4724 and 2.3.0.r4870 are vulnerable to an attacker using a traceroute tool to inject commands into the device. This may allow the attacker to remotely run commands on behalf of the device.
A vulnerability, which was classified as critical, has been found in agno-agi agno up to 1.7.5. This issue affects the function MCPTools/MultiMCPTools in the library libs/agno/agno/tools/mcp.py of the component Model Context Protocol Handler. The manipulation of the argument command leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected is the function ipv6cmd of the file /goform/setIpv6. The manipulation of the argument Ipv6PriDns/Ipv6SecDns/Ipv6StaticGateway/LanIpv6Addr/LanPrefixLen/pppoeUser/pppoePass/pppoeIdleTime/pppoeRedialPeriod/Ipv6in4_PrefixLen/LocalIpv6/RemoteIpv4/LanIPv6_Prefix/LanPrefixLen/ipv6to4Relay/ipv6rdRelay/tunrd_PrefixLen/wan_UseLinkLocal/Ipv6StaticIp/Ipv6PrefixLen leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A security vulnerability has been detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function addStaticRoute of the file /goform/addStaticRoute. Such manipulation of the argument staticRoute_IP_setting/staticRoute_Netmask_setting/staticRoute_Gateway_setting/staticRoute_Metric_setting/staticRoute_destType_setting leads to os command injection. The attack may be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
programs/pluto/xauth.c in the client in Openswan 2.6.25 through 2.6.28 allows remote authenticated gateways to execute arbitrary commands via shell metacharacters in (1) cisco_dns_info or (2) cisco_domain_info data in a packet, a different vulnerability than CVE-2010-3302.
NETGEAR Prosafe WC9500 5.1.0.17, WC7600 5.1.0.17, and WC7520 2.5.0.35 devices allow a remote attacker to execute code with root privileges via shell metacharacters in the reqMethod parameter to login_handler.php.
Multiple vulnerabilities in Cisco Identity Services Engine (ISE) could allow an authenticated attacker to perform command injection attacks on the underlying operating system and elevate privileges to root. To exploit these vulnerabilities, an attacker must have valid credentials on an affected device. For more information about these vulnerabilities, see the Details section of this advisory.
A vulnerability was found in agentUniverse up to 0.0.18 and classified as critical. This issue affects the function StdioServerParameters of the component MCPSessionManager/MCPTool/MCPToolkit. The manipulation leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A command injection vulnerability was identified in SMM/SMM2 and FPC that could allow an authenticated user with elevated privileges to execute system commands when performing a specific administrative function.
A vulnerability has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this issue is the function sub_3517C of the file /goform/setWan. The manipulation of the argument Hostname leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
An Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability [CWE-78] in FortiManager version 7.6.0, version 7.4.4 and below, version 7.2.7 and below, version 7.0.12 and below, version 6.4.14 and below and FortiManager Cloud version 7.4.4 and below, version 7.2.7 to 7.2.1, version 7.0.12 to 7.0.1 may allow an authenticated remote attacker to execute unauthorized code via FGFM crafted requests.
Silex SD-320AN version 2.01 and prior and GE MobileLink(GEH-SD-320AN) version GEH-1.1 and prior have a system call parameter that is not properly sanitized, which may allow remote code execution.
A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This affects the function RP_setBasicAuto of the file /goform/RP_setBasicAuto. The manipulation of the argument staticIp/staticNetmask leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function RP_setBasic of the file /goform/RP_setBasic. The manipulation of the argument bssid leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.