AVEVA System Platform versions 2017 through 2020 R2 P01 does not perform any authentication for functionality that requires a provable user identity.
Eaton 9000X DriveA versions 2.0.29 and prior has a stack-based buffer overflow vulnerability, which may allow remote code execution.
A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution.
A stack-based buffer overflow vulnerability has been identified in Teledyne DALSA Sherlock Version 7.2.7.4 and prior, which may allow remote code execution.
InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. A remote attacker could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability during tag, alarm, or event related actions such as read and write, with potential for code to be executed. If InduSoft Web Studio remote communication security was not enabled, or a password was left blank, a remote user could send a carefully crafted packet to invoke an arbitrary process, with potential for code to be executed. The code would be executed under the privileges of the InduSoft Web Studio or InTouch Edge HMI runtime and could lead to a compromise of the InduSoft Web Studio or InTouch Edge HMI server machine.
Heap-based buffer overflow in SuiteLink server while processing commands 0x05/0x06
The listed versions of AVEVA Plant SCADA and AVEVA Telemetry Server are vulnerable to an improper authorization exploit which could allow an unauthenticated user to remotely read data, cause denial of service, and tamper with alarm states.
InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. This vulnerability could allow an unauthenticated user to remotely execute code with the same privileges as that of the InduSoft Web Studio or InTouch Edge HMI (formerly InTouch Machine Edition) runtime.
Parameter psClass in ednareporting.asmx is vulnerable to unauthenticated SQL injection attacks. Specially crafted SOAP web requests can cause SQL injections resulting in data compromise. An attacker can send unauthenticated HTTP requests to trigger this vulnerability.
SQL injection vulnerability exists in the CHaD.asmx web service functionality of eDNA Enterprise Data Historian 3.0.1.2/7.5.4989.33053. Specially crafted SOAP web requests can cause SQL injections resulting in data compromise. Parameter ClassName in CHaD.asmx is vulnerable to unauthenticated SQL injection attacks.
AVEVA InduSoft Web Studio v8.1 and v8.1SP1, and InTouch Machine Edition v2017 8.1 and v2017 8.1 SP1 a remote user could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability during tag, alarm, or event related actions such as read and write, with potential for code to be executed.
For Crestron TSW-X60 version prior to 2.001.0037.001 and MC3 version prior to 1.502.0047.001, The devices are shipped with authentication disabled, and there is no indication to users that they need to take steps to enable it. When compromised, the access to the CTP console is left open.
An Information Exposure issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. Credentials may be exposed to external systems via specific URL parameters, as arbitrary destination addresses may be specified.
An issue was discovered in ExecuteCommand() in AVEVA Edge (formerly InduSoft Web Studio) versions R2020 and prior that allows unauthenticated arbitrary commands to be executed.
An SQL injection vulnerability exists in the CHaD.asmx web service functionality of eDNA Enterprise Data Historian 3.0.1.2/7.5.4989.33053. Specially crafted SOAP web requests can cause SQL injections resulting in data compromise. Parameter InstancePath in CHaD.asmx is vulnerable to unauthenticated SQL injection attacks.
Parameter AttFilterValue in ednareporting.asmx is vulnerable to unauthenticated SQL injection attacks. Specially crafted SOAP web requests can cause SQL injections resulting in data compromise. An attacker can send unauthenticated HTTP requests to trigger this vulnerability.
PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted.
Moxa IKS and EDS generate a predictable cookie calculated with an MD5 hash, allowing an attacker to capture the administrator's password, which could lead to a full compromise of the device.
Moxa IKS and EDS do not implement sufficient measures to prevent multiple failed authentication attempts, which may allow an attacker to discover passwords via brute force attack.
Several buffer overflow vulnerabilities have been identified in Moxa IKS and EDS, which may allow remote code execution.
Use-after-free vulnerability in Control Microsystems ClearSCADA 2005, 2007, and 2009 before R2.3 and R1.4, as used in SCX before 67 R4.5 and 68 R3.9, allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via unspecified long strings that trigger heap memory corruption.
An SQL injection vulnerability exists in the CHaD.asmx web service functionality of eDNA Enterprise Data Historian 3.0.1.2/7.5.4989.33053. Specially crafted SOAP web requests can cause SQL injections resulting in data compromise. Parameter InstanceName in CHaD.asmx is vulnerable to unauthenticated SQL injection attacks.
Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166).
By default, the Packet Power Monitoring and Control Web Interface do not enforce authentication mechanisms. This vulnerability could allow unauthorized users to access and manipulate monitoring and control functions.
WebITR developed by Uniong has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to log into the system as arbitrary users by exploiting a specific functionality.
Authentication Bypass Using an Alternate Path or Channel vulnerability in Drupal Authenticator Login allows Authentication Bypass.This issue affects Authenticator Login: from 0.0.0 before 2.1.4.
ManageEngine Log360 Builds < 5235 are affected by an improper access control vulnerability allowing database configuration overwrite. An unauthenticated remote attacker can send a specially crafted message to Log360 to change its backend database to an attacker-controlled database and to force Log360 to restart. An attacker can leverage this vulnerability to achieve remote code execution by replacing files executed by Log360 on startup.
Properly formatted POST requests to multiple resources on the HTTP and HTTPS web servers of the Digi PortServer TS 16 Rack device do not require authentication or authentication tokens. This vulnerability could allow an attacker to enable the SNMP service and manipulate the community strings to achieve further control in.
The Invoker Servlet on SAP NetWeaver Application Server Java platforms, possibly before 7.3, does not require authentication, which allows remote attackers to execute arbitrary code via an HTTP or HTTPS request, as exploited in the wild in 2013 through 2016, aka a "Detour" attack.
A vulnerability in the web-based management interface of Cisco SPA112 2-Port Phone Adapters could allow an unauthenticated, remote attacker to execute arbitrary code on an affected device. This vulnerability is due to a missing authentication process within the firmware upgrade function. An attacker could exploit this vulnerability by upgrading an affected device to a crafted version of firmware. A successful exploit could allow the attacker to execute arbitrary code on the affected device with full privileges. Cisco has not released firmware updates to address this vulnerability.
The Custom MCPs feature is designed to execute OS commands, for instance, using tools like `npx` to spin up local MCP Servers. However, Flowise's inherent authentication and authorization model is minimal and lacks role-based access controls (RBAC). Furthermore, in Flowise versions before 3.0.1 the default installation operates without authentication unless explicitly configured. This combination allows unauthenticated network attackers to execute unsandboxed OS commands.
The variable import endpoint was not protected by authentication in Airflow >=2.0.0, <2.1.3. This allowed unauthenticated users to hit that endpoint to add/modify Airflow variables used in DAGs, potentially resulting in a denial of service, information disclosure or remote code execution. This issue affects Apache Airflow >=2.0.0, <2.1.3.
The server permits communication without any authentication procedure, allowing the attacker to initiate a session with the server without providing any form of authentication.
Insufficient input validation within GitLab Language Server 7.6.0 and later before 7.30.0 allows arbitrary GraphQL query execution
The TP-LINK EAP Controller is TP-LINK's software for remotely controlling wireless access point devices. It utilizes a Java remote method invocation (RMI) service for remote control. The RMI interface does not require any authentication before use, so it lacks user authentication for RMI service commands in EAP controller versions 2.5.3 and earlier. Remote attackers can implement deserialization attacks through the RMI protocol. Successful attacks may allow a remote attacker to remotely control the target server and execute Java functions or bytecode.
A missing authentication for critical function in Fortinet FortiManager version 7.4.0 through 7.4.2, 7.2.0 through 7.2.4, 7.0.0 through 7.0.11, 6.4.0 through 6.4.14, FortiPAM version 1.2.0, 1.1.0 through 1.1.2, 1.0.0 through 1.0.3, FortiProxy version 7.4.0 through 7.4.2, 7.2.0 through 7.2.9, 7.0.0 through 7.0.17, 2.0.0 through 2.0.14, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7, FortiSwitchManager version 7.2.0 through 7.2.3, 7.0.0 through 7.0.3, FortiPortal version 6.0.0 through 6.0.14, FortiOS version 7.4.0 through 7.4.3, 7.2.0 through 7.2.7, 7.0.0 through 7.0.14, 6.4.0 through 6.4.15, 6.2.0 through 6.2.16, 6.0.0 through 6.0.18 allows attacker to execute unauthorized code or commands via specially crafted packets.
SnapCenter versions 4.7 prior to 4.7P2 and 4.8 prior to 4.8P1 are susceptible to a vulnerability which could allow a remote unauthenticated attacker to gain access as an admin user.
An unauthenticated remote attacker who is aware of a MQTT topic name can send and receive messages, including GET/SET configuration commands, reboot commands and firmware updates.
A vulnerability classified as critical was found in SourceCodester Online Pizza Ordering System 1.0. Affected by this vulnerability is the function delete_category of the file ajax.php of the component POST Parameter Handler. The manipulation leads to missing authentication. The attack can be launched remotely. The associated identifier of this vulnerability is VDB-221455.
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior allows the execution of commands without credentials. As Telnet and file transfer protocol (FTP) are the only protocols available for device management, an unauthorized user could access the system and modify the device configuration, which could result in the unauthorized user executing unrestricted malicious commands.
In JetBrains TeamCity before 2023.11.3 authentication bypass leading to RCE was possible
A vulnerability classified as critical has been found in code-projects Laundry System 1.0. This affects an unknown part of the file /data/. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the firmware of the device.
An arbitrary code execution vulnerability exists in Arris SURFboard SGB6950AC2 devices. An unauthenticated attacker can exploit this vulnerability to achieve code execution as root.
Password recovery vulnerability in SICK SIM2000ST Partnumber 2086502 with firmware version <1.13.4 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.13.4 as soon as possible (available in SICK Support Portal).
A lack of authentication vulnerability exists in the HTTP API functionality of GoCast 1.1.3. A specially crafted HTTP request can lead to arbitrary command execution. An attacker can make an unauthenticated HTTP request to trigger this vulnerability.
Nextcloud Global Site Selector is a tool which allows you to run multiple small Nextcloud instances and redirect users to the right server. A problem in the password verification method allows an attacker to authenticate as another user. It is recommended that the Nextcloud Global Site Selector is upgraded to version 1.4.1, 2.1.2, 2.3.4 or 2.4.5. There are no known workarounds for this issue.
jupyter-lsp is a coding assistance tool for JupyterLab (code navigation + hover suggestions + linters + autocompletion + rename) using Language Server Protocol. Installations of jupyter-lsp running in environments without configured file system access control (on the operating system level), and with jupyter-server instances exposed to non-trusted network are vulnerable to unauthorised access and modification of file system beyond the jupyter root directory. This issue has been patched in version 2.2.2 and all users are advised to upgrade. Users unable to upgrade should uninstall jupyter-lsp.
KubeView through 0.1.31 allows attackers to obtain control of a Kubernetes cluster because api/scrape/kube-system does not require authentication, and retrieves certificate files that can be used for authentication as kube-admin. NOTE: the vendor's position is that KubeView was a "fun side project and a learning exercise," and not "very secure."
The default configuration of Lazy Mouse does not require a password, allowing remote unauthenticated users to execute arbitrary code with no prior authorization or authentication. CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H