Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2019-6812

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-22 May, 2019 | 19:48
Updated At-04 Aug, 2024 | 20:31
Rejected At-
Credits

A CWE-798 use of hardcoded credentials vulnerability exists in BMX-NOR-0200H with firmware versions prior to V1.7 IR 19 which could cause a confidentiality issue when using FTP protocol.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:22 May, 2019 | 19:48
Updated At:04 Aug, 2024 | 20:31
Rejected At:
▼CVE Numbering Authority (CNA)

A CWE-798 use of hardcoded credentials vulnerability exists in BMX-NOR-0200H with firmware versions prior to V1.7 IR 19 which could cause a confidentiality issue when using FTP protocol.

Affected Products
Vendor
n/a
Product
Modicon RTU Module, BMX-NOR-0200H with firmware versions prior to V1.7 IR 19
Versions
Affected
  • Modicon RTU Module, BMX-NOR-0200H with firmware versions prior to V1.7 IR 19
Problem Types
TypeCWE IDDescription
CWECWE-798CWE-798: Use of hardcoded credentials
Type: CWE
CWE ID: CWE-798
Description: CWE-798: Use of hardcoded credentials
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.schneider-electric.com/en/download/document/SEVD-2019-134-06/
x_refsource_MISC
https://security.cse.iitk.ac.in/responsible-disclosure
x_refsource_MISC
Hyperlink: https://www.schneider-electric.com/en/download/document/SEVD-2019-134-06/
Resource:
x_refsource_MISC
Hyperlink: https://security.cse.iitk.ac.in/responsible-disclosure
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.schneider-electric.com/en/download/document/SEVD-2019-134-06/
x_refsource_MISC
x_transferred
https://security.cse.iitk.ac.in/responsible-disclosure
x_refsource_MISC
x_transferred
Hyperlink: https://www.schneider-electric.com/en/download/document/SEVD-2019-134-06/
Resource:
x_refsource_MISC
x_transferred
Hyperlink: https://security.cse.iitk.ac.in/responsible-disclosure
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:22 May, 2019 | 20:29
Updated At:14 Oct, 2022 | 02:55

A CWE-798 use of hardcoded credentials vulnerability exists in BMX-NOR-0200H with firmware versions prior to V1.7 IR 19 which could cause a confidentiality issue when using FTP protocol.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.17.2HIGH
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Primary2.04.0MEDIUM
AV:N/AC:L/Au:S/C:P/I:N/A:N
Type: Primary
Version: 3.1
Base score: 7.2
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 4.0
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:S/C:P/I:N/A:N
CPE Matches

Schneider Electric SE
schneider-electric
>>bmx-nor-0200h_firmware>>1.7
cpe:2.3:o:schneider-electric:bmx-nor-0200h_firmware:1.7:ir17:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmx-nor-0200h_firmware>>1.7
cpe:2.3:o:schneider-electric:bmx-nor-0200h_firmware:1.7:ir18:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>bmx-nor-0200h>>-
cpe:2.3:h:schneider-electric:bmx-nor-0200h:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-798Primarynvd@nist.gov
CWE-798Secondarycybersecurity@se.com
CWE ID: CWE-798
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-798
Type: Secondary
Source: cybersecurity@se.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://security.cse.iitk.ac.in/responsible-disclosurecybersecurity@se.com
Third Party Advisory
https://www.schneider-electric.com/en/download/document/SEVD-2019-134-06/cybersecurity@se.com
Vendor Advisory
Hyperlink: https://security.cse.iitk.ac.in/responsible-disclosure
Source: cybersecurity@se.com
Resource:
Third Party Advisory
Hyperlink: https://www.schneider-electric.com/en/download/document/SEVD-2019-134-06/
Source: cybersecurity@se.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

0Records found

Details not found