A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a device to be compromised when it is first configured.
A security misconfiguration vulnerability exists in Schneider Electric's IGSS Mobile application versions 3.01 and prior in which a lack of certificate pinning during the TLS/SSL connection establishing process can result in a man-in-the-middle attack.
A CWE-521: Weak Password Requirements vulnerability exists in the GP-Pro EX V1.00 to V4.09.100 which could cause the discovery of the password when the user is entering the password because it is not masqueraded.
A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA database server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in a function that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause path traversal attacks. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could result in information disclosure when opening a malicious solution file provided by an attacker with SCADAPack Workbench. This could be exploited to pass data from local files to a remote system controlled by an attacker. Affected Product: SCADAPack Workbench (6.6.8a and prior)
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause unauthenticated code execution. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)
A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA web server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device.
Vulnerability in the Java SE, Java SE Embedded component of Oracle Java SE (subcomponent: JGSS). Supported versions that are affected are Java SE: 7u161, 8u152 and 9.0.1; Java SE Embedded: 8u151. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Java SE, Java SE Embedded. While the vulnerability is in Java SE, Java SE Embedded, attacks may significantly impact additional products. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Java SE, Java SE Embedded accessible data. Note: This vulnerability applies to Java deployments, typically in clients running sandboxed Java Web Start applications or sandboxed Java applets, that load and run untrusted code (e.g., code that comes from the internet) and rely on the Java sandbox for security. This vulnerability does not apply to Java deployments, typically in servers, that load and run only trusted code (e.g., code installed by an administrator). CVSS 3.0 Base Score 6.8 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N).
Stack-based buffer overflow in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allows remote attackers to execute arbitrary code via unspecified vectors.
Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allow remote attackers to execute arbitrary code or cause a denial of service (out-of-bounds read) via unspecified vectors.
Vulnerability in the Java SE, Java SE Embedded, JRockit component of Oracle Java SE (subcomponent: JCE). Supported versions that are affected are Java SE: 6u171, 7u161, 8u152 and 9.0.1; Java SE Embedded: 8u151; JRockit: R28.3.16. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Java SE, Java SE Embedded, JRockit. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Java SE, Java SE Embedded, JRockit accessible data. Note: This vulnerability applies to client and server deployment of Java. This vulnerability can be exploited through sandboxed Java Web Start applications and sandboxed Java applets. It can also be exploited by supplying data to APIs in the specified Component without using sandboxed Java Web Start applications or sandboxed Java applets, such as through a web service. CVSS 3.0 Base Score 5.9 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N).
The vulnerability exists within runscript.php applet in Schneider Electric U.motion Builder software versions prior to v1.3.4. There is a directory traversal vulnerability in the processing of the 's' parameter of the applet.
The vulnerability exists within processing of sendmail.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The applet allows callers to select arbitrary files to send to an arbitrary email address.
The vulnerability exists within error.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. System information is returned to the attacker that contains sensitive data.
The vulnerability exists within css.inc.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The 'css' parameter contains a directory traversal vulnerability.
Vulnerability in the Java SE, Java SE Embedded, JRockit component of Oracle Java SE (subcomponent: Libraries). Supported versions that are affected are Java SE: 6u171, 7u161, 8u152 and 9.0.1; Java SE Embedded: 8u151; JRockit: R28.3.16. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Java SE, Java SE Embedded, JRockit. Successful attacks of this vulnerability can result in unauthorized read access to a subset of Java SE, Java SE Embedded, JRockit accessible data. Note: This vulnerability applies to client and server deployment of Java. This vulnerability can be exploited through sandboxed Java Web Start applications and sandboxed Java applets. It can also be exploited by supplying data to APIs in the specified Component without using sandboxed Java Web Start applications or sandboxed Java applets, such as through a web service. CVSS 3.0 Base Score 3.7 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N).
A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts Telnet network traffic between a user and the device.
A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts HTTP network traffic between a user and the device.
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers.
**VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability could cause certain data to be visible on the network when the 'password' feature is enabled. This vulnerability was discovered in and remediated in versions v4.9.1 and v4.10.1 on May 30, 2013. The 'password' feature is an additional optional check performed by TS1131 that it is connected to a specific controller. This data is sent as clear text and is visible on the network. This feature is not present in TriStation 1131 versions v4.9.1 and v4.10.1 through current. Therefore, the vulnerability is not present in these versions.
ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated attacker to upload, read, and delete files.
Schneider Electric Ampla MES 6.4 provides capability to interact with data from third party databases. When connectivity to those databases is configured to use a SQL user name and password, an attacker may be able to sniff details from the connection string. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible.
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol.
A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or modification of data if an attacker is able to intercept network traffic.
A cleartext transmission of sensitive information vulnerability exists in Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. he integrated web server (Port 80/443/TCP) of the affected devices could allow remote attackers to discover an administrative account. If default on device, it is not using a SSL in settings and if multiple request of the page "Access Control" (IP-address device/ups/pas_cont.htm) account data will be sent in cleartext
UCWeb UC Browser 7.0.185.1002 on Windows uses HTTP for downloading certain PDF modules, which allows MITM attacks.
An issue was discovered in the MensaMax (aka com.breustedt.mensamax) application 4.3 for Android. Cleartext Transmission of Sensitive Information allows man-in-the-middle attackers to eavesdrop authentication information between the application and the server.
The IIOP OpenJDK Subsystem in WildFly before version 14.0.0 does not honour configuration when SSL transport is required. Servers before this version that are configured with the following setting allow clients to create plaintext connections: <transport-config confidentiality="required" trust-in-target="supported"/>
IBM i2 Enterprise Insight Analysis 2.1.7 could allow a remote attacker to obtain sensitive information, caused by the failure to properly enable HTTP Strict Transport Security. An attacker could exploit this vulnerability to obtain sensitive information using man in the middle techniques. IBM X-Force ID: 142117.
IBM InfoSphere Information Server 11.3, 11.5, and 11.7 could allow a remote attacker to obtain sensitive information, caused by the failure to properly enable HTTP Strict Transport Security. An attacker could exploit this vulnerability to obtain sensitive information using man in the middle techniques. IBM X-Force ID: 140089.
IBM Cloud Pak for Security (CP4S) 1.4.0.0, 1.5.0.0, 1.5.0.1, 1.6.0.0, and 1.6.0.1 could allow a remote attacker to obtain sensitive information, caused by the failure to properly enable HTTP Strict Transport Security. An attacker could exploit this vulnerability to obtain sensitive information using man in the middle techniques. IBM X-Force ID: 199235.
The Taidii Diibear Android application 2.4.0 and all its derivatives allow attackers to view private chat messages and media files via logcat because of excessive logging.
Quick Heal Total Security before version 19.0 transmits quarantine and sysinfo files via clear text.
CS2 Network P2P through 3.x, as used in millions of Internet of Things devices, suffers from an information exposure flaw that exposes user session data to supernodes in the network, as demonstrated by passively eavesdropping on user video/audio streams, capturing credentials, and compromising devices.
When an SRX Series device is configured to use HTTP/HTTPS pass-through authentication services, a client sending authentication credentials in the initial HTTP/HTTPS session is at risk that these credentials may be captured during follow-on HTTP/HTTPS requests by a malicious actor through a man-in-the-middle attack or by authentic servers subverted by malicious actors. FTP, and Telnet pass-through authentication services are not affected. Affected releases are Juniper Networks SRX Series: 12.1X46 versions prior to 12.1X46-D67 on SRX Series; 12.3X48 versions prior to 12.3X48-D25 on SRX Series; 15.1X49 versions prior to 15.1X49-D35 on SRX Series.
This affects all versions of package com.mintegral.msdk:alphab. The Android SDK distributed by the company contains malicious functionality in this module that tracks: 1. Downloads from Google urls either within Google apps or via browser including file downloads, e-mail attachments and Google Docs links. 2. All apk downloads, either organic or not. Mintegral listens to download events in Android's download manager and detects if the downloaded file's url contains: a. google.com or comes from a Google app (the com.android.vending package) b. Ends with .apk for apk downloads In both cases, the module sends the captured data back to Mintegral's servers. Note that the malicious functionality keeps running even if the app is currently not in focus (running in the background).
Cleartext Transmission of Sensitive Information in RDT400 in SICK APU allows an unprivileged remote attacker to retrieve potentially sensitive information via intercepting network traffic that is not encrypted.
Delta Controls enteliTOUCH 3.40.3935, 3.40.3706, and 3.33.4005 was discovered to transmit and store sensitive information in cleartext. This vulnerability allows attackers to intercept HTTP Cookie authentication credentials via a man-in-the-middle attack.
On BIG-IP ASM 11.6.1-11.6.5.1, under certain configurations, the BIG-IP system sends data plane traffic to back-end servers unencrypted, even when a Server SSL profile is applied.
IBM Security Guardium Insights 2.0.2 does not set the secure attribute on authorization tokens or session cookies. Attackers may be able to get the cookie values by sending a http:// link to a user or by planting this link in a site the user goes to. The cookie will be sent to the insecure link and the attacker can then obtain the cookie value by snooping the traffic. IBM X-Force ID: 184822.
IBM Security Identity Governance and Intelligence 5.2.6 could allow a remote attacker to obtain sensitive information, caused by the failure to properly enable HTTP Strict Transport Security. An attacker could exploit this vulnerability to obtain sensitive information using man in the middle techniques.
IBM Verify Gateway (IVG) 1.0.0 and 1.0.1 transmits sensitive information in plain text which could be obtained by an attacker using man in the middle techniques. IBM X-Force ID: 179428.
IBM Security Identity Governance and Intelligence 5.2.4, 5.2.5, and 5.2.6 could allow a remote attacker to obtain sensitive information, caused by the failure to properly enable HTTP Strict Transport Security. An attacker could exploit this vulnerability to obtain sensitive information using man in the middle techniques. IBM X-Force ID: 192429.
IBM Emptoris Strategic Supply Management 10.1.0, 10.1.1, and 10.1.3 transmits sensitive information in HTTP GET request parameters. This may lead to information disclosure via man in the middle methods. IBM X-Force ID: 190984.
Dahua DHI-HCVR7216A-S3 devices with NVR Firmware 3.210.0001.10 2016-06-06, Camera Firmware 2.400.0000.28.R 2016-03-29, and SmartPSS Software 1.16.1 2017-01-19 send cleartext passwords in response to requests from the Web Page, Mobile Application, and Desktop Application interfaces, which allows remote attackers to obtain sensitive information by sniffing the network, a different vulnerability than CVE-2013-6117.
LRM version 2.4 and lower does not implement TLS encryption. A malicious actor can MITM attack sensitive data in-transit, including credentials.
IBM QRadar Network Security 5.4.0 and 5.5.0 transmits sensitive or security-critical data in cleartext in a communication channel that can be obtained using man in the middle techniques. IBM X-Force ID: 17467.