Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2019-6989

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-06 Jun, 2019 | 17:24
Updated At-04 Aug, 2024 | 20:38
Rejected At-
Credits

TP-Link TL-WR940N is vulnerable to a stack-based buffer overflow, caused by improper bounds checking by the ipAddrDispose function. By sending specially crafted ICMP echo request packets, a remote authenticated attacker could overflow a buffer and execute arbitrary code on the system with elevated privileges.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:06 Jun, 2019 | 17:24
Updated At:04 Aug, 2024 | 20:38
Rejected At:
▼CVE Numbering Authority (CNA)

TP-Link TL-WR940N is vulnerable to a stack-based buffer overflow, caused by improper bounds checking by the ipAddrDispose function. By sending specially crafted ICMP echo request packets, a remote authenticated attacker could overflow a buffer and execute arbitrary code on the system with elevated privileges.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.exploit-db.com/exploits/46678/
exploit
x_refsource_EXPLOIT-DB
http://packetstormsecurity.com/files/152458/TP-LINK-TL-WR940N-TL-WR941ND-Buffer-Overflow.html
x_refsource_MISC
Hyperlink: https://www.exploit-db.com/exploits/46678/
Resource:
exploit
x_refsource_EXPLOIT-DB
Hyperlink: http://packetstormsecurity.com/files/152458/TP-LINK-TL-WR940N-TL-WR941ND-Buffer-Overflow.html
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.exploit-db.com/exploits/46678/
exploit
x_refsource_EXPLOIT-DB
x_transferred
http://packetstormsecurity.com/files/152458/TP-LINK-TL-WR940N-TL-WR941ND-Buffer-Overflow.html
x_refsource_MISC
x_transferred
Hyperlink: https://www.exploit-db.com/exploits/46678/
Resource:
exploit
x_refsource_EXPLOIT-DB
x_transferred
Hyperlink: http://packetstormsecurity.com/files/152458/TP-LINK-TL-WR940N-TL-WR941ND-Buffer-Overflow.html
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:06 Jun, 2019 | 18:29
Updated At:24 Aug, 2020 | 17:37

TP-Link TL-WR940N is vulnerable to a stack-based buffer overflow, caused by improper bounds checking by the ipAddrDispose function. By sending specially crafted ICMP echo request packets, a remote authenticated attacker could overflow a buffer and execute arbitrary code on the system with elevated privileges.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.08.8HIGH
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary2.09.0HIGH
AV:N/AC:L/Au:S/C:C/I:C/A:C
Type: Primary
Version: 3.0
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 9.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
CPE Matches

TP-Link Systems Inc.
tp-link
>>tl-wr940n_firmware>>-
cpe:2.3:o:tp-link:tl-wr940n_firmware:-:*:*:*:*:*:*:*
TP-Link Systems Inc.
tp-link
>>tl-wr940n>>-
cpe:2.3:h:tp-link:tl-wr940n:-:*:*:*:*:*:*:*
TP-Link Systems Inc.
tp-link
>>tl-wr941nd_firmware>>-
cpe:2.3:o:tp-link:tl-wr941nd_firmware:-:*:*:*:*:*:*:*
TP-Link Systems Inc.
tp-link
>>tl-wr941nd>>-
cpe:2.3:h:tp-link:tl-wr941nd:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-787Primarynvd@nist.gov
CWE ID: CWE-787
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
http://packetstormsecurity.com/files/152458/TP-LINK-TL-WR940N-TL-WR941ND-Buffer-Overflow.htmlcve@mitre.org
N/A
https://www.exploit-db.com/exploits/46678/cve@mitre.org
N/A
Hyperlink: http://packetstormsecurity.com/files/152458/TP-LINK-TL-WR940N-TL-WR941ND-Buffer-Overflow.html
Source: cve@mitre.org
Resource: N/A
Hyperlink: https://www.exploit-db.com/exploits/46678/
Source: cve@mitre.org
Resource: N/A

Change History

0
Information is not available yet

Similar CVEs

427Records found

CVE-2025-8184
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.08% / 24.39%
||
7 Day CHG+0.01%
Published-26 Jul, 2025 | 09:02
Updated-31 Jul, 2025 | 17:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-513 HTTP POST Request formSetWanL2TPtriggers formSetWanL2TPcallback stack-based overflow

A vulnerability was found in D-Link DIR-513 up to 1.10 and classified as critical. This issue affects the function formSetWanL2TPcallback of the file /goform/formSetWanL2TPtriggers of the component HTTP POST Request Handler. The manipulation leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-513dir-513_firmwareDIR-513
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-8243
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.38% / 58.70%
||
7 Day CHG+0.05%
Published-27 Jul, 2025 | 21:32
Updated-29 Jul, 2025 | 21:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X15 HTTP POST Request formMapDel buffer overflow

A vulnerability was found in TOTOLINK X15 1.0.0-B20230714.1105 and classified as critical. This issue affects some unknown processing of the file /boafrm/formMapDel of the component HTTP POST Request Handler. The manipulation of the argument devicemac1 leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-x15_firmwarex15X15
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-15992
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.2||HIGH
EPSS-5.77% / 90.14%
||
7 Day CHG~0.00%
Published-23 Sep, 2020 | 00:27
Updated-26 Nov, 2024 | 16:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Adaptive Security Appliance Software and Firepower Threat Defense Software Remote Code Execution Vulnerability

A vulnerability in the implementation of the Lua interpreter integrated in Cisco Adaptive Security Appliance (ASA) Software and Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, remote attacker to execute arbitrary code with root privileges on the underlying Linux operating system of an affected device. The vulnerability is due to insufficient restrictions on the allowed Lua function calls within the context of user-supplied Lua scripts. A successful exploit could allow the attacker to trigger a heap overflow condition and execute arbitrary code with root privileges on the underlying Linux operating system of an affected device.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-secure_firewall_management_centeradaptive_security_appliancefirepower_threat_defenseadaptive_security_appliance_softwareCisco Adaptive Security Appliance (ASA) Software
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-15665
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-1.25% / 78.49%
||
7 Day CHG~0.00%
Published-20 Mar, 2020 | 17:18
Updated-05 Aug, 2024 | 00:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Rivet Killer Control Center before 2.1.1352. IOCTL 0x120004 in KfeCo10X64.sys fails to validate an offset passed as a parameter during a memory operation, leading to an arbitrary write primitive that can lead to code execution or escalation of privileges.

Action-Not Available
Vendor-killernetworkingn/a
Product-killer_control_centern/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-34770
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-10||CRITICAL
EPSS-1.06% / 76.72%
||
7 Day CHG~0.00%
Published-23 Sep, 2021 | 02:27
Updated-07 Nov, 2024 | 21:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco IOS XE Software for Catalyst 9000 Family Wireless Controllers CAPWAP Remote Code Execution Vulnerability

A vulnerability in the Control and Provisioning of Wireless Access Points (CAPWAP) protocol processing of Cisco IOS XE Software for Cisco Catalyst 9000 Family Wireless Controllers could allow an unauthenticated, remote attacker to execute arbitrary code with administrative privileges or cause a denial of service (DoS) condition on an affected device. The vulnerability is due to a logic error that occurs during the validation of CAPWAP packets. An attacker could exploit this vulnerability by sending a crafted CAPWAP packet to an affected device. A successful exploit could allow the attacker to execute arbitrary code with administrative privileges or cause the affected device to crash and reload, resulting in a DoS condition.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-ios_xecatalyst_9800-lcatalyst_9800-40_wireless_controllercatalyst_9800-40catalyst_9800-l-ccatalyst_9800-80_wireless_controllercatalyst_9800_embedded_wireless_controllercatalyst_9800catalyst_9800-clcatalyst_9800-80catalyst_9800-l-fCisco IOS XE Software
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-9088
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.08% / 25.14%
||
7 Day CHG~0.00%
Published-16 Aug, 2025 | 23:02
Updated-21 Aug, 2025 | 16:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 formSetVirtualSer save_virtualser_data stack-based overflow

A vulnerability was found in Tenda AC20 16.03.08.12. This vulnerability affects the function save_virtualser_data of the file /goform/formSetVirtualSer. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20ac20_firmwareAC20
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-8169
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.08% / 24.20%
||
7 Day CHG+0.01%
Published-25 Jul, 2025 | 20:32
Updated-31 Jul, 2025 | 17:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-513 HTTP POST Request formSetWanPPTPpath formSetWanPPTPcallback buffer overflow

A vulnerability classified as critical has been found in D-Link DIR-513 1.10. This affects the function formSetWanPPTPcallback of the file /goform/formSetWanPPTPpath of the component HTTP POST Request Handler. The manipulation of the argument curTime leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-513dir-513_firmwareDIR-513
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-13280
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.49% / 84.72%
||
7 Day CHG~0.00%
Published-09 Jul, 2019 | 18:44
Updated-04 Aug, 2024 | 23:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TRENDnet TEW-827DRU with firmware up to and including 2.04B03 contains a stack-based buffer overflow while returning an error message to the user about failure to resolve a hostname during a ping or traceroute attempt. This allows an authenticated user to execute arbitrary code. The exploit can be exercised on the local intranet or remotely if remote administration is enabled.

Action-Not Available
Vendor-n/aTRENDnet, Inc.
Product-tew-827dru_firmwaretew-827drun/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-13193
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.20% / 83.78%
||
7 Day CHG~0.00%
Published-13 Mar, 2020 | 18:40
Updated-04 Aug, 2024 | 23:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Some Brother printers (such as the HL-L8360CDW v1.20) were affected by a stack buffer overflow vulnerability as the web server did not parse the cookie value properly. This would allow an attacker to execute arbitrary code on the device.

Action-Not Available
Vendor-n/aBrother Industries, Ltd.
Product-mfc-j895dwmfc-l6900dwhl-l6450dwhl-l6400dwtads-2800wdcp-1617nwmfc-l2720dn\(jpn\)mfc-j497dwdcp-t710w\(chn\)_firmwaremfc-j1500n\(jpn\)mfc-j5335dwmfc-l2740dwr_firmwaremfc-l2750dw_firmwaremfc-l3770cdw_firmwaredcp-7195dw_firmwaremfc-l2705dwmfc-j893n_firmwaredcp-1623wr_firmwaremfc-l6900dwx_firmwaredcp-l8410cdw_firmwaremfc-9350cdwmfc-j998dn_firmwarehl-l8260cdndcp-l2560dwrdcp-j982n-bmfc-l5702dw_firmwarehl-l2370dnhl-l2350dw_firmwaremfc-j893nmfc-l2720dw_firmwaremfc-l9570cdw_firmwarehl-l3230cdwhl-b2050dnhl-1211w_firmwaredcp-j572dwdcp-j577ndcp-j973n-wmfc-l2720dwr_firmwaredcp-l2531dw_firmwaremfc-j998dwn_firmwaredcp-l2520dw_firmwaremfc-l2707dwmfc-l9570cdwdcp-j978n-b_firmwaredcp-t710w_firmwaredcp-l2540dw\(jpn\)dcp-1610wvbmfc-l5802dwmfc-9350cdw_firmwaremfc-8530dnmfc-l2705dw_firmwaremfc-1910wmfc-1916nwmfc-j1300dwmfc-l2712dn_firmwaremfc-l3730cdn_firmwaremfc-j995dwmfc-9150cdndcp-l3551cdw_firmwarehl-l8360cdwtmfc-1911wdcp-l6600dwdcp-l2541dw_firmwaremfc-j805dw_xl_firmwaremfc-j6535dwmfc-l2701dwdcp-j982n-w_firmwaredcp-b7535dwmfc-j6947dw_firmwaremfc-l5700dw_firmwaredcp-l5500dnhl-1210wvb_firmwarehl-l9310cdwmfc-l2717dw_firmwarehl-l2395dw_firmwaremfc-l8610cdwmfc-j5730dw_firmwaremfc-l8900cdwmfc-l2685dw_firmwarehl-l6200dwt_firmwaredcp-j772dwhl-l2370dn_firmwaremfc-l2712dwdcp-1610wvb_firmwarehl-j6000cdw\(jpn\)_firmwarehl-l8360cdwt_firmwareads-3000nmfc-j5845dw_xl_firmwaredcp-j978n-w_firmwaredcp-1610wemfc-l8900cdw_firmwaredcp-l2540dnhl-l8360cdw_firmwaremfc-j805dw_firmwaredcp-b7530dndcp-l5650dnmfc-t810w\(chn\)dcp-l8410cdwdcp-1616nwmfc-8540dn_firmwaremfc-l2710dw_firmwaremfc-l5802dw_firmwarehl-l2375dw_firmwarehl-1210wvbmfc-l2713dw_firmwaremfc-l5902dwdcp-l5502dnhl-l2366dw_firmwarehl-1210wr_firmwarehl-l3270cdwdcp-l5600dn_firmwareads-2400n_firmwaremfc-l2720dwrhl-l2375dwhl-l5202dw_firmwaredcp-1610we_firmwaremfc-l2700dw\(oce\)_firmwaremfc-j995dw_xlhl-l8360cdwmfc-j491dwhl-l2385dwmfc-1912wrmfc-l2750dw\(jpn\)_firmwarehl-l6200dwtdcp-1610wrdcp-l3510cdwmfc-l2740dw_firmwarehl-1223we_firmwaremfc-j3530dwads-2800w_firmwaremfc-j6930dw_firmwaremfc-l6702dw_firmwaremfc-l2715dw\(twn\)hl-l5100dnthl-1210w_firmwaremfc-j1500n\(jpn\)_firmwarehl-b2050dn_firmwaredcp-l3550cdw_firmwaremfc-t910dw_firmwaredcp-l2532dw_firmwaremfc-l8610cdw\(jpn\)_firmwaredcp-b7530dn_firmwaremfc-l5755dw_firmwaremfc-l2700dwmfc-l6900dw_firmwaremfc-l5900dw_firmwaredcp-l5652dndcp-l2520dwmfc-l2700dw\(oce\)mfc-l2700dw_firmwarehl-1218whl-l3210cwdcp-l2520dwr_firmwaremfc-j6730dw_firmwarefax-l2700dn\(jpn\)mfc-l2717dwdcp-1618w_firmwaredcp-l2550dn_firmwaredcp-l2541dwhl-l2365dwrmfc-j6530dwdcp-1615nwdcp-7180dn_firmwaremfc-l5850dw_firmwaremfc-l6950dw_firmwarehl-b2080dwmfc-l2680whl-l2360dw_firmwareads-3600w_firmwarefax-l2710dn\(jpn\)_firmwaremfc-j5330dwmfc-l5800dw_firmwarehl-l3290cdwmfc-l2750dwxl_firmwaredcp-1615nw_firmwaremfc-j5335dw_firmwaremfc-l6950dwhl-l8260cdn_firmwaremfc-l2730dwhl-l6400dwxhl-l6250dw_firmwaredcp-1617nw_firmwarehl-l2340dwrmfc-7895dw_firmwaremfc-l2740dw\(jpn\)mfc-1911nw_firmwarehl-l6300dw_firmwaredcp-l3550cdwhl-l2305w_firmwaredcp-1612wemfc-l5700dwmfc-j6535dw_firmwaredcp-j774dwhl-l6200dwmfc-j998dwndcp-j572n_firmwaredcp-l2550dwmfc-l6902dwmfc-7880dn_firmwaremfc-j5845dw_firmwaremfc-j890dw_firmwaremfc-j5330dw_firmwaremfc-j738dwn_firmwarehl-l2380dwmfc-l6750dw_firmwaremfc-l9570cdw\(jpn\)_firmwaredcp-1612wvbdcp-l2540dw_firmwaremfc-l2770dw_firmwarehl-l2395dwdcp-l2551dndcp-l2532dwdcp-l3551cdwmfc-l6900dw\(jpn\)mfc-l3730cdnhl-l3210cw_firmwaredcp-j988n\(jpn\)mfc-l2740dw\(jpn\)_firmwaremfc-j903nmfc-l6900dw\(jpn\)_firmwaremfc-l5750dwdcp-l3517cdwmfc-1911w_firmwaremfc-j497dw_firmwarehl-j6000dwhl-j6000dw_firmwaremfc-l6902dw_firmwaremfc-j995dw_firmwaremfc-j6945dwmfc-j5630cdwhl-1212wr_firmwaremfc-l2740dwrmfc-t910dwmfc-j6947dwmfc-l2712dnmfc-j6935dw_firmwaremfc-l2713dwmfc-l6702dwmfc-l3735cdnmfc-l5755dw\(jpn\)_firmwarehl-3190cdw_firmwaremfc-j6530dw_firmwarehl-l2361dnmfc-j5845dwhl-l2366dwdcp-j774dw_firmwaremfc-j6997cdw\(jpn\)_firmwaremfc-j6999cdw\(jpn\)hl-l6202dw_firmwaremfc-8540dnhl-l8260cdw_firmwaremfc-t4500dwmfc-j738dnmfc-l2700dwr_firmwaredcp-b7520dwmfc-j5930dw_firmwarehl-3160cdw_firmwarehl-l6200dw_firmwaremfc-l2720dwdcp-7180dnmfc-j2330dwhl-5590dnmfc-l8610cdw_firmwaremfc-j690dwmfc-l6900dwgmfc-l2716dwhl-l5200dw_firmwaremfc-9150cdn_firmwaremfc-l2710dnmfc-7880dnhl-l6400dwgmfc-l2771dw_firmwarehl-1223wedcp-l5650dn_firmwaremfc-1919nw_firmwareads-3000n_firmwaremfc-l6700dw_firmwaredcp-9030cdn_firmwaredcp-l2520dwrdcp-j972nmfc-j6999cdw\(jpn\)_firmwaredcp-1612we_firmwaredcp-j973n-b_firmwaremfc-j6980cdw\(jpn\)_firmwaremfc-j898nmfc-j6545dw_firmwaremfc-l2750dw\(jpn\)dcp-l2530dw_firmwaremfc-1910wedcp-l5500dn_firmwaremfc-j805dwmfc-j895dw_firmwarehl-1222wemfc-j898n_firmwaredcp-l2540dnr_firmwarehl-l3230cdnhl-1218w_firmwaredcp-7195dwhl-l6250dn_firmwaredcp-l2551dwhl-l2340dwr_firmwaremfc-1911nwads-3600whl-l2360dnrdcp-l2560dw_firmwaremfc-j1300dw_firmwaremfc-l2710dwhl-2560dndcp-j981n_firmwaremfc-b7715dw_firmwaremfc-l3710cw_firmwarehl-l6402dw_firmwaredcp-l2551dw_firmwaremfc-l2712dw_firmwaremfc-j995dw_xl_firmwaredcp-l2537dw_firmwaremfc-l2732dwmfc-l2750dwhl-l2315dwmfc-l2685dwmfc-l5702dwdcp-l2537dwmfc-j903n_firmwaredcp-1612wvb_firmwaremfc-1912wr_firmwaremfc-l6800dwdcp-l2535dwdcp-l2550dw_firmwarehl-l2352dw_firmwaredcp-j582n_firmwaredcp-l5602dn_firmwaremfc-t4500dw_firmwarehl-2595dw_firmwaremfc-t810whl-l2340dwmfc-j2330dw_firmwarehl-1222we_firmwaremfc-j6580cdw\(jpn\)dcp-1612wr_firmwarehl-l5100dn_firmwaremfc-j5730dwmfc-l6700dwdcp-t510wmfc-j6983cdwhl-l2365dwdcp-j982n-b_firmwaremfc-l6750dwdcp-j978n-wmfc-j6583cdwdcp-l2550dndcp-l2560dwr_firmwaredcp-j988n\(jpn\)_firmwarehl-l2386dw_firmwaremfc-b7720dnhl-l2372dnmfc-l3735cdn_firmwarehl-3160cdwmfc-l6800dw_firmwarehl-l3230cdn_firmwarehl-l2376dwhl-t4000dw_firmwaremfc-l2701dw_firmwaredcp-b7535dw_firmwaredcp-l6600dw_firmwaremfc-1915w_firmwaremfc-l2680w_firmwaremfc-l2732dw_firmwarehl-1212w_firmwaredcp-l2531dwdcp-t510w\(chn\)dcp-l2530dwmfc-j738dwnmfc-j6545dw_xl_firmwaremfc-l6970dwmfc-j738dn_firmwaredcp-j972n_firmwaredcp-1618wdcp-j772dw_firmwaredcp-t510w_firmwaremfc-l5902dw_firmwaremfc-l2716dw_firmwaremfc-l5800dwmfc-j815dw_xlmfc-j5630cdw_firmwaredcp-l3517cdw_firmwaredcp-j973n-bmfc-l3770cdwdcp-l5602dnmfc-l5750dw_firmwarehl-1212wvbmfc-l2730dw_firmwaredcp-j982n-wmfc-j5930dwfax-l2700dn\(jpn\)_firmwarehl-l2361dn_firmwarehl-l6400dwg_firmwaremfc-l9577cdwdcp-1612wrmfc-j805dw_xlmfc-l2720dn\(jpn\)_firmwaremfc-j6995cdw\(jpn\)_firmwaremfc-j6583cdw_firmwaremfc-j1605dn_firmwarehl-l6400dwdcp-l2535dw_firmwarehl-l6300dwdcp-1610wr_firmwaremfc-j491dw_firmwarehl-l5202dwdcp-j1100dwmfc-j6545dwdcp-l5600dndcp-j978n-bdcp-l3510cdw_firmwaremfc-l2703dw_firmwaremfc-l2730dn\(jpn\)hl-l5100dnmfc-j3930dwmfc-j3930dw_firmwaremfc-j6995cdw\(jpn\)mfc-j5830dwdcp-l2552dnmfc-j5945dw_firmwarehl-l2350dwhl-l3230cdw_firmwaredcp-l2540dwdcp-l2551dn_firmwaremfc-l5755dwmfc-j6930dwhl-l2340dw_firmwaredcp-1610w_firmwaredcp-l2560dwhl-l2365dw_firmwaremfc-j998dnhl-l6300dwt_firmwaremfc-l5850dwhl-j6100dwmfc-j6545dw_xldcp-j572nmfc-l3745cdw_firmwarehl-l2376dw_firmwaremfc-j5845dw_xldcp-1616nw_firmwarehl-l2360dnhl-l5200dwtmfc-l8610cdw\(jpn\)hl-l5595dnhl-t4000dwhl-l2371dnhl-l5200dwt_firmwarehl-l6402dwmfc-b7715dwdcp-1623wrhl-1212we_firmwaremfc-1916nw_firmwaredcp-t710wmfc-j6980cdw\(jpn\)hl-l2315dw_firmwaredcp-l2540dw\(jpn\)_firmwarehl-l5595dn_firmwarehl-l9310cdw_firmwarehl-l5102dwmfc-b7720dn_firmwarehl-l2365dwr_firmwaremfc-l3710cwhl-l6202dwmfc-l5700dnhl-l2370dw_firmwaremfc-l2770dwmfc-j6945dw_firmwarehl-1210wrmfc-l2750dwxlmfc-l5900dwhl-l2370dwdcp-1610whl-l5102dw_firmwaremfc-j2730dw_firmwarehl-1210wehl-l2305wdcp-l2540dn_firmwarehl-2560dn_firmwaredcp-l2550dw\(jpn\)_firmwarehl-j6100dw_firmwaremfc-j3530dw_firmwaremfc-j5830dw_firmwarehl-l2385dw_firmwarehl-l5200dwdcp-b7520dw_firmwaredcp-1612wmfc-j6983cdw_firmwaredcp-j582nhl-1210whl-l2386dwhl-1210we_firmwaremfc-j890dwmfc-j5945dwfax-l2710dn\(jpn\)mfc-1910w_firmwaremfc-j2730dwmfc-1910we_firmwarehl-l2371dn_firmwarehl-l2360dn_firmwaremfc-l2752dw_firmwarehl-l2351dw_firmwarehl-l2370dwxlmfc-l2751dwmfc-j1605dnhl-l6450dw_firmwaredcp-j973n-w_firmwaremfc-j6580cdw\(jpn\)_firmwaremfc-l2710dn_firmwarehl-1212wvb_firmwarehl-l2357dw_firmwaremfc-l6900dwg_firmwaremfc-l2703dwhl-l6400dwx_firmwarehl-l5100dnt_firmwarehl-3190cdwhl-l6400dwt_firmwaremfc-1915wmfc-l8690cdw_firmwaremfc-l3750cdw_firmwaremfc-l2730dn\(jpn\)_firmwaredcp-9030cdnmfc-l9577cdw_firmwarehl-l2390dw_firmwaremfc-l3750cdwhl-1212wdcp-t510w\(chn\)_firmwaremfc-t810w\(chn\)_firmwaremfc-8535dn_firmwaremfc-1919nwmfc-t810w_firmwarehl-l2370dwxl_firmwarehl-l8260cdwhl-j6000cdw\(jpn\)mfc-l2700dndcp-l2552dn_firmwaremfc-l2700dn_firmwaredcp-l5652dn_firmwaremfc-l2771dwdcp-1612w_firmwaremfc-l6970dw_firmwarehl-1211wmfc-l3745cdwmfc-l2707dw_firmwaremfc-l8690cdwdcp-l2540dnrdcp-j577n_firmwaredcp-j1100dw_firmwarehl-l6400dw_firmwaredcp-t710w\(chn\)dcp-j572dw_firmwarehl-2595dwhl-l2360dnr_firmwarehl-l2351dwmfc-l2715dw_firmwaremfc-j6730dwhl-5590dn_firmwaremfc-8535dnmfc-l5700dn_firmwareads-2400ndcp-1622wemfc-l9570cdw\(jpn\)mfc-l2740dwmfc-j815dw_xl_firmwarehl-b2080dw_firmwaremfc-l2700dnrmfc-l2751dw_firmwaremfc-j6997cdw\(jpn\)hl-l2372dn_firmwarehl-1212wemfc-l2700dnr_firmwaredcp-1622we_firmwaremfc-j6935dwdcp-l2550dw\(jpn\)mfc-l2715dwmfc-l2752dwdcp-j981ndcp-1623wemfc-8530dn_firmwarehl-l6250dwmfc-7895dwmfc-j690dw_firmwaredcp-l5502dn_firmwarehl-l6300dwtmfc-l2700dwrdcp-1623we_firmwarehl-l3290cdw_firmwaremfc-l5755dw\(jpn\)hl-l6250dnhl-l2352dwhl-l2360dwhl-l2380dw_firmwaremfc-l2715dw\(twn\)_firmwaremfc-l6900dwxhl-l2390dwhl-l2357dwhl-l3270cdw_firmwarehl-1212wrn/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-12325
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.2||HIGH
EPSS-1.92% / 82.59%
||
7 Day CHG~0.00%
Published-22 Jul, 2019 | 15:54
Updated-04 Aug, 2024 | 23:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Htek UC902 VoIP phone web management interface contains several buffer overflow vulnerabilities in the firmware version 2.0.4.4.46, which allow an attacker to crash the device (DoS) without authentication or execute code (authenticated as a user) to spawn a remote shell as a root user.

Action-Not Available
Vendor-htekn/a
Product-uc902_firmwareuc902n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3011
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.42% / 60.92%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 00:00
Updated-15 Jan, 2025 | 18:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258297 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2990
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.98%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 18:31
Updated-15 Jan, 2025 | 18:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 execCommand formexeCommand stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda FH1203 2.0.1.6. This affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258159. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3010
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.55% / 66.98%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 23:31
Updated-15 Jan, 2025 | 18:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda FH1205 2.0.0.7(775) and classified as critical. Affected by this issue is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258296. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3007
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.45% / 62.71%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 23:00
Updated-15 Jan, 2025 | 18:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 NatStaticSetting fromNatStaticSetting stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda FH1205 2.0.0.7(775). This issue affects the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258293 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2992
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.86% / 74.14%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 19:00
Updated-22 Jan, 2025 | 17:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda FH1203 2.0.1.6 and classified as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258161 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203_firmwarefh1203FH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2903
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.01% / 76.22%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 20:31
Updated-22 Jan, 2025 | 17:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 GetParentControlInfo stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2902
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.68% / 70.73%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 20:00
Updated-22 Jan, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WifiGuestSet fromSetWifiGusetBasic stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2986
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.13%
||
7 Day CHG-0.06%
Published-27 Mar, 2024 | 16:31
Updated-14 Jan, 2025 | 15:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 SetSpeedWan formSetSpeedWan stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258155. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-33217
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.48% / 63.97%
||
7 Day CHG~0.00%
Published-07 Jul, 2021 | 14:07
Updated-03 Aug, 2024 | 23:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. The Web Application allows Arbitrary Read/Write actions by authenticated users. The API allows an HTTP POST of arbitrary content into any file on the filesystem as root.

Action-Not Available
Vendor-commscopen/a
Product-ruckus_iot_controllern/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2976
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.00% / 76.11%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 13:31
Updated-15 Jan, 2025 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 execCommand R7WebsSecurityHandler stack-based overflow

A vulnerability was found in Tenda F1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203f1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2978
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.13%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 14:00
Updated-10 Apr, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 setcfm formSetCfm stack-based overflow

A vulnerability classified as critical has been found in Tenda F1203 2.0.1.6. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258147. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203f1203
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2987
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.72% / 71.64%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 17:00
Updated-10 Apr, 2025 | 18:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 GetParentControlInfo stack-based overflow

A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258156. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2983
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.68% / 70.73%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 16:00
Updated-10 Apr, 2025 | 18:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 SetClientState formSetClientState stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14(408) and classified as critical. Affected by this issue is the function formSetClientState of the file /goform/SetClientState. The manipulation of the argument deviceId/limitSpeed/limitSpeedUp leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258152. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2985
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.01% / 76.22%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 16:31
Updated-14 Jan, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-258154 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2984
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.68% / 70.73%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 16:00
Updated-14 Jan, 2025 | 15:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been classified as critical. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258153 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2979
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.13%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 14:00
Updated-15 Jan, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 openSchedWifi setSchedWifi stack-based overflow

A vulnerability classified as critical was found in Tenda F1203 2.0.1.6. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258148. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203f1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2981
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.19% / 77.94%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 15:00
Updated-14 Jan, 2025 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258150 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2988
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.53% / 66.39%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 17:31
Updated-15 Jan, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 fromRouteStatic fromSetRouteStatic stack-based overflow

A vulnerability classified as critical was found in Tenda FH1203 2.0.1.6. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258157 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3006
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.45% / 62.71%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 22:31
Updated-15 Jan, 2025 | 18:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 fromRouteStatic fromSetRouteStatic stack-based overflow

A vulnerability classified as critical was found in Tenda FH1205 2.0.0.7(775). This vulnerability affects the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258292. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2977
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.52% / 65.94%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 13:31
Updated-15 Jan, 2025 | 18:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2994
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.53% / 66.39%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 19:31
Updated-15 Jan, 2025 | 18:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 GetParentControlInfo stack-based overflow

A vulnerability was found in Tenda FH1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258163. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2764
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.73% / 71.71%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 20:31
Updated-12 Dec, 2024 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2892
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.21% / 43.81%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 16:00
Updated-22 Jan, 2025 | 17:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 setcfm formSetCfm stack-based overflow

A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2763
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.84% / 73.71%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 20:31
Updated-12 Dec, 2024 | 17:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U setcfm formSetCfm stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10U
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2893
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.26% / 49.29%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 16:31
Updated-22 Jan, 2025 | 17:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2900
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.95% / 75.41%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 19:31
Updated-22 Jan, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 saveParentControlInfo stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2901
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.13%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 20:00
Updated-22 Jan, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 openSchedWifi setSchedWifi stack-based overflow

A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2805
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.04% / 76.60%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 03:00
Updated-24 Jan, 2025 | 18:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetSpeedWan formSetSpeedWan stack-based overflow

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been rated as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257660. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2899
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.13%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 19:00
Updated-10 Apr, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WifiExtraSet fromSetWirelessRepeat stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2898
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.86% / 74.14%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 18:31
Updated-22 Jan, 2025 | 17:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetStaticRouteCfg fromSetRouteStatic stack-based overflow

A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2896
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.13%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 18:00
Updated-22 Jan, 2025 | 17:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WifiWpsStart formWifiWpsStart stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. This issue affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257939. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2894
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.13%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 17:00
Updated-22 Jan, 2025 | 17:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetNetControlList formSetQosBand stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2705
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.86% / 74.21%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 16:31
Updated-12 Dec, 2024 | 17:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetNetControlList formSetQosBand stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2708
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.44% / 62.32%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 17:31
Updated-12 Dec, 2024 | 17:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U execCommand formexeCommand stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4240
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.37% / 58.15%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 20:31
Updated-27 Jan, 2025 | 18:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 formQosManageDouble_user stack-based overflow

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. This affects the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9w9_firmwareW9w9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-7586
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.10% / 27.61%
||
7 Day CHG~0.00%
Published-14 Jul, 2025 | 08:02
Updated-17 Jul, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 setWtpData formSetAPCfg stack-based overflow

A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. Affected by this vulnerability is the function formSetAPCfg of the file /goform/setWtpData. The manipulation of the argument radio_2g_1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500_firmwareac500AC500
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2581
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.61% / 68.72%
||
7 Day CHG~0.00%
Published-18 Mar, 2024 | 03:00
Updated-22 Jan, 2025 | 17:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 SetStaticRouteCfg fromSetRouteStatic stack-based overflow

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-28664
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.13% / 33.79%
||
7 Day CHG~0.00%
Published-10 May, 2021 | 00:00
Updated-30 Jul, 2025 | 01:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2021-11-17||Apply updates per vendor instructions.

The Arm Mali GPU kernel driver allows privilege escalation or a denial of service (memory corruption) because an unprivileged user can achieve read/write access to read-only pages. This affects Bifrost r0p0 through r29p0 before r30p0, Valhall r19p0 through r29p0 before r30p0, and Midgard r8p0 through r30p0 before r31p0.

Action-Not Available
Vendor-n/aArm Limited
Product-bifrost_gpu_kernel_drivermidgard_gpu_kernel_drivervalhall_gpu_kernel_drivern/aMali Graphics Processing Unit (GPU)
CWE ID-CWE-787
Out-of-bounds Write
CVE-2018-9450
Matching Score-4
Assigner-Android (associated with Google Inc. or Open Handset Alliance)
ShareView Details
Matching Score-4
Assigner-Android (associated with Google Inc. or Open Handset Alliance)
CVSS Score-8.8||HIGH
EPSS-7.03% / 91.12%
||
7 Day CHG~0.00%
Published-06 Nov, 2018 | 17:00
Updated-16 Sep, 2024 | 19:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In avrc_proc_vendor_command of avrc_api.cc, there is a possible out of bounds write due to a missing bounds check. This could lead to remote code execution with no additional execution privileges needed. User interaction is not needed for exploitation. Product: Android Versions: Android-6.0 Android-6.0.1 Android-7.0 Android-7.1.1 Android-7.1.2 Android-8.0 Android-8.1 Android ID: A-79541338.

Action-Not Available
Vendor-Google LLC
Product-androidAndroid
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2547
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.24% / 46.68%
||
7 Day CHG~0.00%
Published-17 Mar, 2024 | 03:31
Updated-27 Jan, 2025 | 17:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 R7WebsSecurityHandler stack-based overflow

A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 8
  • 9
  • Next
Details not found