A vulnerability classified as critical was found in SourceCodester Online Pizza Ordering System 1.0. Affected by this vulnerability is the function delete_category of the file ajax.php of the component POST Parameter Handler. The manipulation leads to missing authentication. The attack can be launched remotely. The associated identifier of this vulnerability is VDB-221455.
An issue was discovered in Echo ShareCare 8.15.5. It does not perform authentication or authorization checks when accessing a subset of sensitive resources, leading to the ability for unauthenticated users to access pages that are vulnerable to attacks such as SQL injection.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the Script Parser AddOn through 1.8 installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the exec.cgi script, which executes TCL script content from an HTTP POST request.
Vulnerability in the Oracle Access Manager product of Oracle Fusion Middleware (component: OpenSSO Agent). Supported versions that are affected are 11.1.2.3.0, 12.2.1.3.0 and 12.2.1.4.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Access Manager. Successful attacks of this vulnerability can result in takeover of Oracle Access Manager. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
A vulnerability in the user registration component found in the ~/src/Classes/RegistrationAuth.php file of the ProfilePress WordPress plugin made it possible for users to register on sites as an administrator. This issue affects versions 3.0.0 - 3.1.3. .
The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the HM-Print AddOn through 1.2a installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the exec.cgi and exec1.cgi scripts, which execute TCL script content from an HTTP POST request.
An issue was discovered in the Responsive Poll through 1.3.4 for Wordpress. It allows an unauthenticated user to manipulate polls, e.g., delete, clone, or view a hidden poll. This is due to the usage of the callback wp_ajax_nopriv function in Includes/Total-Soft-Poll-Ajax.php for sensitive operations.
Improper Authorization vulnerability of Pepperl+Fuchs P+F Comtrol RocketLinx ES7510-XT, ES8509-XT, ES8510-XT, ES9528-XTv2, ES7506, ES7510, ES7528, ES8508, ES8508F, ES8510, ES8510-XTE, ES9528/ES9528-XT (all versions) allows unauthenticated device administration.
This vulnerability allows remote attackers to issue commands on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to issue commands to the physical equipment controlled by the device. Was ZDI-CAN-10482.
xlockmore 5.13 and 5.22 segfaults when using libpam-opensc and returns the underlying xsession. This allows unauthorized users access to the X session.
xlockmore 5.13 allows potential xlock bypass when FVWM switches to the same virtual desktop as a new Gaim window.
The Micro Air Vehicle Link (MAVLink) protocol presents no authentication mechanism on its version 1.0 (nor authorization) whichs leads to a variety of attacks including identity spoofing, unauthorized access, PITM attacks and more. According to literature, version 2.0 optionally allows for package signing which mitigates this flaw. Another source mentions that MAVLink 2.0 only provides a simple authentication system based on HMAC. This implies that the flying system overall should add the same symmetric key into all devices of network. If not the case, this may cause a security issue, that if one of the devices and its symmetric key are compromised, the whole authentication system is not reliable.
WebAccess/NMS (versions prior to 3.0.2) allows an unauthenticated remote user to create a new admin account.
eQ-3 Homematic CCU2 prior to 2.47.10 and CCU3 prior to 3.47.10 JSON API has Improper Access Control for Interface.***Metadata related operations, resulting in the ability to read, set and deletion of Metadata.
The SolarWinds Orion API is vulnerable to an authentication bypass that could allow a remote attacker to execute API commands. This vulnerability could allow a remote attacker to bypass authentication and execute API commands which may result in a compromise of the SolarWinds instance. SolarWinds Orion Platform versions 2019.4 HF 5, 2020.2 with no hotfix installed, and 2020.2 HF 1 are affected.
The WPGraphQL 0.2.3 plugin for WordPress allows remote attackers to register a new user with admin privileges, whenever new user registrations are allowed. This is related to the registerUser mutation.
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the device's web server might be able to execute administrative commands without authentication.
Jector Smart TV FM-K75 devices allow remote code execution because there is an adb open port with root permission.
D-Link DWL-900AP+ Access Point 2.1 and 2.2 allows remote attackers to access the TFTP server without authentication and read the config.img file, which contains sensitive information such as the administrative password, the WEP encryption keys, and network configuration information.
eQ-3 Homematic CCU2 before 2.47.18 and CCU3 before 3.47.18 allow Remote Code Execution by unauthenticated attackers with access to the web interface via an HTTP POST request to certain URLs related to the ReGa core process.
An issue was discovered on D-Link DIR-878 1.12B01 devices. Because strncpy is misused, there is a stack-based buffer overflow vulnerability that does not require authentication via the HNAP_AUTH HTTP header.
On Netis WF2411 with firmware 2.1.36123 and other Netis WF2xxx devices (possibly WF2411 through WF2880), there is a stack-based buffer overflow that does not require authentication. This can cause denial of service (device restart) or remote code execution. This vulnerability can be triggered by a GET request with a long HTTP "Authorization: Basic" header that is mishandled by user_auth->user_ok in /bin/boa.
Missing authentication and improper input validation in KERUI Wifi Endoscope Camera (YPC99) allow an attacker to execute arbitrary commands (with a length limit of 19 characters) via the "ssid" value, as demonstrated by ssid:;ping 192.168.1.2 in the body of a SETSSID command.
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as "CWE-284: Improper Access Control." This vulnerability, for example, allows a potential attacker to delete video or read video data.
ONTAP Select Deploy administration utility versions 2.12 & 2.12.1 ship with an HTTP service bound to the network allowing unauthenticated remote attackers to perform administrative actions.
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.
HiNet GPON firmware version < I040GWR190731 allows an attacker login to device without any authentication.
The nd-restaurant-reservations plugin before 1.5 for WordPress has no requirement for nd_rst_import_settings_php_function authentication.
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus.
ABB MicroSCADA Pro SYS600 version 9.3 suffers from an instance of CWE-306: Missing Authentication for Critical Function.
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.
It was found that default configuration of Heketi does not require any authentication potentially exposing the management interface to misuse. This isue only affects heketi as shipped with Openshift Container Platform 3.11.
A vulnerability, which was classified as critical, was found in MAXTECH MAX-G866ac 0.4.1_TBRO_20160314. This affects an unknown part of the component Remote Management. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227001 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the E-Mail AddOn through 1.6.8.c installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the save.cgi script for payload upload and the testtcl.cgi script for its execution.
In NICE Engage through 6.5, the default configuration binds an unauthenticated JMX/RMI interface to all network interfaces, without restricting registration of MBeans, which allows remote attackers to execute arbitrary code via the RMI protocol by using the JMX connector. The observed affected TCP port is 6338 but, based on the product's configuration, a different one could be vulnerable.
A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device.
Systematic IRIS WebForms 5.4 and its functionalities can be accessed and used without any form of authentication.
wan.htm page on Zyxel NBG-418N v2 with firmware version V1.00(AARP.9)C0 can be accessed directly without authentication, which can lead to disclosure of information about the WAN, and can also be leveraged by an attacker to modify data fields of the page.
The RSA Identity Governance and Lifecycle and RSA Via Lifecycle and Governance products prior to 7.1.1 P03 contain an Improper Authentication vulnerability. A Java JMX agent running on the remote host is configured with plain text password authentication. An unauthenticated remote attacker can connect to the JMX agent and monitor and manage the Java application.
An issue was discovered in the LifterLMS plugin through 3.34.5 for WordPress. The upload_import function in the class.llms.admin.import.php script is prone to an unauthenticated options import vulnerability that could lead to privilege escalation (administrator account creation), website redirection, and stored XSS.
The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has a Missing Authentication for Critical Function (CWE-306) vulnerability. The affected product does not require authentication for TELNET access, which may allow an attacker to change configuration or perform other malicious activities.
Intesync Solismed 3.3sp has Incorrect Access Control.
RedwoodHQ 2.5.5 does not require any authentication for database operations, which allows remote attackers to create admin users via a con.automationframework users insert_one call.
An issue was discovered in Zoho ManageEngine OpManager in builds before 14310. One can bypass the user password requirement and execute commands on the server. The "username+'@opm' string is used for the password. For example, if the username is admin, the password is admin@opm.
An issue was discovered in Tyto Sahi Pro 6.x through 8.0.0. TestRunner_Non_distributed (and distributed end points) does not have any authentication mechanism. This allow an attacker to execute an arbitrary script on the remote Sahi Pro server. There is also a password-protected web interface intended for remote access to scripts. This web interface lacks server-side validation, which allows an attacker to create/modify/delete a script remotely without any password. Chaining both of these issues results in remote code execution on the Sahi Pro server.
A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.
Directus 7 API before 2.2.2 has insufficient anti-automation, as demonstrated by lack of a CAPTCHA in core/Directus/Services/AuthService.php and endpoints/Auth.php.
OSRAM SYLVANIA Osram Lightify Home before 2016-07-26 allows remote attackers to execute arbitrary commands via TCP port 4000.
HPE Data Protector before 7.03_108, 8.x before 8.15, and 9.x before 9.06 allow remote attackers to execute arbitrary code via unspecified vectors related to lack of authentication. NOTE: this vulnerability exists because of an incomplete fix for CVE-2014-2623.