The ZyXEL P660HN-T1A v2 TCLinux Fw #7.3.37.6 router distributed by TrueOnline has a command injection vulnerability in the Remote System Log forwarding function, which is only accessible by an authenticated user. The vulnerability is in the logSet.asp page and can be exploited through the ServerIP parameter. Authentication can be achieved by exploiting CVE-2017-18371.
The ZyXEL P660HN-T1A v1 TCLinux Fw $7.3.15.0 v001 / 3.40(ULM.0)b31 router distributed by TrueOnline has two user accounts with default passwords, including a hardcoded service account with the username true and password true. These accounts can be used to login to the web interface, exploit authenticated command injections and change router settings for malicious purposes.
The Billion 5200W-T TCLinux Fw $7.3.8.0 v008 130603 router distributed by TrueOnline has a command injection vulnerability in the Time Setting function, which is only accessible by an authenticated user. The vulnerability is in the tools_time.asp page and can be exploited through the uiViewSNTPServer parameter. Authentication can be achieved by exploiting CVE-2017-18373.
**UNSUPPORTED WHEN ASSIGNED** A post-authentication command injection vulnerability in the management commands of the legacy DSL CPE Zyxel VMG4325-B10A firmware version 1.00(AAFR.4)C0_20170615 could allow an authenticated attacker to execute operating system (OS) commands on an affected device via Telnet.
**UNSUPPORTED WHEN ASSIGNED** A post-authentication command injection vulnerability in the CGI program of the legacy DSL CPE Zyxel VMG4325-B10A firmware version 1.00(AAFR.4)C0_20170615 could allow an authenticated attacker to execute operating system (OS) commands on an affected device by sending a crafted HTTP POST request.
An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. User accounts created through the web interface of the device, when given non-admin level privileges, have the same level of privileged access as administrators when connecting to the device via SSH (while their permissions via the web interface are in fact restricted). This allows normal users to obtain the administrative password by running the tech-support command via the CLI: this contains the encrypted passwords for all users on the device. As these passwords are encrypted using well-known and static parameters, they can be decrypted and the original passwords (including the administrator password) can be obtained.
The post-authentication command injection vulnerability in the CLI command of Zyxel ATP series firmware versions 4.32 through 5.35, USG FLEX series firmware versions 4.50 through 5.35, USG FLEX 50(W) firmware versions 4.16 through 5.35, USG20(W)-VPN firmware versions 4.16 through 5.35, and VPN series firmware versions 4.30 through 5.35, which could allow an authenticated attacker to execute some OS commands remotely.
The post-authentication command injection vulnerability in the Zyxel NBG6604 firmware version V1.01(ABIR.0)C0 could allow an authenticated attacker to execute some OS commands remotely by sending a crafted HTTP request.
Certain Zyxel products allow command injection by an admin via an input string to chg_exp_pwd during a password-change action. This affects VPN On-premise before ZLD V4.39 week38, VPN Orchestrator before SD-OS V10.03 week32, USG before ZLD V4.39 week38, USG FLEX before ZLD V4.55 week38, ATP before ZLD V4.55 week38, and NSG before 1.33 patch 4.
A system command injection vulnerability in zyshclient in ZyXEL NSA325 V2 version 4.81 allows attackers to execute system commands via the web application API.
A command injection vulnerability in the CGI program of Zyxel NR7101 firmware prior to V1.15(ACCC.3)C0, which could allow an authenticated attacker to execute some OS commands on a vulnerable device by sending a crafted HTTP request.
An improper privilege management vulnerability in the web management interface of the Zyxel WBE530 firmware versions through 7.00(ACLE.3) and WBE660S firmware versions through 6.70(ACGG.2) could allow an authenticated user with limited privileges to escalate their privileges to that of an administrator, enabling them to upload configuration files to a vulnerable device.
Cisco Application Policy Infrastructure Controller (APIC) devices with software before 1.0(3h) and 1.1 before 1.1(1j) and Nexus 9000 ACI Mode switches with software before 11.0(3h) and 11.1 before 11.1(1j) allow remote authenticated users to bypass intended RBAC restrictions via crafted REST requests, aka Bug ID CSCut12998.
ZyXEL PK5001Z devices have zyad5001 as the su password, which makes it easier for remote attackers to obtain root access if a non-root account password is known (or a non-root default account exists within an ISP's deployment of these devices).
A backdoor in certain Zyxel products allows remote TELNET access via a CGI script. This affects NAS520 V5.21(AASZ.4)C0, V5.21(AASZ.0)C0, V5.11(AASZ.3)C0, and V5.11(AASZ.0)C0; NAS542 V5.11(ABAG.0)C0, V5.20(ABAG.1)C0, and V5.21(ABAG.3)C0; NSA325 v2_V4.81(AALS.0)C0 and V4.81(AAAJ.1)C0; NSA310 4.22(AFK.0)C0 and 4.22(AFK.1)C0; NAS326 V5.21(AAZF.8)C0, V5.11(AAZF.4)C0, V5.11(AAZF.2)C0, and V5.11(AAZF.3)C0; NSA310S V4.75(AALH.2)C0; NSA320S V4.75(AANV.2)C0 and V4.75(AANV.1)C0; NSA221 V4.41(AFM.1)C0; and NAS540 V5.21(AATB.5)C0 and V5.21(AATB.3)C0.
Zyxel VMG5313-B30B router on firmware 5.13(ABCJ.6)b3_1127, and possibly older versions of firmware are affected by shell injection.
A command injection vulnerability was discovered on the Zyxel EMG2926 home router with firmware V1.00(AAQT.4)b8. The vulnerability is located in the diagnostic tools, specifically the nslookup function. A malicious user may exploit numerous vectors to execute arbitrary commands on the router, such as the ping_ip parameter to the expert/maintenance/diagnostic/nslookup URI.
The improper neutralization of special elements in the CGI program of the Zyxel NAS326 firmware version V5.21(AAZF.14)C0 and NAS542 firmware version V5.21(ABAG.11)C0 could allow an authenticated attacker to execute some operating system (OS) commands by sending a crafted URL to a vulnerable device.
A post-authentication command injection vulnerability in the WSGI server of the Zyxel NAS326 firmware version V5.21(AAZF.14)C0 and NAS542 firmware version V5.21(ABAG.11)C0 could allow an authenticated attacker to execute some operating system (OS) commands by sending a crafted URL to a vulnerable device.
A post-authentication command injection vulnerability in the NTP feature of Zyxel NBG6604 firmware version V1.01(ABIR.1)C0 could allow an authenticated attacker to execute some OS commands remotely by sending a crafted HTTP request.
An authentication bypasss vulnerability in the web-based management interface of Zyxel USG/Zywall series firmware versions 4.35 through 4.64 and USG Flex, ATP, and VPN series firmware versions 4.35 through 5.01, which could allow a remote attacker to execute arbitrary commands on an affected device.
The Zyxel P-2602HW-D1A router with 3.40(AJZ.1) firmware maintains authentication state by IP address, which allows remote attackers to bypass authentication by establishing a session from a source IP address of a user who previously authenticated within the previous 5 minutes.
An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Through an undocumented sequence of keypresses, undocumented functionality is triggered. A diagnostics shell is triggered via CTRL-ALT-t, which prompts for the password returned by fds_sys_passDebugPasswd_ret(). The firmware contains access control checks that determine if remote users are allowed to access this functionality. The function that performs this check (fds_sys_remoteDebugEnable_ret in libfds.so) always return TRUE with no actual checks performed. The diagnostics menu allows for reading/writing arbitrary registers and various other configuration parameters which are believed to be related to the network interface chips.
A vulnerability in specific versions of Zyxel NBG6818, NBG7815, WSQ20, WSQ50, WSQ60, and WSR30 firmware with pre-configured password management could allow an attacker to obtain root access of the device, if the local attacker dismantles the device and uses a USB-to-UART cable to connect the device, or if the remote assistance feature had been enabled by an authenticated user.
**UNSUPPORTED WHEN ASSIGNED** The improper authentication vulnerability in the Zyxel P-6101C ADSL modem firmware version P-6101CSA6AP_20140331 could allow an unauthenticated attacker to read some device information via a crafted HTTP HEAD method.
The Openfire server in Cisco Finesse Desktop 10.5(1) and 11.0(1) and Unified Contact Center Express 10.6(1) has a hardcoded account, which makes it easier for remote attackers to obtain access via an XMPP session, aka Bug ID CSCuw79085.
A flaw in the Zyxel LTE3301-M209 firmware verisons prior to V1.00(ABLG.6)C0 could allow a remote attacker to access the device using an improper pre-configured password if the remote administration feature has been enabled by an authenticated administrator.
Cisco NX-OS 6.0(2)U6(1) through 6.0(2)U6(5) on Nexus 3000 devices and 6.0(2)A6(1) through 6.0(2)A6(5) and 6.0(2)A7(1) on Nexus 3500 devices has hardcoded credentials, which allows remote attackers to obtain root privileges via a (1) TELNET or (2) SSH session, aka Bug ID CSCuy25800.
The ZyXEL Wireless N300 NetUSB NBG-419N router with firmware 1.00(BFQ.6)C0 allows remote attackers to bypass authentication by using %2F sequences in place of / (slash) characters.
ZyXEL Prestige routers, including P-660, P-661, and P-662 models with firmware 3.40(AGD.2) through 3.40(AHQ.3), allow remote authenticated users to obtain authentication data by making direct HTTP requests and then reading the HTML source, as demonstrated by a request for (1) RemMagSNMP.html, which discloses SNMP communities; or (2) WLAN.html, which discloses WEP keys.
An authentication bypass vulnerability in the CGI program of Zyxel USG/ZyWALL series firmware versions 4.20 through 4.70, USG FLEX series firmware versions 4.50 through 5.20, ATP series firmware versions 4.32 through 5.20, VPN series firmware versions 4.30 through 5.20, and NSG series firmware versions V1.20 through V1.33 Patch 4, which could allow an attacker to bypass the web authentication and obtain administrative access of the device.
A downgrade from two-factor authentication to one-factor authentication vulnerability in the CGI program of Zyxel USG/ZyWALL series firmware versions 4.32 through 4.71, USG FLEX series firmware versions 4.50 through 5.21, ATP series firmware versions 4.32 through 5.21, and VPN series firmware versions 4.32 through 5.21, that could allow an authenticated attacker to bypass the second authentication phase to connect the IPsec VPN server even though the two-factor authentication (2FA) was enabled.
An improper authentication vulnerability in the authentication module of the Zyxel NAS326 firmware version V5.21(AAZF.14)C0 and NAS542 firmware version V5.21(ABAG.11)C0 could allow an unauthenticated attacker to obtain system information by sending a crafted URL to a vulnerable device.
On Zyxel NBG2105 V1.00(AAGU.2)C0 devices, setting the login cookie to 1 provides administrator access.
Privilege Escalation in OpenText Dimensions RM allows an authenticated user to escalate there privilege to the privilege of another user via HTTP Request
Glewlwyd 2.0.0, fixed in 2.6.1 is affected by an incorrect access control vulnerability. One user can attempt to log in as another user without its password.
The HomeAutomationGateway service in MiCasaVerde VeraLite with firmware 1.5.408 allows (1) remote attackers to execute arbitrary Lua code via a RunLua action in a request to upnp/control/hag on port 49451 or (2) remote authenticated users to execute arbitrary Lua code via a RunLua action in a request to port_49451/upnp/control/hag.
eLabFTW is an electronic lab notebook manager for research teams. In versions prior to 4.2.0 there is a vulnerability which allows any authenticated user to gain access to arbitrary accounts by setting a specially crafted email address. This vulnerability impacts all instances that have not set an explicit email domain name allowlist. Note that whereas neither administrators nor targeted users are notified of a change, an attacker will need to control an account. The default settings require administrators to validate newly created accounts. The problem has been patched. Users should upgrade to at least version 4.2.0. For users unable to upgrade enabling an email domain allow list (from Sysconfig panel, Security tab) will completely resolve the issue.
Insufficient security checks exist in the recovery procedure used by the Foscam C1 Indoor HD Camera running application firmware 2.52.2.43. A HTTP request can allow for a user to perform a firmware upgrade using a crafted image. Before any firmware upgrades in this image are flashed to the device, binaries as well as arguments to shell commands contained in the image are executed with elevated privileges.
It was found that there were no permission checks performed in the Distributed Fork plugin before and including 1.5.0 for Jenkins that provides the dist-fork CLI command beyond the basic check for Overall/Read permission, allowing anyone with that permission to run arbitrary shell commands on all connected nodes.
Certain NETGEAR devices are affected by authentication bypass. This affects D6100 before V1.0.0.55, D7000 before V1.0.1.50, D7800 before V1.0.1.24, JNR1010v2 before 1.1.0.40, JWNR2010v5 before 1.1.0.40, R6100 before 1.0.1.12, R6220 before 1.1.0.50, R7500 before 1.0.0.108, R7500v2 before 1.0.3.10, WNDR4300v1 before 1.0.2.88, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, WNR1000v4 before 1.1.0.40, WNR2000v5 before 1.0.0.42, WNR2020 before 1.1.0.40, and WNR2050 before 1.1.0.40.
An issue was discovered in OverIT Geocall 6.3 before build 2:346977. Weak authentication and session management allows an authenticated user to obtain access to the Administrative control panel and execute administrative functions.
A flaw was found in the reset credential flow in all Keycloak versions before 8.0.0. This flaw allows an attacker to gain unauthorized access to the application.
Adobe Commerce versions 2.4.7-p2, 2.4.6-p7, 2.4.5-p9, 2.4.4-p10 and earlier are affected by an Improper Authentication vulnerability that could result in a security feature bypass. A low-privileged attacker could leverage this vulnerability to gain unauthorized access without proper credentials. Exploitation of this issue does not require user interaction.
A authentication bypass vulnerability exists in GitLab CE/EE <v12.3.2, <v12.2.6, and <v12.1.10 in the Salesforce login integration that could be used by an attacker to create an account that bypassed domain restrictions and email verification requirements.
ArmorX Android APP's multi-factor authentication (MFA) for the login function is not properly implemented. Remote attackers who obtain user credentials can bypass MFA, allowing them to successfully log into the APP.
An improper authentication vulnerability [CWE-287] in FortiOS versions 7.4.1 and below, versions 7.2.6 and below, and versions 7.0.12 and below when configured with FortiAuthenticator in HA may allow a readonly user to gain read-write access via successive login attempts.
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.87; SIPROTEC 7UT686 : All versions < V 4.02; SIPROTEC 7SD686 : All versions < V 4.05; SIPROTEC 7SJ66 : All versions < V 4.30. Attackers with network access to the device's web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful.
A flaw was found in SSSD version 1.9.0. The SSSD's access-provider logic causes the result of the HBAC rule processing to be ignored in the event that the access-provider is also handling the setup of the user's SELinux user context.
AIMANAGER before B115 on MONITORAPP Application Insight Web Application Firewall (AIWAF) devices with Manager 2.1.0 has Improper Authentication. An attacker can gain administrative access by modifying the response to an authentication check request.