This affects the package datatables.net before 1.11.3. If an array is passed to the HTML escape entities function it would not have its contents escaped.
Auto Dealer Management System v1.0 was discovered to contain a cross-site scripting (XSS) vulnerability via the name parameter at /classes/SystemSettings.php?f=update_settings.
Cross-site scripting in ajaxdata.php in TerraMaster TOS version 3.1.03 allows attackers to execute JavaScript via the "lines" URL parameter.
Cross-site scripting (XSS) vulnerability on BUFFALO BHR-4GRV2 devices with firmware 1.04 and earlier, WEX-300 devices with firmware 1.90 and earlier, WHR-1166DHP devices with firmware 1.90 and earlier, WHR-300HP2 devices with firmware 1.90 and earlier, WHR-600D devices with firmware 1.90 and earlier, WMR-300 devices with firmware 1.90 and earlier, WMR-433 devices with firmware 1.01 and earlier, and WSR-1166DHP devices with firmware 1.01 and earlier allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
This affects the package video.js before 7.14.3. The src attribute of track tag allows to bypass HTML escaping and execute arbitrary code.
A vulnerability has been found in SourceCodester/code-projects Online Boat Reservation System 1.0 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /boat/login.php of the component POST Parameter Handler. The manipulation of the argument un leads to cross site scripting. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
The GTranslate plugin before 2.8.52 for WordPress has Reflected XSS via a crafted link. This requires use of the hreflang tags feature within a sub-domain or sub-directory paid option.
LavaLite CMS v 9.0.0 was discovered to be vulnerable to a host header injection attack.
The aryo-activity-log plugin before 2.3.3 for WordPress has XSS.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
An issue was discovered in MB connect line mymbCONNECT24 and mbCONNECT24 software in all versions through V2.6.2. There is an XSS issue in the redirect.php allowing an attacker to inject code via a get parameter.
The Goto WordPress theme before 2.0 does not sanitise the keywords and start_date GET parameter on its Tour List page, leading to an unauthenticated reflected Cross-Site Scripting issue.
Unvalidated input and lack of output encoding in the WP Customer Reviews WordPress plugin, versions before 3.4.3, lead to multiple Stored Cross-Site Scripting vulnerabilities allowing remote attackers to inject arbitrary JavaScript code or HTML.
A vulnerability in Pulse Connect Secure before 9.1R12 could allow a threat actor to perform a cross-site script attack against an authenticated administrator via an unsanitized web parameter.
An issue was discovered in the Bose Soundtouch app 18.1.4 for iOS. There is no frontend input validation of the device name. A malicious device name can execute JavaScript on the registered Bose User Account if a speaker has been connected to the app.
A Cross Site Scripting (XSS) vulnerability in Sitecom WLX-2006 Wall Mount Range Extender N300 v1.5 and before allows an attacker to manipulate the language cookie to inject malicious JavaScript code.
The OpenID Connect Generic Client WordPress plugin 3.8.0 and 3.8.1 did not sanitise the login error when output back in the login form, leading to a reflected Cross-Site Scripting issue. This issue does not require authentication and can be exploited with the default configuration.
Cross-site Scripting (XSS) - Reflected in GitHub repository phpipam/phpipam prior to v1.5.1.
Affected versions of this package are vulnerable to Cross-site Scripting (XSS) via the main functionality. It accepts input that can result in the output (an anchor a tag) containing undesirable Javascript code that can be executed upon user interaction.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
An error in the handling of a page parameter in Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. This issue only affects versions 7.7x and 7.6x. All other versions are not affected.
The package apexcharts before 3.24.0 are vulnerable to Cross-site Scripting (XSS) via lack of sanitization of graph legend fields.
Multiple cross-site scripting (XSS) vulnerabilities in the Manager application in Apache Tomcat 6.0.12 through 6.0.29 and 7.0.0 through 7.0.4 allow remote attackers to inject arbitrary web script or HTML via the (1) orderBy or (2) sort parameter to sessionsList.jsp, or unspecified input to (3) sessionDetail.jsp or (4) java/org/apache/catalina/manager/JspHelper.java, related to use of untrusted web applications.
sz.chat version 4 allows injection of web scripts and HTML in the message box.
An issue was discovered in Joomla! 3.9.0 through 3.9.23. The lack of escaping in mod_breadcrumbs aria-label attribute allows XSS attacks.
The fossura-tag-miner plugin before 1.1.5 for WordPress has XSS.
Improper Input Validation vulnerability in OTRS AG OTRS (Ticket Actions modules), OTRS AG ((OTRS)) Community Edition (Ticket Actions modules) allows Cross-Site Scripting (XSS).This issue affects OTRS: from 7.0.X before 7.0.42; ((OTRS)) Community Edition: from 6.0.1 through 6.0.34.
There is a Cross Site Scripting (XSS) vulnerability in the "theme" parameter of preview.php in PHPJabbers Appointment Scheduler v3.0
The universal-analytics plugin before 1.3.1 for WordPress has XSS.
library/DBTech/Security/Action/Sessions.php in DragonByte vBSecurity 3.x through 3.3.0 for vBulletin 3 and vBulletin 4 allows self-XSS via $session['user_agent'] in the "Login Sessions" feature.
The Events Manager – Calendar, Bookings, Tickets, and more! plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via the ‘calendar_header’ parameter in all versions up to, and including, 7.0.3 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that execute if they can successfully trick a user into performing an action such as clicking on a link.
On BIG-IP version 16.0.x before 16.0.1.2, 15.1.x before 15.1.3, 14.1.x before 14.1.4.2, 13.1.x before 13.1.4.1, and all versions of 12.1.x, a DOM based cross-site scripting (XSS) vulnerability exists in an undisclosed page of the BIG-IP Configuration utility that allows an attacker to execute JavaScript in the context of the current logged-in user. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
A vulnerability classified as problematic has been found in SourceCodester Online Student Management System 1.0. Affected is an unknown function of the file profile.php. The manipulation of the argument adminname leads to cross site scripting. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-222984.
Cross-site scripting (XSS) vulnerability in HP Insight Control Performance Management before 6.2 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
This affects the package file-upload-with-preview before 4.2.0. A file containing malicious JavaScript code in the name can be uploaded (a user needs to be tricked into uploading such a file).
quickentity-editor-next is an open source, system local, video game asset editor. In affected versions HTML tags in entity names are not sanitised (XSS vulnerability). Allows arbitrary code execution within the browser sandbox, among other things, simply from loading a file containing a script tag in any entity name. This issue has been patched in version 1.28.1 of the application. Users are advised to upgrade. There are no known workarounds for this vulnerability.
Cross-site scripting (XSS) vulnerability in index.php in common solutions csphonebook 1.02 allows remote attackers to inject arbitrary web script or HTML via the letter parameter.
Veritas Appliance v4.1.0.1 is affected by Host Header Injection attacks. HTTP host header can be manipulated and cause the application to behave in unexpected ways. Any changes made to the header would just cause the request to be sent to a completely different Domain/IP address.
An issue was discovered in OpenTSDB 2.3.0. There is XSS in parameter 'type' to the /suggest URI.
A reflected Cross-site scripting (XSS) vulnerability in Zoho ManageEngine Applications Manager before 13 (Build 13800) allows remote attackers to inject arbitrary web script or HTML via the parameter 'method' to GraphicalView.do.
Cross-site scripting (XSS) vulnerability in advancedsearch.php in eZ Publish 3.7.0 through 4.2.0 allows remote attackers to inject arbitrary web script or HTML via the subTreeItem parameter.
An issue was discovered in Eventum 3.5.0. /htdocs/validate.php has XSS via the values parameter.
Multiple cross-site scripting (XSS) vulnerabilities in XAMPP 1.6.7, when register_globals is enabled, allow remote attackers to inject arbitrary web script or HTML via the text parameter to (1) iart.php and (2) ming.php.
Cross-site scripting (XSS) vulnerability in index.php in PICTURESPRO Photo Cart 3.9 allows remote attackers to inject arbitrary web script or HTML via the qtitle parameter (aka "Gallery or event name" field) in a search action.
In CS-Cart version 4.11.1, it is possible to induce copy-paste XSS by manipulating the "post description" filed in the blog post creation page.
Apache Zeppelin prior to 0.8.0 had a stored XSS issue via Note permissions. Issue reported by "Josna Joseph".
The Advanced Custom Fields Pro WordPress plugin before 5.9.1 did not properly escape the generated update URL when outputting it in an attribute, leading to a reflected Cross-Site Scripting issue in the update settings page.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
This issue was addressed with improved checks. This issue is fixed in iOS 16.7.9 and iPadOS 16.7.9, Safari 17.6, iOS 17.6 and iPadOS 17.6, watchOS 10.6, tvOS 17.6, visionOS 1.3, macOS Sonoma 14.6. Processing maliciously crafted web content may lead to a cross site scripting attack.
CTparental before 4.45.03 is vulnerable to cross-site scripting (XSS) in the CTparental admin panel. In bl_categires_help.php, the 'categories' variable is assigned with the content of the query string param 'cat' without sanitization or encoding, enabling an attacker to inject malicious code into the output webpage.