The User-Defined Functions (UDF) feature in TigerGraph 3.6.0 allows installation of a query (in the GSQL query language) without proper validation. Consequently, an attacker can execute arbitrary C++ code. NOTE: the vendor's position is "GSQL was behaving as expected."
The network proxy page on the web portal for the Zoom on-premise Meeting Connector Controller before version 4.6.348.20201217, Zoom on-premise Meeting Connector MMR before version 4.6.348.20201217, Zoom on-premise Recording Connector before version 3.8.42.20200905, Zoom on-premise Virtual Room Connector before version 4.4.6620.20201110, and Zoom on-premise Virtual Room Connector Load Balancer before version 2.5.5495.20210326 fails to validate input sent in requests to update the network proxy configuration, which could lead to remote command injection on the on-premise image by a web portal administrator.
A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability affects the function formGetDiagnoseInfo. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263080. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263084. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A Heap-based Buffer Overflow vulnerability in the SonicWall SMA100 appliance allows a remote authenticated attacker to cause Denial of Service (DoS) on the appliance or potentially lead to code execution. This vulnerability impacts 10.2.1.5-34sv and earlier versions.
A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263083. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-263086 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263085 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). This issue affects the function formOfflineSet of the file /goform/setStaOffline. The manipulation of the argument GO/ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263081 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). Affected is the function formSetAutoPing. The manipulation of the argument ping1/ping2 leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-263082 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Windows Remote Desktop Licensing Service Spoofing Vulnerability
aiven-extras is a PostgreSQL extension. Versions prior to 1.1.9 contain a privilege escalation vulnerability, allowing elevation to superuser inside PostgreSQL databases that use the aiven-extras package. The vulnerability leverages missing schema qualifiers on privileged functions called by the aiven-extras extension. A low privileged user can create objects that collide with existing function names, which will then be executed instead. Exploiting this vulnerability could allow a low privileged user to acquire `superuser` privileges, which would allow full, unrestricted access to all data and database functions. And could lead to arbitrary code execution or data access on the underlying host as the `postgres` user. The issue has been patched as of version 1.1.9.
Windows Routing and Remote Access Service (RRAS) Remote Code Execution Vulnerability
Windows Routing and Remote Access Service (RRAS) Remote Code Execution Vulnerability
Windows Routing and Remote Access Service (RRAS) Remote Code Execution Vulnerability
In Tensorflow before versions 1.15.4, 2.0.3, 2.1.2, 2.2.1 and 2.3.1, the implementation of `SparseFillEmptyRowsGrad` uses a double indexing pattern. It is possible for `reverse_index_map(i)` to be an index outside of bounds of `grad_values`, thus resulting in a heap buffer overflow. The issue is patched in commit 390611e0d45c5793c7066110af37c8514e6a6c54, and is released in TensorFlow versions 1.15.4, 2.0.3, 2.1.2, 2.2.1, or 2.3.1.
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. Affected by this vulnerability is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). Affected by this issue is the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The identifier of this vulnerability is VDB-262136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-262132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). This affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The identifier VDB-262137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical has been found in Tenda W9 1.0.0.7(4456). Affected is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-262134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been rated as critical. Affected by this issue is the function fromDhcpSetSer of the file /goform/DhcpSetSe. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. This issue affects the function formQosManage_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-262139. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda A301 15.13.08.12_multi_TDE01. It has been rated as critical. This issue affects the function formAddMacfilterRule of the file /goform/setBlackRule. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262223. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. This issue affects the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262130 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Status2k allows Remote Command Execution in admin/options/editpl.php.
A vulnerability has been found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this vulnerability is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical was found in Tenda W9 1.0.0.7(4456). Affected by this vulnerability is the function fromDhcpSetSer of the file /goform/DhcpSetSer. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. Affected is the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262140. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. This vulnerability affects the function formQosManage_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. VDB-262138 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, was found in Tenda AX1806 1.0.0.1. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262128. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. Affected is the function formAddDnsForward of the file /goform/AddDnsForward. The manipulation of the argument DnsForwardRule leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261858 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda 4G300 1.01.42. It has been rated as critical. This issue affects the function sub_429A30. The manipulation of the argument list1 leads to stack-based buffer overflow. The attack may be initiated remotely. The identifier VDB-261989 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda 4G300 1.01.42 and classified as critical. Affected by this issue is the function sub_422AA4. The manipulation of the argument year/month/day/hour/minute/second leads to stack-based buffer overflow. The attack may be launched remotely. VDB-261986 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, has been found in Tenda TX9 22.03.02.10. This issue affects the function sub_42C014 of the file /goform/PowerSaveSet. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261857 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
DP300 V500R002C00,TE60 with software V100R001C01, V100R001C10, V100R003C00, V500R002C00 and V600R006C00,TP3106 with software V100R001C06 and V100R002C00,ViewPoint 9030 with software V100R011C02, V100R011C03,eCNS210_TD with software V100R004C10,eSpace 7950 with software V200R003C00 and V200R003C30,eSpace IAD with software V300R001C07SPCa00 and V300R002C01SPCb00,eSpace U1981 with software V100R001C20, V100R001C30, V200R003C00, V200R003C20 and V200R003C30 have an input validation vulnerability.A remote attacker may exploit this vulnerability by crafting a malformed packet and sending it to the device. A successful exploit could allow the attacker to cause a denial of service or execute arbitrary code.
A vulnerability was found in Tenda 4G300 1.01.42. It has been classified as critical. This affects the function sub_4260F0. The manipulation of the argument upfilen leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-261987. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
On F5 BIG-IP AFM 16.1.x versions prior to 16.1.2.2, 15.1.x versions prior to 15.1.5.1, 14.1.x versions prior to 14.1.4.6, and 13.1.x versions prior to 13.1.5, an authenticated attacker with high privileges can upload a maliciously crafted file to the BIG-IP AFM Configuration utility, which allows an attacker to run arbitrary commands. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
NVIDIA DGX H100 BMC contains a vulnerability in the REST service where an attacker may cause improper input validation. A successful exploit of this vulnerability may lead to escalation of privileges and information disclosure.
A vulnerability was found in Tenda 4G300 1.01.42. It has been declared as critical. This vulnerability affects the function sub_42775C/sub_4279CC. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-261988. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261792. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, has been found in Tenda W15E 15.11.0.14. Affected by this issue is the function formSetPortMapping of the file /goform/SetPortMapping. The manipulation of the argument portMappingServer/portMappingProtocol/portMappingWan/porMappingtInternal/portMappingExternal leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261866 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
OpenZeppelin Contracts is a library for secure smart contract development. The proposal creation entrypoint (`propose`) in `GovernorCompatibilityBravo` allows the creation of proposals with a `signatures` array shorter than the `calldatas` array. This causes the additional elements of the latter to be ignored, and if the proposal succeeds the corresponding actions would eventually execute without any calldata. The `ProposalCreated` event correctly represents what will eventually execute, but the proposal parameters as queried through `getActions` appear to respect the original intended calldata. This issue has been patched in 4.8.3. As a workaround, ensure that all proposals that pass through governance have equal length `signatures` and `calldatas` parameters.
A vulnerability has been found in Tenda W15E 15.11.0.14 and classified as critical. This vulnerability affects the function formSetStaticRoute of the file /goform/setStaticRoute. The manipulation of the argument staticRouteIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261868. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda W15E 15.11.0.14 and classified as critical. Affected by this issue is the function formDelPortMapping of the file /goform/DelPortMapping. The manipulation of the argument portMappingIndex leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261860. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda W15E 15.11.0.14. It has been classified as critical. This affects the function formIPMacBindAdd of the file /goform/addIpMacBind. The manipulation of the argument IPMacBindRule leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261861 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.