Vulnerability Details :

CVE-2020-15787

Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-09 Sep, 2020 | 18:11
Updated At-04 Aug, 2024 | 13:22
Rejected At-
Credits

A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:09 Sep, 2020 | 18:11
Updated At:04 Aug, 2024 | 13:22
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.

Affected Products
Vendor
Siemens AGSiemens
Product
SIMATIC HMI Unified Comfort Panels
Versions
Affected
  • All versions <= V16
Problem Types
TypeCWE IDDescription
CWECWE-305CWE-305: Authentication Bypass by Primary Weakness
Type: CWE
CWE ID: CWE-305
Description: CWE-305: Authentication Bypass by Primary Weakness
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf
x_refsource_MISC
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf
x_refsource_MISC
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:09 Sep, 2020 | 19:15
Updated At:08 Jun, 2021 | 20:15

A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary2.05.0MEDIUM
AV:N/AC:L/Au:N/C:P/I:N/A:N
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 5.0
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:N/C:P/I:N/A:N
CPE Matches

Siemens AG
siemens
>>simatic_hmi_united_comfort_panels_firmware>>*
cpe:2.3:o:siemens:simatic_hmi_united_comfort_panels_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_hmi_united_comfort_panels>>-
cpe:2.3:h:siemens:simatic_hmi_united_comfort_panels:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-305Primaryproductcert@siemens.com
CWE-287Secondarynvd@nist.gov
CWE ID: CWE-305
Type: Primary
Source: productcert@siemens.com
CWE ID: CWE-287
Type: Secondary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdfproductcert@siemens.com
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf
Source: productcert@siemens.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

1206Records found

CVE-2024-56336
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-9.5||CRITICAL
EPSS-0.10% / 27.90%
||
7 Day CHG~0.00%
Published-11 Mar, 2025 | 09:48
Updated-11 Mar, 2025 | 14:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINAMICS S200 (All versions with serial number beginning with SZVS8, SZVS9, SZVS0 or SZVSN and the FS number is 02). The affected device contains an unlocked bootloader. This security oversight enables attackers to inject malicious code, or install untrusted firmware. The intrinsic security features designed to protect against data manipulation and unauthorized access are compromised when the bootloader is not secured.

Action-Not Available
Vendor-Siemens AG
Product-SINAMICS S200
CWE ID-CWE-287
Improper Authentication
CVE-2024-41798
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-9.3||CRITICAL
EPSS-0.20% / 42.01%
||
7 Day CHG~0.00%
Published-08 Oct, 2024 | 08:40
Updated-10 Oct, 2024 | 12:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SENTRON 7KM PAC3200 (All versions). Affected devices only provide a 4-digit PIN to protect from administrative access via Modbus TCP interface. Attackers with access to the Modbus TCP interface could easily bypass this protection by brute-force attacks or by sniffing the Modbus clear text communication.

Action-Not Available
Vendor-Siemens AG
Product-SENTRON 7KM PAC3200sentron_pac3200
CWE ID-CWE-287
Improper Authentication
CVE-2021-44524
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.58% / 67.95%
||
7 Day CHG~0.00%
Published-14 Dec, 2021 | 12:07
Updated-04 Aug, 2024 | 04:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SiPass integrated V2.76 (All versions), SiPass integrated V2.80 (All versions), SiPass integrated V2.85 (All versions), Siveillance Identity V1.5 (All versions), Siveillance Identity V1.6 (All versions < V1.6.284.0). Affected applications insufficiently limit the access to the internal user authentication service. This could allow an unauthenticated remote attacker to trigger several actions on behalf of valid user accounts.

Action-Not Available
Vendor-Siemens AG
Product-sipass_integratedsiveillance_identitySiveillance Identity V1.5SiPass integrated V2.80SiPass integrated V2.85SiPass integrated V2.76Siveillance Identity V1.6
CWE ID-CWE-668
Exposure of Resource to Wrong Sphere
CWE ID-CWE-287
Improper Authentication
CVE-2019-18341
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.06% / 20.18%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) contains an authentication bypass vulnerability. A remote attacker with network access to the CCS server could exploit this vulnerability to read data from the EDIR directory (for example, the list of all configured stations).

Action-Not Available
Vendor-Siemens AG
Product-sinvr_3_video_serversinvr_3_central_control_serverControl Center Server (CCS)
CWE ID-CWE-287
Improper Authentication
CVE-2019-18337
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.07% / 22.98%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-15 Oct, 2024 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an authentication bypass vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. A remote attacker with network access to the CCS server could exploit this vulnerability to read the CCS users database, including the passwords of all users in obfuscated cleartext.

Action-Not Available
Vendor-Siemens AG
Product-sinvr_3_video_serversinvr_3_central_control_serverControl Center Server (CCS)
CWE ID-CWE-287
Improper Authentication
CVE-2019-18332
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.14% / 34.92%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain access to directory listings of the server by sending specifically crafted packets to 80/tcp, 8095/tcp or 8080/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serverSPPA-T3000 Application Server
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CWE ID-CWE-287
Improper Authentication
CVE-2019-18284
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.39% / 59.23%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The AdminService is available without authentication on the Application Server. An attacker can use methods exposed via this interface to receive password hashes of other users and to change user passwords. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serverSPPA-T3000 Application Server
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-18286
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.33% / 55.10%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The Application Server exposes directory listings and files containing sensitive information. This vulnerability is independent from CVE-2019-18287. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serverSPPA-T3000 Application Server
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2019-18287
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.33% / 55.10%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The Application Server exposes directory listings and files containing sensitive information. This vulnerability is independent from CVE-2019-18286. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serverSPPA-T3000 Application Server
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2019-18315
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.02% / 76.33%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted packets to 8888/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serverSPPA-T3000 Application Server
CWE ID-CWE-287
Improper Authentication
CVE-2019-18314
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-2.86% / 85.72%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted objects via RMI. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_application_serverSPPA-T3000 Application Server
CWE ID-CWE-287
Improper Authentication
CVE-2019-18312
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.33% / 55.10%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could be able to enumerate running RPC services. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-287
Improper Authentication
CVE-2023-29129
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-9.1||CRITICAL
EPSS-0.07% / 22.19%
||
7 Day CHG~0.00%
Published-13 Jun, 2023 | 08:17
Updated-03 Jan, 2025 | 01:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions >= V1.17.3 < V1.18.0), Mendix SAML (Mendix 7 compatible) (All versions >= V1.16.4 < V1.17.3), Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 < V2.4.0), Mendix SAML (Mendix 8 compatible) (All versions >= V2.2.0 < V2.3.0), Mendix SAML (Mendix 9 latest compatible, New Track) (All versions >= V3.3.1 < V3.6.1), Mendix SAML (Mendix 9 latest compatible, New Track) (All versions >= V3.1.9 < V3.3.1), Mendix SAML (Mendix 9 latest compatible, Upgrade Track) (All versions >= V3.3.0 < V3.6.0), Mendix SAML (Mendix 9 latest compatible, Upgrade Track) (All versions >= V3.1.8 < V3.3.0), Mendix SAML (Mendix 9.12/9.18 compatible, New Track) (All versions >= V3.3.1 < V3.3.15), Mendix SAML (Mendix 9.12/9.18 compatible, Upgrade Track) (All versions >= V3.3.0 < V3.3.14), Mendix SAML (Mendix 9.6 compatible, New Track) (All versions >= V3.1.9 < V3.2.7), Mendix SAML (Mendix 9.6 compatible, Upgrade Track) (All versions >= V3.1.8 < V3.2.6). The affected versions of the module insufficiently verify the SAML assertions. This could allow unauthenticated remote attackers to bypass authentication and get access to the application. This CVE entry describes the incomplete fix for CVE-2023-25957 in a specific non default configuration.

Action-Not Available
Vendor-mendixSiemens AG
Product-samlMendix SAML (Mendix 9.6 compatible, Upgrade Track)Mendix SAML (Mendix 9 latest compatible, New Track)Mendix SAML (Mendix 9.6 compatible, New Track)Mendix SAML (Mendix 8 compatible)Mendix SAML (Mendix 9.12/9.18 compatible, New Track)Mendix SAML (Mendix 9 latest compatible, Upgrade Track)Mendix SAML (Mendix 9.12/9.18 compatible, Upgrade Track)Mendix SAML (Mendix 7 compatible)
CWE ID-CWE-303
Incorrect Implementation of Authentication Algorithm
CWE ID-CWE-287
Improper Authentication
CVE-2018-4835
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.49% / 64.42%
||
7 Day CHG~0.00%
Published-25 Jan, 2018 | 14:00
Updated-17 Sep, 2024 | 02:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with network access to the TeleControl Server Basic's port 8000/tcp could bypass the authentication mechanism and read limited information.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2018-4841
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-3.00% / 86.04%
||
7 Day CHG~0.00%
Published-29 Mar, 2018 | 13:00
Updated-17 Sep, 2024 | 03:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TIM 1531 IRC (All versions < V1.1). A remote attacker with network access to port 80/tcp or port 443/tcp could perform administrative operations on the device without prior authentication. Successful exploitation could allow to cause a denial-of-service, or read and manipulate data as well as configuration settings of the affected device. At the stage of publishing this security advisory no public exploitation is known. Siemens provides mitigations to resolve it.

Action-Not Available
Vendor-Siemens AG
Product-tim_1531_irc_firmwaretim_1531_ircTIM 1531 IRC
CWE ID-CWE-303
Incorrect Implementation of Authentication Algorithm
CWE ID-CWE-287
Improper Authentication
CVE-2024-23813
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.14% / 35.27%
||
7 Day CHG~0.00%
Published-13 Feb, 2024 | 09:00
Updated-09 May, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Polarion ALM (All versions < V2404.0). The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code.

Action-Not Available
Vendor-Siemens AG
Product-polarion_almPolarion ALM
CWE ID-CWE-287
Improper Authentication
CVE-2022-43400
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.71% / 71.24%
||
7 Day CHG~0.00%
Published-21 Oct, 2022 | 00:00
Updated-07 May, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Siveillance Video Mobile Server V2022 R2 (All versions < V22.2a (80)). The mobile server component of affected applications improperly handles the log in for Active Directory accounts that are part of Administrators group. This could allow an unauthenticated remote attacker to access the application without a valid account.

Action-Not Available
Vendor-Siemens AG
Product-siveillance_video_mobile_serverSiveillance Video Mobile Server V2022 R2
CWE ID-CWE-1390
Weak Authentication
CWE ID-CWE-287
Improper Authentication
CVE-2022-33139
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.39% / 59.26%
||
7 Day CHG~0.00%
Published-21 Jun, 2022 | 00:00
Updated-03 Aug, 2024 | 08:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Cerberus DMS (All versions), Desigo CC (All versions), Desigo CC Compact (All versions), SIMATIC WinCC OA V3.16 (All versions in default configuration), SIMATIC WinCC OA V3.17 (All versions in non-default configuration), SIMATIC WinCC OA V3.18 (All versions in non-default configuration). Affected applications use client-side only authentication, when neither server-side authentication (SSA) nor Kerberos authentication is enabled. In this configuration, attackers could impersonate other users or exploit the client-server protocol without being authenticated.

Action-Not Available
Vendor-Siemens AG
Product-cerberus_dmsdesigo_ccdesigo_cc_compactwincc_open_architectureSIMATIC WinCC OA V3.17Desigo CC CompactSIMATIC WinCC OA V3.16SIMATIC WinCC OA V3.18Cerberus DMSDesigo CC
CWE ID-CWE-603
Use of Client-Side Authentication
CWE ID-CWE-287
Improper Authentication
CVE-2017-9946
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.48% / 64.28%
||
7 Day CHG~0.00%
Published-23 Oct, 2017 | 00:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3.5. An attacker with network access to the integrated web server (80/tcp and 443/tcp) could bypass the authentication and download sensitive information from the device.

Action-Not Available
Vendor-n/aSiemens AG
Product-talon_tc_compact_firmwaretalon_tc_modular_firmwaretalon_tc_modularapogee_pxctalon_tc_compactapogee_pxc_modularapogee_pxc_modular_firmwareapogee_pxc_firmwareAPOGEE PXC and TALON TC BACnet Automation Controllers All versions <V3.5
CWE ID-CWE-287
Improper Authentication
CVE-2024-50557
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.6||HIGH
EPSS-0.73% / 71.74%
||
7 Day CHG~0.00%
Published-12 Nov, 2024 | 12:49
Updated-20 Nov, 2024 | 16:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.2). Affected devices do not properly validate input in configuration fields of the iperf functionality. This could allow an unauthenticated remote attacker to execute arbitrary code on the device.

Action-Not Available
Vendor-Siemens AG
Product-scalance_mum856-1_\(eu\)ruggedcom_rm1224_lte\(4g\)_nam_firmwarescalance_mum856-1_\(b1\)_firmwarescalance_m874-2_firmwarescalance_m874-3scalance_m874-3_\(cn\)scalance_m876-4_\(eu\)ruggedcom_rm1224_lte\(4g\)_euscalance_m812-1_\(annex_b\)scalance_m812-1_\(annex_a\)scalance_mum856-1_\(b1\)scalance_m876-4_\(nam\)scalance_m804pb_firmwarescalance_s615scalance_m874-3_firmwarescalance_m876-3_firmwarescalance_mum853-1_\(b1\)scalance_mum853-1_\(eu\)ruggedcom_rm1224_lte\(4g\)_namscalance_m876-3_\(rok\)_firmwarescalance_m874-3_\(cn\)_firmwarescalance_mum853-1_\(b1\)_firmwarescalance_mum856-1_\(cn\)scalance_s615_firmwarescalance_mum856-1_\(a1\)_firmwarescalance_mum856-1_\(a1\)scalance_mum856-1_\(row\)scalance_m876-3_\(rok\)scalance_mum856-1_\(eu\)_firmwarescalance_mum856-1_\(cn\)_firmwarescalance_m876-3scalance_m876-4_\(eu\)_firmwarescalance_m816-1_\(annex_b\)scalance_m876-4scalance_m876-4_firmwarescalance_mum853-1_\(a1\)_firmwarescalance_s615_eec_firmwarescalance_m826-2scalance_m812-1_\(annex_a\)_firmwarescalance_s615_eecscalance_m874-2scalance_m826-2_firmwarescalance_mum856-1_\(row\)_firmwarescalance_m816-1_\(annex_b\)_firmwarescalance_m804pbscalance_m876-4_\(nam\)_firmwarescalance_m812-1_\(annex_b\)_firmwarescalance_m816-1_\(annex_a\)_firmwarescalance_mum853-1_\(eu\)_firmwarescalance_mum853-1_\(a1\)ruggedcom_rm1224_lte\(4g\)_eu_firmwarescalance_m816-1_\(annex_a\)SCALANCE M874-3 3G-Router (CN)SCALANCE M874-3SCALANCE MUM856-1 (B1)SCALANCE M816-1 ADSL-RouterSCALANCE M876-3 (ROK)SCALANCE MUM856-1 (A1)SCALANCE M812-1 ADSL-RouterSCALANCE M804PBSCALANCE MUM856-1 (EU)SCALANCE MUM853-1 (B1)SCALANCE MUM853-1 (EU)SCALANCE S615 EEC LAN-RouterSCALANCE M874-2SCALANCE M876-4RUGGEDCOM RM1224 LTE(4G) NAMSCALANCE M876-3SCALANCE M826-2 SHDSL-RouterSCALANCE MUM856-1 (CN)SCALANCE MUM856-1 (RoW)RUGGEDCOM RM1224 LTE(4G) EUSCALANCE M876-4 (EU)SCALANCE MUM853-1 (A1)SCALANCE M876-4 (NAM)SCALANCE S615 LAN-Routerscalance_mum856-1_\(eu\)_firmwarescalance_mum856-1_\(cn\)_firmwareruggedcom_rm1224_lte\(4g\)_nam_firmwarescalance_mum856-1_\(b1\)_firmwarescalance_mum853-1_\(a1\)_firmwarescalance_m876-4_firmwarescalance_s615_eec_firmwarescalance_m804pb_firmwarescalance_mum856-1_\(row\)_firmwarescalance_m816-1_\(annex_b\)_firmwarescalance_m874-3_firmwarescalance_m876-3_firmwarescalance_m812-1_\(annex_b\)_firmwarescalance_mum853-1_\(eu\)_firmwarescalance_s615_firmwarescalance_mum853-1_\(b1\)_firmwarescalance_mum856-1_\(a1\)_firmware
CWE ID-CWE-20
Improper Input Validation
CVE-2024-49775
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.3||CRITICAL
EPSS-0.48% / 64.31%
||
7 Day CHG+0.07%
Published-16 Dec, 2024 | 15:06
Updated-12 Mar, 2025 | 16:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Opcenter Execution Foundation (All versions), Opcenter Intelligence (All versions), Opcenter Quality (All versions), Opcenter RDL (All versions), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions if operated in conjunction with UMC < V2.15), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.

Action-Not Available
Vendor-Siemens AG
Product-Opcenter RDLTotally Integrated Automation Portal (TIA Portal) V16Totally Integrated Automation Portal (TIA Portal) V17Opcenter Execution FoundationTotally Integrated Automation Portal (TIA Portal) V18Totally Integrated Automation Portal (TIA Portal) V19SIMATIC PCS neo V5.0SINEC NMSSIMATIC PCS neo V4.0Opcenter QualitySIMATIC PCS neo V4.1Opcenter Intelligence
CWE ID-CWE-122
Heap-based Buffer Overflow
CVE-2017-5689
Matching Score-8
Assigner-Intel Corporation
ShareView Details
Matching Score-8
Assigner-Intel Corporation
CVSS Score-9.8||CRITICAL
EPSS-94.30% / 99.94%
||
7 Day CHG~0.00%
Published-02 May, 2017 | 14:00
Updated-30 Jul, 2025 | 01:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-07-28||Apply updates per vendor instructions.

An unprivileged network attacker could gain system privileges to provisioned Intel manageability SKUs: Intel Active Management Technology (AMT) and Intel Standard Manageability (ISM). An unprivileged local attacker could provision manageability features gaining unprivileged network or local system privileges on Intel manageability SKUs: Intel Active Management Technology (AMT), Intel Standard Manageability (ISM), and Intel Small Business Technology (SBT).

Action-Not Available
Vendor-Siemens AGHewlett Packard Enterprise (HPE)Intel Corporation
Product-simatic_ipc627dsimatic_pcs_7_ipc647csimatic_ipc827d_firmwaresimatic_pcs_7_ipc677c_firmwaresimotion_p320-4_sproliant_ml10_gen9_server_firmwaresimatic_ipc827csimatic_ipc547gsimatic_ipc477d_firmwaresimatic_field_pg_m4_firmwaresimatic_pcs_7_ipc647c_firmwaresimatic_pcs_7_ipc847csimatic_pcs_7_ipc677csimatic_itp1000_firmwaresimatic_ipc847c_firmwaresimatic_ipc647c_firmwaresimatic_ipc427dsimatic_pcs_7_ipc477d_firmwaresimatic_pcs_7_ipc547g_firmwaresinumerik_pcu_50.5-psimatic_pcs_7_ipc847dsimatic_ipc647d_firmwaresimatic_pcs_7_ipc627c_firmwaresimatic_ipc477dsimatic_ipc547g_firmwaresinumerik_pcu50.5-p_firmwaresimatic_ipc477e_firmwaresimatic_pcs_7_ipc427e_firmwaresimatic_pcs_7_ipc627csimatic_ipc647dproliant_ml10_gen9_serversimatic_pcs_7_ipc547d_firmwaresimatic_ipc477esimotion_p320-4_s_firmwaresimatic_ipc547esimatic_field_pg_m3_firmwaresimatic_pcs_7_ipc547e_firmwaresimatic_ipc427esimatic_pcs_7_ipc427esimatic_ipc677csimatic_pcs_7_ipc647dsimatic_pcs_7_ipc847c_firmwareactive_management_technology_firmwaresimatic_pcs_7_ipc647d_firmwaresimatic_ipc427e_firmwaresimatic_ipc547e_firmwaresimatic_ipc827dsimatic_ipc547d_firmwaresimatic_ipc847csimatic_field_pg_m5simatic_ipc647csimatic_ipc547dsimatic_ipc627d_firmwaresimatic_pcs_7_ipc547gsimatic_field_pg_m3simatic_ipc677c_firmwaresimatic_ipc847dsimatic_ipc627csimatic_field_pg_m4simatic_pcs_7_ipc547esimatic_ipc677dsimatic_pcs_7_ipc477dsimatic_ipc627c_firmwaresimatic_pcs_7_ipc547dsimatic_pcs_7_ipc847d_firmwaresimatic_itp1000simatic_field_pg_m5_firmwaresimatic_ipc427d_firmwaresimatic_ipc847d_firmwaresimatic_ipc677d_firmwaresimatic_ipc827c_firmwareIntel Active Mangement Technology, Intel Small Business Technology, Intel Standard ManageabilityActive Management Technology (AMT), Small Business Technology (SBT), and Standard Manageability
CWE ID-CWE-269
Improper Privilege Management
CVE-2021-44522
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.43% / 61.81%
||
7 Day CHG~0.00%
Published-14 Dec, 2021 | 12:07
Updated-04 Aug, 2024 | 04:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SiPass integrated V2.76 (All versions), SiPass integrated V2.80 (All versions), SiPass integrated V2.85 (All versions), Siveillance Identity V1.5 (All versions), Siveillance Identity V1.6 (All versions < V1.6.284.0). Affected applications insufficiently limit the access to the internal message broker system. This could allow an unauthenticated remote attacker to subscribe to arbitrary message queues.

Action-Not Available
Vendor-Siemens AG
Product-sipass_integratedsiveillance_identitySiveillance Identity V1.5SiPass integrated V2.80SiPass integrated V2.85SiPass integrated V2.76Siveillance Identity V1.6
CWE ID-CWE-668
Exposure of Resource to Wrong Sphere
CVE-2021-42021
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-1.00% / 76.00%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:32
Updated-04 Aug, 2024 | 03:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Siveillance Video DLNA Server (2019 R1), Siveillance Video DLNA Server (2019 R2), Siveillance Video DLNA Server (2019 R3), Siveillance Video DLNA Server (2020 R1), Siveillance Video DLNA Server (2020 R2), Siveillance Video DLNA Server (2020 R3), Siveillance Video DLNA Server (2021 R1). The affected application contains a path traversal vulnerability that could allow to read arbitrary files on the server that are outside the application’s web document directory. An unauthenticated remote attacker could exploit this issue to access sensitive information for subsequent attacks.

Action-Not Available
Vendor-Siemens AG
Product-siveillance_video_management_software_2019_r1siveillance_video_management_software_2019_r3siveillance_video_dlna_serversiveillance_video_management_software_2020_r1siveillance_video_management_software_2020_r2siveillance_video_management_software_2019_r2Siveillance Video DLNA Server
CWE ID-CWE-26
Path Traversal: '/dir/../filename'
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-42016
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.14% / 34.64%
||
7 Day CHG~0.00%
Published-08 Mar, 2022 | 11:31
Updated-12 Aug, 2025 | 12:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i801, RUGGEDCOM i802, RUGGEDCOM i803, RUGGEDCOM M2100, RUGGEDCOM M2100F, RUGGEDCOM M2200, RUGGEDCOM M2200F, RUGGEDCOM M969, RUGGEDCOM M969F, RUGGEDCOM RMC30, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RP110, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600T, RUGGEDCOM RS400, RUGGEDCOM RS400F, RUGGEDCOM RS401, RUGGEDCOM RS416, RUGGEDCOM RS416F, RUGGEDCOM RS416P, RUGGEDCOM RS416PF, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000H, RUGGEDCOM RS8000T, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900F, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GF, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPF, RUGGEDCOM RS900L, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930W, RUGGEDCOM RS940G, RUGGEDCOM RS940GF, RUGGEDCOM RS969, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100F, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2100P (32M) V4.X, RUGGEDCOM RSG2100P (32M) V5.X, RUGGEDCOM RSG2100PF, RUGGEDCOM RSG2200, RUGGEDCOM RSG2200F, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300F, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PF, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488F, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V4.X, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSL910, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P. A timing attack, in a third-party component, could make the retrieval of the private key possible, used for encryption of sensitive data. If a threat actor were to exploit this, the data integrity and security could be compromised.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rs969ruggedcom_rs910ruggedcom_rsg2100ruggedcom_rsg2300pruggedcom_rs930lruggedcom_rsg907rruggedcom_rsg910cruggedcom_rs416ruggedcom_rs900wruggedcom_i801ruggedcom_rosruggedcom_m2100ruggedcom_rmcruggedcom_i800ruggedcom_rst2228ruggedcom_rs930wruggedcom_rmc8388ruggedcom_rsg2200ruggedcom_rs900ruggedcom_rs401ruggedcom_rs8000truggedcom_rsg909rruggedcom_rp110ruggedcom_rs910lruggedcom_i802ruggedcom_m969ruggedcom_rs910wruggedcom_rsg2100pruggedcom_rs8000ruggedcom_rst916pruggedcom_rs900gpruggedcom_rs900lruggedcom_rmc40ruggedcom_rsl910ruggedcom_rmc41ruggedcom_rsg920pruggedcom_rs920wruggedcom_rs416v2ruggedcom_rs8000aruggedcom_rsg2300ruggedcom_rst916cruggedcom_m2200ruggedcom_rs400ruggedcom_rst2228pruggedcom_rmc20ruggedcom_rs8000hruggedcom_rsg908cruggedcom_i803ruggedcom_rsg2488ruggedcom_rs900gruggedcom_rsg2288ruggedcom_rs920lruggedcom_rs940gruggedcom_rmc30RUGGEDCOM RS8000RUGGEDCOM RS900LRUGGEDCOM RSG2300 V4.XRUGGEDCOM RSG920P V4.XRUGGEDCOM RS930WRUGGEDCOM RS910LRUGGEDCOM RSG2300P V4.XRUGGEDCOM RS416v2 V5.XRUGGEDCOM RSG2100 (32M) V5.XRUGGEDCOM RS416Pv2 V4.XRUGGEDCOM RS1600RUGGEDCOM RS920WRUGGEDCOM RS940GRUGGEDCOM RS900FRUGGEDCOM M2200RUGGEDCOM RS910RUGGEDCOM RSG908CRUGGEDCOM RS900RUGGEDCOM RS400FRUGGEDCOM RS920LRUGGEDCOM RMC8388 V4.XRUGGEDCOM RSG2100RUGGEDCOM RS8000HRUGGEDCOM RS400RUGGEDCOM RS8000TRUGGEDCOM RS900G (32M) V4.XRUGGEDCOM M969RUGGEDCOM RS416PFRUGGEDCOM RS900GRUGGEDCOM M2100FRUGGEDCOM RS900M-STND-XXRUGGEDCOM RS900WRUGGEDCOM RS8000ARUGGEDCOM RMC8388 V5.XRUGGEDCOM i803RUGGEDCOM RSG910CRUGGEDCOM RSG2300PFRUGGEDCOM RSG2288 V4.XRUGGEDCOM RSG2488FRUGGEDCOM RS969RUGGEDCOM RSG2200RUGGEDCOM RS900 (32M) V4.XRUGGEDCOM RSG909RRUGGEDCOM RS416RUGGEDCOM RS416FRUGGEDCOM RS900GPFRUGGEDCOM RST2228PRUGGEDCOM RSG2100PRUGGEDCOM i800RUGGEDCOM RS416PRUGGEDCOM RS900M-STND-C01RUGGEDCOM RS900M-GETS-XXRUGGEDCOM RST916PRUGGEDCOM RSG920P V5.XRUGGEDCOM RSG2100 (32M) V4.XRUGGEDCOM RSG2288 V5.XRUGGEDCOM RS1600FRUGGEDCOM RSL910RUGGEDCOM RSG907RRUGGEDCOM RS930LRUGGEDCOM RSG2300P V5.XRUGGEDCOM RS910WRUGGEDCOM RSG2300 V5.XRUGGEDCOM RSG2100PFRUGGEDCOM RS900GPRUGGEDCOM RST916CRUGGEDCOM RSG2100FRUGGEDCOM RSG2488 V4.XRUGGEDCOM i802RUGGEDCOM RSG2100P (32M) V4.XRUGGEDCOM RS940GFRUGGEDCOM RSG2488 V5.XRUGGEDCOM RST2228RUGGEDCOM RS401RUGGEDCOM RMC30RUGGEDCOM RS900GFRUGGEDCOM M2100RUGGEDCOM RSG2300FRUGGEDCOM RS1600TRUGGEDCOM M969FRUGGEDCOM RS900G (32M) V5.XRUGGEDCOM RS416Pv2 V5.XRUGGEDCOM RS900M-GETS-C01RUGGEDCOM RS900 (32M) V5.XRUGGEDCOM M2200FRUGGEDCOM RP110RUGGEDCOM RSG2200FRUGGEDCOM i801RUGGEDCOM RSG2100P (32M) V5.XRUGGEDCOM RS416v2 V4.X
CWE ID-CWE-203
Observable Discrepancy
CWE ID-CWE-208
Observable Timing Discrepancy
CVE-2021-42018
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.9||MEDIUM
EPSS-0.60% / 68.47%
||
7 Day CHG~0.00%
Published-08 Mar, 2022 | 11:31
Updated-12 Aug, 2025 | 12:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i802, RUGGEDCOM i802NC, RUGGEDCOM i803, RUGGEDCOM i803NC, RUGGEDCOM M2100, RUGGEDCOM M2100F, RUGGEDCOM M2100NC, RUGGEDCOM M2200, RUGGEDCOM M2200F, RUGGEDCOM M2200NC, RUGGEDCOM M969, RUGGEDCOM M969F, RUGGEDCOM M969NC, RUGGEDCOM RMC30, RUGGEDCOM RMC30NC, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RMC8388NC V4.X, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RP110, RUGGEDCOM RP110NC, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600FNC, RUGGEDCOM RS1600NC, RUGGEDCOM RS1600T, RUGGEDCOM RS1600TNC, RUGGEDCOM RS400, RUGGEDCOM RS400F, RUGGEDCOM RS400NC, RUGGEDCOM RS401, RUGGEDCOM RS401NC, RUGGEDCOM RS416, RUGGEDCOM RS416F, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PF, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000ANC, RUGGEDCOM RS8000H, RUGGEDCOM RS8000HNC, RUGGEDCOM RS8000NC, RUGGEDCOM RS8000T, RUGGEDCOM RS8000TNC, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900F, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GF, RUGGEDCOM RS900GNC, RUGGEDCOM RS900GNC(32M) V4.X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPF, RUGGEDCOM RS900GPNC, RUGGEDCOM RS900L, RUGGEDCOM RS900LNC, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900MNC-GETS-C01, RUGGEDCOM RS900MNC-GETS-XX, RUGGEDCOM RS900MNC-STND-XX, RUGGEDCOM RS900MNC-STND-XX-C01, RUGGEDCOM RS900NC, RUGGEDCOM RS900NC(32M) V4.X, RUGGEDCOM RS900NC(32M) V5.X, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS910NC, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930LNC, RUGGEDCOM RS930W, RUGGEDCOM RS940G, RUGGEDCOM RS940GF, RUGGEDCOM RS940GNC, RUGGEDCOM RS969, RUGGEDCOM RS969NC, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100F, RUGGEDCOM RSG2100NC, RUGGEDCOM RSG2100NC(32M) V4.X, RUGGEDCOM RSG2100NC(32M) V5.X, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2100P (32M) V4.X, RUGGEDCOM RSG2100P (32M) V5.X, RUGGEDCOM RSG2100PF, RUGGEDCOM RSG2100PNC, RUGGEDCOM RSG2100PNC (32M) V4.X, RUGGEDCOM RSG2100PNC (32M) V5.X, RUGGEDCOM RSG2200, RUGGEDCOM RSG2200F, RUGGEDCOM RSG2200NC, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2288NC V4.X, RUGGEDCOM RSG2288NC V5.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300F, RUGGEDCOM RSG2300NC V4.X, RUGGEDCOM RSG2300NC V5.X, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PF, RUGGEDCOM RSG2300PNC V4.X, RUGGEDCOM RSG2300PNC V5.X, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488F, RUGGEDCOM RSG2488NC V4.X, RUGGEDCOM RSG2488NC V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V4.X, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSG920PNC V4.X, RUGGEDCOM RSG920PNC V5.X, RUGGEDCOM RSL910, RUGGEDCOM RSL910NC, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P. Within a third-party component, whenever memory allocation is requested, the out of bound size is not checked. Therefore, if size exceeding the expected allocation is assigned, it could allocate a smaller buffer instead. If an attacker were to exploit this, they could cause a heap overflow.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rs969ruggedcom_rs910ruggedcom_rsg2100ruggedcom_rsg2300pruggedcom_rs930lruggedcom_rsg907rruggedcom_rsg910cruggedcom_rs416ruggedcom_rs900wruggedcom_i801ruggedcom_rosruggedcom_m2100ruggedcom_rmcruggedcom_i800ruggedcom_rst2228ruggedcom_rs930wruggedcom_rmc8388ruggedcom_rsg2200ruggedcom_rs900ruggedcom_rs401ruggedcom_rs8000truggedcom_rsg909rruggedcom_rp110ruggedcom_rs910lruggedcom_i802ruggedcom_m969ruggedcom_rs910wruggedcom_rsg2100pruggedcom_rs8000ruggedcom_rst916pruggedcom_rs900gpruggedcom_rs900lruggedcom_rmc40ruggedcom_rsl910ruggedcom_rmc41ruggedcom_rsg920pruggedcom_rs920wruggedcom_rs416v2ruggedcom_rs8000aruggedcom_rsg2300ruggedcom_rst916cruggedcom_m2200ruggedcom_rs400ruggedcom_rst2228pruggedcom_rmc20ruggedcom_rs8000hruggedcom_rsg908cruggedcom_i803ruggedcom_rsg2488ruggedcom_rs900gruggedcom_rsg2288ruggedcom_rs920lruggedcom_rs940gruggedcom_rmc30RUGGEDCOM RS8000RUGGEDCOM RS900LRUGGEDCOM RSG2300 V4.XRUGGEDCOM RS900MNC-STND-XX-C01RUGGEDCOM RSG920P V4.XRUGGEDCOM RS401NCRUGGEDCOM RSG2100PNC (32M) V4.XRUGGEDCOM RS920LNCRUGGEDCOM RS910LRUGGEDCOM RS930WRUGGEDCOM RSG2100NC(32M) V5.XRUGGEDCOM RSG2100 (32M) V5.XRUGGEDCOM RSG2288NC V5.XRUGGEDCOM RS416Pv2 V4.XRUGGEDCOM RS1600RUGGEDCOM i801NCRUGGEDCOM RS940GRUGGEDCOM RSG2100NC(32M) V4.XRUGGEDCOM i800NCRUGGEDCOM RS910RUGGEDCOM RSG908CRUGGEDCOM RS8000NCRUGGEDCOM RS400FRUGGEDCOM RS900NC(32M) V4.XRUGGEDCOM RS920LRUGGEDCOM RMC8388 V4.XRUGGEDCOM RS8000HRUGGEDCOM RS900LNCRUGGEDCOM RS8000TRUGGEDCOM RS910NCRUGGEDCOM RS416PFRUGGEDCOM RS900GRUGGEDCOM M2100FRUGGEDCOM RS900M-STND-XXRUGGEDCOM RS900WRUGGEDCOM RMC8388 V5.XRUGGEDCOM RS900MNC-STND-XXRUGGEDCOM RSG2100PNC (32M) V5.XRUGGEDCOM RSG910CRUGGEDCOM RSG2300PFRUGGEDCOM RSG2288 V4.XRUGGEDCOM RS1600NCRUGGEDCOM RS969RUGGEDCOM RS900 (32M) V4.XRUGGEDCOM RSG909RRUGGEDCOM RS416FRUGGEDCOM RS900GPFRUGGEDCOM RSG2100PRUGGEDCOM RS930LNCRUGGEDCOM RS416PRUGGEDCOM RSG920P V5.XRUGGEDCOM RSG2200NCRUGGEDCOM RS8000HNCRUGGEDCOM RSG2300PNC V5.XRUGGEDCOM RSG2288 V5.XRUGGEDCOM RS1600FRUGGEDCOM RS416NCRUGGEDCOM RS930LRUGGEDCOM RSG907RRUGGEDCOM RSG2300P V5.XRUGGEDCOM RS910WRUGGEDCOM RSG2300 V5.XRUGGEDCOM RS940GNCRUGGEDCOM RS900GNCRUGGEDCOM RSG2100P (32M) V4.XRUGGEDCOM RMC8388NC V5.XRUGGEDCOM RS940GFRUGGEDCOM RS910LNCRUGGEDCOM RSG2288NC V4.XRUGGEDCOM RSG2488 V5.XRUGGEDCOM RMC30RUGGEDCOM RS900GFRUGGEDCOM RS8000ANCRUGGEDCOM RMC8388NC V4.XRUGGEDCOM RS1600TRUGGEDCOM M969FRUGGEDCOM RS900G (32M) V5.XRUGGEDCOM RS400NCRUGGEDCOM RS900MNC-GETS-C01RUGGEDCOM RS900M-GETS-C01RUGGEDCOM RSG2488NC V4.XRUGGEDCOM M2200FRUGGEDCOM RP110RUGGEDCOM i801RUGGEDCOM RS416v2 V4.XRUGGEDCOM RS416NCv2 V4.XRUGGEDCOM RS8000TNCRUGGEDCOM RSG2300P V4.XRUGGEDCOM RS416v2 V5.XRUGGEDCOM RS920WRUGGEDCOM RS900FRUGGEDCOM M2200RUGGEDCOM RS900MNC-GETS-XXRUGGEDCOM RSG2300NC V5.XRUGGEDCOM RS900GNC(32M) V4.XRUGGEDCOM RS900RUGGEDCOM RSG2100RUGGEDCOM M969NCRUGGEDCOM RS416PNCRUGGEDCOM RS1600FNCRUGGEDCOM RS400RUGGEDCOM RS900NC(32M) V5.XRUGGEDCOM RS1600TNCRUGGEDCOM RS900G (32M) V4.XRUGGEDCOM M969RUGGEDCOM RS416PNCv2 V4.XRUGGEDCOM M2200NCRUGGEDCOM RS8000ARUGGEDCOM i803RUGGEDCOM RSG2100PNCRUGGEDCOM RSG920PNC V5.XRUGGEDCOM RSG2100NCRUGGEDCOM RSG2488FRUGGEDCOM RP110NCRUGGEDCOM RSG2200RUGGEDCOM RSG2488NC V5.XRUGGEDCOM RSL910NCRUGGEDCOM RS969NCRUGGEDCOM RS416RUGGEDCOM RST2228PRUGGEDCOM i800RUGGEDCOM RS900M-STND-C01RUGGEDCOM RS900M-GETS-XXRUGGEDCOM RST916PRUGGEDCOM RS416PNCv2 V5.XRUGGEDCOM RS416NCv2 V5.XRUGGEDCOM RSG2100 (32M) V4.XRUGGEDCOM RSL910RUGGEDCOM RSG2100PFRUGGEDCOM RS900GPRUGGEDCOM RST916CRUGGEDCOM RS900GPNCRUGGEDCOM RSG2100FRUGGEDCOM RSG2488 V4.XRUGGEDCOM i802RUGGEDCOM RS900GNC(32M) V5.XRUGGEDCOM RST2228RUGGEDCOM RS401RUGGEDCOM RSG2300NC V4.XRUGGEDCOM RSG920PNC V4.XRUGGEDCOM i802NCRUGGEDCOM i803NCRUGGEDCOM M2100RUGGEDCOM RSG2300FRUGGEDCOM RSG2300PNC V4.XRUGGEDCOM RS900NCRUGGEDCOM RS416Pv2 V5.XRUGGEDCOM RMC30NCRUGGEDCOM RS900 (32M) V5.XRUGGEDCOM RSG2200FRUGGEDCOM M2100NCRUGGEDCOM RSG2100P (32M) V5.X
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-41769
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.47% / 63.79%
||
7 Day CHG~0.00%
Published-11 Jan, 2022 | 11:27
Updated-04 Aug, 2024 | 03:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIPROTEC 5 6MD85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MD86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MD89 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MU85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7KE85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SA82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SA86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SA87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SD82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SD86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SD87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SJ81 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SJ82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SJ85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SJ86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SK82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SK85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SL82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SL86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SL87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SS85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7ST85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SX85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UM85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7UT85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7VE85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7VK87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 Compact 7SX800 devices (CPU variant CP050) (All versions < V8.83). An improper input validation vulnerability in the web server could allow an unauthenticated user to access device information.

Action-Not Available
Vendor-Siemens AG
Product-6md857sa87_firmware6md867um856md89_firmware7sl87_firmware7sk85_firmware7ut867ss857sa877ke85_firmware7sd87_firmware6mu85_firmware6md896mu857st857vk877sd86_firmware7sl82_firmware7ut857sj81_firmware7ve85_firmware7st85_firmware7sl827sd867ke857sa86_firmware7sx8007ut86_firmware6md85_firmware7sk857sk827sx800_firmware7sd877sx85_firmware6md86_firmware7sk82_firmware7sa867sj827sj857sj86_firmware7sl86_firmware7sj817ut82_firmware7ut85_firmware7sj82_firmware7um85_firmware7ve857ut877vk87_firmware7sa827sj85_firmware7sl867sx857sd827ut87_firmware7ut827sj867sd82_firmware7sl877sa82_firmware7ss85_firmwareSIPROTEC 5 7SD82 devices (CPU variant CP100)SIPROTEC 5 6MD86 devices (CPU variant CP300)SIPROTEC 5 7VE85 devices (CPU variant CP300)SIPROTEC 5 7UT87 devices (CPU variant CP300)SIPROTEC 5 7ST85 devices (CPU variant CP300)SIPROTEC 5 7SL82 devices (CPU variant CP100)SIPROTEC 5 7UT82 devices (CPU variant CP100)SIPROTEC 5 6MU85 devices (CPU variant CP300)SIPROTEC 5 7SK82 devices (CPU variant CP100)SIPROTEC 5 7SK85 devices (CPU variant CP300)SIPROTEC 5 7UT86 devices (CPU variant CP300)SIPROTEC 5 7SA82 devices (CPU variant CP100)SIPROTEC 5 7VK87 devices (CPU variant CP300)SIPROTEC 5 7SD86 devices (CPU variant CP300)SIPROTEC 5 7SJ85 devices (CPU variant CP300)SIPROTEC 5 7SJ82 devices (CPU variant CP100)SIPROTEC 5 7SL87 devices (CPU variant CP300)SIPROTEC 5 7SX85 devices (CPU variant CP300)SIPROTEC 5 Compact 7SX800 devices (CPU variant CP050)SIPROTEC 5 6MD85 devices (CPU variant CP300)SIPROTEC 5 7UM85 devices (CPU variant CP300)SIPROTEC 5 7SA86 devices (CPU variant CP300)SIPROTEC 5 7UT85 devices (CPU variant CP300)SIPROTEC 5 7SL86 devices (CPU variant CP300)SIPROTEC 5 7KE85 devices (CPU variant CP300)SIPROTEC 5 7SJ86 devices (CPU variant CP300)SIPROTEC 5 7SS85 devices (CPU variant CP300)SIPROTEC 5 7SD87 devices (CPU variant CP300)SIPROTEC 5 7SA87 devices (CPU variant CP300)SIPROTEC 5 6MD89 devices (CPU variant CP300)SIPROTEC 5 7SJ81 devices (CPU variant CP100)
CWE ID-CWE-20
Improper Input Validation
CVE-2019-5319
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.8||CRITICAL
EPSS-1.74% / 81.72%
||
7 Day CHG~0.00%
Published-30 Mar, 2021 | 01:45
Updated-04 Aug, 2024 | 19:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote buffer overflow vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.16 and below; Aruba Instant 8.3.x: 8.3.0.12 and below; Aruba Instant 8.5.x: 8.5.0.6 and below; Aruba Instant 8.6.x: 8.6.0.2 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-scalance_w1750d_firmwareinstantscalance_w1750dAruba Instant Access Points
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2020-11656
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-9.40% / 92.47%
||
7 Day CHG~0.00%
Published-09 Apr, 2020 | 02:49
Updated-04 Aug, 2024 | 11:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In SQLite through 3.31.1, the ALTER TABLE implementation has a use-after-free, as demonstrated by an ORDER BY clause that belongs to a compound SELECT statement.

Action-Not Available
Vendor-sqliten/aNetApp, Inc.Oracle CorporationTenable, Inc.Siemens AG
Product-sinec_infrastructure_network_servicescommunications_messaging_serverontap_select_deploy_administration_utilitysqlitecommunications_network_charging_and_controlzfs_storage_appliance_kitoutside_in_technologytenable.schyperion_infrastructure_technologymysql_workbenchenterprise_manager_ops_centermysqln/a
CWE ID-CWE-416
Use After Free
CVE-2021-37726
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.8||CRITICAL
EPSS-1.32% / 79.04%
||
7 Day CHG~0.00%
Published-12 Oct, 2021 | 14:06
Updated-04 Aug, 2024 | 01:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote buffer overflow vulnerability was discovered in HPE Aruba Instant (IAP) version(s): Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-aruba_instantscalance_w1750d_firmwarescalance_w1750dHPE Aruba Instant (IAP)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2019-19646
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-21.53% / 95.50%
||
7 Day CHG~0.00%
Published-09 Dec, 2019 | 18:36
Updated-05 Aug, 2024 | 02:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

pragma.c in SQLite through 3.30.1 mishandles NOT NULL in an integrity_check PRAGMA command in certain cases of generated columns.

Action-Not Available
Vendor-sqliten/aNetApp, Inc.Oracle CorporationTenable, Inc.Siemens AG
Product-sinec_infrastructure_network_servicescloud_backupsqliteontap_select_deploy_administration_utilitytenable.scmysql_workbenchn/a
CWE ID-CWE-754
Improper Check for Unusual or Exceptional Conditions
CVE-2021-37175
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.23%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). The affected devices do not properly handle permissions to traverse the file system. If exploited, an attacker could gain access to an overview of the complete file system on the affected devices.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rox_rx1511ruggedcom_rox_rx1512ruggedcom_rox_mx5000_firmwareruggedcom_rox_rx5000_firmwareruggedcom_rox_rx1511_firmwareruggedcom_rox_rx1510ruggedcom_rox_rx1400_firmwareruggedcom_rox_rx1500_firmwareruggedcom_rox_rx1400ruggedcom_rox_rx1510_firmwareruggedcom_rox_rx1500ruggedcom_rox_rx1524_firmwareruggedcom_rox_rx5000ruggedcom_rox_rx1501ruggedcom_rox_rx1536ruggedcom_rox_mx5000ruggedcom_rox_rx1524ruggedcom_rox_rx1536_firmwareruggedcom_rox_rx1501_firmwareruggedcom_rox_rx1512_firmwareRUGGEDCOM ROX RX1511RUGGEDCOM ROX RX1536RUGGEDCOM ROX RX1400RUGGEDCOM ROX RX1500RUGGEDCOM ROX RX1501RUGGEDCOM ROX RX5000RUGGEDCOM ROX MX5000RUGGEDCOM ROX RX1524RUGGEDCOM ROX RX1510RUGGEDCOM ROX RX1512
CWE ID-CWE-280
Improper Handling of Insufficient Permissions or Privileges
CWE ID-CWE-755
Improper Handling of Exceptional Conditions
CVE-2017-14491
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-52.38% / 97.83%
||
7 Day CHG~0.00%
Published-02 Oct, 2017 | 21:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Heap-based buffer overflow in dnsmasq before 2.78 allows remote attackers to cause a denial of service (crash) or execute arbitrary code via a crafted DNS response.

Action-Not Available
Vendor-thekelleysn/aHuawei Technologies Co., Ltd.Debian GNU/LinuxSUSERed Hat, Inc.Aruba NetworksSynology, Inc.NVIDIA CorporationArista Networks, Inc.Canonical Ltd.openSUSEMicrosoft CorporationSiemens AG
Product-enterprise_linux_desktopruggedcom_rm1224_firmwarescalance_w1750d_firmwarescalance_s615enterprise_linux_workstationlinux_for_tegradnsmasqlinux_enterprise_serverleaprouter_managerlinux_enterprise_point_of_salearubaosenterprise_linux_serverdebian_linuxjetson_tk1scalance_s615_firmwaregeforce_experiencelinux_enterprise_debuginfoeosscalance_m-800diskstation_managerhonor_v9_play_firmwarejetson_tx1scalance_w1750druggedcom_rm1224ubuntu_linuxhonor_v9_playscalance_m-800_firmwarewindowsn/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2012-3030
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-5||MEDIUM
EPSS-0.52% / 65.75%
||
7 Day CHG~0.00%
Published-18 Sep, 2012 | 14:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.

Action-Not Available
Vendor-n/aSiemens AG
Product-winccsimatic_pcs7n/a
CVE-2024-38879
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.20% / 42.69%
||
7 Day CHG~0.00%
Published-02 Aug, 2024 | 10:36
Updated-20 Sep, 2024 | 23:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Omnivise T3000 Application Server R9.2 (All versions), Omnivise T3000 R8.2 SP3 (All versions), Omnivise T3000 R8.2 SP4 (All versions). The affected system exposes the port of an internal application on the public network interface allowing an attacker to circumvent authentication and directly access the exposed application.

Action-Not Available
Vendor-Siemens AG
Product-omnivise_t3000_application_serverOmnivise T3000 Application Server R9.2Omnivise T3000 R8.2 SP3Omnivise T3000 R8.2 SP4omnivise_t3000_application_serveromnivise_t3000
CWE ID-CWE-20
Improper Input Validation
CVE-2024-37998
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.3||CRITICAL
EPSS-0.20% / 42.01%
||
7 Day CHG~0.00%
Published-22 Jul, 2024 | 13:54
Updated-02 Aug, 2024 | 04:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.40), SICORE Base system (All versions < V1.4.0). The password of administrative accounts of the affected applications can be reset without requiring the knowledge of the current password, given the auto login is enabled. This could allow an unauthorized attacker to obtain administrative access of the affected applications.

Action-Not Available
Vendor-Siemens AG
Product-CPCI85 Central Processing/CommunicationSICORE Base systemcpci85_firmwaresicore_base_system
CWE ID-CWE-620
Unverified Password Change
CVE-2021-33711
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.69%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter Active Workspace V4 (All versions < V4.3.9), Teamcenter Active Workspace V5.0 (All versions < V5.0.7), Teamcenter Active Workspace V5.1 (All versions < V5.1.4). The affected application allows verbose error messages which allow leaking of sensitive information, such as full paths.

Action-Not Available
Vendor-Siemens AG
Product-teamcenter_active_workspaceTeamcenter Active Workspace V4Teamcenter Active Workspace V5.0Teamcenter Active Workspace V5.1
CWE ID-CWE-209
Generation of Error Message Containing Sensitive Information
CVE-2021-33719
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.56% / 67.13%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Specially crafted packets sent to port 4443/tcp could cause a Denial-of-Service condition or potential remote code execution.

Action-Not Available
Vendor-Siemens AG
Product-siprotec_5_with_cpu_variant_cp300siprotec_5_with_cpu_variant_cp100siprotec_5_with_cpu_variant_cp050SIPROTEC 5 relays with CPU variants CP050SIPROTEC 5 relays with CPU variants CP300SIPROTEC 5 relays with CPU variants CP100
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2021-31885
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.39% / 58.95%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:31
Updated-03 Aug, 2024 | 23:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)

Action-Not Available
Vendor-Siemens AG
Product-nucleus_readystart_v3talon_tc_compactnucleus_nettalon_tc_compact_firmwareapogee_pxc_compactapogee_modular_equiment_controller_firmwareapogee_pxc_compact_firmwareapogee_modular_equiment_controllerapogee_modular_building_controllercapital_vstarapogee_pxc_modular_firmwareapogee_pxc_modularnucleus_readystart_v4talon_tc_modular_firmwaretalon_tc_modularapogee_modular_building_controller_firmwarenucleus_source_codeTALON TC Compact (BACnet)Desigo PXC64-UDesigo PXC00-UNucleus Source CodeAPOGEE PXC Compact (BACnet)APOGEE MEC (PPC) (P2 Ethernet)Nucleus NETDesigo PXC001-E.DDesigo PXC100-E.DDesigo PXC12-E.DAPOGEE MBC (PPC) (BACnet)Desigo PXC22.1-E.DTALON TC Modular (BACnet)Nucleus ReadyStart V3APOGEE MEC (PPC) (BACnet)Desigo PXC00-E.DNucleus ReadyStart V4APOGEE MBC (PPC) (P2 Ethernet)Desigo PXC50-E.DAPOGEE PXC Compact (P2 Ethernet)PLUSCONTROL 1st GenDesigo PXC36.1-E.DAPOGEE PXC Modular (P2 Ethernet)Desigo PXC22-E.DDesigo PXC200-E.DDesigo PXM20-EAPOGEE PXC Modular (BACnet)Desigo PXC128-U
CWE ID-CWE-805
Buffer Access with Incorrect Length Value
CVE-2021-31886
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-2.90% / 85.82%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:31
Updated-03 Aug, 2024 | 23:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “USER” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)

Action-Not Available
Vendor-Siemens AG
Product-talon_tc_compactdesigo_pxm20-edesigo_pxc22.1-e.dapogee_pxc_compactdesigo_pxc001-e.d_firmwareapogee_modular_equiment_controller_firmwaredesigo_pxc12-e.dapogee_pxc_compact_firmwaredesigo_pxc200-e.d_firmwareapogee_modular_equiment_controllerdesigo_pxc100-e.dapogee_modular_building_controllerdesigo_pxc001-e.dapogee_pxc_modular_firmwaretalon_tc_modular_firmwaretalon_tc_modulardesigo_pxc22.1-e.d_firmwaredesigo_pxc50-e.dapogee_modular_building_controller_firmwaredesigo_pxc12-e.d_firmwaredesigo_pxc22-e.ddesigo_pxc22-e.d_firmwaredesigo_pxc00-u_firmwarenucleus_readystart_v3desigo_pxc00-e.ddesigo_pxc100-e.d_firmwaredesigo_pxc200-e.ddesigo_pxc00-e.d_firmwaredesigo_pxc50-e.d_firmwarenucleus_netdesigo_pxc64-utalon_tc_compact_firmwaredesigo_pxc36.1-e.d_firmwaredesigo_pxc64-u_firmwaredesigo_pxc128-udesigo_pxc00-uapogee_pxc_modulardesigo_pxm20-e_firmwaredesigo_pxc36.1-e.ddesigo_pxc128-u_firmwarenucleus_source_codeTALON TC Compact (BACnet)Desigo PXC64-UDesigo PXC00-UNucleus Source CodeAPOGEE PXC Compact (BACnet)APOGEE MEC (PPC) (P2 Ethernet)Nucleus NETDesigo PXC001-E.DDesigo PXC100-E.DDesigo PXC12-E.DAPOGEE MBC (PPC) (BACnet)Desigo PXC22.1-E.DTALON TC Modular (BACnet)Nucleus ReadyStart V3APOGEE MEC (PPC) (BACnet)Desigo PXC00-E.DAPOGEE MBC (PPC) (P2 Ethernet)Desigo PXC50-E.DAPOGEE PXC Compact (P2 Ethernet)Desigo PXC36.1-E.DAPOGEE PXC Modular (P2 Ethernet)Desigo PXC22-E.DDesigo PXC200-E.DDesigo PXM20-EAPOGEE PXC Modular (BACnet)Desigo PXC128-U
CWE ID-CWE-170
Improper Null Termination
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-31895
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.1||HIGH
EPSS-2.33% / 84.19%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:02
Updated-13 May, 2025 | 10:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM i800 (All versions < V4.3.7), RUGGEDCOM i801 (All versions < V4.3.7), RUGGEDCOM i802 (All versions < V4.3.7), RUGGEDCOM i803 (All versions < V4.3.7), RUGGEDCOM M2100 (All versions < V4.3.7), RUGGEDCOM M2200 (All versions < V4.3.7), RUGGEDCOM M969 (All versions < V4.3.7), RUGGEDCOM RMC30 (All versions < V4.3.7), RUGGEDCOM RMC8388 V4.X (All versions < V4.3.7), RUGGEDCOM RMC8388 V5.X (All versions < V5.5.4), RUGGEDCOM RP110 (All versions < V4.3.7), RUGGEDCOM RS1600 (All versions < V4.3.7), RUGGEDCOM RS1600F (All versions < V4.3.7), RUGGEDCOM RS1600T (All versions < V4.3.7), RUGGEDCOM RS400 (All versions < V4.3.7), RUGGEDCOM RS401 (All versions < V4.3.7), RUGGEDCOM RS416 (All versions < V4.3.7), RUGGEDCOM RS416P (All versions < V4.3.7), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.7), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.5.4), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.7), RUGGEDCOM RS416v2 V5.X (All versions < 5.5.4), RUGGEDCOM RS8000 (All versions < V4.3.7), RUGGEDCOM RS8000A (All versions < V4.3.7), RUGGEDCOM RS8000H (All versions < V4.3.7), RUGGEDCOM RS8000T (All versions < V4.3.7), RUGGEDCOM RS900 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RS900G (All versions < V4.3.7), RUGGEDCOM RS900G (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RS900GP (All versions < V4.3.7), RUGGEDCOM RS900L (All versions < V4.3.7), RUGGEDCOM RS900W (All versions < V4.3.7), RUGGEDCOM RS910 (All versions < V4.3.7), RUGGEDCOM RS910L (All versions < V4.3.7), RUGGEDCOM RS910W (All versions < V4.3.7), RUGGEDCOM RS920L (All versions < V4.3.7), RUGGEDCOM RS920W (All versions < V4.3.7), RUGGEDCOM RS930L (All versions < V4.3.7), RUGGEDCOM RS930W (All versions < V4.3.7), RUGGEDCOM RS940G (All versions < V4.3.7), RUGGEDCOM RS969 (All versions < V4.3.7), RUGGEDCOM RSG2100 (All versions), RUGGEDCOM RSG2100 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RSG2100P (All versions < V4.3.7), RUGGEDCOM RSG2100P (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RSG2100PNC (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RSG2100PNC (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RSG2200 (All versions < V4.3.7), RUGGEDCOM RSG2288 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2288 V5.X (All versions < V5.5.4), RUGGEDCOM RSG2300 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2300 V5.X (All versions < V5.5.4), RUGGEDCOM RSG2300P V4.X (All versions < V4.3.7), RUGGEDCOM RSG2300P V5.X (All versions < V5.5.4), RUGGEDCOM RSG2488 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2488 V5.X (All versions < V5.5.4), RUGGEDCOM RSG907R (All versions < V5.5.4), RUGGEDCOM RSG908C (All versions < V5.5.4), RUGGEDCOM RSG909R (All versions < V5.5.4), RUGGEDCOM RSG910C (All versions < V5.5.4), RUGGEDCOM RSG920P V4.X (All versions < V4.3.7), RUGGEDCOM RSG920P V5.X (All versions < V5.5.4), RUGGEDCOM RSL910 (All versions < V5.5.4), RUGGEDCOM RST2228 (All versions < V5.5.4), RUGGEDCOM RST2228P (All versions < V5.5.4), RUGGEDCOM RST916C (All versions < V5.5.4), RUGGEDCOM RST916P (All versions < V5.5.4). The DHCP client in affected devices fails to properly sanitize incoming DHCP packets. This could allow an unauthenticated remote attacker to cause memory to be overwritten, potentially allowing remote code execution.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_ros_rmc20ruggedcom_ros_rsg2100ruggedcom_rs8000ruggedcom_rs910ruggedcom_rsg900ruggedcom_ros_rs900gpruggedcom_ros_i800ruggedcom_ros_rs8000ruggedcom_rs900gruggedcom_rsg900cruggedcom_rsg2300ruggedcom_ros_rs401ruggedcom_ros_i801ruggedcom_ros_rmc30ruggedcom_rp110ruggedcom_rsg900gruggedcom_rst2228ruggedcom_rs900gpruggedcom_ros_rs920wruggedcom_rsg2200ruggedcom_ros_rmc40ruggedcom_rs910wruggedcom_rsg2488ruggedcom_rst916pruggedcom_m2200ruggedcom_ros_rs416ruggedcom_rs920lruggedcom_rsg2100ruggedcom_rs8000aruggedcom_ros_m969ruggedcom_rsg920pruggedcom_rmc40ruggedcom_rs900lruggedcom_ros_rsg2100pruggedcom_rmc20ruggedcom_ros_rs969ruggedcom_ros_rs910lruggedcom_ros_rsg2288ruggedcom_rsg900rruggedcom_ros_i802ruggedcom_rmcruggedcom_rs401ruggedcom_ros_rs900wruggedcom_ros_rsg900cruggedcom_rs900ruggedcom_rs930lruggedcom_rs920wruggedcom_ros_i803ruggedcom_ros_rmc8388ruggedcom_rs416ruggedcom_ros_rs8000truggedcom_ros_rs900ruggedcom_ros_rsg900rruggedcom_ros_rst2228ruggedcom_rs930wruggedcom_ros_rs910wruggedcom_ros_rs900gruggedcom_ros_rsg2300ruggedcom_ros_rs416v2ruggedcom_rsg2300pruggedcom_rmc30ruggedcom_ros_rsg900gruggedcom_rs969ruggedcom_ros_rs940gruggedcom_rs416v2ruggedcom_i803ruggedcom_ros_rs900lruggedcom_i802ruggedcom_ros_rs8000hruggedcom_rs8000hruggedcom_rs400ruggedcom_ros_rsg920pruggedcom_rs940gruggedcom_i801ruggedcom_ros_rsl910ruggedcom_rs8000truggedcom_ros_rst916pruggedcom_rsl910ruggedcom_ros_rp110ruggedcom_ros_rsg2300pruggedcom_ros_rs910ruggedcom_ros_rst916cruggedcom_ros_rs400ruggedcom_rsg2288ruggedcom_m2100ruggedcom_ros_rs930lruggedcom_ros_m2100ruggedcom_rst916cruggedcom_ros_m2200ruggedcom_ros_rsg2200ruggedcom_ros_rmc41ruggedcom_rs900wruggedcom_ros_rs8000aruggedcom_m969ruggedcom_ros_rsg900ruggedcom_ros_rs920lruggedcom_rmc41ruggedcom_ros_rmcruggedcom_rmc8388ruggedcom_ros_rsg2488ruggedcom_rsg2100pruggedcom_i800ruggedcom_rs910lruggedcom_ros_rs930wRUGGEDCOM RS910WRUGGEDCOM M969RUGGEDCOM RS1600FRUGGEDCOM RS900 (32M) V5.XRUGGEDCOM RSL910RUGGEDCOM RSG2300 V5.XRUGGEDCOM RS400RUGGEDCOM RST2228RUGGEDCOM i803RUGGEDCOM RSG920P V4.XRUGGEDCOM RS416v2 V5.XRUGGEDCOM RMC30RUGGEDCOM i800RUGGEDCOM RMC8388 V5.XRUGGEDCOM RS910LRUGGEDCOM RS900G (32M) V5.XRUGGEDCOM RSG2100PNC (32M) V5.XRUGGEDCOM RS930WRUGGEDCOM RS969RUGGEDCOM i802RUGGEDCOM RS1600RUGGEDCOM RSG2288 V5.XRUGGEDCOM RS900GRUGGEDCOM RS416v2 V4.XRUGGEDCOM RS920WRUGGEDCOM RSG2100 (32M) V4.XRUGGEDCOM RSG2100PRUGGEDCOM RSG2100P (32M) V5.XRUGGEDCOM RMC8388 V4.XRUGGEDCOM RP110RUGGEDCOM RSG2100RUGGEDCOM RS8000ARUGGEDCOM RS900WRUGGEDCOM RSG2200RUGGEDCOM M2200RUGGEDCOM RS940GRUGGEDCOM RSG2300P V4.XRUGGEDCOM RSG2300 V4.XRUGGEDCOM RS8000TRUGGEDCOM RS900G (32M) V4.XRUGGEDCOM RST2228PRUGGEDCOM RSG908CRUGGEDCOM RS416Pv2 V5.XRUGGEDCOM RS900GPRUGGEDCOM RSG2300P V5.XRUGGEDCOM RST916PRUGGEDCOM RS920LRUGGEDCOM RS900LRUGGEDCOM RS416Pv2 V4.XRUGGEDCOM RS1600TRUGGEDCOM RS8000RUGGEDCOM RS401RUGGEDCOM RS900 (32M) V4.XRUGGEDCOM RST916CRUGGEDCOM RSG2488 V5.XRUGGEDCOM RSG2488 V4.XRUGGEDCOM i801RUGGEDCOM RS930LRUGGEDCOM RSG2100 (32M) V5.XRUGGEDCOM RSG909RRUGGEDCOM RSG920P V5.XRUGGEDCOM RS910RUGGEDCOM M2100RUGGEDCOM RSG907RRUGGEDCOM RS416RUGGEDCOM RS416PRUGGEDCOM RSG2100PNC (32M) V4.XRUGGEDCOM RS8000HRUGGEDCOM RSG2288 V4.XRUGGEDCOM RSG910CRUGGEDCOM RSG2100P (32M) V4.X
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-31884
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.73% / 71.67%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:31
Updated-03 Aug, 2024 | 23:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The DHCP client application assumes that the data supplied with the “Hostname” DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014)

Action-Not Available
Vendor-Siemens AG
Product-talon_tc_compactdesigo_pxm20-edesigo_pxc22.1-e.dapogee_pxc_compactdesigo_pxc001-e.d_firmwareapogee_modular_equiment_controller_firmwaredesigo_pxc12-e.dapogee_pxc_compact_firmwaredesigo_pxc200-e.d_firmwareapogee_modular_equiment_controllerdesigo_pxc100-e.dapogee_modular_building_controllerdesigo_pxc001-e.dapogee_pxc_modular_firmwaretalon_tc_modular_firmwaretalon_tc_modulardesigo_pxc22.1-e.d_firmwaredesigo_pxc50-e.dapogee_modular_building_controller_firmwaredesigo_pxc12-e.d_firmwaredesigo_pxc22-e.ddesigo_pxc22-e.d_firmwaredesigo_pxc00-u_firmwarenucleus_readystart_v3desigo_pxc00-e.ddesigo_pxc100-e.d_firmwaredesigo_pxc200-e.ddesigo_pxc00-e.d_firmwaredesigo_pxc50-e.d_firmwarenucleus_netdesigo_pxc64-utalon_tc_compact_firmwaredesigo_pxc36.1-e.d_firmwaredesigo_pxc64-u_firmwaredesigo_pxc128-ucapital_vstardesigo_pxc00-uapogee_pxc_modulardesigo_pxm20-e_firmwaredesigo_pxc36.1-e.ddesigo_pxc128-u_firmwarenucleus_source_codeTALON TC Compact (BACnet)Desigo PXC64-UDesigo PXC00-UNucleus Source CodeAPOGEE PXC Compact (BACnet)APOGEE MEC (PPC) (P2 Ethernet)Nucleus NETDesigo PXC001-E.DDesigo PXC100-E.DDesigo PXC12-E.DAPOGEE MBC (PPC) (BACnet)Desigo PXC22.1-E.DTALON TC Modular (BACnet)Nucleus ReadyStart V3APOGEE MEC (PPC) (BACnet)Desigo PXC00-E.DAPOGEE MBC (PPC) (P2 Ethernet)Desigo PXC50-E.DAPOGEE PXC Compact (P2 Ethernet)Desigo PXC36.1-E.DAPOGEE PXC Modular (P2 Ethernet)Capital VSTARDesigo PXC22-E.DDesigo PXC200-E.DDesigo PXM20-EAPOGEE PXC Modular (BACnet)Desigo PXC128-U
CWE ID-CWE-170
Improper Null Termination
CVE-2024-47901
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-10||CRITICAL
EPSS-2.84% / 85.66%
||
7 Day CHG~0.00%
Published-23 Oct, 2024 | 14:21
Updated-30 Oct, 2024 | 15:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not sanitize the input parameters in specific GET requests that allow for code execution on operating system level. In combination with other vulnerabilities (CVE-2024-47902, CVE-2024-47903, CVE-2024-47904) this could allow an unauthenticated remote attacker to execute arbitrary code with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-intermesh_7707_fire_subscriberintermesh_7177_hybrid_2.0_subscriberintermesh_7707_fire_subscriber_firmwareInterMesh 7707 Fire SubscriberInterMesh 7177 Hybrid 2.0 Subscriberintermesh_7177_hybrid2.0_subscriberintermesh_7707_fire_subscriber
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-33698
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.3||CRITICAL
EPSS-0.96% / 75.57%
||
7 Day CHG~0.00%
Published-10 Sep, 2024 | 09:36
Updated-11 Mar, 2025 | 10:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Opcenter Execution Foundation (All versions), Opcenter Quality (All versions), Opcenter RDL (All versions), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.

Action-Not Available
Vendor-Siemens AG
Product-Opcenter RDLSINEMA Remote Connect ClientTotally Integrated Automation Portal (TIA Portal) V16Totally Integrated Automation Portal (TIA Portal) V17Opcenter Execution FoundationTotally Integrated Automation Portal (TIA Portal) V18Totally Integrated Automation Portal (TIA Portal) V19SIMATIC PCS neo V5.0SINEC NMSSIMATIC PCS neo V4.0Opcenter QualitySIMATIC PCS neo V4.1totally_integrated_automation_portalsimatic_pcs_neosimatic_information_server
CWE ID-CWE-122
Heap-based Buffer Overflow
CVE-2024-47902
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.9||MEDIUM
EPSS-0.14% / 34.88%
||
7 Day CHG~0.00%
Published-23 Oct, 2024 | 14:21
Updated-30 Oct, 2024 | 15:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not authenticate GET requests that execute specific commands (such as `ping`) on operating system level.

Action-Not Available
Vendor-Siemens AG
Product-intermesh_7707_fire_subscriberintermesh_7177_hybrid_2.0_subscriberintermesh_7707_fire_subscriber_firmwareInterMesh 7707 Fire SubscriberInterMesh 7177 Hybrid 2.0 Subscriberintermesh_7177_hybrid2.0_subscriberintermesh_7707_fire_subscriber
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2021-27384
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.43% / 79.88%
||
7 Day CHG~0.00%
Published-12 May, 2021 | 13:18
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.

Action-Not Available
Vendor-Siemens AG
Product-simatic_hmi_ktp_mobile_panels_ktp900_firmwaresimatic_hmi_ktp_mobile_panels_ktp400fsinamics_gm150simatic_hmi_ktp_mobile_panels_ktp700f_firmwaresinamics_sm150isinamics_gl150_firmwaresinamics_gl150simatic_hmi_ktp_mobile_panels_ktp900f_firmwaresimatic_hmi_ktp_mobile_panels_ktp400f_firmwaresimatic_hmi_comfort_panels_4\"_firmwaresinamics_gm150_firmwaresinamics_sm150simatic_hmi_comfort_outdoor_panels_7\"_firmwaresinamics_gh150simatic_hmi_ktp_mobile_panels_ktp700_firmwaresinamics_gh150_firmwaresinamics_sl150simatic_hmi_comfort_panels_22\"simatic_hmi_ktp_mobile_panels_ktp700fsinamics_sh150sinamics_sm150_firmwaresimatic_hmi_ktp_mobile_panels_ktp900fsinamics_sh150_firmwaresimatic_hmi_comfort_outdoor_panels_7\"sinamics_sm120simatic_hmi_ktp_mobile_panels_ktp700simatic_hmi_comfort_outdoor_panels_15\"_firmwaresimatic_hmi_comfort_panels_4\"sinamics_sl150_firmwaresinamics_sm150i_firmwaresimatic_hmi_ktp_mobile_panels_ktp900simatic_hmi_comfort_outdoor_panels_15\"simatic_hmi_comfort_panels_22\"_firmwaresimatic_wincc_runtime_advancedsinamics_sm120_firmwareSIMATIC WinCC Runtime Advanced V16SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants)SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) SINAMICS SM150iSIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants)SINAMICS GH150SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900FSINAMICS GM150 (with option X30)SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F SINAMICS GL150 (with option X30)SINAMICS SH150SIMATIC WinCC Runtime Advanced V15SINAMICS SL150SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) SINAMICS SM120SINAMICS SM150
CWE ID-CWE-788
Access of Memory Location After End of Buffer
CVE-2021-27391
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-2.86% / 85.72%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-23 Apr, 2025 | 19:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in APOGEE MBC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE MEC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE PXC Compact (BACnet) (All versions < V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions >= V2.8), APOGEE PXC Modular (BACnet) (All versions < V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions >= V2.8), TALON TC Compact (BACnet) (All versions < V3.5.3), TALON TC Modular (BACnet) (All versions < V3.5.3). The web server of affected devices lacks proper bounds checking when parsing the Host parameter in HTTP requests, which could lead to a buffer overflow. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the device with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-apogee_pxc_compact_\(p2_ethernet\)apogee_pxc_modular_\(bacnet\)_firmwareapogee_pxc_compact_\(p2_ethernet\)_firmwaretalon_tc_compact_\(bacnet\)apogee_mbc_\(ppc\)_\(p2_ethernet\)_firmwareapogee_pxc_bacnet_automation_controllerapogee_mbc_\(ppc\)_\(p2_ethernet\)apogee_pxc_bacnet_automation_controller_firmwareapogee_mec_\(ppc\)_\(p2_ethernet\)talon_tc_compact_\(bacnet\)_firmwareapogee_pxc_modular_\(p2_ethernet\)talon_tc_modular_\(bacnet\)apogee_pxc_modular_\(p2_ethernet\)_firmwareapogee_pxc_modular_\(bacnet\)apogee_mec_\(ppc\)_\(p2_ethernet\)_firmwaretalon_tc_modular_\(bacnet\)_firmwareAPOGEE PXC Modular (P2 Ethernet)APOGEE PXC Compact (BACnet)APOGEE MEC (PPC) (P2 Ethernet)APOGEE PXC Modular (BACnet)APOGEE MBC (PPC) (P2 Ethernet)TALON TC Modular (BACnet)APOGEE PXC Compact (P2 Ethernet)TALON TC Compact (BACnet)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2021-27388
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.72% / 81.63%
||
7 Day CHG~0.00%
Published-15 Jun, 2021 | 19:40
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

SINAMICS medium voltage routable products are affected by a vulnerability in the Sm@rtServer component for remote access that could allow an unauthenticated attacker to cause a denial-of-service condition, and/or execution of limited configuration modifications and/or execution of limited control commands on the SINAMICS Medium Voltage Products, Remote Access (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions).

Action-Not Available
Vendor-n/aSiemens AG
Product-sinamics_sl150sinamics_sm150isinamics_sm150_firmwaresinamics_sl150_firmwaresinamics_sm150i_firmwaresinamics_sm150SINAMICS Medium Voltage Products, Remote Access
CWE ID-CWE-20
Improper Input Validation
CVE-2023-43625
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.99% / 75.98%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:21
Updated-27 Feb, 2025 | 20:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Amesim (All versions < V2021.1). The affected application contains a SOAP endpoint that could allow an unauthenticated remote attacker to perform DLL injection and execute arbitrary code in the context of the affected application process.

Action-Not Available
Vendor-Siemens AG
Product-simcenter_amesimSimcenter Amesim
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2002-1484
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-7.03% / 91.11%
||
7 Day CHG~0.00%
Published-18 Mar, 2003 | 05:00
Updated-03 Apr, 2025 | 01:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

DB4Web server, when configured to use verbose debug messages, allows remote attackers to use DB4Web as a proxy and attempt TCP connections to other systems (port scan) via a request for a URL that specifies the target IP address and port, which produces a connection status in the resulting error message.

Action-Not Available
Vendor-n/aSiemens AG
Product-db4webn/a
CWE ID-CWE-918
Server-Side Request Forgery (SSRF)