The id parameter in detail.php of Online Book Store v1.0 is vulnerable to union-based blind SQL injection, which leads to the ability to retrieve all databases.
SQL injection in admin.php in Online Book Store 1.0 allows remote attackers to execute arbitrary SQL commands and bypass authentication.
A vulnerability was found in itsourcecode Online Bookstore 1.0. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file bookPerPub.php. The manipulation of the argument pubid leads to sql injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-268459.
A vulnerability was found in itsourcecode Online Book Store 1.0. It has been rated as critical. This issue affects some unknown processing of the file admin_delete.php. The manipulation of the argument bookisbn leads to sql injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-268721 was assigned to this vulnerability.
An issue was discovered on the D-Link DWR-932B router. There is a hardcoded WPS PIN of 28296607.
Mutiny 7.2.0-10788 suffers from Hardcoded root password.
Certain NETGEAR devices are affected by a hardcoded password. This affects D3600 before 1.0.0.76 and D6000 before 1.0.0.76.
BB-ESWGP506-2SFP-T versions 1.01.09 and prior is vulnerable due to the use of hard-coded credentials, which may allow an attacker to gain unauthorized access and permit the execution of arbitrary code on the BB-ESWGP506-2SFP-T (versions 1.01.01 and prior).
Ovarro TBox TWinSoft uses the custom hardcoded user “TWinSoft” with a hardcoded key.
FreeSWITCH 1.6.10 through 1.10.1 has a default password in event_socket.conf.xml.
In Veritas NetBackup OpsCenter, a hard-coded credential exists that could be used to exploit the underlying VxSS subsystem. This affects 8.x through 8.3.0.2, 9.x through 9.0.0.1, 9.1.x through 9.1.0.1, and 10.
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could an attacker to gain unauthorized administrative privileges when accessing to the charging station web server.
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges.
An information disclosure vulnerability exists in the WiFi Smart Mesh functionality of D-LINK DIR-3040 1.13B03. A specially-crafted network request can lead to command execution. An attacker can connect to the MQTT service to trigger this vulnerability.
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes.
auth_db_config.py in Pyftpd 0.8.4 contains hard-coded usernames and passwords for the (1) test, (2) user, and (3) roxon accounts, which allows remote attackers to read arbitrary files from the FTP server.
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Eurosoft Przychodnia installations. This issue affects Eurosoft Przychodnia software before version 20240417.001 (from that version vulnerability is fixed).
Linksys WAP54Gv3 firmware 3.04.03 and earlier uses a hard-coded username (Gemtek) and password (gemtekswd) for a debug interface for certain web pages, which allows remote attackers to execute arbitrary commands via the (1) data1, (2) data2, or (3) data3 parameters to (a) Debug_command_page.asp and (b) debug.cgi.
A hard-coded password vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to code execution. An attacker can send a sequence of requests to trigger this vulnerability.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The exported device configuration is encrypted with the hardcoded BpP+2R9*Q password in some cases.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The exported device configuration is encrypted with the hardcoded Pxift* password in some cases.
Gessler GmbH WEB-MASTER has a restoration account that uses weak hard coded credentials and if exploited could allow an attacker control over the web management of the device.
Dell EMC SCG Policy Manager, versions from 5.10 to 5.12, contain(s) a contain a Hard-coded Cryptographic Key vulnerability. An attacker with the knowledge of the hard-coded sensitive information, could potentially exploit this vulnerability to login to the system to gain admin privileges.
atbox.htm on D-Link DSL-2770L devices allows remote unauthenticated attackers to discover admin credentials.
Dell EMC SCG Policy Manager, versions from 5.10 to 5.12, contain(s) a contain a Hard-coded Cryptographic Key vulnerability. An attacker with the knowledge of the hard-coded sensitive information, could potentially exploit this vulnerability to login to the system to gain admin privileges.
spaces.htm on multiple D-Link devices (DSL, DIR, DWR) allows remote unauthenticated attackers to discover admin credentials.
Hardcoded manufacturer credentials and an OS command injection vulnerability in the /cgi-bin/mft/ directory on ABUS TVIP TVIP20050 LM.1.6.18, TVIP10051 LM.1.6.18, TVIP11050 MG.1.6.03.05, TVIP20550 LM.1.6.18, TVIP10050 LM.1.6.18, TVIP11550 MG.1.6.03, TVIP21050 MG.1.6.03, and TVIP51550 MG.1.6.03 cameras allow remote attackers to execute code as root.
An issue was discovered in the MensaMax (aka com.breustedt.mensamax) application 4.3 for Android. The use of a Hard-coded DES Cryptographic Key allows an attacker who decodes the application to decrypt transmitted data such as the login username and password.
Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system.
Retty App for Android versions prior to 4.8.13 and Retty App for iOS versions prior to 4.11.14 uses a hard-coded API key for an external service. By exploiting this vulnerability, API key for an external service may be obtained by analyzing data in the app.
A vulnerability in the Cisco Small Business Switches software could allow an unauthenticated, remote attacker to bypass the user authentication mechanism of an affected device. The vulnerability exists because under specific circumstances, the affected software enables a privileged user account without notifying administrators of the system. An attacker could exploit this vulnerability by using this account to log in to an affected device and execute commands with full admin rights. Cisco has not released software updates that address this vulnerability. This advisory will be updated with fixed software information once fixed software becomes available. There is a workaround to address this vulnerability.
The EPSON iPrint application 6.6.3 for Android contains hard-coded API and Secret keys for the Dropbox, Box, Evernote and OneDrive services.
Weintek EasyBuilder Pro contains a vulnerability that, even when the private key is immediately deleted after the crash report transmission is finished, the private key is exposed to the public, which could result in obtaining remote control of the crash report server.
A hardcoded secret key, in CA Unified Infrastructure Management 8.5.1, 8.5, and 8.4.7, allows attackers to access sensitive information.
A CWE-798 “Use of Hard-coded Credentials” vulnerability in the MariaDB database of the web application allows a remote unauthenticated attacker to access the database service and all included data with the same privileges of the web application. This issue affects: AiLux imx6 bundle below version imx6_1.0.7-2.
Dairy Farm Shop Management System v1.0 was discovered to contain hardcoded credentials in the source code which allows attackers access to the control panel if compromised.
Online Course Registration v1.0 was discovered to contain hardcoded credentials in the source code which allows attackers access to the control panel if compromised.
IBM Security Verify Bridge contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 196618.
libnx_apl.so on Nexans FTTO GigaSwitch before 6.02N and 7.x before 7.02 implements a Backdoor Account for SSH logins on port 50200 or 50201.
OMICARD EDM has a hard-coded machine key. An unauthenticated remote attacker can use the machine key to send serialized payload to the server to execute arbitrary code, manipulate system data and disrupt service.
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to 1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing remote code execution.
IBM Storage Fusion HCI 2.1.0 through 2.6.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 275671.
Echelon SmartServer 2.2 with i.LON Vision 2.2 stores cleartext credentials in a file, which could allow an attacker to obtain cleartext usernames and passwords of the SmartServer. If the attacker obtains the file, then the credentials could be used to control the web user interface and file transfer protocol (FTP) server.
A hardcoded cryptographic key in Automation360 22 allows an attacker to decrypt exported RPA packages.
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
A vulnerability was determined in yeqifu carRental up to 3fabb7eae93d209426638863980301d6f99866b3. Affected by this vulnerability is an unknown functionality of the file /carRental_war/druid/login.html of the component Druid. Executing manipulation can lead to hard-coded credentials. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized. This product operates on a rolling release basis, ensuring continuous delivery. Consequently, there are no version details for either affected or updated releases.
The Motorola ACE1000 RTU through 2022-05-02 ships with a hardcoded SSH private key and initialization scripts (such as /etc/init.d/sshd_service) only generate a new key if no private-key file exists. Thus, this hardcoded key is likely to be used by default.
Default and unremovable support credentials (user:nwk password:nwk2) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the RadioRA 2 Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
The Motorola ACE1000 RTU through 2022-05-02 uses ECB encryption unsafely. It can communicate with an XRT LAN-to-radio gateway by means of an embedded client. Credentials for accessing this gateway are stored after being encrypted with the Tiny Encryption Algorithm (TEA) in ECB mode using a hardcoded key. Similarly, the ACE1000 RTU can route MDLC traffic over Extended Command and Management Protocol (XCMP) and Network Layer (XNL) networks via the MDLC driver. Authentication to the XNL port is protected by TEA in ECB mode using a hardcoded key.
Rundeck is an open source automation service with a web console, command line tools and a WebAPI. Rundeck community and rundeck-enterprise docker images contained a pre-generated SSH keypair. If the id_rsa.pub public key of the keypair was copied to authorized_keys files on remote host, those hosts would allow access to anyone with the exposed private credentials. This misconfiguration only impacts Rundeck Docker instances of PagerDuty® Process Automation On Prem (formerly Rundeck) version 4.0 and earlier, not Debian, RPM or .WAR. Additionally, the id_rsa.pub file would have to be copied from the Docker image filesystem contents without overwriting it and used to configure SSH access on a host. A patch on Rundeck's `main` branch has removed the pre-generated SSH key pair, but it does not remove exposed keys that have been configured. To patch, users must run a script on hosts in their environment to search for exposed keys and rotate them. Two workarounds are available: Do not use any pre-existing public key file from the rundeck docker images to allow SSH access by adding it to authorized_keys files and, if you have copied the public key file included in the docker image, remove it from any authorized_keys files.