A Credential Management vulnerability exists in FoxView HMI SCADA (All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 (CCS 9.4) and FoxView 10.5.) which could cause unauthorized disclosure, modification, or disruption in service when the password is modified without permission.
An “uninitialized variable” code execution vulnerability exists in the Rockwell Automation Arena® that could allow a threat actor to craft a DOE file and force the software to access a variable before it being initialized. If exploited, a threat actor could leverage this vulnerability to execute arbitrary code. To exploit this vulnerability, a legitimate user must execute the malicious code crafted by the threat actor.
An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation.
procps-ng before version 3.3.15 is vulnerable to multiple integer overflows leading to a heap corruption in file2strvec function. This allows a privilege escalation for a local attacker who can create entries in procfs by starting processes, which could result in crashes or arbitrary code execution in proc utilities run by other users.
A CWE-276: Incorrect Default Permissions vulnerability exists that could cause unauthorized access to the base installation directory leading to local privilege escalation. Affected Product: Harmony/Magelis iPC Series (All Versions), Vijeo Designer (All Versions prior to V6.2 SP11 Multiple HotFix 4), Vijeo Designer Basic (All Versions prior to V1.2.1)
Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert
A vulnerability exists in Schneider Electric's Pro-Face GP Pro EX version 4.07.000 that allows an attacker to execute arbitrary code. Malicious code installation requires an access to the computer. By placing a specific DLL/OCX file, an attacker is able to force the process to load arbitrary DLL and execute arbitrary code in the context of the process.
Improper Privilege Management vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause shell access when unauthorized code is loaded into the system folder.
Use of Password Hash with Insufficient Computational Effort vulnerability exists in ClearSCADA (all versions), EcoStruxure Geo SCADA Expert 2019 (all versions), and EcoStruxure Geo SCADA Expert 2020 (V83.7742.1 and prior), which could cause the revealing of account credentials when server database files are available. Exposure of these files to an attacker can make the system vulnerable to password decryption attacks. Note that “.sde” configuration export files do not contain user account password hashes.
A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller.
Incorrect Default Permission vulnerability exists in SoMove (V2.8.1) and prior which could cause elevation of privilege and provide full access control to local system users to SoMove component and services when a SoMove installer script is launched.
A CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker access to the authorization credentials for a device and gain full access.
A security misconfiguration vulnerability exists in Schneider Electric's IGSS SCADA Software versions 12 and prior. Security configuration settings such as Address Space Layout Randomization (ASLR) and Data Execution prevention (DEP) were not properly configured resulting in weak security.
A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger.
A Use of Hardcoded Credentials vulnerability exists in AquaView versions 1.60, 7.x, and 8.x that could allow an authenticated local attacker to manipulate users and system settings.
In all versions of FactoryTalk View SE, after bypassing memory corruption mechanisms found in the operating system, a local, authenticated attacker may corrupt the associated memory space allowing for arbitrary code execution. Rockwell Automation recommends applying patch 1126290. Before installing this patch, the patch rollup dated 06 Apr 2020 or later MUST be applied. 1066644 – Patch Roll-up for CPR9 SRx.
A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert (ClearSCADA) -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the file system of that operating system to exploit this vulnerability. Affected versions in current support includes ClearSCADA 2017 R3, ClearSCADA 2017 R2, and ClearSCADA 2017.
Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence.
A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)
Improper Privilege Management vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a code execution issue when an attacker loads unauthorized code on the web server.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a local user to execute processes that otherwise require escalation privileges when sending local network commands to the IGSS Update Service.
A DLL hijacking vulnerability exists in Schneider Electric Software Update (SESU), all versions prior to V2.2.0, which could allow an attacker to execute arbitrary code on the targeted system when placing a specific DLL file.
A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.
A CWE-427: Uncontrolled Search Path Element vulnerability exists in GP-Pro EX,V4.09.250 and prior, that could cause local code execution with elevated privileges when installing the software.
Rockwell Automation DriveTools SP v5.13 and below and Drives AOP v4.12 and below both contain a vulnerability that a local attacker with limited privileges may be able to exploit resulting in privilege escalation and complete control of the system.
A DLL Hijacking vulnerability in the programming software in Schneider Electric's SoMachine HVAC v2.1.0 allows a remote attacker to execute arbitrary code on the targeted system. The vulnerability exists due to the improper loading of a DLL.
A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 12 and previous versions. The software will execute a malicious file if it is named the same as a legitimate file and placed in a location that is earlier in the search path.
A CWE-427 - Uncontrolled Search Path Element vulnerability exists that could allow an attacker with a local privileged account to place a specially crafted file on the target machine, which may give the attacker the ability to execute arbitrary code during the installation process initiated by a valid user. Affected Products: Easergy Builder Installer (1.7.23 and prior)
A CWE-427: Uncontrolled Search Path Element vulnerability exists in ProSoft Configurator (v1.002 and prior), for the PMEPXM0100 (H) module, which could cause the execution of untrusted code when using double click to open a project file which may trigger execution of a malicious DLL.
A DLL Hijack issue was discovered in Rockwell Automation Connected Components Workbench (CCW). The following versions are affected: Connected Components Workbench - Developer Edition, v9.01.00 and earlier: 9328-CCWDEVENE, 9328-CCWDEVZHE, 9328-CCWDEVFRE, 9328-CCWDEVITE, 9328-CCWDEVDEE, 9328-CCWDEVESE, and 9328-CCWDEVPTE; and Connected Components Workbench - Free Standard Edition (All Supported Languages), v9.01.00 and earlier. Certain DLLs included with versions of CCW software can be potentially hijacked to allow an attacker to gain rights to a victim's affected personal computer. Such access rights can be at the same or potentially higher level of privileges as the compromised user account, including and up to computer administrator privileges.
In Fazecast jSerialComm, Version 2.2.2 and prior, an uncontrolled search path element vulnerability could allow a malicious DLL file with the same name of any resident DLLs inside the software installation to execute arbitrary code.
A CWE-427:Uncontrolled Search Path Element vulnerability exists in MSX Configurator (Software Version prior to V1.0.8.1), which could cause privilege escalation when injecting a malicious DLL.
A CWE-427: Uncontrolled Search Path Element vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow a malicious DLL file, with the same name of any resident DLLs inside the software installation, to execute arbitrary code in all versions of ProClima prior to version 8.0.0.
Adobe ColdFusion Update 5 and earlier versions, ColdFusion 11 Update 13 and earlier versions have an exploitable Insecure Library Loading vulnerability. Successful exploitation could lead to local privilege escalation.
DLL injection vulnerability in the installation executables (Autorun.exe and Setup.exe) for Intel's wireless drivers and related software in Intel Dual Band Wireless-AC, Tri-Band Wireless-AC and Wireless-AC family of products allows a local attacker to cause escalation of privilege via remote code execution.
NVIDIA Windows GPU Display driver software for Windows (all versions) contains a vulnerability in which it incorrectly loads Windows system DLLs without validating the path or signature (also known as a binary planting or DLL preloading attack), leading to escalation of privileges through code execution.
Uncontrolled Search Path Element vulnerability in the openssl component as used in Bitdefender GravityZone Business Security allows an attacker to load a third party DLL to elevate privileges. This issue affects Bitdefender GravityZone Business Security versions prior to 6.6.23.329.
Uncontrolled search path in the Intel(R) GPA software before version 21.2 may allow an authenticated user to potentially enable escalation of privilege via local access.
A vulnerability in the DLL loading component of Cisco Advanced Malware Protection (AMP) for Endpoints on Windows could allow an authenticated, local attacker to disable system scanning services or take other actions to prevent detection of unauthorized intrusions. To exploit this vulnerability, the attacker would need to have administrative credentials on the Windows system. The vulnerability is due to the improper validation of resources loaded by a system process at run time. An attacker could exploit this vulnerability by crafting a malicious DLL file and placing it in a specific location on the targeted system. A successful exploit could allow the attacker to disable the targeted system's scanning services and ultimately prevent the system from being protected from further intrusion. There are no workarounds that address this vulnerability.
DLL Hijacking vulnerability in CorelDRAW X7, Corel Photo-Paint X7, Corel PaintShop Pro X7, Corel Painter 2015, and Corel PDF Fusion.
IBM SDK, Java Technology Edition Version 8 on the AIX platform uses absolute RPATHs which may facilitate code injection and privilege elevation by local users. IBM X-Force ID: 152081.
DLL injection vulnerability in software installer for Intel Data Center Migration Center Software v3.1 and before may allow an authenticated user to potentially execute code using default directory permissions via local access.
Uncontrolled search path in the Intel(R) SUR for Gameplay Software before version 2.0.1901 may allow a privillaged user to potentially enable escalation of privilege via local access.
Uncontrolled search path in Intel(R) SCS Add-on for Microsoft* SCCM before version 2.1.10 may allow an authenticated user to potentially enable escalation of privilege via local access.
Symantec Endpoint Protection (SEP) and Symantec Endpoint Protection Small Business Edition (SEP SBE), prior to 14.2 RU2 MP1 and prior to 14.2.5569.2100 respectively, may be susceptible to a DLL injection vulnerability, which is a type of issue whereby an individual attempts to execute their own code in place of legitimate code as a means to perform an exploit.
Uncontrolled search path element in some Intel(R) XTU software before version 7.12.0.15 may allow an authenticated user to potentially enable escalation of privilege via local access.
Uncontrolled search path in some Intel(R) NUC Pro Chassis Element AverMedia Capture Card drivers before version 3.0.64.143 may allow an authenticated user to potentially enable escalation of privilege via local access.
The "pingsender" executable used by the Firefox Health Report dynamically loads a system copy of libcurl, which an attacker could replace. This allows for privilege escalation as the replaced libcurl code will run with Firefox's privileges. Note: This attack requires an attacker have local system access and only affects OS X and Linux. Windows systems are not affected. This vulnerability affects Firefox < 57.
Uncontrolled Search Path Element in software for Intel(R) PROSet/Wireless Wi-Fi in Windows 10 and 11 may allow a privileged user to potentially enable escalation of privilege via local access.
Delta Electronics DIALink versions 1.2.4.0 and prior default permissions give extensive permissions to low-privileged user accounts, which may allow an attacker to modify the installation directory and upload malicious files.