Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2020-25238

Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-09 Feb, 2021 | 15:38
Updated At-04 Aug, 2024 | 15:33
Rejected At-
Credits

A vulnerability has been identified in PCS neo (Administration Console) (All versions < V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:09 Feb, 2021 | 15:38
Updated At:04 Aug, 2024 | 15:33
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in PCS neo (Administration Console) (All versions < V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system.

Affected Products
Vendor
Siemens AGSiemens
Product
PCS neo (Administration Console)
Versions
Affected
  • All versions < V3.1
Vendor
Siemens AGSiemens
Product
TIA Portal
Versions
Affected
  • V15, V15.1 and V16
Problem Types
TypeCWE IDDescription
CWECWE-284CWE-284: Improper Access Control
Type: CWE
CWE ID: CWE-284
Description: CWE-284: Improper Access Control
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf
x_refsource_MISC
https://www.kb.cert.org/vuls/id/466044
third-party-advisory
x_refsource_CERT-VN
https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05
x_refsource_MISC
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf
Resource:
x_refsource_MISC
Hyperlink: https://www.kb.cert.org/vuls/id/466044
Resource:
third-party-advisory
x_refsource_CERT-VN
Hyperlink: https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf
x_refsource_MISC
x_transferred
https://www.kb.cert.org/vuls/id/466044
third-party-advisory
x_refsource_CERT-VN
x_transferred
https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05
x_refsource_MISC
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf
Resource:
x_refsource_MISC
x_transferred
Hyperlink: https://www.kb.cert.org/vuls/id/466044
Resource:
third-party-advisory
x_refsource_CERT-VN
x_transferred
Hyperlink: https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:09 Feb, 2021 | 17:15
Updated At:21 Oct, 2022 | 18:21

A vulnerability has been identified in PCS neo (Administration Console) (All versions < V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.17.8HIGH
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary2.07.2HIGH
AV:L/AC:L/Au:N/C:C/I:C/A:C
Type: Primary
Version: 3.1
Base score: 7.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 7.2
Base severity: HIGH
Vector:
AV:L/AC:L/Au:N/C:C/I:C/A:C
CPE Matches

Siemens AG
siemens
>>simatic_process_control_system_neo>>Versions before 3.1(exclusive)
cpe:2.3:a:siemens:simatic_process_control_system_neo:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>totally_integrated_automation_portal>>15
cpe:2.3:a:siemens:totally_integrated_automation_portal:15:*:*:*:*:*:*:*
Siemens AG
siemens
>>totally_integrated_automation_portal>>15.1
cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:*:*:*:*:*:*:*
Siemens AG
siemens
>>totally_integrated_automation_portal>>16
cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-427Primarynvd@nist.gov
CWE-284Secondaryproductcert@siemens.com
CWE ID: CWE-427
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-284
Type: Secondary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdfproductcert@siemens.com
Vendor Advisory
https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05productcert@siemens.com
Third Party Advisory
US Government Resource
VDB Entry
https://www.kb.cert.org/vuls/id/466044productcert@siemens.com
Third Party Advisory
US Government Resource
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf
Source: productcert@siemens.com
Resource:
Vendor Advisory
Hyperlink: https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05
Source: productcert@siemens.com
Resource:
Third Party Advisory
US Government Resource
VDB Entry
Hyperlink: https://www.kb.cert.org/vuls/id/466044
Source: productcert@siemens.com
Resource:
Third Party Advisory
US Government Resource

Change History

0
Information is not available yet

Similar CVEs

630Records found

CVE-2025-23365
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.5||HIGH
EPSS-0.01% / 2.03%
||
7 Day CHG~0.00%
Published-08 Jul, 2025 | 10:34
Updated-21 Aug, 2025 | 15:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TIA Administrator (All versions < V3.0.6). The affected application allows low-privileged users to trigger installations by overwriting cache files and modifying the downloads path. This would allow an attacker to escalate privilege and exceute arbitrary code.

Action-Not Available
Vendor-Siemens AG
Product-tia_administratorTIA Administrator
CWE ID-CWE-284
Improper Access Control
CVE-2020-7585
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.09% / 25.92%
||
7 Day CHG~0.00%
Published-10 Jun, 2020 | 16:23
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information.

Action-Not Available
Vendor-Siemens AG
Product-simatic_step_7simatic_pcs_7sinamics_startersimatic_process_device_managerSIMATIC STEP 7 V5.XSIMATIC PCS 7 V8.2 and earlierSINAMICS STARTER (containing STEP 7 OEM version)SIMATIC PCS 7 V9.0SIMATIC PDM
CWE ID-CWE-427
Uncontrolled Search Path Element
CVE-2021-42029
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.04% / 10.03%
||
7 Day CHG~0.00%
Published-12 Apr, 2022 | 09:07
Updated-04 Aug, 2024 | 03:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 5), SIMATIC STEP 7 (TIA Portal) V17 (All versions < V17 Update 2). An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server.

Action-Not Available
Vendor-Siemens AG
Product-simatic_s7-1500_cpu_1507ssimatic_s7-1500_cpu_1516t-3simatic_s7-1500_cpu_1511csimatic_s7-1500_cpu_1512sp-1simatic_s7-1500_cpusimatic_s7-1500_cpu_1518-4_pn\/dp_mfpsimatic_s7-1500_cpu_1510sp-1simatic_s7-1200_cpu_1212csimatic_s7-1500_cpu_1515t-2simatic_s7-1500_cpu_1512spf-1simatic_s7-1500_cpu_1518-4_pnsimatic_s7-1500_cpu_1513-1simatic_s7-1500_cpu_1517-3_pnsimatic_s7-1500_cpu_1510spsimatic_s7-1200_cpu_1217csimatic_s7-1500_cpu_1517f-3_pn\/dpsimatic_s7-1500_cpu_1513r-1simatic_s7-1200_cpu_1215_fcsimatic_s7-1500_cpu_1511-1simatic_s7-1500_cpu_1518-4_dpsimatic_s7-1500_cpu_1513-1_pnsimatic_s7-1500_cpu_1511-1_pnsimatic_step_7simatic_s7-1500_cpu_1518hf-4simatic_s7-1200_cpu_1215csimatic_s7-1500_cpu_1515r-2simatic_s7-1500_cpu_1513f-1simatic_s7-1500_cpu_1512csimatic_s7-1500_cpu_1516f-3_pn\/dpsimatic_s7-1500_cpu_1511c-1simatic_s7-1500_cpu_1517-3_pn\/dpsimatic_s7-1500_cpu_1517-3simatic_s7-1500_cpu_1517f-3simatic_s7-1500_cpu_1508s_fsimatic_s7-1200_cpusimatic_s7-1500_cpu_1513f-1_pnsimatic_s7-1500_cpu_1517-3_dpsimatic_s7-1200_cpu_1214csimatic_s7-1500_cpu_1516tf-3simatic_s7-1500_cpu_1511t-1simatic_s7-1500_cpu_1517tf-3simatic_s7-1500_cpu_1511f-1simatic_s7-1500_cpu_1515-2_pnsimatic_s7-1200_cpu_1214_fcsimatic_s7-1500_cpu_1515tf-2simatic_s7-1500_cpu_1511tf-1simatic_s7-1500_cpu_1515-2simatic_s7-1500_cpu_1518-4simatic_s7-1500_cpu_1518-4_pn\/dpsimatic_s7-1500_cpu_1516-3_pnsimatic_s7-1500_cpu_1516-3_dpsimatic_s7-1500_cpu_1508ssimatic_s7-1500_cpu_1516-3_pn\/dpsimatic_s7-1500_cpu_1516-3simatic_s7-1200_cpu_1214fcsimatic_s7-1500_cpu_1518f-4_pn\/dpsimatic_s7-1500_cpu_1515f-2simatic_s7-1500_cpu_1512c-1simatic_s7-1500_cpu_1511f-1_pnsimatic_s7-1500_cpu_1515f-2_pnsimatic_s7-1500_cpu_1507s_fsimatic_s7-1200_cpu_1211csimatic_s7-1500_cpu_1516f-3simatic_s7-1500_cpu_1518simatic_s7-1200_cpu_1215fcsimatic_s7-1500_cpu_1518f-4simatic_s7-1500_cpu_1516pro_fsimatic_s7-1200_cpu_1212fcsimatic_s7-1500_cpu_1516pro-2simatic_s7-1500_cpu_1518tf-4simatic_s7-1500_cpu_1518t-4SIMATIC STEP 7 (TIA Portal) V17SIMATIC STEP 7 (TIA Portal) V16SIMATIC STEP 7 (TIA Portal) V15
CWE ID-CWE-284
Improper Access Control
CVE-2019-18309
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.09% / 27.27%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with local access to the MS3000 Server and a low privileged user account could gain root privileges by manipulating specific files in the local file system. This vulnerability is independent from CVE-2019-18308. Please note that an attacker needs to have local access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-284
Improper Access Control
CVE-2019-18308
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.09% / 27.27%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with local access to the MS3000 Server and a low privileged user account could gain root privileges by manipulating specific files in the local file system. This vulnerability is independent from CVE-2019-18309. Please note that an attacker needs to have local access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-284
Improper Access Control
CVE-2021-41544
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.03% / 7.50%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-11 Oct, 2024 | 22:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Siemens Software Center (All versions < V3.0). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.

Action-Not Available
Vendor-Siemens AG
Product-software_centerSiemens Software Center
CWE ID-CWE-427
Uncontrolled Search Path Element
CVE-2022-38466
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.04% / 10.16%
||
7 Day CHG~0.00%
Published-13 Sep, 2022 | 09:40
Updated-03 Aug, 2024 | 10:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in CoreShield One-Way Gateway (OWG) Software (All versions < V2.2). The default installation sets insecure file permissions that could allow a local attacker to escalate privileges to local administrator.

Action-Not Available
Vendor-Siemens AG
Product-coreshield_one-way_gatewayCoreShield One-Way Gateway (OWG) Software
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-276
Incorrect Default Permissions
CVE-2020-25244
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.4||HIGH
EPSS-0.04% / 10.63%
||
7 Day CHG~0.00%
Published-22 Apr, 2021 | 20:42
Updated-04 Aug, 2024 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in LOGO! Soft Comfort (All versions < V8.4). The software insecurely loads libraries which makes it vulnerable to DLL hijacking. Successful exploitation by a local attacker could lead to a takeover of the system where the software is installed.

Action-Not Available
Vendor-Siemens AG
Product-logo\!_soft_comfortLOGO! Soft Comfort
CWE ID-CWE-427
Uncontrolled Search Path Element
CVE-2010-2772
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.08% / 24.02%
||
7 Day CHG-0.01%
Published-22 Jul, 2010 | 10:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.

Action-Not Available
Vendor-n/aSiemens AG
Product-simatic_winccsimatic_pcs_7n/a
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2024-22042
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.07% / 20.31%
||
7 Day CHG~0.00%
Published-13 Feb, 2024 | 09:00
Updated-10 Apr, 2025 | 19:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Unicam FX (All versions). The windows installer agent used in affected product contains incorrect use of privileged APIs that trigger the Windows Console Host (conhost.exe) as a child process with SYSTEM privileges. This could be exploited by an attacker to perform a local privilege escalation attack.

Action-Not Available
Vendor-Siemens AG
Product-unicam_fxUnicam FX
CWE ID-CWE-648
Incorrect Use of Privileged APIs
CVE-2018-3657
Matching Score-8
Assigner-Intel Corporation
ShareView Details
Matching Score-8
Assigner-Intel Corporation
CVSS Score-6.7||MEDIUM
EPSS-0.26% / 49.54%
||
7 Day CHG~0.00%
Published-12 Sep, 2018 | 19:00
Updated-16 Sep, 2024 | 20:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple buffer overflows in Intel AMT in Intel CSME firmware versions before version 12.0.5 may allow a privileged user to potentially execute arbitrary code with Intel AMT execution privilege via local access.

Action-Not Available
Vendor-Intel CorporationSiemens AG
Product-manageability_engine_firmwaresimatic_ipc677d_firmwaresimatic_ipc477e_firmwaresimatic_ipc427e_firmwaresimatic_ipc647d_firmwaresimatic_ipc427esimatic_ipc647dsimatic_ipc547e_firmwaresimatic_ipc627dsimatic_pc547esimatic_ipc847dsimatic_ipc827dsimatic_ipc547gsimatic_field_pg_m5_firmwaresimatic_ipc847d_firmwaresimatic_pc547g_firmwaresimatic_ipc677dsimatic_ipc627d_firmwaresimatic_itp1000_firmwaresimatic_ipc827d_firmwareconverged_security_management_engine_firmwaresimatic_ipc477esimatic_field_pg_m5simatic_itp1000active_management_technology_firmwareIntel(R) Active Management Technology
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2023-50236
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.02% / 4.23%
||
7 Day CHG~0.00%
Published-13 Feb, 2024 | 09:00
Updated-07 May, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Polarion ALM (All versions < V2404.0). The affected product is vulnerable due to weak file and folder permissions in the installation path. An attacker with local access could exploit this vulnerability to escalate privileges to NT AUTHORITY\SYSTEM.

Action-Not Available
Vendor-Siemens AG
Product-polarion_almPolarion ALM
CWE ID-CWE-276
Incorrect Default Permissions
CVE-2020-27001
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.18% / 39.63%
||
7 Day CHG~0.00%
Published-09 Feb, 2021 | 15:38
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.1.0.2), Teamcenter Visualization (All versions < V13.1.0.2). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12041)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-40580
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.4||MEDIUM
EPSS-0.02% / 2.64%
||
7 Day CHG~0.00%
Published-13 May, 2025 | 09:39
Updated-08 Jul, 2025 | 11:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices are vulnerable to a stack-based buffer overflow. This could allow a non-privileged local attacker to execute arbitrary code on the device or to cause a denial of service condition.

Action-Not Available
Vendor-Siemens AG
Product-scalance_lpe9403scalance_lpe9403_firmwareSCALANCE LPE9403
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-33627
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.2||HIGH
EPSS-0.15% / 35.99%
||
7 Day CHG~0.00%
Published-03 Feb, 2022 | 01:30
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.09.11, 5.1 before 05.17.11, 5.2 before 05.27.11, 5.3 before 05.36.11, 5.4 before 05.44.11, and 5.5 before 05.52.11 affecting FwBlockServiceSmm. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.

Action-Not Available
Vendor-n/aInsyde Software Corp. (ISC)Siemens AG
Product-simatic_ipc127e_firmwaresimatic_ipc477e_firmwaresimatic_ipc427e_firmwaresimatic_ipc847esimatic_ipc377gsimatic_ipc427esimatic_field_pg_m6insydeh2osimatic_ipc227gsimatic_ipc677esimatic_field_pg_m5_firmwaresimatic_ipc677e_firmwaresimatic_ipc277g_firmwaresimatic_ipc227g_firmwaresimatic_ipc127esimatic_ipc647e_firmwaresimatic_ipc277gsimatic_itp1000_firmwaresimatic_ipc627e_firmwaresimatic_ipc477esimatic_field_pg_m6_firmwaresimatic_ipc627esimatic_ipc847e_firmwaresimatic_ipc647esimatic_field_pg_m5simatic_itp1000simatic_ipc327gsimatic_ipc377g_firmwaresimatic_ipc327g_firmwaren/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2025-40582
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.5||HIGH
EPSS-0.03% / 6.73%
||
7 Day CHG~0.00%
Published-13 May, 2025 | 09:39
Updated-30 May, 2025 | 17:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions with SINEMA Remote Connect Edge Client installed). Affected devices do not properly sanitize configuration parameters. This could allow a non-privileged local attacker to execute root commands on the device.

Action-Not Available
Vendor-Siemens AG
Product-scalance_lpe9403_firmwarescalance_lpe9403SCALANCE LPE9403
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-40751
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-4.8||MEDIUM
EPSS-0.01% / 1.32%
||
7 Day CHG~0.00%
Published-12 Aug, 2025 | 11:17
Updated-20 Aug, 2025 | 20:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V3.3). Affected SIMATIC RTLS Locating Manager Report Clients do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role.

Action-Not Available
Vendor-Siemens AG
Product-simatic_rtls_locating_managerSIMATIC RTLS Locating Manager
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2025-40768
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7||HIGH
EPSS-0.01% / 1.59%
||
7 Day CHG~0.00%
Published-12 Aug, 2025 | 11:17
Updated-15 Aug, 2025 | 18:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V3.0). The affected application exposes an internal service port to be accessible from outside the system. This could allow an unauthorized attacker to access the application.

Action-Not Available
Vendor-Siemens AG
Product-sinec_traffic_analyzerSINEC Traffic Analyzer
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2025-40579
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.4||MEDIUM
EPSS-0.02% / 2.64%
||
7 Day CHG~0.00%
Published-13 May, 2025 | 09:39
Updated-08 Jul, 2025 | 11:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices are vulnerable to a stack-based buffer overflow. This could allow a non-privileged local attacker to execute arbitrary code on the device or to cause a denial of service condition.

Action-Not Available
Vendor-Siemens AG
Product-scalance_lpe9403scalance_lpe9403_firmwareSCALANCE LPE9403
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-33626
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.08% / 24.57%
||
7 Day CHG~0.00%
Published-01 Oct, 2021 | 02:21
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution.

Action-Not Available
Vendor-n/aInsyde Software Corp. (ISC)Siemens AG
Product-simatic_ipc127e_firmwaresimatic_ipc377ginsydeh2osimatic_ipc677esimatic_ipc227g_firmwaresimatic_ipc647e_firmwaresimatic_ipc277gsimatic_ipc627e_firmwaresimatic_ipc477esimatic_field_pg_m6_firmwaresimatic_ipc627esimatic_ipc847e_firmwaresimatic_field_pg_m5simatic_itp1000simatic_ipc377g_firmwaresimatic_ipc327g_firmwaresimatic_ipc477e_firmwaresimatic_ipc427e_firmwaresimatic_ipc847esimatic_ipc427esimatic_field_pg_m6ruggedcom_apr1808simatic_ipc227gsimatic_ipc477e_prosimatic_field_pg_m5_firmwaresimatic_ipc677e_firmwaresimatic_ipc477e_pro_firmwaresimatic_ipc277g_firmwaresimatic_ipc127esimatic_itp1000_firmwareruggedcom_apr1808_firmwaresimatic_ipc647esimatic_ipc327gn/a
CWE ID-CWE-829
Inclusion of Functionality from Untrusted Control Sphere
CVE-2025-40767
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.01% / 1.78%
||
7 Day CHG~0.00%
Published-12 Aug, 2025 | 11:17
Updated-15 Aug, 2025 | 18:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V3.0). The affected application runs docker containers without adequate security controls to enforce isolation. This could allow an attacker to gain elevated access, potentially accessing sensitive host system resources.

Action-Not Available
Vendor-Siemens AG
Product-sinec_traffic_analyzerSINEC Traffic Analyzer
CWE ID-CWE-250
Execution with Unnecessary Privileges
CVE-2021-31894
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.03% / 6.35%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:02
Updated-03 Aug, 2024 | 23:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions < V9.1 SP2), SIMATIC PDM (All versions < V9.2 SP2), SIMATIC STEP 7 V5.X (All versions < V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 SP2 HF1). A directory containing metafiles relevant to devices' configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software.

Action-Not Available
Vendor-Siemens AG
Product-simatic_step_7simatic_pdmsimatic_pcs_7sinamics_startersimatic_pcs_7_firmwaresimatic_step_7_firmwaresinamics_starter_firmwaresimatic_pdm_firmwareSIMATIC STEP 7 V5.XSIMATIC PCS 7 V9.XSIMATIC PCS 7 V8.2 and earlierSINAMICS STARTER (containing STEP 7 OEM version)SIMATIC PDM
CWE ID-CWE-732
Incorrect Permission Assignment for Critical Resource
CVE-2021-31893
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.13% / 33.60%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:02
Updated-03 Aug, 2024 | 23:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). The affected software contains a buffer overflow vulnerability while handling certain files that could allow a local attacker to trigger a denial-of-service condition or potentially lead to remote code execution.

Action-Not Available
Vendor-Siemens AG
Product-simatic_pcs_firmwaresimatic_step_7simatic_pdmsinamics_startersimatic_step_7_firmwaresimatic_pcssinamics_starter_firmwaresimatic_pdm_firmwareSIMATIC STEP 7 V5.XSIMATIC PCS 7 V8.2 and earlierSINAMICS STARTER (containing STEP 7 OEM version)SIMATIC PCS 7 V9.0SIMATIC PDM
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2018-11465
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 18.84%
||
7 Day CHG~0.00%
Published-12 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 08:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker could use ioctl calls to do out of bounds reads, arbitrary writes, or execute code in kernel mode. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sinumerik_808d_v4.8sinumerik_840d_sl_v4.7sinumerik_828d_v4.7_firmwaresinumerik_808d_v4.7_firmwaresinumerik_840d_sl_v4.7_firmwaresinumerik_840d_sl_v4.8_firmwaresinumerik_828d_v4.7sinumerik_840d_sl_v4.8sinumerik_808d_v4.8_firmwaresinumerik_808d_v4.7SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8
CWE ID-CWE-248
Uncaught Exception
CWE ID-CWE-125
Out-of-bounds Read
CVE-2018-11459
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.04% / 12.21%
||
7 Day CHG~0.00%
Published-12 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 08:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker could modify a user-writeable configuration file so that after reboot or manual initiation the system reloads the modified configuration file and attacker-controlled code is executed with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sinumerik_808d_v4.8sinumerik_840d_sl_v4.7sinumerik_828d_v4.7_firmwaresinumerik_808d_v4.7_firmwaresinumerik_840d_sl_v4.7_firmwaresinumerik_840d_sl_v4.8_firmwaresinumerik_828d_v4.7sinumerik_840d_sl_v4.8sinumerik_808d_v4.8_firmwaresinumerik_808d_v4.7SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8
CWE ID-CWE-693
Protection Mechanism Failure
CVE-2023-44120
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.08% / 25.06%
||
7 Day CHG~0.00%
Published-09 Jan, 2024 | 09:59
Updated-14 Nov, 2024 | 15:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Spectrum Power 7 (All versions < V23Q4). The affected product's sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access.

Action-Not Available
Vendor-Siemens AG
Product-spectrum_power_7Spectrum Power 7
CWE ID-CWE-732
Incorrect Permission Assignment for Critical Resource
CVE-2023-40727
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.03% / 8.23%
||
7 Day CHG~0.00%
Published-12 Sep, 2023 | 09:32
Updated-27 Feb, 2025 | 20:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in QMS Automotive (All versions < V12.39). The QMS.Mobile module of the affected application uses weak outdated application signing mechanism. This could allow an attacker to tamper the application code.

Action-Not Available
Vendor-Siemens AG
Product-qms_automotiveQMS Automotive
CWE ID-CWE-347
Improper Verification of Cryptographic Signature
CVE-2023-40728
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.06% / 19.60%
||
7 Day CHG~0.00%
Published-12 Sep, 2023 | 09:32
Updated-27 Feb, 2025 | 20:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in QMS Automotive (All versions < V12.39). The QMS.Mobile module of the affected application stores sensitive application data in an external insecure storage. This could allow an attacker to alter content, leading to arbitrary code execution or denial-of-service condition.

Action-Not Available
Vendor-Siemens AG
Product-qms_automotiveQMS Automotive
CWE ID-CWE-922
Insecure Storage of Sensitive Information
CVE-2023-38641
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.05% / 16.77%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-27 Feb, 2025 | 21:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM TOOLBOX II (All versions < V07.10). The affected application's database service is executed as `NT AUTHORITY\SYSTEM`. This could allow a local attacker to execute operating system commands with elevated privileges.

Action-Not Available
Vendor-Siemens AG
Product-sicam_toolbox_iiSICAM TOOLBOX II
CWE ID-CWE-250
Execution with Unnecessary Privileges
CVE-2018-11460
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.04% / 12.21%
||
7 Day CHG~0.00%
Published-12 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 08:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with elevated user privileges (manufact) could modify a CRAMFS archive so that after reboot the system loads the modified CRAMFS file and attacker-controlled code is executed with root privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires elevated user privileges (manufact) but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sinumerik_808d_v4.8sinumerik_840d_sl_v4.7sinumerik_828d_v4.7_firmwaresinumerik_808d_v4.7_firmwaresinumerik_840d_sl_v4.7_firmwaresinumerik_840d_sl_v4.8_firmwaresinumerik_828d_v4.7sinumerik_840d_sl_v4.8sinumerik_808d_v4.8_firmwaresinumerik_808d_v4.7SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8
CWE ID-CWE-693
Protection Mechanism Failure
CVE-2023-38557
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.2||HIGH
EPSS-0.02% / 2.37%
||
7 Day CHG~0.00%
Published-14 Sep, 2023 | 10:39
Updated-27 Feb, 2025 | 20:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Spectrum Power 7 (All versions < V23Q3). The affected product assigns improper access rights to the update script. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.

Action-Not Available
Vendor-Siemens AG
Product-spectrum_power_7Spectrum Power 7
CWE ID-CWE-732
Incorrect Permission Assignment for Critical Resource
CVE-2023-36380
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.06% / 19.67%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:21
Updated-27 Feb, 2025 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)), CP-8050 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)). The affected devices contain a hard-coded ID in the SSH `authorized_keys` configuration file. An attacker with knowledge of the corresponding private key could login to the device via SSH. Only devices with activated debug support are affected.

Action-Not Available
Vendor-Siemens AG
Product-cp-8050_firmwarecp-8050cp-8031_firmwarecp-8031CP-8031 MASTER MODULECP-8050 MASTER MODULE
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2022-43517
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.04% / 12.10%
||
7 Day CHG~0.00%
Published-13 Dec, 2022 | 00:00
Updated-21 Apr, 2025 | 13:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter STAR-CCM+ (All versions < V2306). The affected application improperly assigns file permissions to installation folders. This could allow a local attacker with an unprivileged account to override or modify the service executables and subsequently gain elevated privileges.

Action-Not Available
Vendor-Siemens AG
Product-star-ccm\+Simcenter STAR-CCM+
CWE ID-CWE-732
Incorrect Permission Assignment for Critical Resource
CVE-2020-10051
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.04% / 10.63%
||
7 Day CHG~0.00%
Published-09 Sep, 2020 | 18:09
Updated-04 Aug, 2024 | 10:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). Multiple services of the affected application are executed with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to inject arbitrary commands that are execeuted instead of the legitimate service.

Action-Not Available
Vendor-Siemens AG
Product-simatic_rtls_locating_managerSIMATIC RTLS Locating Manager
CWE ID-CWE-428
Unquoted Search Path or Element
CVE-2013-4943
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-0.04% / 12.12%
||
7 Day CHG~0.00%
Published-09 Aug, 2013 | 19:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The client application in Siemens COMOS before 9.1 Update 458, 9.2 before 9.2.0.6.37, and 10.0 before 10.0.3.0.19 allows local users to gain privileges and bypass intended database-operation restrictions by leveraging COMOS project access.

Action-Not Available
Vendor-n/aSiemens AG
Product-comosn/a
CVE-2019-19278
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.8||MEDIUM
EPSS-0.08% / 24.70%
||
7 Day CHG~0.00%
Published-16 Jan, 2020 | 15:35
Updated-05 Aug, 2024 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 Drives MLFB 6SR32..-.....-.... MLFB 6SR4...-.....-.... MLFB 6SR5...-.....-.... With option A30 (HMIs 12 inches or larger) (All versions), SINAMICS PERFECT HARMONY GH180 Drives MLFB 6SR325.-.....-.... (High Availability) (All versions). The affected device contains a vulnerability that could allow an unauthenticated attacker to restore the affected device to a point where predefined application and operating system protection mechanisms are not in place. Successful exploitation requires physical access to the system, but no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentialiy, integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sinamics_perfect_harmony_gh180_firmwaresinamics_perfect_harmony_gh180SINAMICS PERFECT HARMONY GH180 Drives MLFB 6SR325.-.....-.... (High Availability)SINAMICS PERFECT HARMONY GH180 Drives MLFB 6SR32..-.....-.... MLFB 6SR4...-.....-.... MLFB 6SR5...-.....-.... With option A30 (HMIs 12 inches or larger)
CWE ID-CWE-693
Protection Mechanism Failure
CWE ID-CWE-362
Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')
CVE-2022-38465
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.3||CRITICAL
EPSS-0.11% / 30.12%
||
7 Day CHG~0.00%
Published-11 Oct, 2022 | 00:00
Updated-21 Apr, 2025 | 13:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINUMERIK MC (All versions < V6.21), SINUMERIK ONE (All versions < V6.21). Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication. This could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG/PC and HMI communication.

Action-Not Available
Vendor-Siemens AG
Product-simatic_s7-1200_cpu_12_1214fcsimatic_s7-1500_cpu_1516t-3simatic_s7-1500_cpu_1510sp_firmwaresimatic_s7-1500_cpu_1511t-1_firmwaresimatic_s7-1500_cpu_1512sp-1simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmwaresimatic_s7-1200_cpu_12_1214c_firmwaresimatic_s7-1200_cpu_12_1211csimatic_s7-1200_cpu_12_1215fc_firmwaresimatic_s7-1500_cpu_1510sp-1simatic_s7-1500_cpu_15pro-2simatic_s7-1500_cpu_1515t-2simatic_s7-1500_cpu_1512spf-1simatic_s7-1200_cpu_12_1212fc_firmwaresimatic_et_200_open_controller_cpu_1515sp_pcsimatic_s7-1200_cpu_12_1212c_firmwaresimatic_drive_controller_cpu_1507d_tf_firmwaresimatic_s7-1500_cpu_1513-1simatic_s7-1500_cpu_15pro-2_firmwaresimatic_s7-1500_cpu_151511c-1_firmwaresimatic_s7-1200_cpu_12_1217csimatic_s7-1500_cpu_1510spsimatic_s7-1200_cpu_12_1217c_firmwaresimatic_s7-1500_cpu_1518f-4_firmwaresimatic_s7-1500_cpu_151511f-1simatic_s7-1500_cpu_1513r-1simatic_s7-1500_cpu_1511-1simatic_s7-1200_cpu_12_1215csimatic_s7-1500_cpu_1511-1_firmwaresimatic_s7-1500_cpu_1517f-3_firmwaresimatic_s7-1500_cpu_1518tf-4simatic_s7-1500_cpu_1515f-2_firmwaresimatic_s7-1500_cpu_1518hf-4simatic_s7-1500_cpu_1515r-2simatic_s7-1500_cpu_1516tf-3_firmwaresimatic_s7-1200_cpu_12_1215fcsimatic_s7-1500_cpu_1516-3_firmwaresimatic_s7-1500_cpu_1513f-1simatic_s7-1500_cpu_1517-3simatic_s7-1500_cpu_15prof-2_firmwaresimatic_s7-1500_cpu_1518t-4_firmwaresimatic_s7-1500_cpu_1517f-3simatic_s7-1500_cpu_1512spf-1_firmwaresimatic_s7-1500_cpu_1516f-3_firmwaresimatic_s7-1200_cpu_12_1214csimatic_s7-1500_cpu_1517-3_firmwaresimatic_s7-1200_cpu_12_1214fc_firmwaresimatic_s7-1500_software_controllersimatic_s7-1500_cpu_15prof-2simatic_s7-1500_cpu_1516tf-3simatic_et_200_open_controller_cpu_1515sp_pc2simatic_s7-1500_cpu_151511f-1_firmwaresimatic_s7-1500_cpu_1516t-3_firmwaresimatic_s7-1500_cpu_1518hf-4_firmwaresimatic_s7-1200_cpu_12_1212csimatic_s7-1500_cpu_1511t-1simatic_drive_controller_cpu_1504d_tf_firmwaresimatic_s7-1500_cpu_1515-2_firmwaresimatic_s7-1500_cpu_1511tf-1simatic_s7-1500_cpu_1515-2simatic_s7-1500_cpu_1518-4simatic_s7-1500_cpu_1511tf-1_firmwaresimatic_s7-1500_cpu_1516pro_f_firmwaresimatic_s7-plcsim_advanced_firmwaresimatic_s7-1500_cpu_1510sp-1_firmwaresimatic_s7-1500_cpu_1516-3simatic_s7-1500_cpu_1515t-2_firmwaresimatic_drive_controller_cpu_1504d_tfsimatic_drive_controller_cpu_1507d_tfsimatic_s7-1200_cpu_12_1215c_firmwaresimatic_s7-1200_cpu_12_1212fcsimatic_s7-1500_cpu_151511c-1simatic_s7-1500_cpu_1518tf-4_firmwaresimatic_s7-1500_cpu_1512sp-1_firmwaresimatic_s7-1500_cpu_1512c-1simatic_s7-1500_cpu_1515f-2simatic_et_200_sp_open_controller_cpu_1515sp_pc2_firmwaresimatic_s7-1500_cpu_1516f-3simatic_s7-1500_cpu_1518f-4simatic_s7-1500_cpu_1516pro_fsimatic_s7-1200_cpu_12_1211c_firmwaresimatic_s7-1500_cpu_1513r-1_firmwaresimatic_s7-1500_cpu_1512c-1_firmwaresimatic_s7-1500_cpu_1513f-1_firmwaresimatic_s7-1500_cpu_1515r-2_firmwaresimatic_s7-plcsim_advancedsimatic_s7-1500_cpu_1513-1_firmwaresimatic_s7-1500_cpu_1518-4_firmwaresimatic_s7-1500_cpu_1518t-4SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)SIMATIC S7-1500 Software ControllerSIMATIC S7-PLCSIM AdvancedSINUMERIK ONESIMATIC Drive Controller familySIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)SIMATIC S7-1200 CPU family (incl. SIPLUS variants)SINUMERIK MCSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2022-37893
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.8||HIGH
EPSS-0.22% / 44.17%
||
7 Day CHG~0.00%
Published-07 Oct, 2022 | 00:00
Updated-03 Aug, 2024 | 10:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An authenticated command injection vulnerability exists in the Aruba InstantOS and ArubaOS 10 command line interface. Successful exploitation of this vulnerability results in the ability to execute arbitrary commands as a privileged user on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InstantOS that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-arubaosscalance_w1750d_firmwareinstantscalance_w1750dAruba Access Points: 100 Series; 103 Series; 110 Series; 120 Series; 130 Series; 200 Series; 207 Series; 210 Series; 220 Series; 260 Series; 300 Series; 303 Series; 310 Series; 318 Series Hardened Access Points; 320 Series; 330 Series; 340 Series; 370 Series; 500 Series; 510 Series; 530 Series; 550 Series; 630 Series; 650 Series;
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-8744
Matching Score-8
Assigner-Intel Corporation
ShareView Details
Matching Score-8
Assigner-Intel Corporation
CVSS Score-7.8||HIGH
EPSS-0.16% / 37.04%
||
7 Day CHG-0.01%
Published-12 Nov, 2020 | 18:06
Updated-04 Aug, 2024 | 10:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper initialization in subsystem for Intel(R) CSME versions before12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25, Intel(R) TXE versions before 4.0.30 Intel(R) SPS versions before E3_05.01.04.200 may allow a privileged user to potentially enable escalation of privilege via local access.

Action-Not Available
Vendor-n/aIntel CorporationSiemens AG
Product-server_platform_servicessimatic_s7-1518f-4_pn\/dp_mfp_firmwaretrusted_execution_enginesimatic_s7-1518-4_pn\/dp_mfpconverged_security_and_management_enginesimatic_s7-1518f-4_pn\/dp_mfpsimatic_s7-1500_firmwaresimatic_s7-1518-4_pn\/dp_mfp_firmwaresimatic_s7-1500Intel(R) CSME versions, Intel(R) TXE, Intel(R) SPS
CWE ID-CWE-665
Improper Initialization
CVE-2020-8177
Matching Score-8
Assigner-HackerOne
ShareView Details
Matching Score-8
Assigner-HackerOne
CVSS Score-7.8||HIGH
EPSS-0.03% / 6.02%
||
7 Day CHG~0.00%
Published-14 Dec, 2020 | 19:42
Updated-04 Aug, 2024 | 09:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

curl 7.20.0 through 7.70.0 is vulnerable to improper restriction of names for files and other resources that can lead too overwriting a local file when the -J flag is used.

Action-Not Available
Vendor-n/aCURLDebian GNU/LinuxSplunk LLC (Cisco Systems, Inc.)Siemens AGFujitsu Limited
Product-m12-1m10-4s_firmwareuniversal_forwarderm10-4curlm12-1_firmwarem10-4sm10-4_firmwaresinec_infrastructure_network_servicesm12-2sdebian_linuxm10-1_firmwarem10-1m12-2s_firmwarem12-2_firmwarem12-2https://github.com/curl/curl
CWE ID-CWE-99
Improper Control of Resource Identifiers ('Resource Injection')
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2025-40574
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.5||HIGH
EPSS-0.01% / 1.81%
||
7 Day CHG~0.00%
Published-13 May, 2025 | 09:38
Updated-08 Jul, 2025 | 11:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly assign permissions to critical ressources. This could allow a non-privileged local attacker to interact with the backupmanager service.

Action-Not Available
Vendor-Siemens AG
Product-scalance_lpe9403scalance_lpe9403_firmwareSCALANCE LPE9403
CWE ID-CWE-732
Incorrect Permission Assignment for Critical Resource
CVE-2022-31808
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.07% / 22.48%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 10:36
Updated-20 Mar, 2025 | 20:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V2.85.44), SiPass integrated ACC-AP (All versions < V2.85.43). Affected devices improperly sanitize user input on the telnet command line interface. This could allow an authenticated user to escalate privileges by injecting arbitrary commands that are executed with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-sipass_integrated_acc-apsipass_integrated_acc-ap_firmwaresipass_integrated_ac5102_\(acc-g2\)_firmwaresipass_integrated_ac5102_\(acc-g2\)SiPass integrated AC5102 (ACC-G2)SiPass integrated ACC-AP
CWE ID-CWE-20
Improper Input Validation
CVE-2017-5711
Matching Score-8
Assigner-Intel Corporation
ShareView Details
Matching Score-8
Assigner-Intel Corporation
CVSS Score-7.8||HIGH
EPSS-0.15% / 35.97%
||
7 Day CHG~0.00%
Published-21 Nov, 2017 | 14:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple buffer overflows in Active Management Technology (AMT) in Intel Manageability Engine Firmware 8.x/9.x/10.x/11.0/11.5/11.6/11.7/11.10/11.20 allow attacker with local access to the system to execute arbitrary code with AMT execution privilege.

Action-Not Available
Vendor-ASUS (ASUSTeK Computer Inc.)Siemens AGIntel Corporation
Product-rog_strix_z270g_gaming_firmwareh110-plus_firmwareh170m-plus\/brsimatic_ipc627dprime_h110m-ptuf_z270_mark_2rog_strix_z270h_gaming\/k1prime_j3355i-cb150i_pro_gaming\/aurasimatic_ipc827ch110m-a\/dp_firmwaresimatic_ipc477d_firmwareq170t_firmwareb250m-f_plush110m-ksh110m-a_d3ex-b150m-v5rog_strix_b250i_gaming_firmwareh170_pro_gamingsimotion_p320-4strooper_b150_d3_firmwareh110s2b150m-dtuf_z370-plus_gaming_firmwareh110m-ts_firmwaresimatic_ipc647d_firmwareb150-asimatic_ipc477db150m-plus_d3_firmwarerog_maximus_viii_hero_firmwarerog_strix_z270f_gamingrog_maximus_viii_ranger_firmwareb150m-v_plus_firmwareprime_q270m-ch110-plush110s2_firmwareh110m-e_firmwareprime_h110m2\/fpt_firmwaresabertooth_z170_mark_1h110m-c\/hdmi_firmwaresinumerik_pcu50.5-p_firmwaretuf_z370-pro_gaming_firmwarerog_maximus_viii_hero_alpha_firmwarerog_maximus_ix_hero_firmwarez170-krog_strix_b250g_gaming_firmwarerog_strix_z370-f_gamingb150m-ah110m-aex-b250m-v5z170-prosimatic_ipc477eb150m-k_d3prime_h110m2_firmwarerog_maximus_viii_formulaprime_b250m-dsimatic_field_pg_m3_firmwarerog_maximus_ix_extremesimatic_ipc677cb150m-k_firmwareq170s1_firmwareex-b150m-v3_firmwareprime_b250m-jb150m-a_d3_firmwarez170m-e_d3z170-k_firmwarepio-b150m_firmwarerog_strix_h270i_gaming_firmwareh170m-plush110m-ks_r1_firmwareex-b250-v7b150m-plusz170-ar_firmwareh110m-plusb150m-v_plush110m-kex-b150-v7_firmwareh110m-a_d3_firmwarerog_strix_b250h_gaming_firmwareh110m-c\/br_firmwarez170m-plus\/brprime_h270-plus_firmwareprime_h110m2\/fptprime_z270m-plus\/br_firmwareh110t-a_firmwareh110i-plus_firmwaresimatic_ipc627d_firmwaresimatic_field_pg_m3prime_z270-kh170i-pro_firmwaresimatic_field_pg_m4simatic_ipc627ch170i-prob150m-plus_d3z170-premium_firmwaresabertooth_z170_mark_1_firmwareb150m-f_plush170m-e_d3z170-eb150-pro_firmwarepio-b150mrog_maximus_ix_codeprime_b250-plus_firmwareh110m-c_firmwarerog_maximus_x_hero_firmwaresimatic_itp1000simatic_ipc427d_firmwareh110m-e\/m.2_firmwareprime_h110m2rog_maximus_x_formularog_maximus_x_formula_firmwareh110m-d\/exper\/sib150_pro_gaming\/aura_firmwaremanageability_engine_firmwarerog_maximus_ix_herorog_strix_z270i_gamingh170-plus_d3_firmwareex-b150m-v_firmwareq170m-cm-brog_strix_z370-g_gamingprime_z270-arb150-pro_d3rog_strix_z270h_gamingh110m-cs\/br_firmwarerog_strix_z370-i_gamingrog_strix_z370-h_gaming_firmwareh110m-d_firmwaresabertooth_z170_sb150_pro_gamingh110m-a\/m.2q270m-cm-asimatic_ipc847c_firmwareh110m-rh170-pro\/usb_3.1_firmwareq170m2_firmwareb150m-kprime_z270m-plus_firmwareh110m-a_firmwareex-h110m-v3_firmwareh110m-k_x_firmwarez170m-e_d3_firmwareh170_pro_gaming_firmwareb150m-k_d3_firmwarerog_strix_z270f_gaming_firmwarerog_strix_b250f_gamingh110m-cs\/brq170s1ex-b250-v7_firmwaresabertooth_z170_s_firmwarerog_strix_b250h_gamingh110m-d\/exper\/si_firmwareex-b150m-v5_firmwareprime_b250m-d_firmwareh110m-p\/dvib150i_pro_gaming\/aura_firmwaresimatic_ipc647db150m-f_plus_firmwareh110m-ks_r1h110m-c\/ps_firmwareb150-proprime_h270-proex-h110m-v_firmwareex-b250m-v3rog_strix_z270g_gamingrog_maximus_ix_formula_firmwarerog_maximus_viii_gene_firmwareprime_z270-p_firmwareex-h110m-v3h110m-c2\/tf_firmwarez170-p_firmwareq270-sactive_management_technology_firmwaresimatic_ipc427e_firmwarez170m-plustrooper_h110_d3z170-deluxe_firmwaresimatic_ipc547d_firmwaresimatic_ipc847cprime_q270m-c_firmwaresimatic_ipc547dh170m-plus_firmwareb250_mining_expert_firmwarerog_strix_h270i_gamingrog_strix_z270h_gaming\/k1_firmwareprime_z370-pz170-e_firmwarerog_maximus_viii_extreme_firmwareb250_mining_expertb150m-a_d3simatic_ipc677dh110m-c2prime_b250m-a_firmwaresimatic_ipc627c_firmwareprime_b250m-plus\/br_firmwarez170-ah110m-k_firmwaretuf_z270_mark_1_firmwareb150_pro_gaming_d3q170m-c_firmwarez170_pro_gaming\/auraex-b250m-vh110m-a\/m.2_firmwareb150m-d_firmwarerog_strix_b250f_gaming_firmwareprime_z370-a_firmwaresinumerik_pcu50.5-crog_maximus_x_code_firmwarerog_maximus_viii_impactsimatic_ipc827d_firmwareprime_b250m-plus_firmwarez170-deluxeb150m-cprime_b250m-plush110m-cs_xb150-pro_d3_firmwareprime_b250-proz170-a_firmwareb150_pro_gaming_d3_firmwareb150-plusprime_z270-a_firmwareprime_z270-k_firmwareh110m-c\/hdmisimatic_itp1000_firmwareprime_b250-a_firmwareprime_b250-arog_maximus_viii_geneh110t-aex-b250m-v5_firmwaresimatic_ipc647c_firmwareb150-a_firmwaresimatic_ipc427drog_maximus_viii_impact_firmwareq170th110m-r_firmwareh110m-crog_maximus_ix_apex_firmwareprime_z270-ar_firmwarez170_pro_gaming\/aura_firmwareh110m-fprime_b250m-k_firmwareprime_b250m-j_firmwarerog_strix_z370-e_gamingprime_b250m-c_firmwarerog_strix_z270i_gaming_firmwareprime_b250m-ah110m-p\/dvi_firmwareb150m-a_firmwareh170-plus_d3h110m-c\/brrog_strix_b250g_gamingb250-srog_maximus_ix_extreme_firmwareprime_z270m-plusb150_pro_gaming_firmwareex-b150-v7prime_j3355i-c_firmwareb150m-c_d3_firmwaresimatic_ipc427eprime_b250-pro_firmwareh110tq170m2\/cdm\/sib150m-a\/m.2z170_pro_gaming_firmwarerog_strix_z270e_gaming_firmwareb150m-c_firmwarerog_strix_z370-e_gaming_firmwareb150_pro_gaming\/auraq170m2prime_b250m-kprime_z370-aex-h110m-vh110m-dq170t_v2b150m-plus_firmwaresimatic_ipc647csinumerik_pcu50.5-c_firmwareb150m-a\/m.2_firmwareprime_h110m-p_firmwarez170-pro_firmwaresimatic_ipc847dh110m-k_d3z170-premiumex-b250m-v_firmwarerog_strix_z370-g_gaming_firmwareh110i-plussimatic_ipc477d_pro_firmwareb250m-f_plus_firmwarerog_maximus_viii_rangerh110m-plus_firmwareh110m-f_firmwareex-b150m-vtrooper_h110_d3_firmwarerog_maximus_x_apex_firmwarez170i_pro_gamingsimatic_field_pg_m5_firmwaretrooper_b150_d3simatic_ipc677d_firmwarerog_maximus_ix_apexh110m-a\/dpb150m-c\/brrog_strix_z370-i_gaming_firmwareh170-pro_firmwareb150i_pro_gaming\/wifi\/aura_firmwareh110m-erog_maximus_x_heroh110m-cs_firmwareh110m-cssimatic_field_pg_m4_firmwareh110m-cs_x_firmwareb150m-c_d3rog_maximus_viii_extremeh110s1_firmwaretuf_z270_mark_1z170m-plus\/br_firmwareex-b150m-v3prime_z270-pb150-plus_firmwareprime_z370-p_firmwareq170m2\/cdm\/si_firmwarerog_maximus_ix_formulatuf_z370-pro_gamingh170m-e_d3_firmwareb250m-c_prorog_strix_b250i_gamingrog_strix_z370-h_gamingprime_z270m-plus\/brh110m-ks_firmwareb250-mr_firmwareq170m-cm-b_firmwaresimatic_ipc477e_firmwarerog_strix_h270f_gamingrog_strix_z370-f_gaming_firmwareh110s1prime_h270m-plusz170-p_d3prime_b250m-cz170i_pro_gaming_firmwarerog_maximus_viii_heroh110m-tssimatic_ipc477d_propio-b250i_firmwareq170t_v2_firmwareprime_h270m-plus_firmwareb150m-c\/br_firmwareq170m-crog_maximus_x_codetuf_z370-plus_gamingb250-mrh170-prosimatic_ipc547erog_maximus_viii_formula_firmwareb250m-c_pro_firmwarerog_strix_h270f_gaming_firmwareh170-pro\/usb_3.1z170-p_d3_firmwarerog_maximus_x_apexpio-b250ib150m_pro_gaming_firmwarez170m-plus_firmwaresimatic_ipc547e_firmwaresimatic_ipc827dh110m-c\/psh110m-k_d3_firmwarerog_maximus_viii_hero_alphasimatic_field_pg_m5b150i_pro_gaming\/wifi\/aurarog_strix_z270h_gaming_firmwarerog_maximus_ix_code_firmwareprime_h270-pro_firmwareb150m_pro_gamingh110m-c2\/tfq270m-cm-a_firmwareh110m-c2_firmwarerog_strix_z270e_gamingtuf_z270_mark_2_firmwaresimatic_ipc677c_firmwareprime_b250m-plus\/brq270-s_firmwareh110t_firmwareex-b250m-v3_firmwarez170-ph110m-e\/m.2z170-arh110m-k_xsinumerik_pcu50.5-pb250-s_firmwareprime_z270-asimotion_p320-4s_firmwareprime_b250-plusprime_h270-plussimatic_ipc847d_firmwareh170m-plus\/br_firmwarez170_pro_gamingsimatic_ipc827c_firmwareActive Management Technology
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2024-47904
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.5||HIGH
EPSS-0.03% / 6.23%
||
7 Day CHG~0.00%
Published-23 Oct, 2024 | 14:21
Updated-30 Oct, 2024 | 15:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The affected devices contain a SUID binary that could allow an authenticated local attacker to execute arbitrary commands with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-intermesh_7707_fire_subscriberintermesh_7177_hybrid_2.0_subscriberintermesh_7707_fire_subscriber_firmwareInterMesh 7707 Fire SubscriberInterMesh 7177 Hybrid 2.0 Subscriberintermesh_7177_hybrid2.0_subscriberintermesh_7707_fire_subscriber
CWE ID-CWE-266
Incorrect Privilege Assignment
CVE-2023-30897
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 18.16%
||
7 Day CHG~0.00%
Published-13 Jun, 2023 | 08:17
Updated-03 Jan, 2025 | 01:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC WinCC (All versions < V7.5.2.13). Affected applications fail to set proper access rights for their installation folder if a non-default installation path was chosen during installation. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.

Action-Not Available
Vendor-Siemens AG
Product-winccSIMATIC WinCC
CWE ID-CWE-732
Incorrect Permission Assignment for Critical Resource
CVE-2024-47783
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.5||HIGH
EPSS-0.02% / 4.37%
||
7 Day CHG~0.00%
Published-12 Nov, 2024 | 12:49
Updated-13 Nov, 2024 | 23:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIPORT (All versions < V3.4.0). The affected application improperly assigns file permissions to installation folders. This could allow a local attacker with an unprivileged account to override or modify the service executables and subsequently gain elevated privileges.

Action-Not Available
Vendor-Siemens AG
Product-siportSIPORTsiport_mp
CWE ID-CWE-732
Incorrect Permission Assignment for Critical Resource
CVE-2020-7580
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.7||MEDIUM
EPSS-0.05% / 14.56%
||
7 Day CHG~0.00%
Published-10 Jun, 2020 | 00:00
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.

Action-Not Available
Vendor-Siemens AG
Product-simatic_step_7sinumerik_one_virtualsimatic_pcs_neosimatic_s7-1500_software_controllersimatic_winccsinamics_startdrivesimatic_wincc_open_architecturesimatic_net_pcsinema_serversimatic_wincc_runtime_professionalsimatic_pcs_7sinec_network_management_systemsimatic_automatic_toolsimatic_prosavesinamics_starter_commissioning_toolsinumerik_operatesimatic_wincc_runtime_advancedSIMATIC NET PC Software V14SIMATIC WinCC Runtime AdvancedSIMATIC NET PC Software V15SIMATIC STEP 7 (TIA Portal) V13SIMATIC Automation ToolSIMATIC WinCC Runtime Professional V15SIMATIC WinCC V7.4SIMATIC WinCC V7.5SIMATIC WinCC Runtime Professional V14SINUMERIK ONE virtualSIMATIC STEP 7 (TIA Portal) V16SIMATIC STEP 7 (TIA Portal) V15SIMATIC PCS neoSIMATIC WinCC Runtime Professional V13SINEMA ServerSINUMERIK OperateSINEC NMSSIMATIC S7-1500 Software ControllerSIMATIC WinCC OA V3.17SIMATIC ProSaveSIMATIC NET PC Software V16SIMATIC WinCC OA V3.16SIMATIC STEP 7 V5SIMATIC WinCC Runtime Professional V16SINAMICS STARTERSINAMICS StartdriveSIMATIC STEP 7 (TIA Portal) V14
CWE ID-CWE-428
Unquoted Search Path or Element
CVE-2020-7581
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.7||MEDIUM
EPSS-0.05% / 14.25%
||
7 Day CHG~0.00%
Published-14 Jul, 2020 | 13:18
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.

Action-Not Available
Vendor-Siemens AG
Product-simatic_notifier_serversimatic_step_7opcenter_intelligencesimatic_pcs_neoopcenter_execution_processsoft_starter_esopcenter_qualitysimocode_esopcenter_rd\&lopcenter_execution_discreteopcenter_execution_foundationSIMATIC Notifier Server for WindowsOpcenter Execution DiscreteSoft Starter ES V16Opcenter RD&LSoft Starter ES V15.1Opcenter Execution FoundationSIMATIC STEP 7 (TIA Portal) V16SIMOCODE ES V16Opcenter Execution ProcessSIMOCODE ES V15.1Opcenter QualityOpcenter IntelligenceSIMATIC STEP 7 (TIA Portal) V15SIMATIC PCS neo
CWE ID-CWE-428
Unquoted Search Path or Element
CVE-2022-30527
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.08% / 24.26%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:20
Updated-27 Feb, 2025 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V2.0). The affected application assigns improper access rights to specific folders containing executable files and libraries. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-732
Incorrect Permission Assignment for Critical Resource
CVE-2022-24408
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.03% / 6.54%
||
7 Day CHG~0.00%
Published-08 Mar, 2022 | 11:31
Updated-03 Aug, 2024 | 04:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINUMERIK MC (All versions < V1.15 SP1), SINUMERIK ONE (All versions < V6.15 SP1). The sc SUID binary on affected devices provides several commands that are used to execute system commands or modify system files. A specific set of operations using sc could allow local attackers to escalate their privileges to root.

Action-Not Available
Vendor-Siemens AG
Product-sinumerik_mc_firmwaresinumerik_onesinumerik_one_firmwaresinumerik_mcSINUMERIK MCSINUMERIK ONE
CWE ID-CWE-269
Improper Privilege Management
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 12
  • 13
  • Next
Details not found