Version 1.0.0 of the Instana Dynamic APM Docker image contains a blank password for the root user. Systems deployed using affected versions of the Instana Dynamic APM container may allow a remote attacker to achieve root access with a blank password.
The official Crux Linux Docker images 3.0 through 3.4 contain a blank password for a root user. System using the Crux Linux Docker container deployed by affected versions of the Docker image may allow an attacker to achieve root access with a blank password.
Unrestricted access to the log downloader functionality in EPSON EPS TSE Server 8 (21.0.11) allows an unauthenticated attacker to remotely retrieve administrative hashed credentials via the maintenance/troubleshoot.php?download=1 URI.
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. Attackers can discover cleartext web-server credentials via certain /opt/lighttpd/web/cgi/ requests.
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.
PacsOne Server (PACS Server In One Box) below 7.1.1 is affected by incorrect access control, which can result in remotely gaining administrator privileges.
Zoho ManageEngine ADSelfService Plus through 6113 has an authentication bypass that can be exploited to steal the domain controller session token for identity spoofing, thereby achieving the privileges of the domain controller administrator. NOTE: the vendor's perspective is that they have "found no evidence or detail of a security vulnerability."
An attacker could modify or disable settings, disrupt fuel monitoring and supply chain operations, leading to disabling of ATG monitoring. This would result in potential safety hazards in fuel storage and transportation.
The administrative web interface of mySCADA myPRO Manager can be accessed without authentication which could allow an unauthorized attacker to retrieve sensitive information and upload files without the associated password.
Certain functionality within GMOD Apollo does not require authentication when passed with an administrative username
In SapphireIMS 5.0, it is possible to create local administrator on any client without requiring any credentials by directly accessing RemoteMgmtTaskSave (Automation Tasks) feature and not having a JSESSIONID.
Grandstream GRP261x VoIP phone running firmware version 1.0.3.6 (Base) allow Authentication Bypass in its administrative web interface.
Kapsch TrafficCom RIS-9260 RSU LEO v3.2.0.829.23, v3.8.0.1119.42, and v4.6.0.1211.28 were discovered to contain Android Debug Bridge (ADB) pre-installed (/mnt/c3platpersistent/opt/platform-tools/adb) and enabled by default, allowing unauthenticated root shell access to the cellular modem via the default 'kapsch' user.
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). A service available on port 10005/tcp of the affected devices could allow complete access to all services without authorization. An attacker could gain full control over an affected device, if he has access to this service. The system manual recommends to protect access to this port.
A remote unprivileged attacker can modify and access configuration settings on the EventCam App due to the absence of API authentication. The lack of authentication in the API allows the attacker to potentially compromise the functionality of the EventCam App.
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface.
An issue was discovered in Electerm 1.3.22, allows attackers to execute arbitrary code via unverified request to electerms service.
An issue was discovered in the box application on HiSilicon based IPTV/H.264/H.265 video encoders. The file-upload endpoint does not enforce authentication. Attackers can send an unauthenticated HTTP request to upload a custom firmware component, possibly in conjunction with command injection, to achieve arbitrary code execution.
SICK Package Analytics software up to and including version V04.0.0 are vulnerable to an authentication bypass by directly interfacing with the REST API. An attacker can send unauthorized requests, bypass current authentication controls presented by the application and could potentially write files without authentication.
The BookIt plugin for WordPress is vulnerable to authentication bypass in versions up to, and including, 2.3.7. This is due to insufficient verification on the user being supplied during booking an appointment through the plugin. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, if they have access to the email.
CouchDB version 3.0.0 shipped with a new configuration setting that governs access control to the entire database server called `require_valid_user_except_for_up`. It was meant as an extension to the long standing setting `require_valid_user`, which in turn requires that any and all requests to CouchDB will have to be made with valid credentials, effectively forbidding any anonymous requests. The new `require_valid_user_except_for_up` is an off-by-default setting that was meant to allow requiring valid credentials for all endpoints except for the `/_up` endpoint. However, the implementation of this made an error that lead to not enforcing credentials on any endpoint, when enabled. CouchDB versions 3.0.1[1] and 3.1.0[2] fix this issue.
Vulnerability in the JD Edwards EnterpriseOne Tools product of Oracle JD Edwards (component: Monitoring and Diagnostics SEC). Supported versions that are affected are Prior to 9.2.9.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise JD Edwards EnterpriseOne Tools. Successful attacks of this vulnerability can result in takeover of JD Edwards EnterpriseOne Tools. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
The UI in DevSpace 4.13.0 allows web sites to execute actions on pods (on behalf of a victim) because of a lack of authentication for the WebSocket protocol. This leads to remote code execution.
It is possible to enumerate access card credentials via an unauthenticated network connection to the server in versions of Command Centre v8.20 prior to v8.20.1166(MR3), versions of 8.10 prior to v8.10.1211(MR5), versions of 8.00 prior to v8.00.1228(MR6), all versions of 7.90 and earlier. These credentials can then be used to encode low security cards to be used by the system where insecure card technologies are supported.
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
Swissphone DiCal-RED 4009 devices allow a remote attacker to gain a root shell via TELNET without authentication.
Lack of access control in Nakivo Backup & Replication Transporter version 9.4.0.r43656 allows remote users to access unencrypted backup repositories and the Nakivo Controller configuration via a network accessible transporter service. It is also possible to create or delete backup repositories.
A missing authentication for critical function in Fortinet FortiProxy versions 7.6.0 through 7.6.1, FortiSwitchManager version 7.2.5, and FortiOS versions 7.4.4 through 7.4.6 and version 7.6.0 may allow an attacker with knowledge of an existing admin account to access the device as a valid admin via an authentication bypass.
Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down.
An issue was discovered in BACKCLICK Professional 5.9.63. Due to an exposed internal communications interface, it is possible to execute arbitrary system commands on the server.
An issue was discovered in BACKCLICK Professional 5.9.63. Due to exposed CORBA management services, arbitrary system commands can be executed on the server.
A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device.
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p0_3.2.2.17p0_4.7p0. Direct access to the API is possible on TCP port 8888 via programs located in the cgi-bin folder without any authentication.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.
A vulnerability classified as critical was found in SourceCodester Book Store Management System 1.0. This vulnerability affects unknown code of the file /bsms_ci/index.php. The manipulation leads to improper access controls. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-214588.
Systematic IRIS WebForms 5.4 and its functionalities can be accessed and used without any form of authentication.
Instantel Micromate lacks authentication on a configuration port which could allow an attacker to execute commands if connected.
Multiple W&T products of the ComServer Series are prone to an authentication bypass. An unathenticated remote attacker, can log in without knowledge of the password by crafting a modified HTTP GET Request.
A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
The server permits communication without any authentication procedure, allowing the attacker to initiate a session with the server without providing any form of authentication.
Windows Mobile Device Management Elevation of Privilege Vulnerability
Zoho ManageEngine ServiceDesk Plus before 11302 is vulnerable to authentication bypass that allows a few REST-API URLs without authentication.
Missing Authentication for a Critical Function within the Kratos NGC Indoor Unit (IDU) before 11.4 allows remote attackers to obtain arbitrary control of the IDU/ODU system. Any attacker with layer-3 network access to the IDU can impersonate the Touch Panel Unit (TPU) within the IDU by sending crafted TCP requests to the IDU.
A missing authentication for critical function vulnerability [CWE-306] in FortiPresence infrastructure server before version 1.2.1 allows a remote, unauthenticated attacker to access the Redis and MongoDB instances via crafted authentication requests.
The InWave Jobs plugin for WordPress is vulnerable to privilege escalation via password reset in all versions up to, and including, 3.5.1. This is due to the plugin not properly validating a user's identity prior to updating their password. This makes it possible for unauthenticated attackers to change arbitrary user's passwords, including administrators, and leverage that to gain access to their account.
There are some web interfaces without authentication requirements on D-Link DIR-868L B1-2.03 and DIR-817LW A1-1.04 routers. An attacker can get the router's username and password (and other information) via a DEVICE.ACCOUNT value for SERVICES in conjunction with AUTHORIZED_GROUP=1%0a to getcfg.php. This could be used to control the router remotely.
The Dingtian DT-R0 Series is vulnerable to an exploit that allows attackers to bypass login requirements by directly navigating to the main page.
Orthanc server prior to version 1.5.8 does not enable basic authentication by default when remote access is enabled. This could result in unauthorized access by an attacker.
It was found that default configuration of Heketi does not require any authentication potentially exposing the management interface to misuse. This isue only affects heketi as shipped with Openshift Container Platform 3.11.
Enterprise Cloud Database from Ragic does not authenticate access to specific functionality, allowing unauthenticated remote attackers to use this functionality to obtain any user's session cookie.