Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2020-7571

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-19 Nov, 2020 | 21:02
Updated At-04 Aug, 2024 | 09:33
Rejected At-
Credits

A CWE-79 Multiple Improper Neutralization of Input During Web Page Generation (Cross-site Scripting Reflected) vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause a remote attacker to inject arbitrary web script or HTML due to incorrect sanitization of user supplied data and achieve a Cross-Site Scripting reflected attack against other WebReport users.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
â–¼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:19 Nov, 2020 | 21:02
Updated At:04 Aug, 2024 | 09:33
Rejected At:
â–¼CVE Numbering Authority (CNA)

A CWE-79 Multiple Improper Neutralization of Input During Web Page Generation (Cross-site Scripting Reflected) vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause a remote attacker to inject arbitrary web script or HTML due to incorrect sanitization of user supplied data and achieve a Cross-Site Scripting reflected attack against other WebReport users.

Affected Products
Vendor
n/a
Product
EcoStruxure Building Operation WebReports V1.9 - V3.1
Versions
Affected
  • EcoStruxure Building Operation WebReports V1.9 - V3.1
Problem Types
TypeCWE IDDescription
CWECWE-79CWE-79: Improper Neutralization of Input During Web Page Generation (Cross-siteScripting Stored)
Type: CWE
CWE ID: CWE-79
Description: CWE-79: Improper Neutralization of Input During Web Page Generation (Cross-siteScripting Stored)
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.se.com/ww/en/download/document/SEVD-2020-315-04/
x_refsource_MISC
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2020-315-04/
Resource:
x_refsource_MISC
â–¼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.se.com/ww/en/download/document/SEVD-2020-315-04/
x_refsource_MISC
x_transferred
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2020-315-04/
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
â–¼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:19 Nov, 2020 | 22:15
Updated At:31 Jan, 2022 | 19:45

A CWE-79 Multiple Improper Neutralization of Input During Web Page Generation (Cross-site Scripting Reflected) vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause a remote attacker to inject arbitrary web script or HTML due to incorrect sanitization of user supplied data and achieve a Cross-Site Scripting reflected attack against other WebReport users.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.15.4MEDIUM
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
Primary2.03.5LOW
AV:N/AC:M/Au:S/C:N/I:P/A:N
Type: Primary
Version: 3.1
Base score: 5.4
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
Type: Primary
Version: 2.0
Base score: 3.5
Base severity: LOW
Vector:
AV:N/AC:M/Au:S/C:N/I:P/A:N
CPE Matches

Schneider Electric SE
schneider-electric
>>webreports>>Versions from 1.9(inclusive) to 3.1(inclusive)
cpe:2.3:a:schneider-electric:webreports:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-79Primarycybersecurity@se.com
CWE ID: CWE-79
Type: Primary
Source: cybersecurity@se.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.se.com/ww/en/download/document/SEVD-2020-315-04/cybersecurity@se.com
Patch
Product
Vendor Advisory
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2020-315-04/
Source: cybersecurity@se.com
Resource:
Patch
Product
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

13932Records found

CVE-2024-6528
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-5.4||MEDIUM
EPSS-0.57% / 68.70%
||
7 Day CHG~0.00%
Published-11 Jul, 2024 | 09:03
Updated-01 Aug, 2024 | 21:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a vulnerability leading to a cross-site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload.

Action-Not Available
Vendor-
Product-modicon_m241_firmwaremodicon_m262_firmwaremodicon_m262modicon_lmc058modicon_m241modicon_m258modicon_m258_firmwaremodicon_lmc058_firmwaremodicon_m251_firmwaremodicon_m251Modicon Controllers M262Modicon Controllers M241 / M251Modicon Controllers M258 / LMC058
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2019-6835
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-5.4||MEDIUM
EPSS-0.29% / 52.20%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:13
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Cross-Site Scripting (XSS) CWE-79 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to inject client-side script when a user visits a web page.

Action-Not Available
Vendor-
Product-meg6260-0415_firmwaremeg6260-0410meg6501-0002meg6501-0001_firmwaremeg6260-0410_firmwaremeg6501-0001meg6260-0415meg6501-0002_firmwareU.motion Server
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2022-22804
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-5.4||MEDIUM
EPSS-0.30% / 53.63%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 22:29
Updated-03 Aug, 2024 | 03:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could allow an authenticated attacker to view data, change settings, or impact availability of the software when the user visits a page containing the injected payload. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)

Action-Not Available
Vendor-n/a
Product-ecostruxure_power_monitoring_expertEcoStruxure Power Monitoring Expert (Versions 2020 and prior)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2020-7546
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-5.4||MEDIUM
EPSS-0.30% / 53.57%
||
7 Day CHG~0.00%
Published-01 Dec, 2020 | 14:44
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage.

Action-Not Available
Vendor-n/a
Product-ecostruxure_energy_expertpower_managerpowerscada_expert_with_advanced_reporting_and_dashboardspowerscada_operation_with_advanced_reporting_and_dashboardsecostruxure_power_monitoring_expertEcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2020-7570
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-5.4||MEDIUM
EPSS-0.19% / 40.24%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:02
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting Stored) vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to inject arbitrary web script or HTML due to incorrect sanitization of user-supplied data and achieve a Cross-Site Scripting stored attack against other WebReport users.

Action-Not Available
Vendor-n/a
Product-webreportsEcoStruxure Building Operation WebReports V1.9 - V3.1
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2015-6462
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-5.4||MEDIUM
EPSS-0.38% / 59.26%
||
7 Day CHG~0.00%
Published-21 Mar, 2019 | 18:44
Updated-06 Aug, 2024 | 07:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser.

Action-Not Available
Vendor-n/a
Product-modicon_m340_bmxp342030_firmwaremodicon_m340_bmxp3420302hbmxnoc0401_firmwaremodicon_m340_bmxp3420302h_firmwarebmxnoe0110_firmwarebmxnoe0110hmodicon_m340_bmxp342020h_firmwarebmxnor0200hmodicon_m340_bmxp3420302modicon_m340_bmxp3420302_firmwaremodicon_m340_bmxp342020bmxnoe0100_firmwarebmxnoe0110h_firmwaremodicon_m340_bmxp342030hmodicon_m340_bmxp342020hbmxnoc0401modicon_m340_bmxp342020_firmwaremodicon_m340_bmxp342030h_firmwarebmxnoe0100bmxnor0200h_firmwaremodicon_m340_bmxp342030bmxnoe0110Schneider Electric Modicon PLC
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-22722
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-5.4||MEDIUM
EPSS-0.30% / 53.57%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:43
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Stored Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could cause code injection when importing a CSV file or changing station parameters.

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2014-5411
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-4.9||LOW
EPSS-0.49% / 65.78%
||
7 Day CHG~0.00%
Published-18 Sep, 2014 | 10:00
Updated-06 May, 2026 | 22:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Schneider Electric SCADA Expert ClearSCADA Cross-site Scripting

Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors.

Action-Not Available
Vendor-AVEVASchneider Electric SE
Product-clearscadascada_expert_clearscadaClearSCADASCADA Expert ClearSCADA
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2018-7827
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-5.4||MEDIUM
EPSS-0.23% / 45.28%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 19:33
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Cross-Site Scripting (XSS) vulnerability exists in the 1st Gen. Pelco Sarix Enhanced Camera and Spectra Enhanced PTZ Camera which a remote attacker can execute arbitrary HTML and script code in a user’s browser session.

Action-Not Available
Vendor-n/a
Product-ime219-1ep_firmwareime119-1esime319-1ei_firmwareime219-1vi_firmwareime3122-1vp_firmwareime219-1vs_firmwareime319-1vs_firmwareime219-1esd6220ime219-1vp_firmwareixe31imes19-1eiime3122-1vpimes19-1sime3122-1epime219-1viimes19-1esime319-1eiime3122-1iimes19-1ep_firmwareimes19-1es_firmwared6220_firmwareime3122-b1iimes19-1s_firmwareime3122-b1s_firmwareime119-1vi_firmwared6230_firmwareime319-1s_firmwareime319-b1p_firmwareime319-1pime3122-b1pime319-1ep_firmwareime319-1vsime119-1vp_firmwareime219-1vpime219-1iime3122-1esixe21_firmwareime319-1p_firmwareime3122-1i_firmwareime319-1viimes19-1vsime119-1viimes19-1vp_firmwareime119-1pime3122-1vs_firmwareime219-1es_firmwareime319-1vpimes19-1vpime3122-1eiime319-b1s_firmwareimes19-1ei_firmwareime119-1ei_firmwareime219-1pixe11_firmwareime3122-1ei_firmwareime119-1vpime319-b1iixe31_firmwareime119-1vs_firmwareixes1ime219-1p_firmwareime3122-1ep_firmwareime3122-1vi_firmwareime219-1s_firmwareime119-1vsime119-1es_firmwareimes19-1epime219-1epime319-1vi_firmwareime119-1i_firmwareime119-1eiime319-1iimes19-1iime319-b1sime3122-1p_firmwareimes19-1vi_firmwareimes19-1vs_firmwareime3122-1sime119-1iimes19-1viimes19-1i_firmwareime319-1vp_firmwareime319-1i_firmwareimes19-1pime219-1sime319-b1i_firmwareime3122-1s_firmwareime219-1i_firmwareime3122-1viixe21d6230lime119-1p_firmwareime219-1eiime319-1es_firmwared6230l_firmwareime319-b1pime319-1esd6230ime3122-b1sime219-1ei_firmwareime119-1epd6220lime3122-1vsime219-1vsimes19-1p_firmwareime319-1epime3122-1es_firmwareime119-1sime119-1ep_firmwared6220l_firmwareixes1_firmwareime3122-b1i_firmwareime3122-b1p_firmwareime319-1sixe11ime119-1s_firmwareime3122-1pPelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-22784
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.7||MEDIUM
EPSS-1.43% / 80.75%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system.

Action-Not Available
Vendor-n/a
Product-c-bus_toolkitC-Bus Toolkit v1.15.8 and prior
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2021-22701
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-4.5||MEDIUM
EPSS-0.15% / 35.47%
||
7 Day CHG~0.00%
Published-19 Feb, 2021 | 15:15
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface.

Action-Not Available
Vendor-n/a
Product-powerlogic_ion8650powerlogic_ion8400_firmwarepowerlogic_ion7410powerlogic_pm8000_firmwarepowerlogic_pm8000powerlogic_ion8300_firmwarepowerlogic_ion7400_firmwarepowerlogic_ion7650_firmwarepowerlogic_ion8800powerlogic_ion8600powerlogic_ion8500_firmwarepowerlogic_ion8300powerlogic_ion8500powerlogic_ion8600_firmwarepowerlogic_ion9000_firmwarepowerlogic_ion9000powerlogic_ion8400powerlogic_ion8800_firmwarepowerlogic_ion7400powerlogic_ion7650powerlogic_ion8650_firmwarePowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions)
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)
CVE-2018-7786
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.27% / 49.91%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-17 Sep, 2024 | 02:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric U.motion Builder software versions prior to v1.3.4, a cross site scripting (XSS) vulnerability exists which could allow injection of malicious scripts.

Action-Not Available
Vendor-
Product-u.motion_builderU.motion Builder
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2012-1990
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-4.3||MEDIUM
EPSS-0.39% / 59.78%
||
7 Day CHG~0.00%
Published-22 May, 2012 | 16:00
Updated-29 Apr, 2026 | 01:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric Kerweb before 3.0.1 and Kerwin before 6.0.1 allow remote attackers to inject arbitrary web script or HTML via (1) the evtvariablename parameter in an evts.xml action to kw.dll, (2) unspecified search fields, or (3) unspecified content-display fields.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-kerwebkerwinn/a
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2022-43376
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.6||HIGH
EPSS-0.67% / 71.46%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 19:55
Updated-05 Feb, 2025 | 20:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause code and session manipulation when malicious code is inserted into the browser. Affected Products: NetBotz 4 - 355/450/455/550/570 (V4.7.0 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-netbotz_570_firmwarenetbotz_355netbotz_455_firmwarenetbotz_550netbotz_570netbotz_450netbotz_455netbotz_550_firmwarenetbotz_355_firmwarenetbotz_450_firmwareNetBotz 4 - 355/450/455/550/570
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2017-5157
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.1||MEDIUM
EPSS-0.21% / 42.77%
||
7 Day CHG~0.00%
Published-13 Feb, 2017 | 21:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Schneider Electric homeLYnk Controller, LSS100100, all versions prior to V1.5.0. The homeLYnk controller is susceptible to a cross-site scripting attack. User inputs can be manipulated to cause execution of JavaScript code.

Action-Not Available
Vendor-schneider_electricn/aSchneider Electric SE
Product-homelynk_controller_lss100100homelynk_controller_lss100100_firmwareSchneider Electric homeLYnk Controller prior to V1.5.0
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2012-0930
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.1||MEDIUM
EPSS-1.05% / 77.72%
||
7 Day CHG~0.00%
Published-28 Jan, 2012 | 01:00
Updated-29 Apr, 2026 | 01:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Cross-site scripting (XSS) vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_quantum_plcn/a
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2011-3144
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-4.3||MEDIUM
EPSS-0.54% / 67.86%
||
7 Day CHG~0.00%
Published-16 Aug, 2011 | 21:00
Updated-29 Apr, 2026 | 01:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Cross-site scripting (XSS) vulnerability in Control Microsystems ClearSCADA 2005, 2007, and 2009 before R2.3 and R1.4, as used in SCX before 67 R4.5 and 68 R3.9, allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.

Action-Not Available
Vendor-n/aAVEVASchneider Electric SE
Product-scx_67clearscadascx_68n/a
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2023-5985
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-4.8||MEDIUM
EPSS-0.15% / 34.57%
||
7 Day CHG~0.00%
Published-15 Nov, 2023 | 03:35
Updated-29 Aug, 2024 | 15:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability exists that could cause compromise of a user’s browser when an attacker with admin privileges has modified system values.

Action-Not Available
Vendor-
Product-ion8650_firmwareion8800ion8650ion8800_firmwareION8650ION8800
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2011-4035
Matching Score-6
Assigner-CERT/CC
ShareView Details
Matching Score-6
Assigner-CERT/CC
CVSS Score-4.3||MEDIUM
EPSS-2.09% / 84.16%
||
7 Day CHG~0.00%
Published-02 Dec, 2011 | 11:00
Updated-29 Apr, 2026 | 01:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Cross-site scripting (XSS) vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-citecthistorianvijeo_historiancitectscada_reportsn/a
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2020-28210
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.37% / 59.11%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:01
Updated-04 Aug, 2024 | 16:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user's browser.

Action-Not Available
Vendor-n/a
Product-ecostruxure_building_operationEcoStruxure Building Operation WebStation V2.0 - V3.1
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2023-25551
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.53% / 67.17%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:37
Updated-12 Feb, 2025 | 16:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE file upload endpoint when tampering with parameters over HTTP. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2023-25553
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.53% / 67.17%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:38
Updated-05 Feb, 2025 | 21:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE endpoint through the logging capabilities of the webserver. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2019-6853
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.30% / 53.46%
||
7 Day CHG~0.00%
Published-20 Nov, 2019 | 22:01
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Failure to Preserve Web Page Structure vulnerability exists in Andover Continuum (models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702) , which could enable a successful Cross-site Scripting (XSS attack) when using the products web server.

Action-Not Available
Vendor-
Product-andover_continuum_9941_firmwareandover_continuum_5720_firmwareandover_continuum_9924andover_continuum_9900_firmwareandover_continuum_5740_firmwareandover_continuum_9940andover_continuum_bcx9640andover_continuum_9702andover_continuum_9900andover_continuum_9924_firmwareandover_continuum_9680andover_continuum_9702_firmwareandover_continuum_9941andover_continuum_bcx9640_firmwareandover_continuum_9940_firmwareandover_continuum_5740andover_continuum_9200_firmwareandover_continuum_bcx4040_firmwareandover_continuum_bcx4040andover_continuum_9200andover_continuum_9680_firmwareandover_continuum_5720Andover Continuum models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2022-22812
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.32% / 54.77%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:05
Updated-03 Aug, 2024 | 03:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a web session compromise when an attacker injects and then executes arbitrary malicious JavaScript code inside the target browser. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)

Action-Not Available
Vendor-n/a
Product-fellerlynkwiser_for_knxspacelynkwiser_for_knx_firmwarefellerlynk_firmwarespacelynk_firmwarespaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-22813
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.49% / 65.73%
||
7 Day CHG~0.00%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)

Action-Not Available
Vendor-n/a
Product-single-phase_symmetragalaxy_g9kchupdpm138h-5upd60f6fk1pdpm277hpd40e5ek20-mpd40l6fk1-msymmetra_px_20galaxy_gvmsapd60g6fk1gutor_gvxgalaxy_3500network_management_card_2_firmwarepdpm150g6fpdrppnx10pdpb150g6fpmm500-alaxgutor_sxwpdpm150l6fpdpm175g6hapc_rack_power_distribution_unitspd60l6fk1pdpm288g6hnetwork_management_card_3pdpm138h-rpdrppnx10mpd40f6fk1-mrack_automatic_transfer_switchessmart-upspd40h5ek20-mnetwork_management_card_2symmetra_px_160pmm400-alaxsymmetra_px_40symmetra_px_48netbotz_nbrk0250pmm400-alagalaxy_g7xnetwork_management_card_3_firmwarepdpm144fpmm400-cubgalaxy_gfcgalaxy_rpp_grppip2x84ap9922_battery_management_systemsymmetra_px_100symmetra_px_500galaxy_gcxsagalaxy_gvxtssymmetra_px_250symmetra_px_96pmm500-cubpd40g6fk1-mgalaxy_gvmtspmm500-alapdpm72f-5un/a
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-22706
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.29% / 52.01%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:41
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server.

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-22810
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.49% / 65.73%
||
7 Day CHG~0.00%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)

Action-Not Available
Vendor-n/a
Product-single-phase_symmetragalaxy_g9kchupdpm138h-5upd60f6fk1pdpm277hpd40e5ek20-mpd40l6fk1-msymmetra_px_20galaxy_gvmsapd60g6fk1gutor_gvxgalaxy_3500network_management_card_2_firmwarepdpm150g6fpdrppnx10pdpb150g6fpmm500-alaxgutor_sxwpdpm150l6fpdpm175g6hapc_rack_power_distribution_unitspd60l6fk1pdpm288g6hnetwork_management_card_3pdpm138h-rpdrppnx10mpd40f6fk1-mrack_automatic_transfer_switchessmart-upspd40h5ek20-mnetwork_management_card_2symmetra_px_160pmm400-alaxsymmetra_px_40symmetra_px_48netbotz_nbrk0250pmm400-alagalaxy_g7xnetwork_management_card_3_firmwarepdpm144fpmm400-cubgalaxy_gfcgalaxy_rpp_grppip2x84ap9922_battery_management_systemsymmetra_px_100symmetra_px_500galaxy_gcxsagalaxy_gvxtssymmetra_px_250symmetra_px_96pmm500-cubpd40g6fk1-mgalaxy_gvmtspmm500-alapdpm72f-5un/a
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-22811
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.49% / 65.73%
||
7 Day CHG~0.00%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)

Action-Not Available
Vendor-n/a
Product-single-phase_symmetragalaxy_g9kchupdpm138h-5upd60f6fk1pdpm277hpd40e5ek20-mpd40l6fk1-msymmetra_px_20galaxy_gvmsapd60g6fk1gutor_gvxgalaxy_3500network_management_card_2_firmwarepdpm150g6fpdrppnx10pdpb150g6fpmm500-alaxgutor_sxwpdpm150l6fpdpm175g6hapc_rack_power_distribution_unitspd60l6fk1pdpm288g6hnetwork_management_card_3pdpm138h-rpdrppnx10mpd40f6fk1-mrack_automatic_transfer_switchessmart-upspd40h5ek20-mnetwork_management_card_2symmetra_px_160pmm400-alaxsymmetra_px_40symmetra_px_48netbotz_nbrk0250pmm400-alagalaxy_g7xnetwork_management_card_3_firmwarepdpm144fpmm400-cubgalaxy_gfcgalaxy_rpp_grppip2x84ap9922_battery_management_systemsymmetra_px_100symmetra_px_500galaxy_gcxsagalaxy_gvxtssymmetra_px_250symmetra_px_96pmm500-cubpd40g6fk1-mgalaxy_gvmtspmm500-alapdpm72f-5un/a
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-22812
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.49% / 65.73%
||
7 Day CHG~0.00%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)

Action-Not Available
Vendor-n/a
Product-single-phase_symmetragalaxy_g9kchupdpm138h-5upd60f6fk1pdpm277hpd40e5ek20-mpd40l6fk1-msymmetra_px_20galaxy_gvmsapd60g6fk1gutor_gvxgalaxy_3500network_management_card_2_firmwarepdpm150g6fpdrppnx10pdpb150g6fpmm500-alaxgutor_sxwpdpm150l6fpdpm175g6hapc_rack_power_distribution_unitspd60l6fk1pdpm288g6hnetwork_management_card_3pdpm138h-rpdrppnx10mpd40f6fk1-mrack_automatic_transfer_switchessmart-upspd40h5ek20-mnetwork_management_card_2symmetra_px_160pmm400-alaxsymmetra_px_40symmetra_px_48netbotz_nbrk0250pmm400-alagalaxy_g7xnetwork_management_card_3_firmwarepdpm144fpmm400-cubgalaxy_gfcgalaxy_rpp_grppip2x84ap9922_battery_management_systemsymmetra_px_100symmetra_px_500galaxy_gcxsagalaxy_gvxtssymmetra_px_250symmetra_px_96pmm500-cubpd40g6fk1-mgalaxy_gvmtspmm500-alapdpm72f-5un/a
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-22822
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.32% / 54.77%
||
7 Day CHG~0.00%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79 Improper Neutralization of Input During Web Page Generation (�Cross-site Scripting�) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evp2pe_firmwareevlink_parking_evf2_firmwareevlink_parking_evw2evlink_parking_evp2peevlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_city_evc1s7p4n/a
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2020-7481
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.32% / 54.77%
||
7 Day CHG~0.00%
Published-23 Mar, 2020 | 19:23
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could enable a successful Cross-site Scripting (XSS attack) when using the products' web server.

Action-Not Available
Vendor-n/a
Product-andover_continuum_9941_firmwareandover_continuum_5720_firmwareandover_continuum_9924andover_continuum_9900_firmwareandover_continuum_5740_firmwareandover_continuum_9940andover_continuum_bcx9640andover_continuum_9702andover_continuum_9900andover_continuum_9924_firmwareandover_continuum_9680andover_continuum_9702_firmwareandover_continuum_9941andover_continuum_bcx9640_firmwareandover_continuum_9940_firmwareandover_continuum_5740andover_continuum_9200_firmwareandover_continuum_bcx4040_firmwareandover_continuum_bcx4040andover_continuum_9200andover_continuum_9680_firmwareandover_continuum_5720Andover Continuum (All versions)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2020-7482
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.32% / 54.77%
||
7 Day CHG~0.00%
Published-23 Mar, 2020 | 19:23
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could cause a Reflective Cross-site Scripting (XSS attack) when using the products' web server.

Action-Not Available
Vendor-n/a
Product-andover_continuum_9941_firmwareandover_continuum_5720_firmwareandover_continuum_9924andover_continuum_9900_firmwareandover_continuum_5740_firmwareandover_continuum_9940andover_continuum_bcx9640andover_continuum_9702andover_continuum_9900andover_continuum_9924_firmwareandover_continuum_9680andover_continuum_9702_firmwareandover_continuum_9941andover_continuum_bcx9640_firmwareandover_continuum_9940_firmwareandover_continuum_5740andover_continuum_9200_firmwareandover_continuum_bcx4040_firmwareandover_continuum_bcx4040andover_continuum_9200andover_continuum_9680_firmwareandover_continuum_5720Andover Continuum (All versions)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2016-4513
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.1||MEDIUM
EPSS-0.34% / 56.58%
||
7 Day CHG~0.00%
Published-26 Jun, 2016 | 01:00
Updated-06 May, 2026 | 22:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Cross-site scripting (XSS) vulnerability in the Schneider Electric PowerLogic PM8ECC module before 2.651 for PowerMeter 800 devices allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-powerlogic_pm8eccpowerlogic_pm8ecc_firmwaren/a
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2023-5987
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.12% / 30.56%
||
7 Day CHG~0.00%
Published-15 Nov, 2023 | 03:48
Updated-02 Aug, 2024 | 08:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload.

Action-Not Available
Vendor-
Product-ecostruxure_power_monitoring_expertEcoStruxure Power Monitoring Expert (PME)EcoStruxure Power Operation (EPO) – Advanced Reporting and Dashboards ModuleEcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-22723
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.32% / 54.77%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:43
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation (Cross-siteScripting) through Cross-Site Request Forgery (CSRF) vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server.

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-22814
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.49% / 65.73%
||
7 Day CHG~0.00%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)

Action-Not Available
Vendor-n/a
Product-single-phase_symmetragalaxy_g9kchupdpm138h-5upd60f6fk1pdpm277hpd40e5ek20-mpd40l6fk1-msymmetra_px_20galaxy_gvmsapd60g6fk1gutor_gvxgalaxy_3500network_management_card_2_firmwarepdpm150g6fpdrppnx10pdpb150g6fpmm500-alaxgutor_sxwpdpm150l6fpdpm175g6hapc_rack_power_distribution_unitspd60l6fk1pdpm288g6hnetwork_management_card_3pdpm138h-rpdrppnx10mpd40f6fk1-mrack_automatic_transfer_switchessmart-upspd40h5ek20-mnetwork_management_card_2symmetra_px_160pmm400-alaxsymmetra_px_40symmetra_px_48netbotz_nbrk0250pmm400-alagalaxy_g7xnetwork_management_card_3_firmwarepdpm144fpmm400-cubgalaxy_gfcgalaxy_rpp_grppip2x84ap9922_battery_management_systemsymmetra_px_100symmetra_px_500galaxy_gcxsagalaxy_gvxtssymmetra_px_250symmetra_px_96pmm500-cubpd40g6fk1-mgalaxy_gvmtspmm500-alapdpm72f-5un/a
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2018-7810
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.31% / 54.36%
||
7 Day CHG~0.00%
Published-30 Nov, 2018 | 19:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to craft a URL containing JavaScript that will be executed within the user's browser, potentially impacting the machine the browser is running on.

Action-Not Available
Vendor-
Product-modicom_bmxnor0200hmodicom_quantum_firmwaremodicom_premiummodicom_bmxnor0200h_firmwaremodicom_m340_firmwaremodicom_m340modicom_quantummodicom_premium_firmwareEmbedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2018-7795
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.31% / 54.26%
||
7 Day CHG~0.00%
Published-29 Aug, 2018 | 20:00
Updated-16 Sep, 2024 | 17:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Cross Protocol Injection vulnerability exists in Schneider Electric's PowerLogic (PM5560 prior to FW version 2.5.4) product. The vulnerability makes the product susceptible to cross site scripting attack on its web browser. User inputs can be manipulated to cause execution of java script code.

Action-Not Available
Vendor-
Product-powerlogic_pm5560powerlogic_pm5560_firmwarePowerLogic - PM5560 prior to FW version 2.5.4
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2018-7834
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.1||MEDIUM
EPSS-0.27% / 50.01%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 19:49
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-79 Cross-Site Scripting vulnerability exists in all versions of the TSXETG100 allowing an attacker to send a specially crafted URL with an embedded script to a user that would then be executed within the context of that user.

Action-Not Available
Vendor-n/a
Product-tsxetg100tsxetg100_firmwareConneXium Gateway, TSXETG100 - all versions
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2018-7831
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.22% / 44.84%
||
7 Day CHG~0.00%
Published-30 Nov, 2018 | 19:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to send a specially crafted URL to a currently authenticated web server user to execute a password change on the web server.

Action-Not Available
Vendor-
Product-modicom_bmxnor0200hmodicom_quantum_firmwaremodicom_premiummodicom_bmxnor0200h_firmwaremodicom_m340_firmwaremodicom_m340modicom_quantummodicom_premium_firmwareEmbedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)
CVE-2022-44590
Matching Score-4
Assigner-Patchstack
ShareView Details
Matching Score-4
Assigner-Patchstack
CVSS Score-5.4||MEDIUM
EPSS-0.18% / 39.32%
||
7 Day CHG+0.01%
Published-09 Nov, 2022 | 21:14
Updated-28 Apr, 2026 | 19:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WordPress Simple Video Embedder plugin <= 2.2 - Auth. Stored Cross-Site Scripting (XSS) vulnerability

Auth. (contributor+) Stored Cross-Site Scripting (XSS) vulnerability in James Lao's Simple Video Embedder plugin <= 2.2 on WordPress.

Action-Not Available
Vendor-simple_video_embedder_projectJames Lao
Product-simple_video_embedderSimple Video Embedder (WordPress plugin)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2023-5362
Matching Score-4
Assigner-Wordfence
ShareView Details
Matching Score-4
Assigner-Wordfence
CVSS Score-6.4||MEDIUM
EPSS-0.08% / 23.91%
||
7 Day CHG~0.00%
Published-30 Oct, 2023 | 13:49
Updated-08 Apr, 2026 | 19:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Carousel, Recent Post Slider and Banner Slider <= 2.0 - Authenticated (Contributor+) Stored Cross-Site Scripting via Shortcode

The Carousel, Recent Post Slider and Banner Slider plugin for WordPress is vulnerable to Stored Cross-Site Scripting via 'spice_post_slider' shortcode in versions up to, and including, 2.0 due to insufficient input sanitization and output escaping on user supplied attributes. This makes it possible for authenticated attackers with contributor-level and above permissions to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page.

Action-Not Available
Vendor-spicethemesspicethemes
Product-carousel\,_recent_post_slider_and_banner_sliderCarousel, Recent Post Slider and Banner Slider
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2023-53897
Matching Score-4
Assigner-VulnCheck
ShareView Details
Matching Score-4
Assigner-VulnCheck
CVSS Score-5.1||MEDIUM
EPSS-0.05% / 14.32%
||
7 Day CHG~0.00%
Published-16 Dec, 2025 | 17:03
Updated-07 Apr, 2026 | 14:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Rukovoditel 3.4.1 Multiple Stored Cross-Site Scripting via Comments

Rukovoditel 3.4.1 contains multiple stored cross-site scripting vulnerabilities that allow authenticated attackers to inject malicious scripts. Attackers can insert XSS payloads in project task comments to execute arbitrary JavaScript in victim browsers.

Action-Not Available
Vendor-rukovoditelRukovoditel
Product-rukovoditelRukovoditel
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2022-4467
Matching Score-4
Assigner-WPScan
ShareView Details
Matching Score-4
Assigner-WPScan
CVSS Score-5.4||MEDIUM
EPSS-0.18% / 39.40%
||
7 Day CHG~0.00%
Published-23 Jan, 2023 | 14:31
Updated-02 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Search & Filter < 1.2.16 - Contributor+ Stored XSS

The Search & Filter WordPress plugin before 1.2.16 does not validate and escape some of its shortcode attributes before outputting them back in the page, which could allow users with a role as low as contributor to perform Stored Cross-Site Scripting attacks which could be used against high privilege users such as admin.

Action-Not Available
Vendor-codeampUnknown
Product-search_\&_filterSearch & Filter
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2018-7302
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-5.4||MEDIUM
EPSS-0.21% / 42.62%
||
7 Day CHG~0.00%
Published-21 Feb, 2018 | 20:00
Updated-16 Sep, 2024 | 17:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tiki 17.1 allows upload of a .PNG file that actually has SVG content, leading to XSS.

Action-Not Available
Vendor-tikin/a
Product-tikin/a
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2020-5765
Matching Score-4
Assigner-Tenable Network Security, Inc.
ShareView Details
Matching Score-4
Assigner-Tenable Network Security, Inc.
CVSS Score-5.4||MEDIUM
EPSS-0.38% / 59.54%
||
7 Day CHG~0.00%
Published-15 Jul, 2020 | 12:18
Updated-04 Aug, 2024 | 08:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Nessus 8.10.0 and earlier were found to contain a Stored XSS vulnerability due to improper validation of input during scan configuration. An authenticated, remote attacker could potentially exploit this vulnerability to execute arbitrary code in a user's session. Tenable has implemented additional input validation mechanisms to correct this issue in Nessus 8.11.0.

Action-Not Available
Vendor-n/aTenable, Inc.
Product-nessusTenable Nessus
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2023-53920
Matching Score-4
Assigner-VulnCheck
ShareView Details
Matching Score-4
Assigner-VulnCheck
CVSS Score-5.1||MEDIUM
EPSS-0.05% / 14.32%
||
7 Day CHG~0.00%
Published-17 Dec, 2025 | 22:44
Updated-07 Apr, 2026 | 14:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
PodcastGenerator Stored Cross-Site Scripting via Podcast Title Field

PodcastGenerator 3.2.9 contains a stored cross-site scripting vulnerability in the podcast title field accessible through the podcast details interface (podcast_details.php). Malicious JavaScript payloads injected into the podcast title execute when users visit the application's home page.

Action-Not Available
Vendor-podcastgeneratorPodcastgenerator
Product-podcast_generatorPodcastGenerator
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2023-53890
Matching Score-4
Assigner-VulnCheck
ShareView Details
Matching Score-4
Assigner-VulnCheck
CVSS Score-5.1||MEDIUM
EPSS-0.05% / 16.23%
||
7 Day CHG~0.00%
Published-15 Dec, 2025 | 20:28
Updated-07 Apr, 2026 | 14:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Perch CMS 3.2 Stored Cross-Site Scripting via SVG File Upload

Perch CMS 3.2 contains a stored cross-site scripting vulnerability that allows authenticated users to upload malicious SVG files with embedded JavaScript. Attackers can craft SVG files with script tags that execute when the file is viewed, potentially stealing user session information or performing client-side attacks.

Action-Not Available
Vendor-grabaperchPerch
Product-perchPerch
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2022-4542
Matching Score-4
Assigner-WPScan
ShareView Details
Matching Score-4
Assigner-WPScan
CVSS Score-5.4||MEDIUM
EPSS-0.20% / 41.59%
||
7 Day CHG~0.00%
Published-23 Jan, 2023 | 14:31
Updated-03 Apr, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Compact WP Audio Player < 1.9.8 - Contributor+ Stored XSS

The Compact WP Audio Player WordPress plugin before 1.9.8 does not validate and escape some of its shortcode attributes before outputting them back in the page, which could allow users with a role as low as contributor to perform Stored Cross-Site Scripting attacks which could be used against high privilege users such as admins.

Action-Not Available
Vendor-UnknownTips and Tricks HQ
Product-compact_wp_audio_playerCompact WP Audio Player
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2025-22618
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-6.4||MEDIUM
EPSS-0.51% / 66.44%
||
7 Day CHG~0.00%
Published-13 Jan, 2025 | 20:50
Updated-13 Feb, 2025 | 18:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WeGIA Cross-Site Scripting (XSS) Stored endpoint 'adicionar_cargo.php' parameter 'cargo'

WeGIA is an open source web manager with a focus on the Portuguese language and charitable institutions. A Stored Cross-Site Scripting (XSS) vulnerability was identified in the `adicionar_cargo.php` endpoint of the WeGIA application. This vulnerability allows attackers to inject malicious scripts into the `cargo` parameter. The injected scripts are stored on the server and executed automatically whenever the affected page is accessed by users, posing a significant security risk. The application fails to properly validate and sanitize user inputs in the `adicionar_cargo.php` parameter. This lack of validation allows attackers to inject malicious scripts, which are then stored on the server. Whenever the affected page is accessed, the malicious payload is executed in the victim's browser, potentially compromising the user's data and system. This issue has been addressed in release version 3.2.6 and all users are advised to upgrade. There are no known workarounds for this vulnerability.

Action-Not Available
Vendor-wegiaLabRedesCefetRJ
Product-wegiaWeGIA
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 278
  • 279
  • Next
Details not found