Insufficient protection of the inter-process communication functions in ABB System 800xA RNRP (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
Insufficient protection of the inter-process communication functions in ABB System 800xA Batch Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting User Interface update during batch execution and/or compare/printing functionalities.
Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
Insufficient protection of the inter-process communication functions in ABB System 800xA Base (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
Improper Privilege Management vulnerability in ABB Ltd. ASPECT®-Enterprise on ASPECT®-Enterprise, Linux (2CQG103201S3021, 2CQG103202S3021, 2CQG103203S3021, 2CQG103204S3021 modules), ABB Ltd. NEXUS Series on NEXUS Series, Linux (2CQG100102R2021, 2CQG100104R2021, 2CQG100105R2021, 2CQG100106R2021, 2CQG100110R2021, 2CQG100112R2021, 2CQG100103R2021, 2CQG100107R2021, 2CQG100108R2021, 2CQG100109R2021, 2CQG100111R2021, 2CQG100113R2021 modules), ABB Ltd. MATRIX Series on MATRIX Series, Linux (2CQG100102R1021, 2CQG100103R1021, 2CQG100104R1021, 2CQG100105R1021, 2CQG100106R1021 modules) allows Privilege Escalation.This issue affects ASPECT®-Enterprise: from 3.0;0 before 3.07.01; NEXUS Series: from 3.0;0 before 3.07.01; MATRIX Series: from 3.0;0 before 3.07.01.
An attacker could exploit the vulnerability by injecting garbage data or specially crafted data. Depending on the data injected each process might be affected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing the product to store wrong information or act on wrong data or display wrong information. This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2. For an attack to be successful, the attacker must have local access to a node in the system and be able to start a specially crafted application that disrupts the communication. An attacker who successfully exploited the vulnerability would be able to manipulate the data in such way as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300 and AdvaBuild to crash.
Incorrect Permission Assignment for Critical Resource vulnerability in ABB Automation Builder.This issue affects Automation Builder: through 2.8.0.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Incorrect Default Permissions vulnerability in ABB e-Design allows attacker to install malicious software executing with SYSTEM permissions violating confidentiality, integrity, and availability of the target machine.
Vulnerabilities in the Mint WorkBench allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Mint WorkBench installer file allows a low-privileged user to run a "repair" operation on the product
Unquoted Search Path or Element vulnerability in ABB Mint Workbench. A local attacker who successfully exploited this vulnerability could gain elevated privileges by inserting an executable file in the path of the affected service. This issue affects Mint Workbench I versions: from 5866 before 5868.
Insufficient folder permissions used by system functions in ABB System 800xA Base (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploit the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications.
Insecure storage of sensitive information in ABB Device Library Wizard versions 6.0.X, 6.0.3.1 and 6.0.3.2 allows unauthenticated low privilege user to read file that contains confidential data
In Symphony Plus Operations and Symphony Plus Historian, some services can be vulnerable to privilege escalation attacks. An unprivileged (but authenticated) user could execute arbitrary code and result in privilege escalation, depending on the user that the service runs as.
In S+ Operations and S+ Historian, the passwords of internal users (not Windows Users) are encrypted but improperly stored in a database.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Insertion of Sensitive Information into Log File vulnerability in ABB QCS 800xA, ABB QCS AC450, ABB Platform Engineering Tools. An attacker, who already has local access to the QCS nodes, could successfully obtain the password for a system user account. Using this information, the attacker could have the potential to exploit this vulnerability to gain control of system nodes. This issue affects QCS 800xA: from 1.0;0 through 6.1SP2; QCS AC450: from 1.0;0 through 5.1SP2; Platform Engineering Tools: from 1.0:0 through 2.3.0.
Weak Registry permissions in ABB System 800xA Base allow low privileged users to read and modify registry settings related to control system functionality, allowing an authenticated attacker to cause system functions to stop or malfunction.
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code.
Replay Attack in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to capture/replay KNX telegram to local KNX Bus-System
A certificate validation vulnerability in PCM600 Update Manager allows attacker to get unwanted software packages to be installed on computer which has PCM600 installed.
Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and earlier) and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploited the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications.
Improper implementation of Access Control in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows an unauthorized user to access data marked as restricted, such as viewing or editing user profiles and application settings.
The Configuration pages in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway for user profiles and services transfer the password in plaintext (although hidden when displayed).
Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder.
A Permissions, Privileges, and Access Controls issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. The web application does not properly restrict privileges of the Guest account. A malicious user may be able to gain access to configuration information that should be restricted.
The "Protect Worksheet" functionality in Mathsoft Mathcad 12 through 13.1, and PTC Mathcad 14, implements file access restrictions via a protection element in a gzipped XML file, which allows attackers to bypass these restrictions by removing this element.
Cosminexus Manager in Cosminexus Application Server 07-00 and later might assign the wrong user's group permissions to logical user server processes, which allows local users to gain privileges.
A local privilege escalation vulnerability in the famtd component of Micro Focus Filr 3.0 allows a local attacker authenticated as a low privilege user to escalate to root. This vulnerability affects all versions of Filr 3.x prior to Security Update 6.
Privilege Escalation vulnerability in McAfee FRP 5.x prior to 5.1.0.209 allows local users to gain elevated privileges via running McAfee Tray with elevated privileges.
A vulnerability in the routine that loads DLL files in Cisco Meeting App for Windows could allow an authenticated, local attacker to run an executable file with privileges equivalent to those of Cisco Meeting App. The vulnerability is due to incomplete input validation of the path name for DLL files before they are loaded. An attacker could exploit this vulnerability by installing a crafted DLL file in a specific system directory. A successful exploit could allow the attacker to execute commands on the underlying Microsoft Windows host with privileges equivalent to those of Cisco Meeting App. The attacker would need valid user credentials to exploit this vulnerability. Cisco Bug IDs: CSCvd77907.
A vulnerability in the guest shell feature of Cisco NX-OS System Software could allow an authenticated, local attacker to read and send packets outside the scope of the guest shell container. An attacker would need valid administrator credentials to perform this attack. The vulnerability is due to insufficient internal security measures in the guest shell feature. An attacker could exploit this vulnerability by sending or receiving packets on the device-internal network outside of the guest shell container, aka "Unauthorized Internal Interface Access." This vulnerability affects the following products running Cisco NX-OS System Software: Nexus 3000 Series Switches, Nexus 9000 Series Switches in standalone NX-OS mode, Nexus 9500 R-Series Line Cards and Fabric Modules. Cisco Bug IDs: CSCvf33038.
A vulnerability in the Open Agent Container (OAC) feature of Cisco Nexus Series Switches could allow an unauthenticated, local attacker to read and send packets outside the scope of the OAC. The vulnerability is due to insufficient internal security measures in the OAC feature. An attacker could exploit this vulnerability by crafting specific packets for communication on the device-internal network. A successful exploit could allow the attacker to run code on the underlying host operating system. OAC is not enabled by default. For a device to be vulnerable, an administrator would need to install and activate this feature. This vulnerability affects the following Cisco Nexus Series Switches: Nexus 2000 Series Fabric Extenders, Nexus 5000 Series Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches. Cisco Bug IDs: CSCve53542, CSCvf36621.
Barron McCann X-Kryptor Driver BMS1446HRR (Xgntr BMS1351 Install BMS1472) in X-Kryptor Secure Client does not drop privileges when launching an Explorer window in response to a help command, which allows local users to gain LocalSystem privileges via interactive use of Explorer.
In cPanel before 67.9999.103, the backup system overwrites root's home directory when a mount disappears (SEC-299).
The ReadDirectoryChangesW API function on Microsoft Windows 2000, XP, Server 2003, and Vista does not check permissions for child objects, which allows local users to bypass permissions by opening a directory with LIST (READ) access and using ReadDirectoryChangesW to monitor changes of files that do not have LIST permissions, which can be leveraged to determine filenames, access times, and other sensitive information.
hald in Sun OpenSolaris snv_51 through snv_130 does not have the proc_audit privilege during unspecified attempts to write to the auditing log, which makes it easier for physically proximate attackers to avoid detection of changes to the set of connected hardware devices supporting the Hardware Abstraction Layer (HAL) specification.
The Shibboleth authentication module 5.x before 5.x-3.4 and 6.x before 6.x-3.2, a module for Drupal, does not properly remove statically granted privileges after a logout or other session change, which allows physically proximate attackers to gain privileges by using an unattended web browser.
The Self Tuning Memory Manager (STMM) component in IBM DB2 9.1 before FP8, 9.5 before FP5, and 9.7 before FP1 uses 0666 permissions for the STMM log file, which allows local users to cause a denial of service or have unspecified other impact by writing to this file.
dasauto in IBM DB2 8 before FP18, 9.1 before FP8, 9.5 before FP4, and 9.7 before FP1 permits execution by unprivileged user accounts, which has unspecified impact and local attack vectors.
The NtUserConsoleControl function in win32k.sys in Microsoft Windows XP SP2 and SP3, and Server 2003 before SP1, allows local administrators to bypass unspecified "security software" and gain privileges via a crafted call that triggers an overwrite of an arbitrary memory location. NOTE: the vendor disputes the significance of this report, stating that 'the Administrator to SYSTEM "escalation" is not a security boundary we defend.
nilfs-utils before 2.0.14 installs multiple programs with unnecessary setuid privileges, which allows local users to execute arbitrary commands via the device string in a -c command line option to mkfs.nilfs2.
NFSv4 in the Linux kernel 2.6.18, and possibly other versions, does not properly clean up an inode when an O_EXCL create fails, which causes files to be created with insecure settings such as setuid bits, and possibly allows local users to gain privileges, related to the execution of the do_open_permission function even when a create fails.
The kernel in NetBSD, probably 5.0.1 and earlier, on x86 platforms does not properly handle a pre-commit failure of the iret instruction, which might allow local users to gain privileges via vectors related to a tempEIP pseudocode variable that is outside of the code-segment limits.
Jboss jbossas before versions 5.2.0-23, 6.4.13, 7.0.5 is vulnerable to an unsafe file handling in the jboss init script which could result in local privilege escalation.
xvfb-run 1.6.1 in Debian GNU/Linux, Ubuntu, Fedora 10, and possibly other operating systems place the magic cookie (MCOOKIE) on the command line, which allows local users to gain privileges by listing the process and its arguments.
The kill_something_info function in kernel/signal.c in the Linux kernel before 2.6.28 does not consider PID namespaces when processing signals directed to PID -1, which allows local users to bypass the intended namespace isolation, and send arbitrary signals to all processes in all namespaces, via a kill command.