A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface.
newbee-mall all versions are affected by incorrect access control to remotely gain privileges through AdminLoginInterceptor.java. The authentication logic of the system's background /admin is in code AdminLoginInterceptor, which can be bypassed.
An issue was discovered in Heimdal Thor agent versions 3.4.2 and before on Windows and 2.6.9 and before on macOS, allows attackers to bypass network filtering, execute arbitrary code, and obtain sensitive information via DarkLayer Guard threat prevention module. NOTE: Heimdal disputes the validity of this issue arguing that their DNS Security for Endpoint filters DNS traffic on the endpoint by intercepting system-generated DNS requests. The product was not designed to intercept DNS requests from third-party solutions.
Swissphone DiCal-RED 4009 devices allow a remote attacker to gain a root shell via TELNET without authentication.
Moxa MiiNePort E1 has a vulnerability of insufficient access control. An unauthenticated remote user can exploit this vulnerability to perform arbitrary system operation or disrupt service.
The BookIt plugin for WordPress is vulnerable to authentication bypass in versions up to, and including, 2.3.7. This is due to insufficient verification on the user being supplied during booking an appointment through the plugin. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, if they have access to the email.
VR CAM P1 Model P1 v1 has an incorrect access control vulnerability where an attacker can obtain complete access of the device from web (remote) without authentication.
Cybele Software Thinfinity Workspace before v7.0.2.113 was discovered to contain an access control issue in the API endpoint where Web Sockets connections are established.
NUUO NVRmini2 through 3.11 allows an unauthenticated attacker to upload an encrypted TAR archive, which can be abused to add arbitrary users because of the lack of handle_import_user.php authentication. When combined with another flaw (CVE-2011-5325), it is possible to overwrite arbitrary files under the web root and achieve code execution as root.
FINS (Factory Interface Network Service) is a message communication protocol, which is designed to be used in closed FA (Factory Automation) networks, and is used in FA networks composed of OMRON products. Multiple OMRON products that implement FINS protocol contain following security issues -- (1)Plaintext communication, and (2)No authentication required. When FINS messages are intercepted, the contents may be retrieved. When arbitrary FINS messages are injected, any commands may be executed on, or the system information may be retrieved from, the affected device. Affected products and versions are as follows: SYSMAC CS-series CPU Units, all versions, SYSMAC CJ-series CPU Units, all versions, SYSMAC CP-series CPU Units, all versions, SYSMAC NJ-series CPU Units, all versions, SYSMAC NX1P-series CPU Units, all versions, SYSMAC NX102-series CPU Units, all versions, and SYSMAC NX7 Database Connection CPU Units (Ver.1.16 or later)
Vulnerability in the Oracle Web Applications Desktop Integrator product of Oracle E-Business Suite (component: Upload). Supported versions that are affected are 12.2.3-12.2.11. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Web Applications Desktop Integrator. Successful attacks of this vulnerability can result in takeover of Oracle Web Applications Desktop Integrator. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
BSS Continuity CMS 4.2.22640.0 has an Authentication Bypass vulnerability
CouchDB version 3.0.0 shipped with a new configuration setting that governs access control to the entire database server called `require_valid_user_except_for_up`. It was meant as an extension to the long standing setting `require_valid_user`, which in turn requires that any and all requests to CouchDB will have to be made with valid credentials, effectively forbidding any anonymous requests. The new `require_valid_user_except_for_up` is an off-by-default setting that was meant to allow requiring valid credentials for all endpoints except for the `/_up` endpoint. However, the implementation of this made an error that lead to not enforcing credentials on any endpoint, when enabled. CouchDB versions 3.0.1[1] and 3.1.0[2] fix this issue.
A vulnerability in the web-based management interface of ClearPass Policy Manager could allow an unauthenticated remote attacker to create arbitrary users on the platform. A successful exploit allows an attacker to achieve total cluster compromise.
D-Link - CWE-288:Authentication Bypass Using an Alternate Path or Channel
HGiga PowerStation has a vulnerability of Information Leakage. An unauthenticated remote attacker can exploit this vulnerability to obtain the administrator's credential. This credential can then be used to login PowerStation or Secure Shell to achieve remote code execution.
The system application (com.transsion.kolun.aiservice) component does not perform an authentication check, which allows attackers to perform malicious exploitations and affect system services.
The Flexi Classic and Flexi Soft Gateways SICK UE410-EN3 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK UE410-EN1 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK UE410-EN3S04 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK UE410-EN4 FLEXI ETHERNET GATEW. with serial number <=2311xxxx all Firmware versions, SICK FX0-GENT00000 FLEXISOFT EIP GATEW. with serial number <=2311xxxx with Firmware <=V2.11.0, SICK FX0-GMOD00000 FLEXISOFT MOD GATEW. with serial number <=2311xxxx with Firmware <=V2.11.0, SICK FX0-GPNT00000 FLEXISOFT PNET GATEW. with serial number <=2311xxxx with Firmware <=V2.12.0, SICK FX0-GENT00030 FLEXISOFT EIP GATEW.V2 with serial number <=2311xxxx all Firmware versions, SICK FX0-GPNT00030 FLEXISOFT PNET GATEW.V2 with serial number <=2311xxxx all Firmware versions and SICK FX0-GMOD00010 FLEXISOFT MOD GW with serial number <=2311xxxx with Firmware <=V2.11.0 all have Telnet enabled by factory default. No password is set in the default configuration.
An issue regarding missing authentication for certain utilities exists in CyberPower PowerPanel Enterprise prior to v2.8.3. An unauthenticated remote attacker can access the PDNU REST APIs, which may result in compromise of the application.
Missing Authentication for Critical Function in SICK FX0-GPNT v3 Firmware Version V3.04 and V3.05 allows an unprivileged remote attacker to achieve arbitrary remote code execution via maliciously crafted RK512 commands to the listener on TCP port 9000.
SICK Package Analytics software up to and including version V04.0.0 are vulnerable to an authentication bypass by directly interfacing with the REST API. An attacker can send unauthorized requests, bypass current authentication controls presented by the application and could potentially write files without authentication.
Missing Authentication for Critical Function in SICK FX0-GENT v3 Firmware Version V3.04 and V3.05 allows an unprivileged remote attacker to achieve arbitrary remote code execution via maliciously crafted RK512 commands to the listener on TCP port 9000.
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). The supported version that is affected is 12.2.1.3.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in takeover of Oracle WebLogic Server. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 12.2.1.4.0 and 14.1.1.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in takeover of Oracle WebLogic Server. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to create users on the PLC. This could allow an attacker to create and use an account with elevated privileges and take control of the device.
A vulnerability, which was classified as critical, was found in MAXTECH MAX-G866ac 0.4.1_TBRO_20160314. This affects an unknown part of the component Remote Management. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227001 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Multiple vulnerabilities in Cisco Nexus Dashboard could allow an unauthenticated, remote attacker to execute arbitrary commands, read or upload container image files, or perform a cross-site request forgery attack. For more information about these vulnerabilities, see the Details section of this advisory.
A vulnerability in the web-based management interface of Cisco SPA112 2-Port Phone Adapters could allow an unauthenticated, remote attacker to execute arbitrary code on an affected device. This vulnerability is due to a missing authentication process within the firmware upgrade function. An attacker could exploit this vulnerability by upgrading an affected device to a crafted version of firmware. A successful exploit could allow the attacker to execute arbitrary code on the affected device with full privileges. Cisco has not released firmware updates to address this vulnerability.
A vulnerability classified as critical was found in SourceCodester Online Pizza Ordering System 1.0. Affected by this vulnerability is the function delete_category of the file ajax.php of the component POST Parameter Handler. The manipulation leads to missing authentication. The attack can be launched remotely. The associated identifier of this vulnerability is VDB-221455.
An unauthenticated remote attacker who is aware of a MQTT topic name can send and receive messages, including GET/SET configuration commands, reboot commands and firmware updates.
SnapCenter versions 4.7 prior to 4.7P2 and 4.8 prior to 4.8P1 are susceptible to a vulnerability which could allow a remote unauthenticated attacker to gain access as an admin user.
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code execution in the context of an administrator.
The UI in DevSpace 4.13.0 allows web sites to execute actions on pods (on behalf of a victim) because of a lack of authentication for the WebSocket protocol. This leads to remote code execution.
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior allows the execution of commands without credentials. As Telnet and file transfer protocol (FTP) are the only protocols available for device management, an unauthorized user could access the system and modify the device configuration, which could result in the unauthorized user executing unrestricted malicious commands.
Grandstream GRP261x VoIP phone running firmware version 1.0.3.6 (Base) allow Authentication Bypass in its administrative web interface.
It is possible to enumerate access card credentials via an unauthenticated network connection to the server in versions of Command Centre v8.20 prior to v8.20.1166(MR3), versions of 8.10 prior to v8.10.1211(MR5), versions of 8.00 prior to v8.00.1228(MR6), all versions of 7.90 and earlier. These credentials can then be used to encode low security cards to be used by the system where insecure card technologies are supported.
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
Lack of access control in Nakivo Backup & Replication Transporter version 9.4.0.r43656 allows remote users to access unencrypted backup repositories and the Nakivo Controller configuration via a network accessible transporter service. It is also possible to create or delete backup repositories.
Affected versions of Smartstore have a missing WebApi Authentication attribute. This vulnerability affects Smartstore shops in version 4.0.0 & 4.0.1 which have installed and activated the Web API plugin. Users of Smartstore 4.0.0 and 4.0.1 must merge their repository with 4.0.x or overwrite the file SmartStore.Web.Framework in the */bin* directory of the deployed shop with this file. As a workaround without updating uninstall the Web API plugin to close this vulnerability.
Password recovery vulnerability in SICK SIM2000ST Partnumber 2086502 with firmware version <1.13.4 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.13.4 as soon as possible (available in SICK Support Portal).
Webhood is a self-hosted URL scanner used analyzing phishing and malicious sites. Webhood's backend container images in versions 0.9.0 and earlier are subject to Missing Authentication for Critical Function vulnerability. This vulnerability allows an unauthenticated attacker to send a HTTP request to the database (Pocketbase) admin API to create an admin account. The Pocketbase admin API does not check for authentication/authorization when creating an admin account when no admin accounts have been added. In its default deployment, Webhood does not create a database admin account. Therefore, unless users have manually created an admin account in the database, an admin account will not exist in the deployment and the deployment is vulnerable. Versions starting from 0.9.1 are patched. The patch creates a randomly generated admin account if admin accounts have not already been created i.e. the vulnerability is exploitable in the deployment. As a workaround, users can disable access to URL path starting with `/api/admins` entirely. With this workaround, the vulnerability is not exploitable via network.
An issue was discovered in Veritas NetBackup Flex Scale through 3.0 and Access Appliance through 8.0.100. Unauthenticated remote command execution can occur via the management portal.
Even if the authentication fails for local service authentication, the requested command could still execute regardless of authentication status.
KubeView through 0.1.31 allows attackers to obtain control of a Kubernetes cluster because api/scrape/kube-system does not require authentication, and retrieves certificate files that can be used for authentication as kube-admin. NOTE: the vendor's position is that KubeView was a "fun side project and a learning exercise," and not "very secure."
A potential security vulnerability has been identified in HPE Application Performance Management (BSM) Platform versions 9.26, 9.30, 9.40. The vulnerability could be remotely exploited to allow code execution.
Garden is an automation platform for Kubernetes development and testing. In versions prior to 0.12.39 multiple endpoints did not require authentication. In some operating modes this allows for an attacker to gain access to the application erroneously. The configuration is leaked through the /api endpoint on the local server that is responsible for serving the Garden dashboard. At the moment, this server is accessible to 0.0.0.0 which makes it accessible to anyone on the same network (or anyone on the internet if they are on a public, static IP). This may lead to the ability to compromise credentials, secrets or environment variables. Users are advised to upgrade to version 0.12.39 as soon as possible. Users unable to upgrade should use a firewall blocking access to port 9777 from all untrusted network machines.
In the default configuration of Apache SOAP, an RPCRouterServlet is available without authentication. This gives an attacker the possibility to invoke methods on the classpath that meet certain criteria. Depending on what classes are available on the classpath this might even lead to arbitrary remote code execution. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
Telepad allows remote unauthenticated users to send instructions to the server to execute arbitrary code without any previous authorization or authentication. CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise.
PC Keyboard allows remote unauthenticated users to send instructions to the server to execute arbitrary code without any previous authorization or authentication. CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H