Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2021-22779

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-14 Jul, 2021 | 14:26
Updated At-29 May, 2026 | 13:50
Rejected At-
Credits

Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:14 Jul, 2021 | 14:26
Updated At:29 May, 2026 | 13:50
Rejected At:
▼CVE Numbering Authority (CNA)

Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.

Affected Products
Vendor
n/a
Product
EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)
Versions
Affected
  • EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)
Problem Types
TypeCWE IDDescription
CWECWE-290CWE-290: Authentication Bypass by Spoofing
Type: CWE
CWE ID: CWE-290
Description: CWE-290: Authentication Bypass by Spoofing
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01
x_refsource_MISC
Hyperlink: http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01
x_refsource_MISC
x_transferred
Hyperlink: http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01
Resource:
x_refsource_MISC
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
3.16.5MEDIUM
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N
Version: 3.1
Base score: 6.5
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:14 Jul, 2021 | 15:15
Updated At:29 May, 2026 | 15:16

Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.19.1CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
Secondary3.16.5MEDIUM
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N
Primary2.06.4MEDIUM
AV:N/AC:L/Au:N/C:P/I:P/A:N
Type: Primary
Version: 3.1
Base score: 9.1
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
Type: Secondary
Version: 3.1
Base score: 6.5
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N
Type: Primary
Version: 2.0
Base score: 6.4
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:N/C:P/I:P/A:N
CPE Matches

Schneider Electric SE
schneider-electric
>>ecostruxure_control_expert>>Versions before 15.0(exclusive)
cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>ecostruxure_control_expert>>15.0
cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>ecostruxure_control_expert>>15.0
cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:sp1:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>ecostruxure_process_expert>>*
cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>remoteconnect>>*
cpe:2.3:a:schneider-electric:remoteconnect:*:*:*:*:*:*:scadapack_x70:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep581020_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmep581020_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep581020>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmep581020:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep581020h_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmep581020h_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep581020h>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmep581020h:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep582020_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmep582020_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep582020>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmep582020:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep582020h_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmep582020h_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep582020h>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmep582020h:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep582040_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmep582040_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep582040>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmep582040:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep582040h_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmep582040h_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep582040h>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmep582040h:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep582040s_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmep582040s_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep582040s>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmep582040s:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep583020_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmep583020_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep583020>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmep583020:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep583040_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmep583040_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep583040>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmep583040:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep584020_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmep584020_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep584020>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmep584020:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep584040_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmep584040_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep584040>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmep584040:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep584040s_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmep584040s_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep584040s>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmep584040s:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep585040_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmep585040_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep585040>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmep585040:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep585040c_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmep585040c_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep585040c>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmep585040c:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep586040_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmep586040_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep586040>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmep586040:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep586040c_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmep586040c_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmep586040c>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmep586040c:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmeh582040_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmeh582040>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmeh582040:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmeh582040c_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040c_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmeh582040c>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmeh582040c:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmeh582040s_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040s_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmeh582040s>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmeh582040s:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmeh584040_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmeh584040>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmeh584040:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmeh584040c_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040c_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmeh584040c>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmeh584040c:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmeh584040s_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040s_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmeh584040s>>-
cpe:2.3:h:schneider-electric:modicon_m580_bmeh584040s:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m580_bmeh586040_firmware>>*
cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040_firmware:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-290Secondarycybersecurity@se.com
CWE ID: CWE-290
Type: Secondary
Source: cybersecurity@se.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01cybersecurity@se.com
Vendor Advisory
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01af854a3a-2127-422b-91ae-364da2661108
Vendor Advisory
Hyperlink: http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01
Source: cybersecurity@se.com
Resource:
Vendor Advisory
Hyperlink: http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

57Records found

CVE-2023-51323
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.11% / 28.27%
||
7 Day CHG~0.00%
Published-20 Feb, 2025 | 00:00
Updated-04 Nov, 2025 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A lack of rate limiting in the 'Forgot Password' feature of PHPJabbers Shared Asset Booking System v1.0 allows attackers to send an excessive amount of email for a legitimate user, leading to a possible Denial of Service (DoS) via a large amount of generated e-mail messages.

Action-Not Available
Vendor-n/aPHPJabbers Ltd.
Product-shared_asset_booking_systemn/a
CWE ID-CWE-290
Authentication Bypass by Spoofing
CVE-2024-3050
Matching Score-4
Assigner-WPScan
ShareView Details
Matching Score-4
Assigner-WPScan
CVSS Score-9.1||CRITICAL
EPSS-0.76% / 73.71%
||
7 Day CHG~0.00%
Published-29 May, 2024 | 06:00
Updated-21 May, 2025 | 19:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Site Reviews < 7.0.0 - IP Spoofing

The Site Reviews WordPress plugin before 7.0.0 retrieves client IP addresses from potentially untrusted headers, allowing an attacker to manipulate its value. This may be used to bypass IP-based blocking

Action-Not Available
Vendor-geminilabsUnknownpaul_ryley
Product-site_reviewsSite Reviewssite_reviews
CWE ID-CWE-290
Authentication Bypass by Spoofing
CVE-2022-23131
Matching Score-4
Assigner-Zabbix
ShareView Details
Matching Score-4
Assigner-Zabbix
CVSS Score-9.1||CRITICAL
EPSS-94.05% / 99.90%
||
7 Day CHG~0.00%
Published-13 Jan, 2022 | 15:50
Updated-30 Oct, 2025 | 20:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-03-08||Apply updates per vendor instructions.
Unsafe client-side session storage leading to authentication bypass/instance takeover via Zabbix Frontend with configured SAML

In the case of instances where the SAML SSO authentication is enabled (non-default), session data can be modified by a malicious actor, because a user login stored in the session was not verified. Malicious unauthenticated actor may exploit this issue to escalate privileges and gain admin access to Zabbix Frontend. To perform the attack, SAML authentication is required to be enabled and the actor has to know the username of Zabbix user (or use the guest account, which is disabled by default).

Action-Not Available
Vendor-ZABBIX
Product-zabbixFrontendFrontend
CWE ID-CWE-290
Authentication Bypass by Spoofing
CVE-2017-14487
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.1||CRITICAL
EPSS-0.25% / 48.41%
||
7 Day CHG~0.00%
Published-01 Dec, 2017 | 17:00
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The OhMiBod Remote app for Android and iOS allows remote attackers to impersonate users by sniffing network traffic for search responses from the OhMiBod API server and then editing the username, user_id, and token fields in data/data/com.ohmibod.remote2/shared_prefs/OMB.xml.

Action-Not Available
Vendor-ohmibodn/a
Product-ohmibod_remoten/a
CWE ID-CWE-290
Authentication Bypass by Spoofing
CVE-2023-51326
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.11% / 28.27%
||
7 Day CHG~0.00%
Published-20 Feb, 2025 | 00:00
Updated-04 Nov, 2025 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A lack of rate limiting in the 'Forgot Password' feature of PHPJabbers Cleaning Business Software v1.0 allows attackers to send an excessive amount of email for a legitimate user, leading to a possible Denial of Service (DoS) via a large amount of generated e-mail messages.

Action-Not Available
Vendor-n/aPHPJabbers Ltd.
Product-cleaning_business_softwaren/a
CWE ID-CWE-290
Authentication Bypass by Spoofing
CVE-2023-48396
Matching Score-4
Assigner-Apache Software Foundation
ShareView Details
Matching Score-4
Assigner-Apache Software Foundation
CVSS Score-9.1||CRITICAL
EPSS-0.33% / 56.10%
||
7 Day CHG~0.00%
Published-30 Jul, 2024 | 08:15
Updated-10 Jul, 2025 | 18:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Apache SeaTunnel Web: Authentication bypass

Web Authentication vulnerability in Apache SeaTunnel. Since the jwt key is hardcoded in the application, an attacker can forge any token to log in any user. Attacker can get secret key in /seatunnel-server/seatunnel-app/src/main/resources/application.yml and then create a token. This issue affects Apache SeaTunnel: 1.0.0. Users are recommended to upgrade to version 1.0.1, which fixes the issue.

Action-Not Available
Vendor-The Apache Software Foundation
Product-seatunnelApache SeaTunnel Webseatunnel
CWE ID-CWE-290
Authentication Bypass by Spoofing
CVE-2024-27349
Matching Score-4
Assigner-Apache Software Foundation
ShareView Details
Matching Score-4
Assigner-Apache Software Foundation
CVSS Score-9.1||CRITICAL
EPSS-0.44% / 63.54%
||
7 Day CHG~0.00%
Published-22 Apr, 2024 | 14:08
Updated-21 Aug, 2025 | 03:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Apache HugeGraph-Server: Bypass whitelist in Auth mode

Authentication Bypass by Spoofing vulnerability in Apache HugeGraph-Server.This issue affects Apache HugeGraph-Server: from 1.0.0 before 1.3.0. Users are recommended to upgrade to version 1.3.0, which fixes the issue.

Action-Not Available
Vendor-The Apache Software Foundation
Product-hugegraphApache HugeGraph-Serverhugegraph-server
CWE ID-CWE-290
Authentication Bypass by Spoofing
  • Previous
  • 1
  • 2
  • Next
Details not found