AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update. Code is executed under the program runtime privileges, which could lead to the compromise of the machine.
InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. A remote attacker could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability during tag, alarm, or event related actions such as read and write, with potential for code to be executed. If InduSoft Web Studio remote communication security was not enabled, or a password was left blank, a remote user could send a carefully crafted packet to invoke an arbitrary process, with potential for code to be executed. The code would be executed under the privileges of the InduSoft Web Studio or InTouch Edge HMI runtime and could lead to a compromise of the InduSoft Web Studio or InTouch Edge HMI server machine.
Heap-based buffer overflow in SuiteLink server while processing commands 0x05/0x06
The listed versions of AVEVA Plant SCADA and AVEVA Telemetry Server are vulnerable to an improper authorization exploit which could allow an unauthenticated user to remotely read data, cause denial of service, and tamper with alarm states.
InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. This vulnerability could allow an unauthenticated user to remotely execute code with the same privileges as that of the InduSoft Web Studio or InTouch Edge HMI (formerly InTouch Machine Edition) runtime.
Parameter psClass in ednareporting.asmx is vulnerable to unauthenticated SQL injection attacks. Specially crafted SOAP web requests can cause SQL injections resulting in data compromise. An attacker can send unauthenticated HTTP requests to trigger this vulnerability.
SQL injection vulnerability exists in the CHaD.asmx web service functionality of eDNA Enterprise Data Historian 3.0.1.2/7.5.4989.33053. Specially crafted SOAP web requests can cause SQL injections resulting in data compromise. Parameter ClassName in CHaD.asmx is vulnerable to unauthenticated SQL injection attacks.
AVEVA InTouch 2014 R2 SP1 and prior, InTouch 2017, InTouch 2017 Update 1, and InTouch 2017 Update 2 allow an unauthenticated user to send a specially crafted packet that could overflow the buffer on a locale not using a dot floating point separator. Exploitation could allow remote code execution under the privileges of the InTouch View process.
AVEVA InduSoft Web Studio v8.1 and v8.1SP1, and InTouch Machine Edition v2017 8.1 and v2017 8.1 SP1 a remote user could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability during tag, alarm, or event related actions such as read and write, with potential for code to be executed.
An Information Exposure issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. Credentials may be exposed to external systems via specific URL parameters, as arbitrary destination addresses may be specified.
An issue was discovered in ExecuteCommand() in AVEVA Edge (formerly InduSoft Web Studio) versions R2020 and prior that allows unauthenticated arbitrary commands to be executed.
An SQL injection vulnerability exists in the CHaD.asmx web service functionality of eDNA Enterprise Data Historian 3.0.1.2/7.5.4989.33053. Specially crafted SOAP web requests can cause SQL injections resulting in data compromise. Parameter InstancePath in CHaD.asmx is vulnerable to unauthenticated SQL injection attacks.
Parameter AttFilterValue in ednareporting.asmx is vulnerable to unauthenticated SQL injection attacks. Specially crafted SOAP web requests can cause SQL injections resulting in data compromise. An attacker can send unauthenticated HTTP requests to trigger this vulnerability.
AVEVA Wonderware System Platform 2017 Update 2 and prior uses an ArchestrA network user account for authentication of system processes and inter-node communications. A user with low privileges could make use of an API to obtain the credentials for this account.
An SQL injection vulnerability exists in the CHaD.asmx web service functionality of eDNA Enterprise Data Historian 3.0.1.2/7.5.4989.33053. Specially crafted SOAP web requests can cause SQL injections resulting in data compromise. Parameter InstanceName in CHaD.asmx is vulnerable to unauthenticated SQL injection attacks.
Under certain circumstances, SAP HANA Extended Application Services, advanced model (XS advanced) does not perform authentication checks properly for XS advanced platform and business users. Fixed in 1.0.97 to 1.0.99 (running on SAP HANA 1 or SAP HANA 2 SPS0 (second S stands for stack)).
Contec Smart Home 4.15 devices do not require authentication for new_user.php, edit_user.php, delete_user.php, and user.php, as demonstrated by changing the admin password and then obtaining control over doors.
By default, the Packet Power Monitoring and Control Web Interface do not enforce authentication mechanisms. This vulnerability could allow unauthorized users to access and manipulate monitoring and control functions.
The default configuration in Apache Cassandra 3.8 through 3.11.1 binds an unauthenticated JMX/RMI interface to all network interfaces, which allows remote attackers to execute arbitrary Java code via an RMI request. This issue is a regression of CVE-2015-0225. The regression was introduced in https://issues.apache.org/jira/browse/CASSANDRA-12109. The fix for the regression is implemented in https://issues.apache.org/jira/browse/CASSANDRA-14173. This fix is contained in the 3.11.2 release of Apache Cassandra.
SAP Cloud Connector, before version 2.11.3, does not perform any authentication checks for functionalities that require user identity.
WebITR developed by Uniong has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to log into the system as arbitrary users by exploiting a specific functionality.
Authentication Bypass Using an Alternate Path or Channel vulnerability in Drupal Authenticator Login allows Authentication Bypass.This issue affects Authenticator Login: from 0.0.0 before 2.1.4.
ManageEngine Log360 Builds < 5235 are affected by an improper access control vulnerability allowing database configuration overwrite. An unauthenticated remote attacker can send a specially crafted message to Log360 to change its backend database to an attacker-controlled database and to force Log360 to restart. An attacker can leverage this vulnerability to achieve remote code execution by replacing files executed by Log360 on startup.
Properly formatted POST requests to multiple resources on the HTTP and HTTPS web servers of the Digi PortServer TS 16 Rack device do not require authentication or authentication tokens. This vulnerability could allow an attacker to enable the SNMP service and manipulate the community strings to achieve further control in.
Missing Authentication for critical function vulnerability in HYPR Server allows Authentication Bypass when using Legacy APIs.This issue affects HYPR Server: before 8.0 (with enabled Legacy APIs)
A vulnerability in the web-based management interface of Cisco SPA112 2-Port Phone Adapters could allow an unauthenticated, remote attacker to execute arbitrary code on an affected device. This vulnerability is due to a missing authentication process within the firmware upgrade function. An attacker could exploit this vulnerability by upgrading an affected device to a crafted version of firmware. A successful exploit could allow the attacker to execute arbitrary code on the affected device with full privileges. Cisco has not released firmware updates to address this vulnerability.
A vulnerability was found in harry0703 MoneyPrinterTurbo up to 1.2.6 and classified as critical. Affected by this issue is the function verify_token of the file app/controllers/base.py of the component API Endpoint. The manipulation leads to missing authentication. The attack may be launched remotely.
The Custom MCPs feature is designed to execute OS commands, for instance, using tools like `npx` to spin up local MCP Servers. However, Flowise's inherent authentication and authorization model is minimal and lacks role-based access controls (RBAC). Furthermore, in Flowise versions before 3.0.1 the default installation operates without authentication unless explicitly configured. This combination allows unauthenticated network attackers to execute unsandboxed OS commands.
An issue was discovered in Zoho ManageEngine Desktop Central 10.0.124 and 10.0.184: missing authentication/authorization for a database query mechanism.
The variable import endpoint was not protected by authentication in Airflow >=2.0.0, <2.1.3. This allowed unauthenticated users to hit that endpoint to add/modify Airflow variables used in DAGs, potentially resulting in a denial of service, information disclosure or remote code execution. This issue affects Apache Airflow >=2.0.0, <2.1.3.
The server permits communication without any authentication procedure, allowing the attacker to initiate a session with the server without providing any form of authentication.
A vulnerability was found in SimStudioAI sim up to 37786d371e17d35e0764e1b5cd519d873d90d97b. It has been declared as critical. Affected by this vulnerability is the function POST of the file apps/sim/app/api/files/upload/route.ts of the component Session Handler. The manipulation of the argument Request leads to missing authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users.
Insufficient input validation within GitLab Language Server 7.6.0 and later before 7.30.0 allows arbitrary GraphQL query execution
eQ-3 AG HomeMatic CCU2 2.29.22 devices have an open XML-RPC port without authentication. This can be exploited by sending arbitrary XML-RPC requests to control the attached BidCos devices.
An issue was discovered in Zoho ManageEngine Desktop Central 10.0.124 and 10.0.184: insufficient enforcement of database query type restrictions.
A missing authentication for critical function in Fortinet FortiManager version 7.4.0 through 7.4.2, 7.2.0 through 7.2.4, 7.0.0 through 7.0.11, 6.4.0 through 6.4.14, FortiPAM version 1.2.0, 1.1.0 through 1.1.2, 1.0.0 through 1.0.3, FortiProxy version 7.4.0 through 7.4.2, 7.2.0 through 7.2.9, 7.0.0 through 7.0.17, 2.0.0 through 2.0.14, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7, FortiSwitchManager version 7.2.0 through 7.2.3, 7.0.0 through 7.0.3, FortiPortal version 6.0.0 through 6.0.14, FortiOS version 7.4.0 through 7.4.3, 7.2.0 through 7.2.7, 7.0.0 through 7.0.14, 6.4.0 through 6.4.15, 6.2.0 through 6.2.16, 6.0.0 through 6.0.18 allows attacker to execute unauthorized code or commands via specially crafted packets.
SnapCenter versions 4.7 prior to 4.7P2 and 4.8 prior to 4.8P1 are susceptible to a vulnerability which could allow a remote unauthenticated attacker to gain access as an admin user.
An unauthenticated remote attacker who is aware of a MQTT topic name can send and receive messages, including GET/SET configuration commands, reboot commands and firmware updates.
A vulnerability classified as critical was found in SourceCodester Online Pizza Ordering System 1.0. Affected by this vulnerability is the function delete_category of the file ajax.php of the component POST Parameter Handler. The manipulation leads to missing authentication. The attack can be launched remotely. The associated identifier of this vulnerability is VDB-221455.
Mattermost versions 8.1.x before 8.1.10, 9.2.x before 9.2.6, 9.3.x before 9.3.2, and 9.4.x before 9.4.3 fail to correctly verify account ownership when switching from email to SAML authentication, allowing an authenticated attacker to take over other user accounts via a crafted switch request under specific conditions.
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior allows the execution of commands without credentials. As Telnet and file transfer protocol (FTP) are the only protocols available for device management, an unauthorized user could access the system and modify the device configuration, which could result in the unauthorized user executing unrestricted malicious commands.
In JetBrains TeamCity before 2023.11.3 authentication bypass leading to RCE was possible
A vulnerability was found in rowboatlabs rowboat up to 8096eaf63b5a0732edd8f812bee05b78e214ee97. It has been rated as critical. Affected by this issue is the function PUT of the file apps/rowboat/app/api/uploads/[fileId]/route.ts of the component Session Handler. The manipulation of the argument params leads to missing authentication. The attack may be launched remotely. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. It is expected that this issue will be fixed in the near future.
A vulnerability classified as critical has been found in code-projects Laundry System 1.0. This affects an unknown part of the file /data/. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
admin.php in Frax.dk Php Recommend 1.3 and earlier does not require authentication when the user password is changed, which allows remote attackers to gain administrative privileges via modified form_admin_user and form_admin_pass parameters.
An arbitrary code execution vulnerability exists in Arris SURFboard SGB6950AC2 devices. An unauthenticated attacker can exploit this vulnerability to achieve code execution as root.
Password recovery vulnerability in SICK SIM2000ST Partnumber 2086502 with firmware version <1.13.4 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.13.4 as soon as possible (available in SICK Support Portal).
A lack of authentication vulnerability exists in the HTTP API functionality of GoCast 1.1.3. A specially crafted HTTP request can lead to arbitrary command execution. An attacker can make an unauthenticated HTTP request to trigger this vulnerability.
Nextcloud Global Site Selector is a tool which allows you to run multiple small Nextcloud instances and redirect users to the right server. A problem in the password verification method allows an attacker to authenticate as another user. It is recommended that the Nextcloud Global Site Selector is upgraded to version 1.4.1, 2.1.2, 2.3.4 or 2.4.5. There are no known workarounds for this issue.