Session fixation vulnerability in chameleon cms 3.0 and earlier allows remote attackers to hijack web sessions by setting the PHPSESSID parameter.
In the DES implementation, the affected product versions use a default key for encryption. Successful exploitation allows an attacker to obtain sensitive information and gain access to the network elements that are managed by the affected products versions. This issue affects * FOXMAN-UN product: FOXMAN-UN R16A, FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C; * UNEM product: UNEM R16A, UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C. List of CPEs: * cpe:2.3:a:hitachienergy:foxman-un:R16A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R16A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*
An issue was discovered in the ALU unit of the OR1200 (aka OpenRISC 1200) processor 2011-09-10 through 2015-11-11. The overflow flag is not being updated correctly for the subtract instruction, which results in an incorrect value in the overflow flag. Any software that relies on this flag may experience corruption in execution.
Dataprobe iBootBar (with 2007-09-20 and possibly later released firmware) allows remote attackers to bypass authentication, and conduct power-cycle attacks on connected devices, via a DCRABBIT cookie.
Improper Authentication vulnerability in Microchip TimeProvider 4100 (login modules) allows Session Hijacking.This issue affects TimeProvider 4100: from 1.0 before 2.4.7.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 anyone can change the administrator and moderator passwords via the iso.3.6.1.4.1.3212.100.3.2.8.1 and iso.3.6.1.4.1.3212.100.3.2.8.2 OIDs. A remote, unauthenticated attacker can use this vulnerability to change the admin or moderator user's password and gain access to restricted areas on the HTTP interface.
Improper Authentication vulnerability in upKeeper Solutions product upKeeper Manager allows Authentication Bypass.This issue affects upKeeper Manager: through 5.1.9.
Apache Shiro before 1.8.0, when using Apache Shiro with Spring Boot, a specially crafted HTTP request may cause an authentication bypass. Users should update to Apache Shiro 1.8.0.
An issue was discovered in LemonLDAP::NG (aka lemonldap-ng) 2.0.13. When using the RESTServer plug-in to operate a REST password validation service (for another LemonLDAP::NG instance, for example) and using the Kerberos authentication method combined with another method with the Combination authentication plug-in, any password will be recognized as valid for an existing user.
A vulnerability has been found in Kehua Charging Pile Cloud Platform 1.0 and classified as critical. This vulnerability affects unknown code of the file /home. The manipulation leads to improper authentication. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been identified in SENTRON 7KM PAC3200 (All versions). Affected devices only provide a 4-digit PIN to protect from administrative access via Modbus TCP interface. Attackers with access to the Modbus TCP interface could easily bypass this protection by brute-force attacks or by sniffing the Modbus clear text communication.
Session fixation vulnerability in onelook courts on-line allows remote attackers to hijack web sessions by setting a PHPSESSID cookie.
An issue in Ocuco Innovation - INNOVASERVICEINTF.EXE v2.10.24.17 allows attackers to bypass authentication and escalate privileges to Administrator via a crafted TCP packet.
The RegistrationMagic WordPress plugin made it possible for unauthenticated users to log in as any site user, including administrators, if they knew a valid username on the site due to missing identity validation in the social login function social_login_using_email() of the plugin. This affects versions equal to, and less than, 5.0.1.7.
A vulnerability classified as critical has been found in Metasoft 美特软件 MetaCRM up to 6.4.2. This affects an unknown part of the file /debug.jsp. The manipulation leads to improper authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
InfluxDB before 1.7.6 has an authentication bypass vulnerability in the authenticate function in services/httpd/handler.go because a JWT token may have an empty SharedSecret (aka shared secret).
Session fixation vulnerability in onelook onebyone CMS allows remote attackers to hijack web sessions by setting a PHPSESSID cookie.
handleIncomingPacket in conn.go in Pion DTLS before 1.5.2 lacks a check for application data with epoch 0, which allows remote attackers to inject arbitrary unencrypted data after handshake completion.
A vulnerability, which was classified as critical, was found in LB-LINK BL-AC1900, BL-AC2100_AZ3, BL-AC3600, BL-AX1800, BL-AX5400P and BL-WR9000 up to 20250702. Affected is the function reboot/restore of the file /cgi-bin/lighttpd.cgi of the component Web Interface. The manipulation leads to improper authentication. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
In some cases, Service Pack 4 for Windows NT 4.0 can allow access to network shares using a blank password, through a problem with a null NT hash value.
An issue was discovered in WildFly 10.1.2.Final. In the case of a default installation without a security realm reference, an attacker can successfully access the server without authentication. NOTE: the Security Realms documentation in the product's Admin Guide indicates that "without a security realm reference" implies "effectively unsecured." The vendor explicitly supports these unsecured configurations because they have valid use cases during development
On Aspire-derived NEC PBXes, including all versions of SV8100 devices, a set of documented, static login credentials may be used to access the DIM interface.
CA Automic Sysload 5.6.0 through 6.1.2 contains a vulnerability, related to a lack of authentication on the File Server port, that potentially allows remote attackers to execute arbitrary commands.
MFScripts YetiShare v3.5.2 through v4.5.4 might allow an attacker to reset a password by using a leaked hash (the hash never expires until used).
In MIELE XGW 3000 ZigBee Gateway before 2.4.0, the Password Change Function does not require knowledge of the old password. This can be exploited in conjunction with CVE-2019-20480.
libc in OpenBSD 6.6 allows authentication bypass via the -schallenge username, as demonstrated by smtpd, ldapd, or radiusd. This is related to gen/auth_subr.c and gen/authenticate.c in libc (and login/login.c and xenocara/app/xenodm/greeter/verify.c).
An issue was discovered in the ALU unit of the OR1200 (aka OpenRISC 1200) processor 2011-09-10 through 2015-11-11. The overflow flag is not being updated for the msb and mac instructions, which results in an incorrect value in the overflow flag. Any software that relies on this flag may experience corruption in execution.
On certain TOTOLINK Realtek SDK based routers, the CAPTCHA text can be retrieved via an {"topicurl":"setting/getSanvas"} POST to the boafrm/formLogin URI, leading to a CAPTCHA bypass. (Also, the CAPTCHA text is not needed once the attacker has determined valid credentials. The attacker can perform router actions via HTTP requests with Basic Authentication.) This affects A3002RU through 2.0.0, A702R through 2.1.3, N301RT through 2.1.6, N302R through 3.4.0, N300RT through 3.4.0, N200RE through 4.0.0, N150RT through 3.4.0, and N100RE through 3.4.0.
The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. The affected product does not require adequate authentication, which may allow an attacker to read sensitive information or execute arbitrary code. This is a different issue than CVE-2019-16879 and CVE-2019-20045.
A vulnerability was found in rowboatlabs rowboat up to 8096eaf63b5a0732edd8f812bee05b78e214ee97. It has been rated as critical. Affected by this issue is the function PUT of the file apps/rowboat/app/api/uploads/[fileId]/route.ts of the component Session Handler. The manipulation of the argument params leads to missing authentication. The attack may be launched remotely. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. It is expected that this issue will be fixed in the near future.
A vulnerability was found in SimStudioAI sim up to 37786d371e17d35e0764e1b5cd519d873d90d97b. It has been declared as critical. Affected by this vulnerability is the function POST of the file apps/sim/app/api/files/upload/route.ts of the component Session Handler. The manipulation of the argument Request leads to missing authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
An issue was discovered in WildFly 10.1.2.Final. It is possible for an attacker to access the administration panel on TCP port 9990 without any authentication using "anonymous" access that is automatically created. Once logged in, a misconfiguration present by default (auto-deployment) permits an anonymous user to deploy a malicious .war file, leading to remote code execution. NOTE: the vendor indicates that anonymous access is not available in the default installation; however, it remains optional because there are several use cases for it, including development environments and network architectures that have a proxy server for access control to the WildFly server
An issue was discovered on NETGEAR WNR1000V4 1.1.0.54 devices. The web management interface (setup.cgi) has an authentication bypass and other problems that ultimately allow an attacker to remotely compromise the device from a malicious webpage. The attacker sends an FW_remote.htm&todo=cfg_init request without a cookie, reads the Set-Cookie header in the 401 Unauthorized response, and then repeats the FW_remote.htm&todo=cfg_init request with the specified cookie.
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an authentication bypass vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. A remote attacker with network access to the CCS server could exploit this vulnerability to read the CCS users database, including the passwords of all users in obfuscated cleartext.
Microsoft Dynamics 365 Business Central Elevation of Privilege Vulnerability
XSS Hunter Express before 2021-09-17 does not properly enforce authentication requirements for paths.
HTCondor up to and including stable series 8.8.6 and development series 8.9.4 has Incorrect Access Control. It is possible to use a different authentication method to submit a job than the administrator has specified. If the administrator has configured the READ or WRITE methods to include CLAIMTOBE, then it is possible to impersonate another user to the condor_schedd. (For example to submit or remove jobs)
Symantec Critical System Protection (CSP), versions 8.0, 8.0 HF1 & 8.0 MP1, may be susceptible to an authentication bypass vulnerability, which is a type of issue that can potentially allow a threat actor to circumvent existing authentication controls.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The AdminService is available without authentication on the Application Server. An attacker can use methods exposed via this interface to receive password hashes of other users and to change user passwords. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A Improper Authentication vulnerability in cryptctl of SUSE Linux Enterprise Server for SAP 12-SP5, SUSE Manager Server 4.0 allows attackers with access to the hashed password to use it without having to crack it. This issue affects: SUSE Linux Enterprise Server for SAP 12-SP5 cryptctl versions prior to 2.4. SUSE Manager Server 4.0 cryptctl versions prior to 2.4.
In all versions of ABB Power Generation Information Manager (PGIM) and Plant Connect, the affected product is vulnerable to authentication bypass, which may allow an attacker to remotely bypass authentication and extract credentials from the affected device.
Sangoma FreePBX 115.0.16.26 and below, 14.0.13.11 and below, 13.0.197.13 and below have Incorrect Access Control.
The authenticate function in LDAPUserFolder/LDAPUserFolder.py in zope-ldapuserfolder 2.9-1 does not verify the password for the emergency account, which allows remote attackers to gain privileges.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted objects via RMI. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation.
D-Link DIR845L A1 contains a authentication vulnerability via an AUTHORIZED_GROUP=1 value, as demonstrated by a request for getcfg.php.
Broken Authentication vulnerability in SoftLab Integrate Google Drive.This issue affects Integrate Google Drive: from n/a through 1.3.93.
Broken Authentication vulnerability discovered in OpenText™ iManager 3.2.6.0200. This vulnerability allows an attacker to manipulate certain parameters to bypass authentication.
Session fixation vulnerability in onelook obo Shop allows remote attackers to hijack web sessions by setting a PHPSESSID cookie.
D-Link DIR-601 B1 2.00NA devices are vulnerable to authentication bypass. They do not check for authentication at the server side and rely on client-side validation, which is bypassable. NOTE: this is an end-of-life product.