Cleartext transmission of sensitive information. The following products are affected: Acronis Cyber Protect 15 (Windows) before build 29240
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior have only FTP and Telnet available for device management. Any sensitive information communicated through these protocols, such as credentials, is sent in cleartext. An attacker could obtain sensitive information such as user credentials to gain access to the system.
Cleartext transmission of sensitive information. The following products are affected: Acronis Cyber Protect 15 (Linux, Windows) before build 29240
In Modem EMM, there is a possible information disclosure due to a missing data encryption. This could lead to remote information disclosure with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: MOLY00716585; Issue ID: ALPS05886933.
A vulnerability was found in Intergard SGS 8.7.0 and classified as problematic. Affected by this issue is some unknown functionality of the component Password Change Handler. The manipulation leads to cleartext transmission of sensitive information. The attack may be launched remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. VDB-234446 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
OKI C5510MFP Printer CU H2.15, PU 01.03.01, System F/W 1.01, and Web Page 1.00 sends the configuration of the printer in cleartext, which allows remote attackers to obtain the administrative password by connecting to TCP port 5548 or 7777.
Omron CS series, CJ series, and CP series PLCs through 2022-05-18 use cleartext passwords. They feature a UM Protection setting that allows users or system integrators to configure a password in order to restrict sensitive engineering operations (such as project/logic uploads and downloads). This password is set using the OMRON FINS command Program Area Protect and unset using the command Program Area Protect Clear, both of which are transmitted in cleartext.
The affected product is vulnerable to a cleartext transmission of sensitive information vulnerability, which may allow an attacker to capture packets to craft their own requests.
IBM Cognos Analytics Mobile for Android 1.1.14 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information.
This vulnerability exist in Skyworth Router CM5100, version 4.1.1.24, due to transmission of authentication credentials in plaintext over the network. A remote attacker could exploit this vulnerability by eavesdropping on the victim’s network traffic to extract username and password from the web interface (Password Reset Page) of the vulnerable targeted system.
journalpump is a daemon that takes log messages from journald and pumps them to a given output. A logging vulnerability was found in journalpump which logs out the configuration of a service integration in plaintext to the supplied logging pipeline, including credential information contained in the configuration if any. The problem has been patched in journalpump 2.5.0.
A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00). Affected devices do not encrypt web traffic with clients but communicate in cleartext via HTTP. This could allow an unauthenticated attacker to capture the traffic and interfere with the functionality of the device.
A vulnerability was found in Delta Electronics WPLSoft 2.51. It has been classified as problematic. Affected is an unknown function of the component Modbus Handler. The manipulation leads to cleartext transmission of sensitive information. It is possible to launch the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-241584. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Devolutions Server before 2021.1.18, and LTS before 2020.3.20, allows attackers to intercept private keys via a man-in-the-middle attack against the connections/partial endpoint (which accepts cleartext).
Quassel through 0.13.1, when --require-ssl is enabled, launches without SSL or TLS support if a usable X.509 certificate is not found on the local system.
An issue discovereed in EBYTE E880-IR01-V1.1 allows an attacker to obtain sensitive information via crafted POST request to /cgi-bin/luci.
This vulnerability exist in Skyworth Router CM5100, version 4.1.1.24, due to transmission of authentication credentials in plaintext over the network. A remote attacker could exploit this vulnerability by eavesdropping on the victim’s network traffic to extract username and password from the web interface (Login Page) of the vulnerable targeted system.
IBM PowerSC 1.3, 2.0, and 2.1 MFA does not implement the "HTTP Strict Transport Security" (HSTS) web security policy mechanism. IBM X-Force ID: 276004.
The affected ThroughTek P2P products (SDKs using versions before 3.1.5, any versions with nossl tag, device firmware not using AuthKey for IOTC conneciton, firmware using AVAPI module without enabling DTLS mechanism, and firmware using P2PTunnel or RDT module) do not sufficiently protect data transferred between the local device and ThroughTek servers. This can allow an attacker to access sensitive information, such as camera feeds.
While investigating DIRSTUDIO-1219 it was noticed that configured StartTLS encryption was not applied when any SASL authentication mechanism (DIGEST-MD5, GSSAPI) was used. While investigating DIRSTUDIO-1220 it was noticed that any configured SASL confidentiality layer was not applied. This issue affects Apache Directory Studio version 2.0.0.v20210213-M16 and prior versions.
A Cleartext Transmission of Sensitive Information vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote attacker to obtain sensitive information by snooping on the network traffic. The exposed data includes critical values for a pump's internal configuration.
A vulnerability was found in ISS BlackICE PC Protection. It has been declared as problematic. Affected by this vulnerability is the component Update Handler which allows cleartext transmission of data. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
D-Link DIR-865L Ax 1.20B01 Beta devices have Cleartext Transmission of Sensitive Information.
Cleartext Transmission of Sensitive Information in /northstar/Admin/login.jsp in Northstar Technologies Inc NorthStar Club Management 6.3 allows remote local user to intercept users credentials transmitted in cleartext over HTTP.
Philips Vue PACS versions 12.2.x.x and prior transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors.
LOYTEC LINX-151, LINX-212, LVIS-3ME12-A1, LIOB-586, LIOB-580 V2, LIOB-588, L-INX Configurator devices (all versions) use cleartext HTTP for login.
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device.
If Thunderbird is configured to use STARTTLS for an IMAP server, and the server sends a PREAUTH response, then Thunderbird will continue with an unencrypted connection, causing email data to be sent without protection. This vulnerability affects Thunderbird < 68.9.0.
Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker with access to the network could observe sensitive treatment and prescription data sent between the Phoenix system and the Exalis tool.
LOYTEC LINX-151, LINX-212, LVIS-3ME12-A1, LIOB-586, LIOB-580 V2, LIOB-588, L-INX Configurator devices (all versions) send password-change requests via cleartext HTTP.
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device.
An issue was discovered in Castle Rock SNMPc Online 12.10.10 before 2020-01-28. It includes the username and password values in cleartext within each request's cookie value.
LOYTEC electronics GmbH LINX Configurator (all versions) uses HTTP Basic Authentication, which transmits usernames and passwords in base64-encoded cleartext and allows remote attackers to steal the password and gain full control of Loytec device configuration.
Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems use cleartext messages to communicate order information with an order entry system. This could allow an attacker with network access to view sensitive data including PHI.
Grand MA 300 allows retrieval of the access PIN from sniffed data.
LOYTEC electronics GmbH LINX Configurator (all versions) is vulnerable to Insecure Permissions. An admin credential is passed as a value of URL parameters without encryption, so it allows remote attackers to steal the password and gain full control of Loytec device configuration.
A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts HTTP network traffic between a user and the device.
A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts Telnet network traffic between a user and the device.
TLS/SSL weak cipher suites enabled. The following products are affected: Acronis Cyber Protect 15 (Windows, Linux) before build 30984.
Jenkins LDAP Email Plugin transmits configured credentials in plain text as part of the global Jenkins configuration form, potentially resulting in their exposure.
In Fibaro Home Center 2 and Lite devices in all versions provide a web based management interface over unencrypted HTTP protocol. Communication between the user and the device can be eavesdropped to hijack sessions, tokens and passwords.
ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes unencrypted passwords on the network.
ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes a session token on the network.
Procom NetFORCE 800 4.02 M10 Build 20 and possibly other versions sends the NIS password map (passwd.nis) as a file attachment in diagnostic e-mail messages, which allows remote attackers to obtain the cleartext NIS password hashes.
Wrongthink peer-to-peer, end-to-end encrypted messenger with PeerJS and Axolotl ratchet. In wrongthink from version 2.0.0 and before 2.3.0 there was a set of vulnerabilities causing inadequate encryption strength. Part of the secret identity key was disclosed by the fingerprint used for connection. Additionally, the safety number was improperly calculated. It was computed using part of one of the public identity keys instead of being derived from both public identity keys. This caused issues in computing safety numbers which would potentially be exploitable in the real world. Additionally there was inadequate encryption strength due to use of 1024-bit DSA keys. These issues are all fixed in version 2.3.0.
RVTools, Version 3.9.2 and above, contain a sensitive data exposure vulnerability in the password encryption utility (RVToolsPasswordEncryption.exe) and main application (RVTools.exe). A remote unauthenticated attacker with access to stored encrypted passwords from a users' system could potentially exploit this vulnerability, leading to the disclosure of encrypted passwords in clear text. This vulnerability is caused by an incomplete fix for CVE-2020-27688.
IBM Security Information Queue (ISIQ) 1.0.0, 1.0.1, and 1.0.2 is missing the HTTP Strict Transport Security header. Users can navigate by mistake to the unencrypted version of the web application or accept invalid certificates. This leads to sensitive data being sent unencrypted over the wire. IBM X-Force ID: 158661.
Cleartext Transmission of Sensitive InformationCleartext transmission of sensitive information vulnerability in MELSEC iQ-R series Safety CPU R08/16/32/120SFCPU firmware versions "26" and prior and MELSEC iQ-R series SIL2 Process CPU R08/16/32/120PSFCPU firmware versions "11" and prior allows a remote unauthenticated attacker to login to a target CPU module by obtaining credentials other than password.
IBM Security Verify Information Queue 1.0.6 and 1.0.7 could allow a remote attacker to obtain sensitive information, caused by the failure to properly enable HTTP Strict Transport Security. An attacker could exploit this vulnerability to obtain sensitive information using man in the middle techniques. IBM X-Force ID: 196188.
A vulnerability has been identified in COMOS (All versions < V10.4.4). Caching system in the affected application leaks sensitive information such as user and project information in cleartext via UDP.