Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2022-24142

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-04 Feb, 2022 | 01:33
Updated At-03 Aug, 2024 | 04:07
Rejected At-
Credits

Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function formSetFirewallCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via the firewallEn parameter.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:04 Feb, 2022 | 01:33
Updated At:03 Aug, 2024 | 04:07
Rejected At:
▼CVE Numbering Authority (CNA)

Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function formSetFirewallCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via the firewallEn parameter.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://github.com/pjqwudi/my_vuln/blob/main/Tenda/vuln_22/22.md
x_refsource_MISC
Hyperlink: https://github.com/pjqwudi/my_vuln/blob/main/Tenda/vuln_22/22.md
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://github.com/pjqwudi/my_vuln/blob/main/Tenda/vuln_22/22.md
x_refsource_MISC
x_transferred
Hyperlink: https://github.com/pjqwudi/my_vuln/blob/main/Tenda/vuln_22/22.md
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:04 Feb, 2022 | 02:15
Updated At:07 Feb, 2022 | 17:36

Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function formSetFirewallCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via the firewallEn parameter.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.17.5HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Primary2.07.8HIGH
AV:N/AC:L/Au:N/C:N/I:N/A:C
Type: Primary
Version: 3.1
Base score: 7.5
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Type: Primary
Version: 2.0
Base score: 7.8
Base severity: HIGH
Vector:
AV:N/AC:L/Au:N/C:N/I:N/A:C
CPE Matches

Tenda Technology Co., Ltd.
tenda
>>ax3_firmware>>16.03.12.10_cn
cpe:2.3:o:tenda:ax3_firmware:16.03.12.10_cn:*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tenda
>>ax3>>-
cpe:2.3:h:tenda:ax3:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-787Primarynvd@nist.gov
CWE ID: CWE-787
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/pjqwudi/my_vuln/blob/main/Tenda/vuln_22/22.mdcve@mitre.org
Broken Link
Exploit
Third Party Advisory
Hyperlink: https://github.com/pjqwudi/my_vuln/blob/main/Tenda/vuln_22/22.md
Source: cve@mitre.org
Resource:
Broken Link
Exploit
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

1393Records found

CVE-2024-2994
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.53% / 66.39%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 19:31
Updated-15 Jan, 2025 | 18:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 GetParentControlInfo stack-based overflow

A vulnerability was found in Tenda FH1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258163. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2764
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.73% / 71.71%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 20:31
Updated-12 Dec, 2024 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-28535
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8||HIGH
EPSS-0.33% / 55.56%
||
7 Day CHG~0.00%
Published-12 Mar, 2024 | 00:00
Updated-02 Aug, 2024 | 00:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the mitInterface parameter of fromAddressNat function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac18_firmwaren/aac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2892
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.21% / 43.81%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 16:00
Updated-22 Jan, 2025 | 17:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 setcfm formSetCfm stack-based overflow

A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2763
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.84% / 73.71%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 20:31
Updated-12 Dec, 2024 | 17:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U setcfm formSetCfm stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10U
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2893
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.26% / 49.29%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 16:31
Updated-22 Jan, 2025 | 17:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2900
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.95% / 75.41%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 19:31
Updated-22 Jan, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 saveParentControlInfo stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2901
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.13%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 20:00
Updated-22 Jan, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 openSchedWifi setSchedWifi stack-based overflow

A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2805
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.04% / 76.60%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 03:00
Updated-24 Jan, 2025 | 18:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetSpeedWan formSetSpeedWan stack-based overflow

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been rated as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257660. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2899
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.13%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 19:00
Updated-10 Apr, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WifiExtraSet fromSetWirelessRepeat stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2898
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.86% / 74.14%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 18:31
Updated-22 Jan, 2025 | 17:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetStaticRouteCfg fromSetRouteStatic stack-based overflow

A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-25433
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.39% / 59.08%
||
7 Day CHG~0.00%
Published-18 Mar, 2022 | 20:53
Updated-03 Aug, 2024 | 04:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the urls parameter in the saveparentcontrolinfo function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9_firmwareac9n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2896
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.13%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 18:00
Updated-22 Jan, 2025 | 17:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WifiWpsStart formWifiWpsStart stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. This issue affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257939. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2894
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.13%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 17:00
Updated-22 Jan, 2025 | 17:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetNetControlList formSetQosBand stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2705
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.86% / 74.21%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 16:31
Updated-12 Dec, 2024 | 17:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetNetControlList formSetQosBand stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2708
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.44% / 62.32%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 17:31
Updated-12 Dec, 2024 | 17:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U execCommand formexeCommand stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4240
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.37% / 58.15%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 20:31
Updated-27 Jan, 2025 | 18:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 formQosManageDouble_user stack-based overflow

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. This affects the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9w9_firmwareW9w9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-7586
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.10% / 27.61%
||
7 Day CHG~0.00%
Published-14 Jul, 2025 | 08:02
Updated-17 Jul, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 setWtpData formSetAPCfg stack-based overflow

A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. Affected by this vulnerability is the function formSetAPCfg of the file /goform/setWtpData. The manipulation of the argument radio_2g_1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500_firmwareac500AC500
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2581
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.61% / 68.72%
||
7 Day CHG~0.00%
Published-18 Mar, 2024 | 03:00
Updated-22 Jan, 2025 | 17:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 SetStaticRouteCfg fromSetRouteStatic stack-based overflow

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2547
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.24% / 46.68%
||
7 Day CHG~0.00%
Published-17 Mar, 2024 | 03:31
Updated-27 Jan, 2025 | 17:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 R7WebsSecurityHandler stack-based overflow

A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-25440
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.39% / 59.08%
||
7 Day CHG~0.00%
Published-18 Mar, 2022 | 20:53
Updated-03 Aug, 2024 | 04:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the ntpserver parameter in the SetSysTimeCfg function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9_firmwareac9n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-25455
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.39% / 59.08%
||
7 Day CHG~0.00%
Published-18 Mar, 2022 | 20:53
Updated-03 Aug, 2024 | 04:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the list parameter in the SetIpMacBind function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac6_firmwareac6n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-0782
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-7.2||HIGH
EPSS-0.08% / 25.34%
||
7 Day CHG~0.00%
Published-11 Feb, 2023 | 17:00
Updated-24 Mar, 2025 | 14:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC23 httpd formGetSysToolDDNS out-of-bounds write

A vulnerability was found in Tenda AC23 16.03.07.45 and classified as critical. Affected by this issue is the function formSetSysToolDDNS/formGetSysToolDDNS of the file /bin/httpd. The manipulation leads to out-of-bounds write. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-220640.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac23_firmwareac23AC23
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2489
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.22% / 45.02%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 09:00
Updated-10 Apr, 2025 | 20:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetNetControlList formSetQosBand stack-based overflow

A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2486
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.59% / 68.31%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 08:00
Updated-14 Jan, 2025 | 15:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256893 was assigned to this vulnerability.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2488
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.26% / 48.86%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 09:00
Updated-14 Jan, 2025 | 15:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetPptpServerCfg formSetPPTPServer stack-based overflow

A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIP leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256895. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-7596
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.10% / 27.61%
||
7 Day CHG~0.00%
Published-14 Jul, 2025 | 10:32
Updated-17 Jul, 2025 | 17:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 WifiExtraSet formWifiExtraSet stack-based overflow

A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been rated as critical. This issue affects the function formWifiExtraSet of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205fh1205_firmwareFH1205
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5978
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 30.31%
||
7 Day CHG~0.00%
Published-10 Jun, 2025 | 20:31
Updated-20 Jun, 2025 | 14:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 VirtualSer fromVirtualSer stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14. It has been classified as critical. Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5855
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.16% / 37.39%
||
7 Day CHG~0.00%
Published-09 Jun, 2025 | 01:31
Updated-09 Jun, 2025 | 19:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 SetRebootTimer formSetRebootTimer stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC6 15.03.05.16. This affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6ac6_firmwareAC6
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-6111
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 29.41%
||
7 Day CHG~0.00%
Published-16 Jun, 2025 | 07:00
Updated-17 Jun, 2025 | 19:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 VirtualSer fromVirtualSer stack-based overflow

A vulnerability classified as critical was found in Tenda FH1205 2.0.0.7(775). This vulnerability affects the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5853
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.17% / 38.92%
||
7 Day CHG~0.00%
Published-09 Jun, 2025 | 00:31
Updated-09 Jun, 2025 | 19:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow

A vulnerability classified as critical was found in Tenda AC6 15.03.05.16. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6ac6_firmwareAC6
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5863
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.16% / 37.39%
||
7 Day CHG~0.00%
Published-09 Jun, 2025 | 05:31
Updated-10 Jun, 2025 | 14:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC5 SetRebootTimer formSetRebootTimer stack-based overflow

A vulnerability was found in Tenda AC5 15.03.06.47. It has been classified as critical. Affected is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac5ac5_firmwareAC5
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-6110
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.15% / 36.67%
||
7 Day CHG~0.00%
Published-16 Jun, 2025 | 06:31
Updated-17 Jun, 2025 | 19:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1201 SafeMacFilter stack-based overflow

A vulnerability classified as critical has been found in Tenda FH1201 1.2.0.14(408). This affects an unknown part of the file /goform/SafeMacFilter. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1201fh1201_firmwareFH1201
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5685
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.16% / 37.39%
||
7 Day CHG~0.00%
Published-05 Jun, 2025 | 20:00
Updated-10 Jun, 2025 | 15:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 Natlimit formNatlimit stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda CH22 1.0.0.1. This affects the function formNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22ch22_firmwareCH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5527
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 34.73%
||
7 Day CHG~0.00%
Published-03 Jun, 2025 | 20:31
Updated-09 Jun, 2025 | 15:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX3 SetStaticRouteCfg save_staticroute_data stack-based overflow

A vulnerability was found in Tenda RX3 16.03.13.11_multi_TDE01. It has been rated as critical. This issue affects the function save_staticroute_data of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx3_firmwarerx3RX3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5619
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.16% / 37.39%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 23:00
Updated-06 Jun, 2025 | 20:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 addUserName formaddUserName stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda CH22 1.0.0.1. This issue affects the function formaddUserName of the file /goform/addUserName. The manipulation of the argument Password leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22ch22_firmwareCH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-37808
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.44% / 62.09%
||
7 Day CHG+0.24%
Published-25 Aug, 2022 | 14:06
Updated-03 Aug, 2024 | 10:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the index parameter in the function formWifiWpsOOB.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac1206_firmwareac1206n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5080
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.12% / 32.49%
||
7 Day CHG~0.00%
Published-22 May, 2025 | 15:00
Updated-20 Jun, 2025 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH451 webExcptypemanFilter stack-based overflow

A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Affected is the function webExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh451_firmwarefh451FH451
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-11745
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.36% / 57.65%
||
7 Day CHG~0.00%
Published-26 Nov, 2024 | 21:00
Updated-03 Dec, 2024 | 15:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 SetStaticRouteCfg route_static_check stack-based overflow

A vulnerability was found in Tenda AC8 16.03.34.09 and classified as critical. Affected by this issue is the function route_static_check of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8ac8_firmwareAC8ac8_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2018-18729
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.45% / 62.67%
||
7 Day CHG~0.00%
Published-28 Oct, 2018 | 00:00
Updated-05 Aug, 2024 | 11:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router's web server -- httpd. While processing the 'mac' parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac7ac10_firmwareac7_firmwareac18ac10ac9ac9_firmwareac15ac15_firmwareac18_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10662
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.74% / 71.91%
||
7 Day CHG+0.11%
Published-01 Nov, 2024 | 16:00
Updated-05 Nov, 2024 | 15:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability was found in Tenda AC15 15.03.05.19 and classified as critical. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10698
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.70% / 71.17%
||
7 Day CHG+0.10%
Published-02 Nov, 2024 | 13:31
Updated-05 Nov, 2024 | 15:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability was found in Tenda AC6 15.03.05.19 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6_firmwareac6AC6ac6_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-4810
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 29.41%
||
7 Day CHG~0.00%
Published-16 May, 2025 | 20:31
Updated-24 May, 2025 | 01:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetRebootTimer formSetRebootTimer stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. Affected by this vulnerability is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument reboot_time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10661
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.72% / 71.55%
||
7 Day CHG+0.11%
Published-01 Nov, 2024 | 16:00
Updated-05 Nov, 2024 | 15:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetDlnaCfg stack-based overflow

A vulnerability has been found in Tenda AC15 15.03.05.19 and classified as critical. This vulnerability affects the function SetDlnaCfg of the file /goform/SetDlnaCfg. The manipulation of the argument scanList leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-0541
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.22% / 44.79%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 05:00
Updated-12 May, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 httpd formAddSysLogRule stack-based overflow

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. Affected by this vulnerability is the function formAddSysLogRule of the component httpd. The manipulation of the argument sysRulenEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-250711. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9_firmwarew9W9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10351
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.48% / 64.25%
||
7 Day CHG~0.00%
Published-24 Oct, 2024 | 23:31
Updated-01 Nov, 2024 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX9 Pro POST Request setMacFilterCfg sub_424CE0 stack-based overflow

A vulnerability was found in Tenda RX9 Pro 22.03.02.20. It has been rated as critical. This issue affects the function sub_424CE0 of the file /goform/setMacFilterCfg of the component POST Request Handler. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx9_prorx9_pro_firmwareRX9 Prorx9_pro_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-0991
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-7.2||HIGH
EPSS-0.10% / 27.28%
||
7 Day CHG~0.00%
Published-29 Jan, 2024 | 01:00
Updated-18 Oct, 2024 | 14:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i6 httpd setcfm formSetCfm stack-based overflow

A vulnerability has been found in Tenda i6 1.0.0.9(3857) and classified as critical. This vulnerability affects the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252256. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i6i6_firmwarei6i6
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-0994
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-7.2||HIGH
EPSS-0.10% / 27.28%
||
7 Day CHG~0.00%
Published-29 Jan, 2024 | 01:31
Updated-12 Nov, 2024 | 21:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W6 httpd setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda W6 1.0.0.9(4122). It has been declared as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252259. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w6w6_firmwareW6
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-0532
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.6||HIGH
EPSS-0.34% / 55.87%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 02:00
Updated-14 May, 2025 | 14:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A15 Web-based Management Interface WifiExtraSet set_repeat5 stack-based overflow

A vulnerability was found in Tenda A15 15.13.07.13. It has been declared as critical. This vulnerability affects the function set_repeat5 of the file /goform/WifiExtraSet of the component Web-based Management Interface. The manipulation of the argument wpapsk_crypto2_4g/wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a15a15_firmwareA15
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10434
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.00% / 76.11%
||
7 Day CHG+0.15%
Published-28 Oct, 2024 | 00:31
Updated-01 Nov, 2024 | 16:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC1206 ate ate_Tenda_mfg_check_usb3 stack-based overflow

A vulnerability was found in Tenda AC1206 up to 20241027. It has been classified as critical. This affects the function ate_Tenda_mfg_check_usb/ate_Tenda_mfg_check_usb3 of the file /goform/ate. The manipulation of the argument arg leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac1206_firmwareac1206AC1206ac1206
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
  • Previous
  • 1
  • 2
  • ...
  • 6
  • 7
  • 8
  • ...
  • 27
  • 28
  • Next
Details not found