Vulnerability in Fidelis Network and Deception CommandPost enables authenticated command injection through the web interface. The vulnerability could allow a specially crafted HTTP request to execute system commands on the CommandPost and return results in an HTTP response in an authenticated session. The vulnerability is present in Fidelis Network and Deception versions prior to 9.3.7 and in version 9.4. Patches and updates are available to address this vulnerability.
Vulnerability in the CommandPost, Collector, and Sensor components of Fidelis Network and Deception enables an attacker with user level access to the CLI to inject root level commands into the component and neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.3.7 and in version 9.4. Patches and updates are available to address this vulnerability.
Vulnerability in rconfig “remote_text_file” enables an attacker with user level access to the CLI to inject user level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.
Vulnerability in rconfig “date” enables an attacker with user level access to the CLI to inject root level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.
Vulnerability in Fidelis Network and Deception CommandPost enables authenticated command injection through the web interface using the “feed_comm_test” value for the “feed” parameter. The vulnerability could allow a specially crafted HTTP request to execute system commands on the CommandPost and return results in an HTTP response via an authenticated session. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.
Vulnerability in rconfig “cert_utils” enables an attacker with user level access to the CLI to inject root level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.
Vulnerability in Fidelis Network and Deception CommandPost enables authenticated command injection through the web interface using the “update_checkfile” value for the “filename” parameter. The vulnerability could allow a specially crafted HTTP request to execute system commands on the CommandPost and return results in an HTTP response via an authenticated session. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.
Vulnerability in Fidelis Network and Deception CommandPost enables SQL injection through the web interface by an attacker with user level access. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.
TOTOLINK X5000R V9.1.0cu.2350_B20230313 was discovered to contain an OS command injection vulnerability via the "switch" parameter in setScheduleCfg.
TOTOLINK X5000R V9.1.0cu.2350_B20230313 was discovered to contain an OS command injection vulnerability via the "hour" parameter in setScheduleCfg.
TOTOLINK X5000R V9.1.0cu.2350_B20230313 was discovered to contain an OS command injection vulnerability via the "pass" parameter in setVpnAccountCfg.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects GC108P before 1.0.8.2, GC108PP before 1.0.8.2, GS108Tv3 before 7.0.7.2, GS110TPv3 before 7.0.7.2, GS110TPP before 7.0.7.2, GS110TUP before 1.0.5.3, GS710TUP before 1.0.5.3, GS308T before 1.0.3.2, GS310TP before 1.0.3.2, GS710TUP before 1.0.5.3, GS716TP before 1.0.4.2, GS716TPP before 1.0.4.2, GS724TPP before 2.0.6.3, GS724TPv2 before 2.0.6.3, GS724TPP before 2.0.6.3, GS728TPPv2 before 6.0.8.2, GS728TPv2 before 6.0.8.2, GS752TPv2 before 6.0.8.2, GS752TPP before 6.0.8.2, GS750E before 1.0.1.10, MS510TXM before 1.0.4.2, and MS510TXUP before 1.0.4.2.
TOTOLINK X5000R V9.1.0cu.2350_B20230313 was discovered to contain an OS command injection vulnerability via the "user" parameter in setVpnAccountCfg.
TOTOLINK X5000R V9.1.0cu.2350_B20230313 was discovered to contain an OS command injection vulnerability via the "week" parameter in setScheduleCfg.
TOTOLINK X5000R V9.1.0cu.2350_B20230313 was discovered to contain an OS command injection vulnerability via the "sMinute" parameter in setWiFiScheduleCfg.
An issue was discovered on Vera VeraEdge 1.7.19 and Veralite 1.7.481 devices. The device provides a web user interface that allows a user to manage the device. As a part of the functionality the device firmware file contains a file known as relay.sh which allows the device to create relay ports and connect the device to Vera servers. This is primarily used as a method of communication between the device and Vera servers so the devices can be communicated with even when the user is not at home. One of the parameters retrieved by this specific script is "remote_host". This parameter is not sanitized by the script correctly and is passed in a call to "eval" to execute another script where remote_host is concatenated to be passed a parameter to the second script. This allows an attacker to escape from the executed command and then execute any commands of his/her choice.
RELY-PCIe v22.2.1 to v23.1.0 was discovered to contain a code injection vulnerability via the getParams function in phpinf.php.
TOTOLINK X5000R V9.1.0cu.2350_B20230313 was discovered to contain an OS command injection vulnerability via the "minute" parameters in setScheduleCfg.
TOTOLINK X5000R V9.1.0cu.2350_B20230313 was discovered to contain an OS command injection vulnerability via the "recHour" parameter in setScheduleCfg.
A command injection was identified on Barco ClickShare Base Unit devices with CSM-1 firmware before 1.7.0.3 and CSC-1 firmware before 1.10.0.10. An attacker with access to the product's web API can exploit this vulnerability to completely compromise the vulnerable device.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
Tuleap before 9.7 allows command injection via the PhpWiki 1.3.10 SyntaxHighlighter plugin. This occurs in the Project Wiki component because the proc_open PHP function is used within PhpWiki before 1.5.5 with a syntax value in its first argument, and an authenticated Tuleap user can control this value, even with shell metacharacters, as demonstrated by a '<?plugin SyntaxHighlighter syntax="c;id"' line to execute the id command.
The KuWFi 4G AC900 LTE router 1.0.13 is vulnerable to command injection on the HTTP API endpoints /goform/formMultiApnSetting and /goform/atCmd. An authenticated attacker can execute arbitrary OS commands with root privileges via shell metacharacters in parameters such as pincode and cmds. Exploitation can lead to full system compromise, including enabling remote access (e.g., enabling telnet).
Openfind Mail2000 does not properly filter parameters of specific CGI. Remote attackers with regular privileges can exploit this vulnerability to execute arbitrary system commands on the remote server.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, and RBS850 before 3.2.17.12.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7000 before 1.0.11.126, R6900P before 1.3.2.126, and R7000P before 1.3.2.126.
CyberPanel before 2.3.8 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the phpSelection field to the websites/submitWebsiteCreation URI.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6200 before 1.1.00.40, D7000 before 1.0.1.78, R6020 before 1.0.0.42, R6080 before 1.0.0.42, R6050 before 1.0.1.26, JR6150 before 1.0.1.26, R6120 before 1.0.0.66, R6220 before 1.1.0.110, R6230 before 1.1.0.110, R6260 before 1.1.0.64, R6800 before 1.2.0.62, R6700v2 before 1.2.0.62, R6900v2 before 1.2.0.62, R7450 before 1.2.0.62, AC2100 before 1.2.0.62, AC2400 before 1.2.0.62, AC2600 before 1.2.0.62, and WNR2020 before 1.1.0.62.
StepSecurity's Harden-Runner provides network egress filtering and runtime security for GitHub-hosted and self-hosted runners. Versions of step-security/harden-runner prior to v2.10.2 contain multiple command injection weaknesses via environment variables that could potentially be exploited under specific conditions. However, due to the current execution order of pre-steps in GitHub Actions and the placement of harden-runner as the first step in a job, the likelihood of exploitation is low as the Harden-Runner action reads the environment variable during the pre-step stage. There are no known exploits at this time. Version 2.10.2 contains a patch.
TP-Link C2 and C20i devices through firmware 0.9.1 4.2 v0032.0 Build 160706 Rel.37961n allow remote code execution with a single HTTP request by placing shell commands in a "host=" line within HTTP POST data.
In Horde_Crypt before 2.7.6, as used in Horde Groupware Webmail Edition through 5.2.17, OS Command Injection can occur if the attacker is an authenticated Horde Webmail user, has PGP features enabled in their preferences, and attempts to encrypt an email addressed to a maliciously crafted email address.
An issue was discovered on Securifi Almond, Almond+, and Almond 2015 devices with firmware AL-R096. The device provides a user with the capability of adding new routes to the device. It seems that the POST parameters passed in this request to set up routes on the device can be set in such a way that would result in passing commands to a "popen" API in the function and thus result in command injection on the device. If the firmware version AL-R096 is dissected using binwalk tool, we obtain a cpio-root archive which contains the filesystem set up on the device that contains all the binaries. The binary "goahead" is the one that has the vulnerable function that receives the values sent by the POST request. If we open this binary in IDA-pro we will notice that this follows a MIPS little endian format. The function sub_00420F38 in IDA pro is identified to be receiving the values sent in the POST request and the value set in POST parameter "dest" is extracted at address 0x00420FC4. The POST parameter "dest is concatenated in a route add command and this is passed to a "popen" function at address 0x00421220. This allows an attacker to provide the payload of his/her choice and finally take control of the device.
NETGEAR D6220 devices before 1.0.0.76 are affected by command injection by an authenticated user.
FusionSphere V100R006C00SPC102(NFV) has a command injection vulnerability. An authenticated, remote attacker could craft packets with malicious strings and send them to a target device. Successful exploit could allow the attacker to launch a command injection attack and execute system commands.
An improper neutralization of special elements used in an OS Command vulnerability [CWE-78] in Fortinet FortiSandbox version 5.0.0, 4.4.0 through 4.4.7, 4.2.0 through 4.2.7 and before 4.0.5 allows an authenticated attacker with at least read-only permission to execute unauthorized commands via crafted requests.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects LBR20 before 2.6.3.50, RBS50Y before 2.7.3.22, RBR10 before 2.7.3.22, RBR20 before 2.7.3.22, RBR40 before 2.7.3.22, RBR50 before 2.7.3.22, RBS10 before 2.7.3.22, RBS20 before 2.7.3.22, RBS40 before 2.7.3.22, RBS50 before 2.7.3.22, RBK12 before 2.7.3.22, RBK20 before 2.7.3.22, RBK40 before 2.7.3.22, and RBK50 before 2.7.3.22.
dnslookup.cgi on NETGEAR DGN2200 devices with firmware through 10.0.0.50 allows remote authenticated users to execute arbitrary OS commands via shell metacharacters in the host_name field of an HTTP POST request, a different vulnerability than CVE-2017-6077.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7900 before 1.0.4.38, R7900P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6.
In Draytek Vigor3900 1.5.1.3, attackers can inject malicious commands into mainfunction.cgi and execute arbitrary commands by calling the pingtrace function.
In Draytek Vigor3900 1.5.1.3, attackers can inject malicious commands into mainfunction.cgi and execute arbitrary commands by calling the packet_monitor function.
The Symantec Messaging Gateway before 10.6.3-267 can encounter an issue of remote code execution, which describes a situation whereby an individual may obtain the ability to execute commands remotely on a target machine or in a target process. In this type of occurrence, after gaining access to the system, the attacker may attempt to elevate their privileges.
Ruckus Networks Unleashed AP firmware releases before 200.6.10.1.x and Ruckus Networks Zone Director firmware releases 10.1.0.0.x, 9.10.2.0.x, 9.12.3.0.x, 9.13.3.0.x, 10.0.1.0.x or before contain authenticated Root Command Injection in the CLI that could allow authenticated valid users to execute privileged commands on the respective systems.
The theme.php file in SDCMS 2.8 has a command execution vulnerability that allows for the execution of system commands
A vulnerability in the HPE Aruba Networking ClearPass Policy Manager web-based management interface could allow an authenticated remote threat actor to conduct a remote code execution attack. Successful exploitation could enable the attacker to run arbitrary commands on the underlying operating system.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.60, DM200 before 1.0.0.66, EX2700 before 1.0.1.56, EX6150v2 before 1.0.1.86, EX6200v2 before 1.0.1.86, EX6250 before 1.0.0.128, EX6400 before 1.0.2.144, EX6400v2 before 1.0.0.128, EX6410 before 1.0.0.128, EX6420 before 1.0.0.128, EX7300 before 1.0.2.144, EX7300v2 before 1.0.0.128, EX7320 before 1.0.0.128, R7500v2 before 1.0.3.46, R7800 before 1.0.2.74, R8900 before 1.0.5.26, R9000 before 1.0.5.2, RAX120 before 1.0.1.128, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.80, WNR2000v5 before 1.0.0.74, XR500 before 2.3.2.66, RBK20 before 2.7.3.22, RBR20 before 2.7.3.22, RBS20 before 2.7.3.22, RBK40 before 2.7.3.22, RBR40 before 2.7.3.22, and RBS40 before 2.7.3.22.
NfSen before 1.3.8 allows remote attackers to execute arbitrary OS commands via shell metacharacters in the customfmt parameter (aka the "Custom output format" field).
An issue was discovered in Trend Micro InterScan Messaging Security (Virtual Appliance) 9.1-1600. An authenticated user can execute a terminal command in the context of the web server user (which is root). Besides, the default installation of IMSVA comes with default administrator credentials. The saveCert.imss endpoint takes several user inputs and performs blacklisting. After that, it uses them as arguments to a predefined operating-system command without proper sanitization. However, because of an improper blacklisting rule, it's possible to inject arbitrary commands into it.
DrayTek Vigor3900 1.5.1.3 allows attackers to inject malicious commands into mainfunction.cgi and execute arbitrary commands by calling the doCertificate function.
Ruckus Networks Solo APs firmware releases R110.x or before and Ruckus Networks SZ managed APs firmware releases R5.x or before contain authenticated Root Command Injection in the web-GUI that could allow authenticated valid users to execute privileged commands on the respective systems.