Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2022-24408

Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-08 Mar, 2022 | 11:31
Updated At-03 Aug, 2024 | 04:13
Rejected At-
Credits

A vulnerability has been identified in SINUMERIK MC (All versions < V1.15 SP1), SINUMERIK ONE (All versions < V6.15 SP1). The sc SUID binary on affected devices provides several commands that are used to execute system commands or modify system files. A specific set of operations using sc could allow local attackers to escalate their privileges to root.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:08 Mar, 2022 | 11:31
Updated At:03 Aug, 2024 | 04:13
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in SINUMERIK MC (All versions < V1.15 SP1), SINUMERIK ONE (All versions < V6.15 SP1). The sc SUID binary on affected devices provides several commands that are used to execute system commands or modify system files. A specific set of operations using sc could allow local attackers to escalate their privileges to root.

Affected Products
Vendor
Siemens AGSiemens
Product
SINUMERIK MC
Versions
Affected
  • All versions < V1.15 SP1
Vendor
Siemens AGSiemens
Product
SINUMERIK ONE
Versions
Affected
  • All versions < V6.15 SP1
Problem Types
TypeCWE IDDescription
CWECWE-269CWE-269: Improper Privilege Management
Type: CWE
CWE ID: CWE-269
Description: CWE-269: Improper Privilege Management
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-337210.pdf
x_refsource_MISC
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-337210.pdf
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-337210.pdf
x_refsource_MISC
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-337210.pdf
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:08 Mar, 2022 | 12:15
Updated At:11 Mar, 2022 | 18:50

A vulnerability has been identified in SINUMERIK MC (All versions < V1.15 SP1), SINUMERIK ONE (All versions < V6.15 SP1). The sc SUID binary on affected devices provides several commands that are used to execute system commands or modify system files. A specific set of operations using sc could allow local attackers to escalate their privileges to root.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.17.8HIGH
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary2.07.2HIGH
AV:L/AC:L/Au:N/C:C/I:C/A:C
Type: Primary
Version: 3.1
Base score: 7.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 7.2
Base severity: HIGH
Vector:
AV:L/AC:L/Au:N/C:C/I:C/A:C
CPE Matches

Siemens AG
siemens
>>sinumerik_mc_firmware>>Versions before 1.15(exclusive)
cpe:2.3:o:siemens:sinumerik_mc_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinumerik_mc_firmware>>1.15
cpe:2.3:o:siemens:sinumerik_mc_firmware:1.15:-:*:*:*:*:*:*
Siemens AG
siemens
>>sinumerik_mc>>-
cpe:2.3:h:siemens:sinumerik_mc:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinumerik_one_firmware>>Versions before 6.15(exclusive)
cpe:2.3:o:siemens:sinumerik_one_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinumerik_one_firmware>>6.15
cpe:2.3:o:siemens:sinumerik_one_firmware:6.15:-:*:*:*:*:*:*
Siemens AG
siemens
>>sinumerik_one>>-
cpe:2.3:h:siemens:sinumerik_one:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-269Primarynvd@nist.gov
CWE-269Secondaryproductcert@siemens.com
CWE ID: CWE-269
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-269
Type: Secondary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/pdf/ssa-337210.pdfproductcert@siemens.com
Mitigation
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-337210.pdf
Source: productcert@siemens.com
Resource:
Mitigation
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

0Records found

CVE-2020-15797
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.8||MEDIUM
EPSS-0.28% / 51.29%
||
7 Day CHG~0.00%
Published-13 Oct, 2020 | 15:30
Updated-04 Aug, 2024 | 13:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in DCA Vantage Analyzer (All versions < V4.5 are affected by CVE-2020-7590. In addition, serial numbers < 40000 running software V4.4.0 are also affected by CVE-2020-15797). Improper Access Control could allow an unauthenticated attacker to escape from the restricted environment (“kiosk mode”) and access the underlying operating system. Successful exploitation requires direct physical access to the system.

Action-Not Available
Vendor-Siemens AG
Product-dca_vantage_analyzer_firmwaredca_vantage_analyzerDCA Vantage Analyzer
CWE ID-CWE-269
Improper Privilege Management
CVE-2020-10056
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.05% / 13.59%
||
7 Day CHG~0.00%
Published-09 Sep, 2020 | 18:10
Updated-04 Aug, 2024 | 10:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in License Management Utility (LMU) (All versions < V2.4). The lmgrd service of the affected application is executed with local SYSTEM privileges on the server while its configuration can be modified by local users. The vulnerability could allow a local authenticated attacker to execute arbitrary commands on the server with local SYSTEM privileges.

Action-Not Available
Vendor-Siemens AG
Product-license_management_utilityLicense Management Utility (LMU)
CWE ID-CWE-250
Execution with Unnecessary Privileges
CWE ID-CWE-269
Improper Privilege Management
CVE-2020-27003
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.12% / 31.03%
||
7 Day CHG~0.00%
Published-09 Feb, 2021 | 15:38
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing TIFF files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12158)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-822
Untrusted Pointer Dereference
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2018-3657
Matching Score-8
Assigner-Intel Corporation
ShareView Details
Matching Score-8
Assigner-Intel Corporation
CVSS Score-6.7||MEDIUM
EPSS-0.26% / 49.54%
||
7 Day CHG~0.00%
Published-12 Sep, 2018 | 19:00
Updated-16 Sep, 2024 | 20:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple buffer overflows in Intel AMT in Intel CSME firmware versions before version 12.0.5 may allow a privileged user to potentially execute arbitrary code with Intel AMT execution privilege via local access.

Action-Not Available
Vendor-Intel CorporationSiemens AG
Product-manageability_engine_firmwaresimatic_ipc677d_firmwaresimatic_ipc477e_firmwaresimatic_ipc427e_firmwaresimatic_ipc647d_firmwaresimatic_ipc427esimatic_ipc647dsimatic_ipc547e_firmwaresimatic_ipc627dsimatic_pc547esimatic_ipc847dsimatic_ipc827dsimatic_ipc547gsimatic_field_pg_m5_firmwaresimatic_ipc847d_firmwaresimatic_pc547g_firmwaresimatic_ipc677dsimatic_ipc627d_firmwaresimatic_itp1000_firmwaresimatic_ipc827d_firmwareconverged_security_management_engine_firmwaresimatic_ipc477esimatic_field_pg_m5simatic_itp1000active_management_technology_firmwareIntel(R) Active Management Technology
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-31808
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.07% / 22.48%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 10:36
Updated-20 Mar, 2025 | 20:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V2.85.44), SiPass integrated ACC-AP (All versions < V2.85.43). Affected devices improperly sanitize user input on the telnet command line interface. This could allow an authenticated user to escalate privileges by injecting arbitrary commands that are executed with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-sipass_integrated_acc-apsipass_integrated_acc-ap_firmwaresipass_integrated_ac5102_\(acc-g2\)_firmwaresipass_integrated_ac5102_\(acc-g2\)SiPass integrated AC5102 (ACC-G2)SiPass integrated ACC-AP
CWE ID-CWE-20
Improper Input Validation
CVE-2017-5711
Matching Score-8
Assigner-Intel Corporation
ShareView Details
Matching Score-8
Assigner-Intel Corporation
CVSS Score-7.8||HIGH
EPSS-0.15% / 35.97%
||
7 Day CHG~0.00%
Published-21 Nov, 2017 | 14:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple buffer overflows in Active Management Technology (AMT) in Intel Manageability Engine Firmware 8.x/9.x/10.x/11.0/11.5/11.6/11.7/11.10/11.20 allow attacker with local access to the system to execute arbitrary code with AMT execution privilege.

Action-Not Available
Vendor-ASUS (ASUSTeK Computer Inc.)Siemens AGIntel Corporation
Product-rog_strix_z270g_gaming_firmwareh110-plus_firmwareh170m-plus\/brsimatic_ipc627dprime_h110m-ptuf_z270_mark_2rog_strix_z270h_gaming\/k1prime_j3355i-cb150i_pro_gaming\/aurasimatic_ipc827ch110m-a\/dp_firmwaresimatic_ipc477d_firmwareq170t_firmwareb250m-f_plush110m-ksh110m-a_d3ex-b150m-v5rog_strix_b250i_gaming_firmwareh170_pro_gamingsimotion_p320-4strooper_b150_d3_firmwareh110s2b150m-dtuf_z370-plus_gaming_firmwareh110m-ts_firmwaresimatic_ipc647d_firmwareb150-asimatic_ipc477db150m-plus_d3_firmwarerog_maximus_viii_hero_firmwarerog_strix_z270f_gamingrog_maximus_viii_ranger_firmwareb150m-v_plus_firmwareprime_q270m-ch110-plush110s2_firmwareh110m-e_firmwareprime_h110m2\/fpt_firmwaresabertooth_z170_mark_1h110m-c\/hdmi_firmwaresinumerik_pcu50.5-p_firmwaretuf_z370-pro_gaming_firmwarerog_maximus_viii_hero_alpha_firmwarerog_maximus_ix_hero_firmwarez170-krog_strix_b250g_gaming_firmwarerog_strix_z370-f_gamingb150m-ah110m-aex-b250m-v5z170-prosimatic_ipc477eb150m-k_d3prime_h110m2_firmwarerog_maximus_viii_formulaprime_b250m-dsimatic_field_pg_m3_firmwarerog_maximus_ix_extremesimatic_ipc677cb150m-k_firmwareq170s1_firmwareex-b150m-v3_firmwareprime_b250m-jb150m-a_d3_firmwarez170m-e_d3z170-k_firmwarepio-b150m_firmwarerog_strix_h270i_gaming_firmwareh170m-plush110m-ks_r1_firmwareex-b250-v7b150m-plusz170-ar_firmwareh110m-plusb150m-v_plush110m-kex-b150-v7_firmwareh110m-a_d3_firmwarerog_strix_b250h_gaming_firmwareh110m-c\/br_firmwarez170m-plus\/brprime_h270-plus_firmwareprime_h110m2\/fptprime_z270m-plus\/br_firmwareh110t-a_firmwareh110i-plus_firmwaresimatic_ipc627d_firmwaresimatic_field_pg_m3prime_z270-kh170i-pro_firmwaresimatic_field_pg_m4simatic_ipc627ch170i-prob150m-plus_d3z170-premium_firmwaresabertooth_z170_mark_1_firmwareb150m-f_plush170m-e_d3z170-eb150-pro_firmwarepio-b150mrog_maximus_ix_codeprime_b250-plus_firmwareh110m-c_firmwarerog_maximus_x_hero_firmwaresimatic_itp1000simatic_ipc427d_firmwareh110m-e\/m.2_firmwareprime_h110m2rog_maximus_x_formularog_maximus_x_formula_firmwareh110m-d\/exper\/sib150_pro_gaming\/aura_firmwaremanageability_engine_firmwarerog_maximus_ix_herorog_strix_z270i_gamingh170-plus_d3_firmwareex-b150m-v_firmwareq170m-cm-brog_strix_z370-g_gamingprime_z270-arb150-pro_d3rog_strix_z270h_gamingh110m-cs\/br_firmwarerog_strix_z370-i_gamingrog_strix_z370-h_gaming_firmwareh110m-d_firmwaresabertooth_z170_sb150_pro_gamingh110m-a\/m.2q270m-cm-asimatic_ipc847c_firmwareh110m-rh170-pro\/usb_3.1_firmwareq170m2_firmwareb150m-kprime_z270m-plus_firmwareh110m-a_firmwareex-h110m-v3_firmwareh110m-k_x_firmwarez170m-e_d3_firmwareh170_pro_gaming_firmwareb150m-k_d3_firmwarerog_strix_z270f_gaming_firmwarerog_strix_b250f_gamingh110m-cs\/brq170s1ex-b250-v7_firmwaresabertooth_z170_s_firmwarerog_strix_b250h_gamingh110m-d\/exper\/si_firmwareex-b150m-v5_firmwareprime_b250m-d_firmwareh110m-p\/dvib150i_pro_gaming\/aura_firmwaresimatic_ipc647db150m-f_plus_firmwareh110m-ks_r1h110m-c\/ps_firmwareb150-proprime_h270-proex-h110m-v_firmwareex-b250m-v3rog_strix_z270g_gamingrog_maximus_ix_formula_firmwarerog_maximus_viii_gene_firmwareprime_z270-p_firmwareex-h110m-v3h110m-c2\/tf_firmwarez170-p_firmwareq270-sactive_management_technology_firmwaresimatic_ipc427e_firmwarez170m-plustrooper_h110_d3z170-deluxe_firmwaresimatic_ipc547d_firmwaresimatic_ipc847cprime_q270m-c_firmwaresimatic_ipc547dh170m-plus_firmwareb250_mining_expert_firmwarerog_strix_h270i_gamingrog_strix_z270h_gaming\/k1_firmwareprime_z370-pz170-e_firmwarerog_maximus_viii_extreme_firmwareb250_mining_expertb150m-a_d3simatic_ipc677dh110m-c2prime_b250m-a_firmwaresimatic_ipc627c_firmwareprime_b250m-plus\/br_firmwarez170-ah110m-k_firmwaretuf_z270_mark_1_firmwareb150_pro_gaming_d3q170m-c_firmwarez170_pro_gaming\/auraex-b250m-vh110m-a\/m.2_firmwareb150m-d_firmwarerog_strix_b250f_gaming_firmwareprime_z370-a_firmwaresinumerik_pcu50.5-crog_maximus_x_code_firmwarerog_maximus_viii_impactsimatic_ipc827d_firmwareprime_b250m-plus_firmwarez170-deluxeb150m-cprime_b250m-plush110m-cs_xb150-pro_d3_firmwareprime_b250-proz170-a_firmwareb150_pro_gaming_d3_firmwareb150-plusprime_z270-a_firmwareprime_z270-k_firmwareh110m-c\/hdmisimatic_itp1000_firmwareprime_b250-a_firmwareprime_b250-arog_maximus_viii_geneh110t-aex-b250m-v5_firmwaresimatic_ipc647c_firmwareb150-a_firmwaresimatic_ipc427drog_maximus_viii_impact_firmwareq170th110m-r_firmwareh110m-crog_maximus_ix_apex_firmwareprime_z270-ar_firmwarez170_pro_gaming\/aura_firmwareh110m-fprime_b250m-k_firmwareprime_b250m-j_firmwarerog_strix_z370-e_gamingprime_b250m-c_firmwarerog_strix_z270i_gaming_firmwareprime_b250m-ah110m-p\/dvi_firmwareb150m-a_firmwareh170-plus_d3h110m-c\/brrog_strix_b250g_gamingb250-srog_maximus_ix_extreme_firmwareprime_z270m-plusb150_pro_gaming_firmwareex-b150-v7prime_j3355i-c_firmwareb150m-c_d3_firmwaresimatic_ipc427eprime_b250-pro_firmwareh110tq170m2\/cdm\/sib150m-a\/m.2z170_pro_gaming_firmwarerog_strix_z270e_gaming_firmwareb150m-c_firmwarerog_strix_z370-e_gaming_firmwareb150_pro_gaming\/auraq170m2prime_b250m-kprime_z370-aex-h110m-vh110m-dq170t_v2b150m-plus_firmwaresimatic_ipc647csinumerik_pcu50.5-c_firmwareb150m-a\/m.2_firmwareprime_h110m-p_firmwarez170-pro_firmwaresimatic_ipc847dh110m-k_d3z170-premiumex-b250m-v_firmwarerog_strix_z370-g_gaming_firmwareh110i-plussimatic_ipc477d_pro_firmwareb250m-f_plus_firmwarerog_maximus_viii_rangerh110m-plus_firmwareh110m-f_firmwareex-b150m-vtrooper_h110_d3_firmwarerog_maximus_x_apex_firmwarez170i_pro_gamingsimatic_field_pg_m5_firmwaretrooper_b150_d3simatic_ipc677d_firmwarerog_maximus_ix_apexh110m-a\/dpb150m-c\/brrog_strix_z370-i_gaming_firmwareh170-pro_firmwareb150i_pro_gaming\/wifi\/aura_firmwareh110m-erog_maximus_x_heroh110m-cs_firmwareh110m-cssimatic_field_pg_m4_firmwareh110m-cs_x_firmwareb150m-c_d3rog_maximus_viii_extremeh110s1_firmwaretuf_z270_mark_1z170m-plus\/br_firmwareex-b150m-v3prime_z270-pb150-plus_firmwareprime_z370-p_firmwareq170m2\/cdm\/si_firmwarerog_maximus_ix_formulatuf_z370-pro_gamingh170m-e_d3_firmwareb250m-c_prorog_strix_b250i_gamingrog_strix_z370-h_gamingprime_z270m-plus\/brh110m-ks_firmwareb250-mr_firmwareq170m-cm-b_firmwaresimatic_ipc477e_firmwarerog_strix_h270f_gamingrog_strix_z370-f_gaming_firmwareh110s1prime_h270m-plusz170-p_d3prime_b250m-cz170i_pro_gaming_firmwarerog_maximus_viii_heroh110m-tssimatic_ipc477d_propio-b250i_firmwareq170t_v2_firmwareprime_h270m-plus_firmwareb150m-c\/br_firmwareq170m-crog_maximus_x_codetuf_z370-plus_gamingb250-mrh170-prosimatic_ipc547erog_maximus_viii_formula_firmwareb250m-c_pro_firmwarerog_strix_h270f_gaming_firmwareh170-pro\/usb_3.1z170-p_d3_firmwarerog_maximus_x_apexpio-b250ib150m_pro_gaming_firmwarez170m-plus_firmwaresimatic_ipc547e_firmwaresimatic_ipc827dh110m-c\/psh110m-k_d3_firmwarerog_maximus_viii_hero_alphasimatic_field_pg_m5b150i_pro_gaming\/wifi\/aurarog_strix_z270h_gaming_firmwarerog_maximus_ix_code_firmwareprime_h270-pro_firmwareb150m_pro_gamingh110m-c2\/tfq270m-cm-a_firmwareh110m-c2_firmwarerog_strix_z270e_gamingtuf_z270_mark_2_firmwaresimatic_ipc677c_firmwareprime_b250m-plus\/brq270-s_firmwareh110t_firmwareex-b250m-v3_firmwarez170-ph110m-e\/m.2z170-arh110m-k_xsinumerik_pcu50.5-pb250-s_firmwareprime_z270-asimotion_p320-4s_firmwareprime_b250-plusprime_h270-plussimatic_ipc847d_firmwareh170m-plus\/br_firmwarez170_pro_gamingsimatic_ipc827c_firmwareActive Management Technology
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-33627
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.2||HIGH
EPSS-0.15% / 35.99%
||
7 Day CHG~0.00%
Published-03 Feb, 2022 | 01:30
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.09.11, 5.1 before 05.17.11, 5.2 before 05.27.11, 5.3 before 05.36.11, 5.4 before 05.44.11, and 5.5 before 05.52.11 affecting FwBlockServiceSmm. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.

Action-Not Available
Vendor-n/aInsyde Software Corp. (ISC)Siemens AG
Product-simatic_ipc127e_firmwaresimatic_ipc477e_firmwaresimatic_ipc427e_firmwaresimatic_ipc847esimatic_ipc377gsimatic_ipc427esimatic_field_pg_m6insydeh2osimatic_ipc227gsimatic_ipc677esimatic_field_pg_m5_firmwaresimatic_ipc677e_firmwaresimatic_ipc277g_firmwaresimatic_ipc227g_firmwaresimatic_ipc127esimatic_ipc647e_firmwaresimatic_ipc277gsimatic_itp1000_firmwaresimatic_ipc627e_firmwaresimatic_ipc477esimatic_field_pg_m6_firmwaresimatic_ipc627esimatic_ipc847e_firmwaresimatic_ipc647esimatic_field_pg_m5simatic_itp1000simatic_ipc327gsimatic_ipc377g_firmwaresimatic_ipc327g_firmwaren/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-31894
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.03% / 6.35%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:02
Updated-03 Aug, 2024 | 23:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions < V9.1 SP2), SIMATIC PDM (All versions < V9.2 SP2), SIMATIC STEP 7 V5.X (All versions < V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 SP2 HF1). A directory containing metafiles relevant to devices' configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software.

Action-Not Available
Vendor-Siemens AG
Product-simatic_step_7simatic_pdmsimatic_pcs_7sinamics_startersimatic_pcs_7_firmwaresimatic_step_7_firmwaresinamics_starter_firmwaresimatic_pdm_firmwareSIMATIC STEP 7 V5.XSIMATIC PCS 7 V9.XSIMATIC PCS 7 V8.2 and earlierSINAMICS STARTER (containing STEP 7 OEM version)SIMATIC PDM
CWE ID-CWE-732
Incorrect Permission Assignment for Critical Resource
CVE-2021-31338
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.05% / 15.47%
||
7 Day CHG~0.00%
Published-19 Aug, 2021 | 10:00
Updated-03 Aug, 2024 | 22:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.0 SP1). Affected devices allow to modify configuration settings over an unauthenticated channel. This could allow a local attacker to escalate privileges and execute own code on the device.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connectSINEMA Remote Connect Client
CWE ID-CWE-15
External Control of System or Configuration Setting
CVE-2021-31893
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.13% / 33.60%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:02
Updated-03 Aug, 2024 | 23:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). The affected software contains a buffer overflow vulnerability while handling certain files that could allow a local attacker to trigger a denial-of-service condition or potentially lead to remote code execution.

Action-Not Available
Vendor-Siemens AG
Product-simatic_pcs_firmwaresimatic_step_7simatic_pdmsinamics_startersimatic_step_7_firmwaresimatic_pcssinamics_starter_firmwaresimatic_pdm_firmwareSIMATIC STEP 7 V5.XSIMATIC PCS 7 V8.2 and earlierSINAMICS STARTER (containing STEP 7 OEM version)SIMATIC PCS 7 V9.0SIMATIC PDM
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2010-2772
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.08% / 24.02%
||
7 Day CHG-0.01%
Published-22 Jul, 2010 | 10:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.

Action-Not Available
Vendor-n/aSiemens AG
Product-simatic_winccsimatic_pcs_7n/a
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2016-8566
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.11% / 30.57%
||
7 Day CHG~0.00%
Published-13 Feb, 2017 | 21:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Siemens SICAM PAS before 8.00. Because of Storing Passwords in a Recoverable Format, an authenticated local attacker with certain privileges could possibly reconstruct the passwords of users for accessing the database.

Action-Not Available
Vendor-n/aSiemens AG
Product-sicam_pas\/pqsSiemens SICAM PAS before 8.00
CVE-2016-6486
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.07% / 22.05%
||
7 Day CHG~0.00%
Published-08 Aug, 2016 | 00:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Siemens SINEMA Server uses weak permissions for the application folder, which allows local users to gain privileges via unspecified vectors.

Action-Not Available
Vendor-n/aSiemens AG
Product-sinema_servern/a
CVE-2022-24287
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 17.81%
||
7 Day CHG~0.00%
Published-10 May, 2022 | 09:46
Updated-21 Apr, 2025 | 13:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC06), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 and earlier (All versions), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Upd4), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 21), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 8). A missing printer configuration on the host could allow an authenticated attacker to escape the WinCC Kiosk Mode.

Action-Not Available
Vendor-Siemens AG
Product-simatic_winccsimatic_pcs_7simatic_wincc_runtime_professionalSIMATIC PCS 7 V9.0SIMATIC WinCC Runtime Professional V17SIMATIC WinCC V7.4SIMATIC WinCC V7.5SIMATIC PCS 7 V8.2SIMATIC WinCC V7.3SIMATIC PCS 7 V9.1SIMATIC WinCC Runtime Professional V16 and earlier
CWE ID-CWE-1188
Initialization of a Resource with an Insecure Default
CVE-2022-23448
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.03% / 5.73%
||
7 Day CHG~0.00%
Published-12 Apr, 2022 | 09:07
Updated-03 Aug, 2024 | 03:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.

Action-Not Available
Vendor-Siemens AG
Product-simatic_energy_manager_prosimatic_energy_manager_basicSIMATIC Energy Manager BasicSIMATIC Energy Manager PRO
CWE ID-CWE-732
Incorrect Permission Assignment for Critical Resource
CVE-2022-30527
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.08% / 24.26%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:20
Updated-27 Feb, 2025 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V2.0). The affected application assigns improper access rights to specific folders containing executable files and libraries. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-732
Incorrect Permission Assignment for Critical Resource
CVE-2019-18309
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.09% / 27.27%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with local access to the MS3000 Server and a low privileged user account could gain root privileges by manipulating specific files in the local file system. This vulnerability is independent from CVE-2019-18308. Please note that an attacker needs to have local access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-284
Improper Access Control
CVE-2022-0847
Matching Score-8
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-8
Assigner-Red Hat, Inc.
CVSS Score-7.8||HIGH
EPSS-84.35% / 99.27%
||
7 Day CHG~0.00%
Published-07 Mar, 2022 | 00:00
Updated-30 Jul, 2025 | 19:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-05-16||Apply updates per vendor instructions.

A flaw was found in the way the "flags" member of the new pipe buffer structure was lacking proper initialization in copy_page_to_iter_pipe and push_pipe functions in the Linux kernel and could thus contain stale values. An unprivileged local user could use this flaw to write to pages in the page cache backed by read only files and as such escalate their privileges on the system.

Action-Not Available
Vendor-ovirtn/aSiemens AGNetApp, Inc.Linux Kernel Organization, IncSonicWall Inc.Fedora ProjectRed Hat, Inc.
Product-h300s_firmwareenterprise_linux_for_power_little_endianfedorah700eh410ch500s_firmwareh700senterprise_linux_server_aush300e_firmwareh500sh500eenterprise_linux_for_ibm_z_systemsenterprise_linux_for_real_time_for_nfvh500e_firmwareenterprise_linux_for_real_time_tussma1000_firmwarescalance_lpe9403enterprise_linux_for_ibm_z_systems_eusenterprise_linux_server_update_services_for_sap_solutionsenterprise_linux_for_real_time_for_nfv_tussma1000h300sh300eh410s_firmwareenterprise_linux_eusenterprise_linux_server_tusscalance_lpe9403_firmwareenterprise_linux_for_power_little_endian_eush410sh410c_firmwareenterprise_linuxcodeready_linux_builderh700e_firmwareenterprise_linux_server_for_power_little_endian_update_services_for_sap_solutionsenterprise_linux_for_real_timeovirt-enginevirtualization_hostlinux_kernelh700s_firmwarekernelKernel
CWE ID-CWE-665
Improper Initialization
CVE-2020-8744
Matching Score-8
Assigner-Intel Corporation
ShareView Details
Matching Score-8
Assigner-Intel Corporation
CVSS Score-7.8||HIGH
EPSS-0.16% / 37.04%
||
7 Day CHG-0.01%
Published-12 Nov, 2020 | 18:06
Updated-04 Aug, 2024 | 10:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper initialization in subsystem for Intel(R) CSME versions before12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25, Intel(R) TXE versions before 4.0.30 Intel(R) SPS versions before E3_05.01.04.200 may allow a privileged user to potentially enable escalation of privilege via local access.

Action-Not Available
Vendor-n/aIntel CorporationSiemens AG
Product-server_platform_servicessimatic_s7-1518f-4_pn\/dp_mfp_firmwaretrusted_execution_enginesimatic_s7-1518-4_pn\/dp_mfpconverged_security_and_management_enginesimatic_s7-1518f-4_pn\/dp_mfpsimatic_s7-1500_firmwaresimatic_s7-1518-4_pn\/dp_mfp_firmwaresimatic_s7-1500Intel(R) CSME versions, Intel(R) TXE, Intel(R) SPS
CWE ID-CWE-665
Improper Initialization
CVE-2020-8177
Matching Score-8
Assigner-HackerOne
ShareView Details
Matching Score-8
Assigner-HackerOne
CVSS Score-7.8||HIGH
EPSS-0.03% / 6.02%
||
7 Day CHG~0.00%
Published-14 Dec, 2020 | 19:42
Updated-04 Aug, 2024 | 09:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

curl 7.20.0 through 7.70.0 is vulnerable to improper restriction of names for files and other resources that can lead too overwriting a local file when the -J flag is used.

Action-Not Available
Vendor-n/aCURLDebian GNU/LinuxSplunk LLC (Cisco Systems, Inc.)Siemens AGFujitsu Limited
Product-m12-1m10-4s_firmwareuniversal_forwarderm10-4curlm12-1_firmwarem10-4sm10-4_firmwaresinec_infrastructure_network_servicesm12-2sdebian_linuxm10-1_firmwarem10-1m12-2s_firmwarem12-2_firmwarem12-2https://github.com/curl/curl
CWE ID-CWE-99
Improper Control of Resource Identifiers ('Resource Injection')
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2020-7585
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.09% / 25.92%
||
7 Day CHG~0.00%
Published-10 Jun, 2020 | 16:23
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information.

Action-Not Available
Vendor-Siemens AG
Product-simatic_step_7simatic_pcs_7sinamics_startersimatic_process_device_managerSIMATIC STEP 7 V5.XSIMATIC PCS 7 V8.2 and earlierSINAMICS STARTER (containing STEP 7 OEM version)SIMATIC PCS 7 V9.0SIMATIC PDM
CWE ID-CWE-427
Uncontrolled Search Path Element
CVE-2020-7580
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.7||MEDIUM
EPSS-0.05% / 14.56%
||
7 Day CHG~0.00%
Published-10 Jun, 2020 | 00:00
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.

Action-Not Available
Vendor-Siemens AG
Product-simatic_step_7sinumerik_one_virtualsimatic_pcs_neosimatic_s7-1500_software_controllersimatic_winccsinamics_startdrivesimatic_wincc_open_architecturesimatic_net_pcsinema_serversimatic_wincc_runtime_professionalsimatic_pcs_7sinec_network_management_systemsimatic_automatic_toolsimatic_prosavesinamics_starter_commissioning_toolsinumerik_operatesimatic_wincc_runtime_advancedSIMATIC NET PC Software V14SIMATIC WinCC Runtime AdvancedSIMATIC NET PC Software V15SIMATIC STEP 7 (TIA Portal) V13SIMATIC Automation ToolSIMATIC WinCC Runtime Professional V15SIMATIC WinCC V7.4SIMATIC WinCC V7.5SIMATIC WinCC Runtime Professional V14SINUMERIK ONE virtualSIMATIC STEP 7 (TIA Portal) V16SIMATIC STEP 7 (TIA Portal) V15SIMATIC PCS neoSIMATIC WinCC Runtime Professional V13SINEMA ServerSINUMERIK OperateSINEC NMSSIMATIC S7-1500 Software ControllerSIMATIC WinCC OA V3.17SIMATIC ProSaveSIMATIC NET PC Software V16SIMATIC WinCC OA V3.16SIMATIC STEP 7 V5SIMATIC WinCC Runtime Professional V16SINAMICS STARTERSINAMICS StartdriveSIMATIC STEP 7 (TIA Portal) V14
CWE ID-CWE-428
Unquoted Search Path or Element
CVE-2020-7581
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.7||MEDIUM
EPSS-0.05% / 14.25%
||
7 Day CHG~0.00%
Published-14 Jul, 2020 | 13:18
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.

Action-Not Available
Vendor-Siemens AG
Product-simatic_notifier_serversimatic_step_7opcenter_intelligencesimatic_pcs_neoopcenter_execution_processsoft_starter_esopcenter_qualitysimocode_esopcenter_rd\&lopcenter_execution_discreteopcenter_execution_foundationSIMATIC Notifier Server for WindowsOpcenter Execution DiscreteSoft Starter ES V16Opcenter RD&LSoft Starter ES V15.1Opcenter Execution FoundationSIMATIC STEP 7 (TIA Portal) V16SIMOCODE ES V16Opcenter Execution ProcessSIMOCODE ES V15.1Opcenter QualityOpcenter IntelligenceSIMATIC STEP 7 (TIA Portal) V15SIMATIC PCS neo
CWE ID-CWE-428
Unquoted Search Path or Element
CVE-2023-50236
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.02% / 4.23%
||
7 Day CHG~0.00%
Published-13 Feb, 2024 | 09:00
Updated-07 May, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Polarion ALM (All versions < V2404.0). The affected product is vulnerable due to weak file and folder permissions in the installation path. An attacker with local access could exploit this vulnerability to escalate privileges to NT AUTHORITY\SYSTEM.

Action-Not Available
Vendor-Siemens AG
Product-polarion_almPolarion ALM
CWE ID-CWE-276
Incorrect Default Permissions
CVE-2020-27001
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.18% / 39.63%
||
7 Day CHG~0.00%
Published-09 Feb, 2021 | 15:38
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.1.0.2), Teamcenter Visualization (All versions < V13.1.0.2). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12041)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-27339
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-6.7||MEDIUM
EPSS-0.05% / 14.59%
||
7 Day CHG~0.00%
Published-16 Jun, 2021 | 15:49
Updated-04 Aug, 2024 | 16:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5).

Action-Not Available
Vendor-n/aInsyde Software Corp. (ISC)Siemens AG
Product-simatic_ipc127e_firmwaresimatic_ipc377ginsydeh2osimatic_ipc677esimatic_ipc227g_firmwaresimatic_ipc647e_firmwaresimatic_ipc277gsimatic_ipc627e_firmwaresimatic_ipc477esimatic_field_pg_m6_firmwaresimatic_ipc627esimatic_ipc847e_firmwaresimatic_field_pg_m5simatic_itp1000simatic_ipc377g_firmwaresimatic_ipc327g_firmwaresimatic_ipc477e_firmwaresimatic_ipc427e_firmwaresimatic_ipc847esimatic_ipc427esimatic_field_pg_m6ruggedcom_apr1808simatic_ipc227gsimatic_ipc477e_prosimatic_field_pg_m5_firmwaresimatic_ipc677e_firmwaresimatic_ipc477e_pro_firmwaresimatic_ipc277g_firmwaresimatic_ipc127esimatic_itp1000_firmwareruggedcom_apr1808_firmwaresimatic_ipc647esimatic_ipc327gn/a
CWE ID-CWE-20
Improper Input Validation
CVE-2020-27006
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.12% / 31.03%
||
7 Day CHG~0.00%
Published-09 Feb, 2021 | 15:38
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of PCT files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12182)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-26999
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.11% / 30.77%
||
7 Day CHG~0.00%
Published-09 Feb, 2021 | 15:38
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.1.0.2), Teamcenter Visualization (All versions < V13.1.0.2). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information. (ZDI-CAN-12042)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-125
Out-of-bounds Read
CVE-2020-25238
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.12% / 31.12%
||
7 Day CHG~0.00%
Published-09 Feb, 2021 | 15:38
Updated-04 Aug, 2024 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in PCS neo (Administration Console) (All versions < V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system.

Action-Not Available
Vendor-Siemens AG
Product-simatic_process_control_system_neototally_integrated_automation_portalPCS neo (Administration Console)TIA Portal
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-427
Uncontrolled Search Path Element
CVE-2021-41838
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.2||HIGH
EPSS-0.06% / 17.73%
||
7 Day CHG~0.00%
Published-03 Feb, 2022 | 01:43
Updated-04 Aug, 2024 | 03:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check.

Action-Not Available
Vendor-n/aInsyde Software Corp. (ISC)Siemens AG
Product-simatic_ipc127e_firmwaresimatic_ipc477e_firmwaresimatic_ipc427e_firmwaresimatic_ipc847esimatic_ipc377gsimatic_ipc427esimatic_field_pg_m6insydeh2osimatic_ipc227gsimatic_ipc677esimatic_field_pg_m5_firmwaresimatic_ipc677e_firmwaresimatic_ipc277g_firmwaresimatic_ipc227g_firmwaresimatic_ipc127esimatic_ipc647e_firmwaresimatic_ipc277gsimatic_itp1000_firmwaresimatic_ipc627e_firmwaresimatic_ipc477esimatic_field_pg_m6_firmwaresimatic_ipc627esimatic_ipc847e_firmwaresimatic_ipc647esimatic_field_pg_m5simatic_itp1000simatic_ipc327gsimatic_ipc377g_firmwaresimatic_ipc327g_firmwaren/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2020-25245
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.04% / 10.20%
||
7 Day CHG~0.00%
Published-09 Feb, 2021 | 15:38
Updated-04 Aug, 2024 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in DIGSI 4 (All versions < V4.94 SP1 HF 1). Several folders in the %PATH% are writeable by normal users. As these folders are included in the search for dlls, an attacker could place dlls there with code executed by SYSTEM.

Action-Not Available
Vendor-Siemens AG
Product-digsi_4DIGSI 4
CWE ID-CWE-276
Incorrect Default Permissions
CVE-2021-42029
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.04% / 10.03%
||
7 Day CHG~0.00%
Published-12 Apr, 2022 | 09:07
Updated-04 Aug, 2024 | 03:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 5), SIMATIC STEP 7 (TIA Portal) V17 (All versions < V17 Update 2). An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server.

Action-Not Available
Vendor-Siemens AG
Product-simatic_s7-1500_cpu_1507ssimatic_s7-1500_cpu_1516t-3simatic_s7-1500_cpu_1511csimatic_s7-1500_cpu_1512sp-1simatic_s7-1500_cpusimatic_s7-1500_cpu_1518-4_pn\/dp_mfpsimatic_s7-1500_cpu_1510sp-1simatic_s7-1200_cpu_1212csimatic_s7-1500_cpu_1515t-2simatic_s7-1500_cpu_1512spf-1simatic_s7-1500_cpu_1518-4_pnsimatic_s7-1500_cpu_1513-1simatic_s7-1500_cpu_1517-3_pnsimatic_s7-1500_cpu_1510spsimatic_s7-1200_cpu_1217csimatic_s7-1500_cpu_1517f-3_pn\/dpsimatic_s7-1500_cpu_1513r-1simatic_s7-1200_cpu_1215_fcsimatic_s7-1500_cpu_1511-1simatic_s7-1500_cpu_1518-4_dpsimatic_s7-1500_cpu_1513-1_pnsimatic_s7-1500_cpu_1511-1_pnsimatic_step_7simatic_s7-1500_cpu_1518hf-4simatic_s7-1200_cpu_1215csimatic_s7-1500_cpu_1515r-2simatic_s7-1500_cpu_1513f-1simatic_s7-1500_cpu_1512csimatic_s7-1500_cpu_1516f-3_pn\/dpsimatic_s7-1500_cpu_1511c-1simatic_s7-1500_cpu_1517-3_pn\/dpsimatic_s7-1500_cpu_1517-3simatic_s7-1500_cpu_1517f-3simatic_s7-1500_cpu_1508s_fsimatic_s7-1200_cpusimatic_s7-1500_cpu_1513f-1_pnsimatic_s7-1500_cpu_1517-3_dpsimatic_s7-1200_cpu_1214csimatic_s7-1500_cpu_1516tf-3simatic_s7-1500_cpu_1511t-1simatic_s7-1500_cpu_1517tf-3simatic_s7-1500_cpu_1511f-1simatic_s7-1500_cpu_1515-2_pnsimatic_s7-1200_cpu_1214_fcsimatic_s7-1500_cpu_1515tf-2simatic_s7-1500_cpu_1511tf-1simatic_s7-1500_cpu_1515-2simatic_s7-1500_cpu_1518-4simatic_s7-1500_cpu_1518-4_pn\/dpsimatic_s7-1500_cpu_1516-3_pnsimatic_s7-1500_cpu_1516-3_dpsimatic_s7-1500_cpu_1508ssimatic_s7-1500_cpu_1516-3_pn\/dpsimatic_s7-1500_cpu_1516-3simatic_s7-1200_cpu_1214fcsimatic_s7-1500_cpu_1518f-4_pn\/dpsimatic_s7-1500_cpu_1515f-2simatic_s7-1500_cpu_1512c-1simatic_s7-1500_cpu_1511f-1_pnsimatic_s7-1500_cpu_1515f-2_pnsimatic_s7-1500_cpu_1507s_fsimatic_s7-1200_cpu_1211csimatic_s7-1500_cpu_1516f-3simatic_s7-1500_cpu_1518simatic_s7-1200_cpu_1215fcsimatic_s7-1500_cpu_1518f-4simatic_s7-1500_cpu_1516pro_fsimatic_s7-1200_cpu_1212fcsimatic_s7-1500_cpu_1516pro-2simatic_s7-1500_cpu_1518tf-4simatic_s7-1500_cpu_1518t-4SIMATIC STEP 7 (TIA Portal) V17SIMATIC STEP 7 (TIA Portal) V16SIMATIC STEP 7 (TIA Portal) V15
CWE ID-CWE-284
Improper Access Control
CVE-2021-42554
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.2||HIGH
EPSS-0.05% / 13.85%
||
7 Day CHG~0.00%
Published-03 Feb, 2022 | 01:40
Updated-04 Aug, 2024 | 03:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.

Action-Not Available
Vendor-n/aInsyde Software Corp. (ISC)Siemens AG
Product-simatic_ipc127e_firmwaresimatic_ipc477e_firmwaresimatic_ipc427e_firmwaresimatic_ipc847esimatic_ipc377gsimatic_ipc427esimatic_field_pg_m6insydeh2osimatic_ipc227gsimatic_ipc677esimatic_field_pg_m5_firmwaresimatic_ipc677e_firmwaresimatic_ipc277g_firmwaresimatic_ipc227g_firmwaresimatic_ipc127esimatic_ipc647e_firmwaresimatic_ipc277gsimatic_itp1000_firmwareruggedcom_ape1808simatic_ipc627e_firmwaresimatic_ipc477esimatic_field_pg_m6_firmwaresimatic_ipc627esimatic_ipc847e_firmwareruggedcom_ape1808_firmwaresimatic_field_pg_m5simatic_itp1000simatic_ipc647esimatic_ipc327gsimatic_ipc377g_firmwaresimatic_ipc327g_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-42059
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-6.7||MEDIUM
EPSS-0.07% / 20.77%
||
7 Day CHG~0.00%
Published-03 Feb, 2022 | 01:13
Updated-04 Aug, 2024 | 03:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.08.41, Kernel 5.1 before 05.16.41, Kernel 5.2 before 05.26.41, Kernel 5.3 before 05.35.41, and Kernel 5.4 before 05.42.20. A stack-based buffer overflow leads toarbitrary code execution in UEFI DisplayTypeDxe DXE driver.

Action-Not Available
Vendor-n/aInsyde Software Corp. (ISC)Siemens AG
Product-simatic_ipc127e_firmwaresimatic_ipc477e_firmwaresimatic_ipc427e_firmwaresimatic_ipc847esimatic_ipc377gsimatic_ipc427esimatic_field_pg_m6insydeh2osimatic_ipc227gsimatic_ipc677esimatic_field_pg_m5_firmwaresimatic_ipc677e_firmwaresimatic_ipc277g_firmwaresimatic_ipc227g_firmwaresimatic_ipc127esimatic_ipc647e_firmwaresimatic_ipc277gsimatic_itp1000_firmwaresimatic_ipc627e_firmwaresimatic_ipc477esimatic_field_pg_m6_firmwaresimatic_ipc627esimatic_ipc847e_firmwaresimatic_ipc647esimatic_field_pg_m5simatic_itp1000simatic_ipc327gsimatic_ipc377g_firmwaresimatic_ipc327g_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-41837
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.2||HIGH
EPSS-0.07% / 20.80%
||
7 Day CHG~0.00%
Published-03 Feb, 2022 | 01:23
Updated-04 Aug, 2024 | 03:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.

Action-Not Available
Vendor-n/aInsyde Software Corp. (ISC)Siemens AG
Product-simatic_ipc127e_firmwaresimatic_ipc477e_firmwaresimatic_ipc427e_firmwaresimatic_ipc847esimatic_ipc377gsimatic_ipc427esimatic_field_pg_m6insydeh2osimatic_ipc227gsimatic_ipc677esimatic_field_pg_m5_firmwaresimatic_ipc677e_firmwaresimatic_ipc277g_firmwaresimatic_ipc227g_firmwaresimatic_ipc127esimatic_ipc647e_firmwaresimatic_ipc277gsimatic_itp1000_firmwaresimatic_ipc627e_firmwaresimatic_ipc477esimatic_field_pg_m6_firmwaresimatic_ipc627esimatic_ipc847e_firmwaresimatic_ipc647esimatic_field_pg_m5simatic_itp1000simatic_ipc327gsimatic_ipc377g_firmwaresimatic_ipc327g_firmwaren/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2019-19278
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.8||MEDIUM
EPSS-0.08% / 24.70%
||
7 Day CHG~0.00%
Published-16 Jan, 2020 | 15:35
Updated-05 Aug, 2024 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 Drives MLFB 6SR32..-.....-.... MLFB 6SR4...-.....-.... MLFB 6SR5...-.....-.... With option A30 (HMIs 12 inches or larger) (All versions), SINAMICS PERFECT HARMONY GH180 Drives MLFB 6SR325.-.....-.... (High Availability) (All versions). The affected device contains a vulnerability that could allow an unauthenticated attacker to restore the affected device to a point where predefined application and operating system protection mechanisms are not in place. Successful exploitation requires physical access to the system, but no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentialiy, integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sinamics_perfect_harmony_gh180_firmwaresinamics_perfect_harmony_gh180SINAMICS PERFECT HARMONY GH180 Drives MLFB 6SR325.-.....-.... (High Availability)SINAMICS PERFECT HARMONY GH180 Drives MLFB 6SR32..-.....-.... MLFB 6SR4...-.....-.... MLFB 6SR5...-.....-.... With option A30 (HMIs 12 inches or larger)
CWE ID-CWE-693
Protection Mechanism Failure
CWE ID-CWE-362
Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')
CVE-2021-41544
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.03% / 7.50%
||
7 Day CHG~0.00%
Published-08 Aug, 2023 | 09:20
Updated-11 Oct, 2024 | 22:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Siemens Software Center (All versions < V3.0). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.

Action-Not Available
Vendor-Siemens AG
Product-software_centerSiemens Software Center
CWE ID-CWE-427
Uncontrolled Search Path Element
CVE-2021-40363
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.03% / 5.34%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:17
Updated-04 Aug, 2024 | 02:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V17 (All versions <= V17 Update 4), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system.

Action-Not Available
Vendor-Siemens AG
Product-simatic_winccsimatic_pcs_7SIMATIC WinCC V15 and earlierSIMATIC WinCC V17SIMATIC PCS 7 V9.1SIMATIC PCS 7 V9.0SIMATIC WinCC V7.4SIMATIC WinCC V7.5SIMATIC WinCC V16SIMATIC PCS 7 V8.2
CWE ID-CWE-538
Insertion of Sensitive Information into Externally-Accessible File or Directory
CWE ID-CWE-312
Cleartext Storage of Sensitive Information
CVE-2021-37207
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.03% / 7.96%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:32
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SENTRON powermanager V3 (All versions). The affected application assigns improper access rights to a specific folder containing configuration files. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.

Action-Not Available
Vendor-Siemens AG
Product-sentron_powermanager_3SENTRON powermanager V3
CWE ID-CWE-732
Incorrect Permission Assignment for Critical Resource
CVE-2021-4034
Matching Score-8
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-8
Assigner-Red Hat, Inc.
CVSS Score-7.8||HIGH
EPSS-86.50% / 99.37%
||
7 Day CHG-0.52%
Published-28 Jan, 2022 | 00:00
Updated-30 Jul, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-07-18||Apply updates per vendor instructions.

A local privilege escalation vulnerability was found on polkit's pkexec utility. The pkexec application is a setuid tool designed to allow unprivileged users to run commands as privileged users according predefined policies. The current version of pkexec doesn't handle the calling parameters count correctly and ends trying to execute environment variables as commands. An attacker can leverage this by crafting environment variables in such a way it'll induce pkexec to execute arbitrary code. When successfully executed the attack can cause a local privilege escalation given unprivileged users administrative rights on the target machine.

Action-Not Available
Vendor-polkit_projectstarwindsoftwaren/aSiemens AGSUSERed Hat, Inc.Oracle CorporationCanonical Ltd.
Product-enterprise_linux_eusenterprise_linux_serverstarwind_virtual_sanmanager_serverubuntu_linuxlinux_enterprise_desktopzfs_storage_appliance_kitenterprise_linux_for_ibm_z_systemslinux_enterprise_serverenterprise_linux_for_ibm_z_systems_euscommand_centerlinux_enterprise_workstation_extensionenterprise_linux_for_power_big_endianscalance_lpe9403scalance_lpe9403_firmwarelinux_enterprise_high_performance_computingenterprise_linux_workstationmanager_proxypolkitenterprise_storageenterprise_linux_for_scientific_computinghttp_serverenterprise_linux_desktopenterprise_linux_for_power_little_endianenterprise_linux_server_ausenterprise_linux_server_tusenterprise_linuxenterprise_linux_server_eusenterprise_linux_server_update_services_for_sap_solutionsenterprise_linux_for_power_little_endian_eussinumerik_edgepolkitPolkit
CWE ID-CWE-787
Out-of-bounds Write
CWE ID-CWE-125
Out-of-bounds Read
CVE-2025-40580
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.4||MEDIUM
EPSS-0.02% / 2.64%
||
7 Day CHG~0.00%
Published-13 May, 2025 | 09:39
Updated-08 Jul, 2025 | 11:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices are vulnerable to a stack-based buffer overflow. This could allow a non-privileged local attacker to execute arbitrary code on the device or to cause a denial of service condition.

Action-Not Available
Vendor-Siemens AG
Product-scalance_lpe9403scalance_lpe9403_firmwareSCALANCE LPE9403
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-40582
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.5||HIGH
EPSS-0.03% / 6.73%
||
7 Day CHG~0.00%
Published-13 May, 2025 | 09:39
Updated-30 May, 2025 | 17:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions with SINEMA Remote Connect Edge Client installed). Affected devices do not properly sanitize configuration parameters. This could allow a non-privileged local attacker to execute root commands on the device.

Action-Not Available
Vendor-Siemens AG
Product-scalance_lpe9403_firmwarescalance_lpe9403SCALANCE LPE9403
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-40574
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.5||HIGH
EPSS-0.01% / 1.81%
||
7 Day CHG~0.00%
Published-13 May, 2025 | 09:38
Updated-08 Jul, 2025 | 11:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly assign permissions to critical ressources. This could allow a non-privileged local attacker to interact with the backupmanager service.

Action-Not Available
Vendor-Siemens AG
Product-scalance_lpe9403scalance_lpe9403_firmwareSCALANCE LPE9403
CWE ID-CWE-732
Incorrect Permission Assignment for Critical Resource
CVE-2025-40751
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-4.8||MEDIUM
EPSS-0.01% / 1.32%
||
7 Day CHG~0.00%
Published-12 Aug, 2025 | 11:17
Updated-20 Aug, 2025 | 20:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V3.3). Affected SIMATIC RTLS Locating Manager Report Clients do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role.

Action-Not Available
Vendor-Siemens AG
Product-simatic_rtls_locating_managerSIMATIC RTLS Locating Manager
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2025-40768
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7||HIGH
EPSS-0.01% / 1.59%
||
7 Day CHG~0.00%
Published-12 Aug, 2025 | 11:17
Updated-15 Aug, 2025 | 18:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V3.0). The affected application exposes an internal service port to be accessible from outside the system. This could allow an unauthorized attacker to access the application.

Action-Not Available
Vendor-Siemens AG
Product-sinec_traffic_analyzerSINEC Traffic Analyzer
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2025-40579
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.4||MEDIUM
EPSS-0.02% / 2.64%
||
7 Day CHG~0.00%
Published-13 May, 2025 | 09:39
Updated-08 Jul, 2025 | 11:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices are vulnerable to a stack-based buffer overflow. This could allow a non-privileged local attacker to execute arbitrary code on the device or to cause a denial of service condition.

Action-Not Available
Vendor-Siemens AG
Product-scalance_lpe9403scalance_lpe9403_firmwareSCALANCE LPE9403
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-40767
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.01% / 1.78%
||
7 Day CHG~0.00%
Published-12 Aug, 2025 | 11:17
Updated-15 Aug, 2025 | 18:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V3.0). The affected application runs docker containers without adequate security controls to enforce isolation. This could allow an attacker to gain elevated access, potentially accessing sensitive host system resources.

Action-Not Available
Vendor-Siemens AG
Product-sinec_traffic_analyzerSINEC Traffic Analyzer
CWE ID-CWE-250
Execution with Unnecessary Privileges
CVE-2020-12360
Matching Score-8
Assigner-Intel Corporation
ShareView Details
Matching Score-8
Assigner-Intel Corporation
CVSS Score-7.8||HIGH
EPSS-0.17% / 39.19%
||
7 Day CHG~0.00%
Published-09 Jun, 2021 | 18:53
Updated-04 Aug, 2024 | 11:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Out of bounds read in the firmware for some Intel(R) Processors may allow an authenticated user to potentially enable escalation of privilege via local access.

Action-Not Available
Vendor-n/aNetApp, Inc.Intel CorporationSiemens AG
Product-xeon_platinum_8153xeon_e3-1230_v5xeon_e3-1558l_v5xeon_w-3245mxeon_e5-4610_v4xeon_e7-8894_v4xeon_gold_6146xeon_e5-2660_v3core_i7-1068ng7e-series_bioscore_i7-1160g7xeon_e5-1680_v3xeon_d-1527xeon_e5-2697_v4xeon_gold_5115xeon_platinum_8170xeon_gold_6136xeon_w-2125core_i9-10940xxeon_e5-4610_v3xeon_e5-4650_v4xeon_e7-8880_v4xeon_gold_6138xeon_e5-1660_v4simatic_ipc547g_firmwarexeon_e7-8891_v4xeon_platinum_8164xeon_e-2226gxeon_e3-1280_v5xeon_gold_6234xeon_e5-2699r_v4xeon_w-2255xeon_d-1518core_i7-11700core_i7-6822eqcore_i7-6700texeon_e3-1501l_v6xeon_gold_6262vcore_i7-11370hxeon_e5-2683_v4xeon_platinum_8168core_i7-7600uxeon_e5-2608l_v4xeon_e5-2640_v3xeon_e-2224xeon_gold_5218xeon_e5-1620_v4core_i7-11850hxeon_d-1567simatic_cpu_1518f-4_firmwarexeon_e5-2630l_v3xeon_e3-1505l_v6xeon_e-2278gexeon_e5-1607_v3xeon_e5-4640_v4xeon_gold_5117xeon_gold_5122xeon_w-2245xeon_d-1587xeon_e5-2699_v3xeon_d-2191xeon_gold_6248rcore_i7-7820hkxeon_e5-2689_v4xeon_e7-8870_v4xeon_w-1290tcore_i5-l16g7xeon_gold_6240core_i7-6970hqxeon_gold_6262xeon_platinum_8156xeon_e-2136core_i7-10510ucore_i7-1060g7xeon_w-2265xeon_e5-2667_v4xeon_platinum_8274xeon_w-10855mxeon_gold_6126fxeon_d-1539xeon_e3-1535m_v5xeon_e5-1680_v4core_i7-7700xeon_gold_5220rxeon_d-2146ntxeon_e3-1268l_v5xeon_platinum_8160fxeon_e5-2658_v3xeon_e5-4660_v4core_i7-8750hxeon_e3-1501m_v6xeon_gold_6250lxeon_gold_6210uxeon_d-2187ntxeon_platinum_8160mcore_i7-10700fxeon_d-2166ntxeon_e3-1270_v6xeon_e-2286mxeon_e3-1505m_v5core_i7-10750hxeon_silver_4216xeon_gold_6230xeon_platinum_8253xeon_e5-2630l_v4xeon_w-2195xeon_e5-4667_v4xeon_e5-2628l_v4xeon_e-2276gxeon_e5-2685_v3xeon_w-1390xeon_e-2186gxeon_d-2183itxeon_silver_4116txeon_e-2174gxeon_e5-2630_v4xeon_d-1622core_i7-8809gxeon_e5-4667_v3xeon_platinum_8160hcore_i7-8700bxeon_e5-2643_v3xeon_d-2145ntxeon_d-1581xeon_e5-1650_v4xeon_gold_6238xeon_e5-2630_v3xeon_w-1250pxeon_silver_4208xeon_e3-1585_v5xeon_w-2104xeon_e5-2623_v4core_i7-6560uxeon_w-2123xeon_gold_5220sxeon_w-3275mxeon_platinum_9282xeon_e5-2683_v3core_i7-10700exeon_silver_4108xeon_gold_6130txeon_silver_4210core_i7-11700kfcloud_backupcore_i7-10870hxeon_e7-8867_v4xeon_bronze_3106xeon_w-2102xeon_e-2274gcore_i7-10700kxeon_e-2278gelxeon_d-1540xeon_e3-1280_v6hci_compute_node_biosxeon_e5-2698_v4xeon_platinum_8160tcore_i7-11700kxeon_d-1528xeon_silver_4214rcore_i7-6500uxeon_e5-2697_v3xeon_e5-4627_v4xeon_e-2124core_i7-10710uxeon_d-2141icore_i7-10700kfxeon_d-1541xeon_e5-2660_v4xeon_e7-4830_v4xeon_w-1250texeon_platinum_8268xeon_platinum_8176mxeon_e-2276mecore_i7-8565uxeon_gold_5222xeon_e5-2687w_v4xeon_e5-1603_v3core_i7-7560uxeon_gold_5117fxeon_e3-1535m_v6xeon_d-1548xeon_d-1649nxeon_d-1529xeon_platinum_9221xeon_e3-1220_v5xeon_platinum_8160xeon_e5-2428l_v3core_i7-6700hqxeon_e7-4809_v4xeon_e5-4648_v3xeon_gold_6122xeon_silver_4123xeon_gold_6148fxeon_gold_6132biosxeon_e5-2618l_v4xeon_w-2155xeon_gold_6137core_i7-7500ucore_i7-8550uxeon_e-2224gxeon_w-2135xeon_d-1623nxeon_w-2145xeon_e-2226gecore_i7-6650uxeon_gold_6142core_i7-10610ucore_i7-8500ycore_i7-7567uxeon_silver_4214xeon_w-1390pxeon_d-2161ixeon_silver_4210rxeon_d-1632core_i7-7820hqxeon_e3-1585l_v5xeon_e5-2620_v3xeon_e5-2670_v3xeon_gold_5218bxeon_e5-2648l_v3xeon_gold_6142mxeon_e5-2609_v3xeon_e3-1275_v5xeon_e5-2438l_v3xeon_e3-1240_v5xeon_e5-2650_v3xeon_gold_6222core_i7-6567uxeon_e5-2648l_v4xeon_e5-4620_v4xeon_e7-8855_v4xeon_d-1513nxeon_d-1537xeon_e3-1515m_v5xeon_w-1290texeon_e3-1225_v5xeon_gold_6209uxeon_silver_4112xeon_d-1559xeon_w-3223xeon_gold_5120txeon_w-3175xxeon_gold_6134xeon_gold_6162xeon_e5-2628l_v3xeon_e-2254mexeon_w-3235core_i7-7y75xeon_e5-4669_v3xeon_w-2225xeon_gold_6130hxeon_w-2133core_i7-6700xeon_d-1557xeon_e5-4627_v3xeon_e7-4850_v4xeon_gold_6148xeon_e3-1505m_v6xeon_gold_6144xeon_gold_6140msimatic_cpu_1518f-4xeon_gold_5220txeon_platinum_8276lxeon_w-2223xeon_e5-2679_v4core_i7-7700kcore_i7-8705gxeon_e-2276mcore_i7-8665uxeon_gold_6129xeon_platinum_9222xeon_gold_6230tcore_i7-7660ucore_i7-6600ucore_i7-8706gxeon_gold_6126tcore_i7-11700fxeon_platinum_8165xeon_w-3225xeon_gold_6135xeon_e3-1565l_v5xeon_e-2236xeon_w-1370core_i7-10850hxeon_e5-1603_v4core_i7-1185grexeon_e5-2408l_v3core_i7-11375hxeon_e3-1240_v6xeon_d-1573ncore_i7-8700core_i7-7700tcore_i7-10700txeon_e5-1630_v4xeon_e5-4660_v3xeon_gold_6246core_i7-8086kxeon_w-2295core_i7-6770hqcore_i7-8700kxeon_e5-2603_v3fas_biosxeon_e-2134xeon_e5-2667_v3xeon_gold_5215xeon_e5-4655_v3xeon_d-2143itxeon_d-2163itxeon_e5-2699_v4xeon_e3-1285_v6xeon_w-1390tsimatic_cpu_1518-4xeon_w-1270xeon_e3-1225_v6xeon_platinum_8284xeon_silver_4109tcore_i7-10510yxeon_e3-1240l_v5xeon_e5-2690_v3xeon_e5-4655_v4xeon_gold_5215lxeon_silver_4215rxeon_e5-2658_v4xeon_gold_6138fcore_i7-11800hxeon_e5-1630_v3xeon_silver_4210txeon_e5-2680_v3xeon_gold_6212uxeon_e3-1205_v6core_i7-7700hqxeon_w-1270texeon_silver_4114xeon_e5-2698_v3core_i7-6498duxeon_e3-1245_v5core_i7-6870hqxeon_gold_6258rxeon_bronze_3104xeon_d-1571xeon_gold_6240lxeon_gold_6238lxeon_e5-2637_v3xeon_e5-1620_v3xeon_gold_6250xeon_d-2173itcore_i7-11700txeon_w-11855mxeon_d-2123itxeon_gold_5219yxeon_e-2246gxeon_w-3265mxeon_d-1627xeon_e5-2637_v4xeon_e5-2687w_v3xeon_d-1602xeon_e7-8890_v4xeon_e5-2680_v4xeon_gold_5218txeon_e5-2697a_v4xeon_gold_6150xeon_gold_6140xeon_e5-2690_v4xeon_e5-2609_v4core_i7-7920hqxeon_platinum_8174xeon_d-1612xeon_e-2254mlxeon_e3-1545m_v5core_i7-10700core_i9-10920xxeon_e3-1578l_v5core_i7-6660uxeon_e3-1270_v5xeon_gold_6126xeon_e3-1260l_v5xeon_w-1250exeon_e5-2643_v4xeon_d-1563nxeon_e5-2699a_v4simatic_cpu_1518-4_firmwarecore_i7-10875hxeon_e-2276mlxeon_e-2244gxeon_e-2176gxeon_gold_6142fcore_i3-l13g4core_i7-8709gxeon_e5-4650_v3xeon_e5-2650l_v4xeon_gold_6130xeon_e-2104gxeon_platinum_8260core_i7-8557usimatic_ipc547gcore_i7-8700txeon_platinum_9242core_i7-6820hqxeon_platinum_8280lxeon_silver_4110core_i7-8650uxeon_bronze_3204xeon_gold_5119tcore_i7-1180g7core_i7-6700tcore_i7-6920hqxeon_gold_6246rxeon_e3-1230_v6xeon_gold_5217xeon_gold_6230nxeon_gold_6143xeon_w-3265xeon_gold_5218nxeon_e5-2620_v4xeon_gold_6138txeon_w-3245xeon_gold_5120core_i7-1185g7core_i7-1195g7xeon_e-2124gcore_i7-1165g7xeon_e5-2618l_v3xeon_d-1523nxeon_e5-2608l_v3core_i7-10700texeon_e-2288gxeon_d-1653nxeon_gold_5220xeon_e-2234xeon_d-1577xeon_d-1637xeon_gold_6254xeon_gold_6269yxeon_silver_4114tcore_i7-6700kxeon_gold_6240yxeon_e5-4669_v4aff_biosxeon_gold_6154xeon_w-1250xeon_e5-2640_v4hci_storage_node_biosxeon_gold_6208uxeon_e7-8893_v4xeon_w-1290exeon_e5-1650_v3xeon_w-3275core_i7-11700bxeon_d-1553nxeon_e-2126gxeon_silver_4209txeon_e5-4620_v3xeon_silver_4116xeon_w-1270exeon_d-1633ncore_i7-7820eqxeon_gold_6252nxeon_e7-4820_v4xeon_gold_6244xeon_e5-2695_v3xeon_gold_6248xeon_e3-1220_v6xeon_w-1370pxeon_platinum_8280xeon_e-2186mxeon_e5-1660_v3xeon_d-1520xeon_e-2176mcore_i7-6785rcore_i7-6820hkxeon_platinum_8256xeon_gold_6152core_i7-1060ng7xeon_e5-2623_v3xeon_platinum_8158xeon_e5-2658a_v3xeon_e5-2418l_v3xeon_w-1290pxeon_e-2286gxeon_gold_6222vxeon_platinum_8176xeon_gold_6242xeon_e3-1275_v6xeon_d-1531core_i7-10810uxeon_e3-1575m_v5xeon_e-2278gxeon_e5-2650_v4xeon_platinum_8260yxeon_e3-1505l_v5xeon_platinum_8270xeon_d-1533nxeon_gold_6242rxeon_e3-1245_v6xeon_gold_6128xeon_silver_4215xeon_d-2142itxeon_platinum_8180mcore_i7-8850hxeon_gold_5118xeon_w-2235xeon_e5-2695_v4xeon_gold_6130fxeon_w-11955mcore_i7-6820eqxeon_gold_6134mcore_i9-10900xxeon_platinum_8276xeon_gold_6238txeon_e3-1235l_v5xeon_silver_4214yxeon_e5-2603_v4core_i9-10980xexeon_e5-4628l_v4xeon_e7-8860_v4xeon_w-1350xeon_silver_4106hxeon_gold_6138pcore_i7-8665uexeon_w-1290xeon_platinum_8176fxeon_d-1524nsolidfire_biosxeon_gold_6240rxeon_w-10885mxeon_w-2275xeon_d-1543nxeon_gold_6226xeon_e-2144gxeon_gold_6256xeon_d-1521xeon_w-1350pxeon_gold_6230rcore_i7-8569uxeon_gold_6252xeon_e5-4640_v3core_i7-1185g7exeon_gold_5218rxeon_gold_6226rxeon_bronze_3206rxeon_e5-1607_v4core_i7-1065g7xeon_platinum_8260lxeon_e5-1428l_v3core_i7-8559uxeon_platinum_8170mxeon_e-2146gxeon_platinum_8180xeon_d-2177ntxeon_e5-2650l_v3xeon_w-2175Intel(R) Processors
CWE ID-CWE-125
Out-of-bounds Read
CVE-2020-0590
Matching Score-8
Assigner-Intel Corporation
ShareView Details
Matching Score-8
Assigner-Intel Corporation
CVSS Score-7.8||HIGH
EPSS-0.36% / 57.63%
||
7 Day CHG~0.00%
Published-12 Nov, 2020 | 17:54
Updated-04 Aug, 2024 | 06:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper input validation in BIOS firmware for some Intel(R) Processors may allow an authenticated user to potentially enable escalation of privilege via local access.

Action-Not Available
Vendor-n/aNetApp, Inc.Intel CorporationSiemens AG
Product-xeon_platinum_8276lxeon_platinum_8153xeon_silver_4210r_firmwarexeon_platinum_8170_firmwarexeon_platinum_9222xeon_bronze_3104_firmwarexeon_gold_6230txeon_gold_6146xeon_gold_6126f_firmwarexeon_gold_6126txeon_gold_6140_firmwarexeon_platinum_8168_firmwarexeon_silver_4108_firmwarexeon_gold_5115xeon_gold_6238_firmwarexeon_platinum_8170xeon_gold_6136xeon_gold_6138f_firmwarexeon_gold_5217_firmwarexeon_gold_6138xeon_gold_6246simatic_ipc547g_firmwarexeon_platinum_8164xeon_gold_6240_firmwarexeon_gold_6234xeon_silver_4116t_firmwarexeon_gold_6238rxeon_gold_5215xeon_platinum_8268_firmwarexeon_gold_6248_firmwarexeon_gold_6262vxeon_platinum_8168xeon_gold_6244_firmwarexeon_gold_5218xeon_silver_4109txeon_bronze_3206r_firmwarexeon_silver_4215rxeon_gold_5215lxeon_silver_4215_firmwarexeon_gold_5220r_firmwarexeon_gold_5122_firmwarexeon_gold_6138t_firmwarexeon_gold_6138fxeon_silver_4116_firmwarexeon_gold_5122xeon_platinum_8180_firmwarexeon_silver_4210_firmwarexeon_gold_6132_firmwarexeon_gold_6136_firmwarexeon_silver_4210txeon_gold_6212u_firmwarexeon_gold_6212uxeon_gold_6126_firmwarexeon_gold_6240l_firmwarexeon_silver_4114xeon_gold_6248rxeon_gold_6250l_firmwarexeon_silver_4214r_firmwarexeon_platinum_8276_firmwarexeon_gold_6258rxeon_bronze_3104xeon_gold_6240xeon_gold_6238lxeon_gold_6240lxeon_gold_6150_firmwarexeon_gold_6250xeon_platinum_8156xeon_bronze_3106_firmwarexeon_gold_6138_firmwarexeon_gold_5218n_firmwarexeon_gold_5215_firmwarexeon_gold_5220s_firmwaresimatic_ipc527gxeon_platinum_8260y_firmwarexeon_gold_6144_firmwarexeon_gold_6126fxeon_silver_4109t_firmwarexeon_gold_5218tsimatic_ipc847e_firmwarexeon_gold_6240y_firmwaresimatic_ipc527g_firmwarexeon_gold_6150xeon_gold_6242_firmwarexeon_gold_5220rxeon_gold_6140xeon_silver_4114_firmwarexeon_gold_6230_firmwarexeon_platinum_8280l_firmwarexeon_platinum_8160fxeon_gold_6148f_firmwarexeon_gold_6250lxeon_gold_6210uxeon_gold_6126simatic_ipc647exeon_platinum_8158_firmwarexeon_gold_5120_firmwarexeon_silver_4216xeon_silver_4114t_firmwarexeon_gold_6230xeon_platinum_8253xeon_gold_6134_firmwarexeon_gold_6130t_firmwarexeon_gold_5218r_firmwarexeon_gold_6242r_firmwarexeon_gold_6130f_firmwarexeon_silver_4116tclustered_data_ontapxeon_gold_6246r_firmwarexeon_gold_6142fsimatic_ipc627exeon_gold_6238xeon_platinum_8153_firmwarexeon_gold_6126t_firmwarexeon_gold_6130xeon_silver_4214y_firmwarexeon_silver_4208xeon_platinum_8260xeon_platinum_8160t_firmwarexeon_bronze_3204_firmwarexeon_silver_4214_firmwarexeon_gold_5220ssimatic_ipc547gxeon_platinum_9242xeon_platinum_9282xeon_gold_5119t_firmwarexeon_platinum_8280lxeon_silver_4110xeon_gold_6142_firmwarexeon_bronze_3204xeon_platinum_9242_firmwarexeon_platinum_8280_firmwarexeon_gold_6240r_firmwarexeon_gold_5119txeon_silver_4108xeon_gold_6130txeon_silver_4210xeon_platinum_8256_firmwarexeon_gold_6246rcloud_backupxeon_gold_5217xeon_gold_6230nxeon_silver_4215r_firmwarexeon_gold_5218nxeon_gold_6246_firmwarexeon_gold_5222_firmwarexeon_bronze_3106xeon_gold_6138tsimatic_ipc647e_firmwarexeon_gold_6248r_firmwarexeon_platinum_9221_firmwarexeon_gold_6256_firmwarexeon_gold_5120simatic_ipc627e_firmwarexeon_gold_5220xeon_gold_6154_firmwarexeon_platinum_8160txeon_silver_4214rxeon_gold_6254xeon_silver_4209t_firmwarexeon_silver_4114txeon_gold_6240yxeon_platinum_8176_firmwarexeon_gold_6154xeon_gold_6230t_firmwarexeon_gold_5215l_firmwarexeon_silver_4208_firmwarexeon_gold_6208uxeon_platinum_8268xeon_gold_6252n_firmwarexeon_gold_5120t_firmwarexeon_gold_6230n_firmwarexeon_gold_5222xeon_platinum_8270_firmwarexeon_gold_6230r_firmwarexeon_silver_4209txeon_gold_6234_firmwarexeon_silver_4116xeon_gold_6210u_firmwarexeon_gold_6252nxeon_platinum_9221xeon_gold_6244xeon_platinum_8160xeon_gold_5218t_firmwarexeon_gold_6248xeon_gold_5115_firmwarexeon_platinum_8260l_firmwarexeon_gold_6226_firmwarexeon_platinum_8156_firmwaresimatic_ipc847exeon_gold_5118_firmwarexeon_platinum_8280xeon_gold_6152_firmwarexeon_gold_6146_firmwarexeon_platinum_8176f_firmwarexeon_gold_6148fxeon_gold_5218_firmwarexeon_gold_6132xeon_gold_6238t_firmwarexeon_platinum_8256xeon_gold_6152xeon_gold_6238l_firmwarexeon_platinum_8158xeon_gold_5218b_firmwarexeon_gold_6222vxeon_platinum_8176xeon_platinum_8160_firmwarexeon_gold_6242xeon_silver_4112_firmwarexeon_gold_6262v_firmwarexeon_gold_6142xeon_platinum_8260yxeon_platinum_8270xeon_gold_6242rxeon_gold_6148_firmwarexeon_silver_4215xeon_gold_6128xeon_platinum_9222_firmwarexeon_gold_5220t_firmwarexeon_platinum_8253_firmwarexeon_gold_5118xeon_silver_4210t_firmwarexeon_gold_6130fxeon_gold_5220_firmwarexeon_gold_6208u_firmwarexeon_silver_4214xeon_platinum_8276xeon_gold_6142f_firmwarexeon_gold_6250_firmwarexeon_gold_6238txeon_silver_4210rxeon_platinum_8164_firmwarexeon_silver_4214yxeon_gold_5218bxeon_silver_4216_firmwarexeon_gold_6138pxeon_gold_6254_firmwarexeon_gold_6138p_firmwarexeon_platinum_8176fxeon_gold_6240rsimatic_ipc677exeon_gold_6258r_firmwarexeon_gold_6209uxeon_silver_4112xeon_gold_6226xeon_gold_6256xeon_gold_6130_firmwarexeon_gold_6238r_firmwarexeon_gold_5120txeon_gold_6230rxeon_gold_6252xeon_gold_6134xeon_gold_6222v_firmwarexeon_platinum_8160f_firmwarexeon_gold_6226r_firmwarexeon_platinum_8260_firmwarexeon_gold_5218rxeon_gold_6226rxeon_bronze_3206rxeon_gold_6252_firmwaresimatic_ipc677e_firmwarexeon_gold_6148xeon_gold_6209u_firmwarexeon_silver_4110_firmwarefas\/aff_biosxeon_platinum_8260lxeon_gold_6144xeon_platinum_9282_firmwarexeon_platinum_8180xeon_platinum_8276l_firmwarexeon_gold_6128_firmwarexeon_gold_5220tIntel(R) Processors
CWE ID-CWE-20
Improper Input Validation
CVE-2020-10051
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.04% / 10.63%
||
7 Day CHG~0.00%
Published-09 Sep, 2020 | 18:09
Updated-04 Aug, 2024 | 10:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). Multiple services of the affected application are executed with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to inject arbitrary commands that are execeuted instead of the legitimate service.

Action-Not Available
Vendor-Siemens AG
Product-simatic_rtls_locating_managerSIMATIC RTLS Locating Manager
CWE ID-CWE-428
Unquoted Search Path or Element
Details not found