Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2022-26380

Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-12 Apr, 2022 | 09:07
Updated At-03 Aug, 2024 | 05:03
Rejected At-
Credits

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate if a certain SNMP key exists. An attacker could use this to trigger a reboot of an affected device by requesting specific SNMP information from the device.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:12 Apr, 2022 | 09:07
Updated At:03 Aug, 2024 | 05:03
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate if a certain SNMP key exists. An attacker could use this to trigger a reboot of an affected device by requesting specific SNMP information from the device.

Affected Products
Vendor
Siemens AGSiemens
Product
SCALANCE X302-7 EEC (230V)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X302-7 EEC (230V, coated)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X302-7 EEC (24V)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X302-7 EEC (24V, coated)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X302-7 EEC (2x 230V)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X302-7 EEC (2x 230V, coated)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X302-7 EEC (2x 24V)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X302-7 EEC (2x 24V, coated)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X304-2FE
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X306-1LD FE
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X307-2 EEC (230V)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X307-2 EEC (230V, coated)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X307-2 EEC (24V)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X307-2 EEC (24V, coated)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X307-2 EEC (2x 230V)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X307-2 EEC (2x 230V, coated)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X307-2 EEC (2x 24V)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X307-2 EEC (2x 24V, coated)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X307-3
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X307-3
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X307-3LD
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X307-3LD
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X308-2
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X308-2
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X308-2LD
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X308-2LD
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X308-2LH
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X308-2LH
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X308-2LH+
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X308-2LH+
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X308-2M
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X308-2M
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X308-2M PoE
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X308-2M PoE
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X308-2M TS
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X308-2M TS
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X310
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X310
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X310FE
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X310FE
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X320-1 FE
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X320-1-2LD FE
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE X408-2
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-12M (230V, ports on front)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-12M (230V, ports on front)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-12M (230V, ports on rear)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-12M (230V, ports on rear)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-12M (24V, ports on front)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-12M (24V, ports on front)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-12M (24V, ports on rear)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-12M (24V, ports on rear)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-12M TS (24V)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-12M TS (24V)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M EEC (24V, ports on front)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M EEC (24V, ports on front)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M EEC (24V, ports on rear)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M EEC (24V, ports on rear)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M EEC (2x 24V, ports on front)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M EEC (2x 24V, ports on front)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M EEC (2x 24V, ports on rear)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M EEC (2x 24V, ports on rear)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M PoE (230V, ports on front)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M PoE (230V, ports on rear)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M PoE (24V, ports on front)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M PoE (24V, ports on rear)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SCALANCE XR324-4M PoE TS (24V, ports on front)
Versions
Affected
  • All versions < V4.1.4
Vendor
Siemens AGSiemens
Product
SIPLUS NET SCALANCE X308-2
Versions
Affected
  • All versions < V4.1.4
Problem Types
TypeCWE IDDescription
CWECWE-125CWE-125: Out-of-bounds Read
Type: CWE
CWE ID: CWE-125
Description: CWE-125: Out-of-bounds Read
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf
x_refsource_MISC
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf
x_refsource_MISC
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:12 Apr, 2022 | 09:15
Updated At:19 Apr, 2022 | 18:15

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate if a certain SNMP key exists. An attacker could use this to trigger a reboot of an affected device by requesting specific SNMP information from the device.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.17.5HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Primary2.07.8HIGH
AV:N/AC:L/Au:N/C:N/I:N/A:C
Type: Primary
Version: 3.1
Base score: 7.5
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Type: Primary
Version: 2.0
Base score: 7.8
Base severity: HIGH
Vector:
AV:N/AC:L/Au:N/C:N/I:N/A:C
CPE Matches

Siemens AG
siemens
>>scalance_x302-7eec>>-
cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x302-7eec_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x304-2fe>>-
cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x304-2fe_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x306-1ldfe>>-
cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x306-1ldfe_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x307-2eec>>-
cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x307-2eec_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x307-3>>-
cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x307-3_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x307-3ld>>-
cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x307-3ld_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x308-2>>-
cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x308-2_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x308-2ld>>-
cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x308-2ld_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x308-2lh_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x308-2lh>>-
cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x308-2lh\+_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_x308-2lh\+_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x308-2lh\+>>-
cpe:2.3:h:siemens:scalance_x308-2lh\+:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x308-2m_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x308-2m>>-
cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x308-2m_poe_firmware>>-
cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x308-2m_poe>>-
cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x308-2m_ts_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x308-2m_ts>>-
cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x310_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x310>>-
cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x310fe_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x310fe>>-
cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x320-1fe_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x320-1fe>>-
cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x320-1-2ldfe_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_x320-1-2ldfe_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x320-1-2ldfe>>-
cpe:2.3:h:siemens:scalance_x320-1-2ldfe:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x408-2_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_x408-2_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x408-2>>-
cpe:2.3:h:siemens:scalance_x408-2:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_xr324-4m_eec_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_xr324-4m_eec>>-
cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_xr324-4m_poe_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_xr324-4m_poe>>-
cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_xr324-4m_poe_ts_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_xr324-4m_poe_ts>>-
cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_xr324-12m_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_xr324-12m>>-
cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_xr324-12m_ts_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_xr324-12m_ts>>-
cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>siplus_net_scalance_x308-2_firmware>>Versions before 4.1.4(exclusive)
cpe:2.3:o:siemens:siplus_net_scalance_x308-2_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>siplus_net_scalance_x308-2>>-
cpe:2.3:h:siemens:siplus_net_scalance_x308-2:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-125Primarynvd@nist.gov
CWE-125Secondaryproductcert@siemens.com
CWE ID: CWE-125
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-125
Type: Secondary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdfproductcert@siemens.com
Mitigation
Patch
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf
Source: productcert@siemens.com
Resource:
Mitigation
Patch
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

894Records found

CVE-2019-6568
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.41% / 60.33%
||
7 Day CHG~0.00%
Published-17 Apr, 2019 | 13:40
Updated-04 Aug, 2024 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.

Action-Not Available
Vendor-Siemens AG
Product-simatic_rf182ccp1604_firmwaresimatic_hmi_ktp_mobile_panels_ktp900_firmwaresimatic_s7-400_pn\/dpsimatic_s7-400_pn_firmwaresimatic_et_200_sp_open_controller_cpu_1515sp_pc2simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmwaresimatic_teleservice_adapter_ie_standard_firmwaresimatic_s7-1500_firmwaresinamics_s150_firmwaresimatic_rf600rsimatic_winac_rtxsinamics_gm150sinamics_s210sinamics_gl150_firmwaresimatic_s7-400_pnsimatic_teleservice_adapter_ie_advanced_firmwaretim_1531_ircsimatic_cp343-1_advancedsinamics_gl150sitop_psu8600_firmwaresimatic_s7-300simatic_rf188csimatic_hmi_comfort_panelssimatic_teleservice_adapter_ie_advancedsitop_ups1600simatic_rf185c_firmwaresimatic_ipc_diagmonitorsitop_managersimatic_winac_rtx_firmwaresinamics_gh150simatic_s7-300_firmwaresimatic_hmi_ktp_mobile_panels_ktp700_firmwarecp1616simatic_rf600r_firmwaresimatic_cp443-1_advanced_firmwaresimatic_hmi_ktp_mobile_panels_ktp700fsimatic_cp343-1_advanced_firmwaresimatic_cp443-1_opc_uasimatic_s7-1500t_firmwaresinamics_sm120simatic_cp443-1_advancedsimatic_s7-1500f_firmwaresimocode_pro_v_eipsitop_ups1600_firmwaresinamics_s210_firmwarecp1616_firmwaresimatic_hmi_ktp_mobile_panels_ktp900sinamics_s150sinamics_sl150_firmwaresimatic_s7-1500ssimatic_cp443-1_firmwarecp1604simatic_s7-1500_software_controllersimocode_pro_v_pnsimatic_rf186c_firmwaresimatic_hmi_ktp_mobile_panels_ktp400fsimatic_rf188c_firmwaresimatic_hmi_comfort_outdoor_panels_firmwaresimatic_rf185csimatic_s7-1500simatic_hmi_ktp_mobile_panels_ktp700f_firmwaresitop_psu8600simatic_s7-400_pn\/dp_firmwaresimatic_teleservice_adapter_ie_basictim_1531_irc_firmwaresimatic_hmi_ktp_mobile_panels_ktp900f_firmwaresimatic_hmi_ktp_mobile_panels_ktp400f_firmwaresimatic_s7-1500tsimatic_s7-1500s_firmwaresinamics_gm150_firmwaresinamics_sm150sinamics_g150sinamics_g130simatic_rf181-eip_firmwaresimatic_s7-1500fsinamics_gh150_firmwaresinamics_sl150simatic_rf182c_firmwaresinamics_sm150_firmwaresimatic_hmi_ktp_mobile_panels_ktp900fsimatic_cp443-1simatic_hmi_comfort_outdoor_panelssimatic_teleservice_adapter_ie_standardsimatic_et_200_sp_open_controller_cpu_1515sp_pc2_firmwaresimatic_rf181-eipsimatic_hmi_ktp_mobile_panels_ktp700simatic_teleservice_adapter_ie_basic_firmwaresinamics_g150_firmwaresimatic_rf186csimatic_et_200_sp_open_controller_cpu_1515sp_pcsimocode_pro_v_eip_firmwaresinamics_s120sinamics_g130_firmwaresimocode_pro_v_pn_firmwaresimatic_hmi_comfort_panels_firmwaresinamics_s120_firmwaresimatic_s7-plcsim_advancedsimatic_wincc_runtime_advancedsinamics_sm120_firmwareSINAMICS S150 V4.6 Control UnitSIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)SINAMICS G130 V4.7 SP1 Control UnitSINAMICS G150 V4.7 Control UnitSINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants)SIMATIC ET 200S IM151-8F PN/DP CPUSIMATIC CP 443-1 OPC UASITOP UPS1600 (incl. SIPLUS variants)SINAMICS G130 V4.6 Control UnitSIMATIC Teleservice Adapter IE StandardSINAMICS G150 V5.1 SP1 Control UnitSINAMICS S150 V4.7 SP1 Control UnitSIMATIC RF186CSIPLUS S7-300 CPU 315F-2 PN/DPSIMATIC S7-300 CPU 317F-2 PN/DPSINAMICS GH150 V4.7 (Control Unit)SIMATIC CP 443-1 AdvancedSINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants)SIMATIC S7-300 CPU 315F-2 PN/DPSIMATIC S7-300 CPU 317-2 PN/DPSIMATIC S7-300 CPU 317TF-3 PN/DPSIMATIC RF600R familySIMATIC CP 443-1SIMOCODE pro V PROFINET (incl. SIPLUS variants)SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900FSINAMICS SL150 V4.8 (Control Unit)SINAMICS GM150 V4.8 (Control Unit)SIMATIC WinCC Runtime AdvancedSINAMICS G150 V4.7 SP1 Control UnitSIMATIC ET 200pro IM154-8F PN/DP CPUSIMATIC S7-300 CPU 317T-3 PN/DPSIMATIC CP 343-1 AdvancedSIMATIC RF185CSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)SINAMICS SM120 V4.7 (Control Unit)SIMATIC S7-300 CPU 319-3 PN/DPSIMATIC Teleservice Adapter IE AdvancedSINAMICS SM150 V4.8 (Control Unit)SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)SINAMICS GH150 V4.8 (Control Unit)SIPLUS ET 200S IM151-8 PN/DP CPUSITOP PSU8600SINAMICS G150 V5.1 Control UnitSIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)SINAMICS G130 V4.7 Control UnitSINAMICS S150 V5.1 SP1 Control UnitSINAMICS SL150 V4.7 (Control Unit)SINAMICS G130 V4.8 Control UnitSIMATIC CP 1604SIMATIC S7-1500 Software ControllerSINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants)SIPLUS ET 200S IM151-8F PN/DP CPUSIPLUS S7-300 CPU 317-2 PN/DPSIMATIC ET 200pro IM154-8 PN/DP CPUSIMATIC RF182CSINAMICS S210SIPLUS S7-300 CPU 317F-2 PN/DPSIPLUS NET CP 443-1SIPLUS S7-300 CPU 314C-2 PN/DPSINAMICS G130 V5.1 SP1 Control UnitSIMATIC WinAC RTX 2010SIMATIC ET 200S IM151-8 PN/DP CPUSINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants)SIMATIC CP 1616SINAMICS GM150 V4.7 (Control Unit)SINAMICS S150 V5.1 Control UnitSIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)SIMATIC S7-300 CPU 314C-2 PN/DPSIPLUS NET CP 343-1 AdvancedSINAMICS S150 V4.7 Control UnitSINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants)SINAMICS GL150 V4.8 (Control Unit)SIMATIC Teleservice Adapter IE BasicSIPLUS NET CP 443-1 AdvancedSITOP ManagerSINAMICS G130 V5.1 Control UnitSINAMICS SM120 V4.8 (Control Unit)SIPLUS S7-300 CPU 315-2 PN/DPSIMATIC S7-PLCSIM AdvancedSIMATIC S7-300 CPU 315-2 PN/DPSINAMICS GL150 V4.7 (Control Unit)SIMATIC S7-300 CPU 319F-3 PN/DPSIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)TIM 1531 IRC (incl. SIPLUS NET variants)SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)SIMATIC WinAC RTX F 2010SINAMICS G150 V4.6 Control UnitSIMATIC RF188CSIMATIC RFID 181EIPSIMATIC ET 200pro IM154-8FX PN/DP CPUSIMATIC S7-300 CPU 315T-3 PN/DPSIMATIC IPC DiagMonitorSINAMICS S150 V4.8 Control UnitSINAMICS G150 V4.8 Control Unit
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-31881
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.1||HIGH
EPSS-1.41% / 79.75%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:31
Updated-11 Mar, 2025 | 09:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)

Action-Not Available
Vendor-Siemens AG
Product-nucleus_readystart_v3talon_tc_compactnucleus_nettalon_tc_compact_firmwareapogee_pxc_compactapogee_modular_equiment_controller_firmwareapogee_pxc_compact_firmwareapogee_modular_equiment_controllerapogee_modular_building_controllercapital_vstarapogee_pxc_modular_firmwareapogee_pxc_modulartalon_tc_modular_firmwaretalon_tc_modularapogee_modular_building_controller_firmwarenucleus_source_codeCapital Embedded AR Classic 431-422Capital Embedded AR Classic R20-11
CWE ID-CWE-125
Out-of-bounds Read
CVE-2019-18306
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.27% / 50.24%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18290, CVE-2019-18291, CVE-2019-18292, CVE-2019-18294, CVE-2019-18298, CVE-2019-18299, CVE-2019-18300, CVE-2019-18301, CVE-2019-18302, CVE-2019-18303, CVE-2019-18304, CVE-2019-18305, and CVE-2019-18307. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-125
Out-of-bounds Read
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-18307
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.22% / 44.33%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 01:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18290, CVE-2019-18291, CVE-2019-18292, CVE-2019-18294, CVE-2019-18298, CVE-2019-18299, CVE-2019-18300, CVE-2019-18301, CVE-2019-18302, CVE-2019-18303, CVE-2019-18304, CVE-2019-18305, and CVE-2019-18306. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sppa-t3000_ms3000_migration_serverSPPA-T3000 MS3000 Migration Server
CWE ID-CWE-125
Out-of-bounds Read
CVE-2020-35683
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.53% / 66.41%
||
7 Day CHG~0.00%
Published-19 Aug, 2021 | 11:13
Updated-04 Aug, 2024 | 17:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in HCC Nichestack 3.0. The code that parses ICMP packets relies on an unchecked value of the IP payload size (extracted from the IP header) to compute the ICMP checksum. When the IP payload size is set to be smaller than the size of the IP header, the ICMP checksum computation function may read out of bounds, causing a Denial-of-Service.

Action-Not Available
Vendor-hcc-embeddedn/aSiemens AG
Product-7km9300-0ae02-0aa0nichestack7km9300-0ae02-0aa0_firmwaren/a
CWE ID-CWE-125
Out-of-bounds Read
CVE-2018-16890
Matching Score-10
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-10
Assigner-Red Hat, Inc.
CVSS Score-5.4||MEDIUM
EPSS-0.89% / 74.49%
||
7 Day CHG~0.00%
Published-06 Feb, 2019 | 20:00
Updated-05 Aug, 2024 | 10:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

libcurl versions from 7.36.0 to before 7.64.0 is vulnerable to a heap buffer out-of-bounds read. The function handling incoming NTLM type-2 messages (`lib/vauth/ntlm.c:ntlm_decode_type2_target`) does not validate incoming data correctly and is subject to an integer overflow vulnerability. Using that overflow, a malicious or broken NTLM server could trick libcurl to accept a bad length + offset combination that would lead to a buffer read out-of-bounds.

Action-Not Available
Vendor-NetApp, Inc.Debian GNU/LinuxOracle CorporationRed Hat, Inc.Canonical Ltd.F5, Inc.Siemens AGCURL
Product-libcurlclustered_data_ontapubuntu_linuxdebian_linuxcommunications_operations_monitorhttp_serversecure_global_desktopenterprise_linuxsinema_remote_connect_clientbig-ip_access_policy_managercurl
CWE ID-CWE-125
Out-of-bounds Read
CWE ID-CWE-190
Integer Overflow or Wraparound
CVE-2024-22040
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.33% / 55.00%
||
7 Day CHG~0.00%
Published-12 Mar, 2024 | 10:21
Updated-01 Aug, 2024 | 22:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions), Cerberus PRO EN Fire Panel FC72x IP6 (All versions), Cerberus PRO EN Fire Panel FC72x IP7 (All versions), Cerberus PRO EN Fire Panel FC72x IP8 (All versions < IP8 SR4), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.3.5618), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.3.5617), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions), Sinteso FS20 EN Fire Panel FC20 MP8 (All versions < MP8 SR4), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.3.5618), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.3.5617), Sinteso Mobile (All versions). The network communication library in affected systems insufficiently validates HMAC values which might result in a buffer overread. This could allow an unauthenticated remote attacker to crash the network service.

Action-Not Available
Vendor-Siemens AG
Product-Cerberus PRO EN Fire Panel FC72x IP7Sinteso FS20 EN X300 Cloud Distribution MP7Sinteso MobileCerberus PRO UL X300 Cloud DistributionSinteso FS20 EN Engineering ToolDesigo Fire Safety UL Compact Panel FC2025/2050Desigo Fire Safety UL Engineering ToolSinteso FS20 EN X200 Cloud Distribution MP8Cerberus PRO UL Engineering ToolSinteso FS20 EN Fire Panel FC20 MP8Sinteso FS20 EN X300 Cloud Distribution MP8Cerberus PRO UL Compact Panel FC922/924Sinteso FS20 EN Fire Panel FC20 MP7Cerberus PRO EN Fire Panel FC72x IP8Cerberus PRO EN X300 Cloud Distribution IP7Desigo Fire Safety UL X300 Cloud DistributionCerberus PRO EN Engineering ToolSinteso FS20 EN X200 Cloud Distribution MP7Cerberus PRO EN Fire Panel FC72x IP6Cerberus PRO EN X200 Cloud Distribution IP7Sinteso FS20 EN Fire Panel FC20 MP6Cerberus PRO EN X200 Cloud Distribution IP8Cerberus PRO EN X300 Cloud Distribution IP8cerberus_pro_ul_engineering_toolsinteso_fs20_en_engineering_toolcerberus_pro_ul_compact_panelcerberus_pro_en_fire_panel_fc72xcerberus_pro_en_engineering_toolcerberus_pro_en_x300_cloud_distributioncerberus_pro_ul_x300_cloudsinteso_fs20_en_x300_cloud_distributiondesigo_fire_safety_ul_engineering_tooldesigo_fire_safety_ul_compact_panelsinteso_fs20_en_fire_panel_fc20sinteso_mobilesinteso_fs20_en_x200_cloud_distributioncerberus_pro_en_x200_cloud_distribution
CWE ID-CWE-125
Out-of-bounds Read
CVE-2022-31812
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.12% / 31.94%
||
7 Day CHG~0.00%
Published-23 May, 2025 | 15:03
Updated-22 Aug, 2025 | 19:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SiPass integrated (All versions < V2.95.3.18). Affected server applications contain an out of bounds read past the end of an allocated buffer while checking the integrity of incoming packets. This could allow an unauthenticated remote attacker to create a denial of service condition.

Action-Not Available
Vendor-Siemens AG
Product-sipass_integratedSiPass integrated
CWE ID-CWE-125
Out-of-bounds Read
CVE-2025-30174
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.08% / 23.58%
||
7 Day CHG~0.00%
Published-13 May, 2025 | 09:38
Updated-08 Jul, 2025 | 11:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.

Action-Not Available
Vendor-Siemens AG
Product-Totally Integrated Automation Portal (TIA Portal) V19SIMATIC PCS neo V4.1Totally Integrated Automation Portal (TIA Portal) V17Totally Integrated Automation Portal (TIA Portal) V20SINEC NMSTotally Integrated Automation Portal (TIA Portal) V18SINEMA Remote ConnectSIMATIC PCS neo V5.0User Management Component (UMC)
CWE ID-CWE-125
Out-of-bounds Read
CVE-2025-30176
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.08% / 23.58%
||
7 Day CHG~0.00%
Published-13 May, 2025 | 09:38
Updated-08 Jul, 2025 | 11:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.

Action-Not Available
Vendor-Siemens AG
Product-Totally Integrated Automation Portal (TIA Portal) V19SIMATIC PCS neo V4.1Totally Integrated Automation Portal (TIA Portal) V17Totally Integrated Automation Portal (TIA Portal) V20SINEC NMSTotally Integrated Automation Portal (TIA Portal) V18SINEMA Remote ConnectSIMATIC PCS neo V5.0User Management Component (UMC)
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-20094
Matching Score-10
Assigner-Tenable Network Security, Inc.
ShareView Details
Matching Score-10
Assigner-Tenable Network Security, Inc.
CVSS Score-7.5||HIGH
EPSS-2.54% / 84.88%
||
7 Day CHG~0.00%
Published-16 Jun, 2021 | 11:09
Updated-03 Aug, 2024 | 17:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A denial of service vulnerability exists in Wibu-Systems CodeMeter versions < 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server.

Action-Not Available
Vendor-wibun/aSiemens AG
Product-sicam_230pss_capesicam_230_firmwarecodemeterWibu-Systems CodeMeter
CWE ID-CWE-125
Out-of-bounds Read
CVE-2020-13987
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.19% / 40.62%
||
7 Day CHG~0.00%
Published-11 Dec, 2020 | 21:37
Updated-04 Aug, 2024 | 12:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Contiki through 3.0. An Out-of-Bounds Read vulnerability exists in the uIP TCP/IP Stack component when calculating the checksums for IP packets in upper_layer_chksum in net/ipv4/uip.c.

Action-Not Available
Vendor-uip_projectopen-iscsi_projectcontiki-osn/aSiemens AG
Product-contikisentron_3va_com800_firmwaresentron_3va_com800uipsentron_3va_com100open-iscsisentron_pac3200sentron_pac3200_firmwaresentron_pac4200sentron_pac4200_firmwaresentron_3va_com100_firmwaren/a
CWE ID-CWE-125
Out-of-bounds Read
CVE-2024-46891
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.9||MEDIUM
EPSS-0.19% / 40.95%
||
7 Day CHG+0.02%
Published-12 Nov, 2024 | 12:49
Updated-20 Aug, 2025 | 19:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly restrict the size of generated log files. This could allow an unauthenticated remote attacker to trigger a large amount of logged events to exhaust the system's resources and create a denial of service condition.

Action-Not Available
Vendor-Siemens AG
Product-sinec_insSINEC INSsinec_ins
CWE ID-CWE-125
Out-of-bounds Read
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2021-44694
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.5||MEDIUM
EPSS-0.07% / 22.25%
||
7 Day CHG~0.00%
Published-13 Dec, 2022 | 00:00
Updated-21 Apr, 2025 | 13:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.

Action-Not Available
Vendor-Siemens AG
Product-simatic_s7-1500_cpu_1507ssimatic_s7-1200_cpu_12_1214fcsimatic_s7-1500_cpu_cpu_1513pro-2simatic_s7-1500_cpu_1511csimatic_s7-1500_cpu_1511t-1_firmwaresimatic_s7-1500_cpu_1512sp-1siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmwaresimatic_et_200_sp_open_controller_cpu_1515sp_pc_firmwaresimatic_s7-1200_cpu_12_1214c_firmwaresimatic_s7-1200_cpu_12_1211csimatic_s7-1500_cpu_1508s_f_firmwaresimatic_s7-1500_cpu_1510sp-1simatic_s7-1200_cpu_1212csimatic_s7-1500_cpu_1512spf-1simatic_s7-1500_cpu_1513-1simatic_s7-1200_cpu_1212fc_firmwaresimatic_s7-1500_cpu_1517-3_pnsimatic_s7-1500_cpu_1515-2_pn_firmwaresimatic_s7-1500_cpu_1517f-3_pn\/dpsimatic_s7-1500_cpu_1513r-1simatic_s7-1200_cpu_1215_fcsimatic_s7-1500_cpu_1512c_firmwaresimatic_s7-1500_cpu_1517f-3_pn\/dp_firmwaresimatic_s7-1200_cpu_12_1215csimatic_s7-1500_cpu_1511-1_firmwaresimatic_s7-1500_cpu_1511-1_pnsimatic_s7-1500_cpu_1517f-3_firmwaresimatic_s7-1500_cpu_1518f-4_pn\/dp_firmwaresimatic_s7-1500_cpu_1518hf-4simatic_s7-1500_cpu_1518-4_pn_firmwaresiplus_tim_1531_irc_firmwaresimatic_s7-1500_cpu_1518-4_dp_firmwaresimatic_s7-1500_cpu_1516tf-3_firmwaresimatic_s7-1500_cpu_1511f-1_pn_firmwaresimatic_s7-1500_cpu_1516-3_firmwaresimatic_s7-1500_cpu_1518-4_pn\/dp_mfp_firmwaresimatic_s7-1500_cpu_1517-3_pn\/dpsimatic_s7-1500_cpu_1517-3simatic_s7-1500_cpu_1518t-4_firmwaresimatic_s7-1500_cpu_1508s_fsimatic_s7-1500_cpu_15prof-2_firmwaresimatic_s7-1500_cpu_1513f-1_pnsimatic_s7-1200_cpu_1214c_firmwaresimatic_s7-1500_cpu_1517-3_pn_firmwaresimatic_s7-1500_cpu_1517-3_dpsimatic_s7-1200_cpu_12_1214csimatic_s7-1200_cpu_1211c_firmwaresimatic_s7-1500_cpu_cpu_1513pro-2_firmwaresimatic_s7-1200_cpu_1214csiplus_tim_1531_ircsimatic_s7-1500_cpu_15prof-2simatic_s7-1500_cpu_1516tf-3simatic_s7-1500_cpu_1516f-3_pn\/dp_firmwaresimatic_s7-1500_cpu_151511f-1_firmwaresimatic_s7-1500_cpu_1507s_f_firmwaresimatic_s7-1500_cpu_1516t-3_firmwaresimatic_s7-1500_cpu_1511t-1simatic_s7-1500_cpu_1517tf-3simatic_s7-1500_cpu_1515-2_pnsimatic_s7-1200_cpu_1214_fcsimatic_s7-1500_cpu_1515-2_firmwaresimatic_s7-1500_cpu_1516pro-2_firmwaretim_1531_irc_firmwaresimatic_s7-1500_cpu_1515-2simatic_s7-1500_cpu_1516-3_pnsimatic_s7-1500_cpu_1516pro_f_firmwaresimatic_s7-1500_cpu_1516-3simatic_s7-1200_cpu_1214fcsimatic_s7-1500_cpu_1518f-4_pn\/dpsimatic_s7-1500_cpu_1508s_firmwaresimatic_s7-1500_cpu_1511f-1_firmwaresimatic_s7-1200_cpu_12_1212fcsimatic_s7-1500_cpu_151511c-1simatic_s7-1500_cpu_1518tf-4_firmwaresiplus_s7-1200_cp_1243-1simatic_s7-1500_cpu_1511f-1_pnsimatic_s7-1500_cpu_1507s_fsimatic_s7-1500_cpu_1518simatic_s7-1500_cpu_1513-1_pn_firmwaresimatic_s7-1200_cpu_1215fcsimatic_s7-1500_cpu_1518f-4simatic_s7-1500_cpu_1516pro_fsimatic_s7-1500_cpu_1513r-1_firmwaresimatic_et_200_sp_open_controller_cpu_1515sp_pcsimatic_s7-1500_cpu_1512c-1_firmwaresimatic_s7-1500_cpu_1513f-1_pn_firmwaresiplus_et_200sp_cp_1543sp-1_isec_firmwaresimatic_s7-1500_cpu_1518_firmwaresimatic_s7-1500_cpu_1518-4_firmwaresimatic_s7-1500_cpu_1518tf-4simatic_s7-1200_cpu_1214_fc_firmwaresiplus_s7-1200_cp_1243-1_railsimatic_s7-1500_cpu_1516t-3simatic_s7-1500_cpu_1510sp_firmwaresimatic_s7-1500_cpu_1518-4_pn\/dp_mfpsiplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmwaresimatic_s7-1200_cpu_1215_fc_firmwaresimatic_s7-1200_cpu_12_1215fc_firmwaresimatic_s7-1500_cpu_1515t-2simatic_s7-1500_cpu_15pro-2simatic_s7-1500_cpu_1518-4_pnsimatic_s7-1200_cpu_12_1212c_firmwaresimatic_s7-1200_cpu_12_1212fc_firmwaresimatic_s7-1500_cpu_1511-1_pn_firmwaresimatic_s7-1500_cpu_15pro-2_firmwaresimatic_s7-1500_cpu_1515tf-2_firmwaretim_1531_ircsimatic_s7-1500_cpu_151511c-1_firmwaresimatic_s7-1200_cpu_12_1217csimatic_s7-1500_cpu_1518-4_pn\/dp_firmwaresimatic_s7-1500_cpu_1510spsimatic_s7-1200_cpu_12_1217c_firmwaresimatic_s7-1500_cpu_1518f-4_firmwaresimatic_s7-1200_cpu_1217csimatic_s7-1500_cpu_151511f-1simatic_s7-1500_software_controller_firmwaresimatic_s7-1500_cpu_1511-1simatic_s7-1500_cpu_1518-4_dpsimatic_s7-1200_cpu_1215c_firmwaresimatic_s7-1500_cpu_1513-1_pnsimatic_s7-1200_cpu_1212c_firmwaresimatic_s7-1500_cpu_1515f-2_firmwaresimatic_s7-1200_cpu_1217c_firmwaresimatic_s7-1200_cpu_1214fc_firmwaresimatic_s7-1500_cpu_cpu_1513prof-2_firmwaresimatic_s7-1200_cpu_1215csimatic_s7-1500_cpu_1515r-2simatic_s7-1200_cpu_12_1215fcsiplus_et_200sp_cp_1543sp-1_isecsimatic_s7-1500_cpu_1513f-1simatic_s7-1500_cpu_1512csimatic_s7-1500_cpu_1516f-3_pn\/dpsimatic_s7-1500_cpu_1511c-1simatic_s7-1500_cpu_1517f-3simatic_s7-1500_cpu_1512spf-1_firmwaresiplus_et_200sp_cp_1543sp-1_isec_tx_railsimatic_s7-1500_cpu_1517tf-3_firmwaresimatic_s7-1500_cpu_1516f-3_firmwaresimatic_s7-1500_cpu_1517-3_firmwaresimatic_s7-1200_cpu_12_1214fc_firmwaresimatic_s7-1500_software_controllersimatic_s7-1500_cpu_1511c-1_firmwaresimatic_s7-1500_cpu_1517-3_dp_firmwaresimatic_s7-1500_cpu_1516-3_pn\/dp_firmwaresimatic_s7-1500_cpu_1518hf-4_firmwaresimatic_s7-1200_cpu_12_1212csimatic_s7-1500_cpu_1511f-1simatic_s7-1500_cpu_1515tf-2siplus_s7-1200_cp_1243-1_rail_firmwaresimatic_s7-1500_cpu_1511c_firmwaresimatic_s7-1500_cpu_1511tf-1simatic_s7-1500_cpu_1518-4simatic_s7-1500_cpu_1518-4_pn\/dpsiplus_s7-1200_cp_1243-1_firmwaresimatic_s7-1500_cpu_1511tf-1_firmwaresimatic_s7-1500_cpu_1517-3_pn\/dp_firmwaresimatic_s7-1500_cpu_1516-3_dpsimatic_s7-1500_cpu_1508ssimatic_s7-plcsim_advanced_firmwaresimatic_s7-1500_cpu_1510sp-1_firmwaresimatic_s7-1500_cpu_1516-3_pn\/dpsimatic_s7-1500_cpu_1515f-2_pn_firmwaresimatic_s7-1500_cpu_1515t-2_firmwaresiplus_et_200sp_cp_1542sp-1_irc_tx_railsimatic_s7-1500_cpu_1516-3_dp_firmwaresimatic_s7-1200_cpu_12_1215c_firmwaresimatic_s7-1500_cpu_1512sp-1_firmwaresimatic_s7-1200_cpu_1215fc_firmwaresimatic_s7-1500_cpu_1512c-1simatic_s7-1500_cpu_1515f-2simatic_s7-1500_cpu_cpu_1513prof-2simatic_s7-1500_cpu_1515f-2_pnsimatic_s7-1200_cpu_1211csimatic_s7-1500_cpu_1516f-3simatic_s7-1500_cpu_1516-3_pn_firmwaresimatic_s7-1200_cpu_12_1211c_firmwaresimatic_s7-plcsim_advancedsimatic_s7-1500_cpu_1513f-1_firmwaresimatic_s7-1200_cpu_1212fcsimatic_s7-1500_cpu_1516pro-2simatic_s7-1500_cpu_1515r-2_firmwaresimatic_s7-1500_cpu_1507s_firmwaresimatic_s7-1500_cpu_1513-1_firmwaresimatic_s7-1500_cpu_1518t-4SIMATIC S7-1500 CPU 1512C-1 PNSIMATIC S7-1500 CPU 1517F-3 PN/DPSIMATIC S7-1500 CPU 1515-2 PNSIMATIC S7-1500 CPU 1511T-1 PNSIPLUS S7-1500 CPU 1518-4 PN/DPSIPLUS S7-1500 CPU 1518F-4 PN/DPSIPLUS S7-1500 CPU 1518-4 PN/DP MFPSIMATIC S7-1500 CPU 1515TF-2 PNSIMATIC S7-1500 CPU 1510SP-1 PNSIMATIC S7-1500 CPU 1516-3 PN/DPSIMATIC S7-1500 CPU 1511TF-1 PNSIPLUS S7-1500 CPU 1515F-2 PNSIPLUS S7-1500 CPU 1517H-3 PNSIPLUS ET 200SP CPU 1510SP F-1 PN RAILSIMATIC S7-1500 CPU 1518HF-4 PNSIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PNSIPLUS ET 200SP CPU 1512SP-1 PN RAILSIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PNSIPLUS ET 200SP CPU 1510SP-1 PN RAILSIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PNSIMATIC S7-PLCSIM AdvancedSIMATIC S7-1500 CPU 1517-3 PN/DPSIMATIC S7-1500 CPU 1517H-3 PNSIMATIC S7-1500 CPU 1516TF-3 PN/DPSIMATIC S7-1500 CPU 1515T-2 PNSIMATIC S7-1500 CPU S7-1518-4 PN/DP ODKSIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PNSIPLUS S7-1500 CPU 1516-3 PN/DP RAILSIPLUS S7-1500 CPU 1516-3 PN/DP TX RAILSIMATIC S7-1500 CPU 1511C-1 PNSIMATIC S7-1500 CPU 1517TF-3 PN/DPSIMATIC S7-1200 CPU family (incl. SIPLUS variants)SIPLUS S7-1500 CPU 1515F-2 PN T2 RAILSIPLUS S7-1500 CPU 1511-1 PN TX RAILSIPLUS S7-1500 CPU 1513F-1 PNSIMATIC Drive Controller CPU 1507D TFSIMATIC Drive Controller CPU 1504D TFSIMATIC S7-1500 CPU 1513R-1 PNSIPLUS S7-1500 CPU 1516-3 PN/DPSIMATIC S7-1500 CPU 1515R-2 PNSIMATIC S7-1500 CPU 1512SP F-1 PNTIM 1531 IRCSIPLUS S7-1500 CPU 1511F-1 PNSIPLUS ET 200SP CPU 1512SP F-1 PN RAILSIMATIC S7-1500 Software Controller V2SIMATIC S7-1500 CPU 1518F-4 PN/DP MFPSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)SIPLUS ET 200SP CPU 1512SP F-1 PNSIMATIC S7-1500 CPU 1515F-2 PNSIMATIC S7-1500 CPU 1518-4 PN/DPSIMATIC S7-1500 CPU 1513-1 PNSIPLUS ET 200SP CPU 1510SP F-1 PNSIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODKSIMATIC S7-1500 CPU 1518F-4 PN/DPSIMATIC S7-1500 CPU 1518-4 PN/DP MFPSIPLUS ET 200SP CPU 1510SP-1 PNSIPLUS S7-1500 CPU 1516F-3 PN/DPSIMATIC S7-1500 CPU 1516T-3 PN/DPSIMATIC S7-1500 CPU 1518TF-4 PN/DPSIPLUS S7-1500 CPU 1515R-2 PN TX RAILSIMATIC S7-1500 CPU 1512SP-1 PNSIMATIC S7-1500 CPU 1518T-4 PN/DPSIMATIC S7-1500 CPU 1511-1 PNSIMATIC S7-1500 CPU 1517T-3 PN/DPSIPLUS S7-1500 CPU 1518HF-4 PNSIPLUS S7-1500 CPU 1513-1 PNSIPLUS S7-1500 CPU 1515R-2 PNSIMATIC S7-1500 CPU 1513F-1 PNSIMATIC S7-1500 CPU 1510SP F-1 PNSIPLUS S7-1500 CPU 1515F-2 PN RAILSIPLUS TIM 1531 IRCSIMATIC S7-1500 CPU 1511F-1 PNSIMATIC S7-1500 CPU 1516F-3 PN/DPSIPLUS ET 200SP CPU 1512SP-1 PNSIPLUS S7-1500 CPU 1511-1 PN T1 RAILSIPLUS S7-1500 CPU 1511-1 PNSIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL
CWE ID-CWE-1287
Improper Validation of Specified Type of Input
CWE ID-CWE-20
Improper Input Validation
CVE-2021-44695
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-4.9||MEDIUM
EPSS-0.06% / 19.70%
||
7 Day CHG~0.00%
Published-13 Dec, 2022 | 00:00
Updated-21 Apr, 2025 | 13:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.

Action-Not Available
Vendor-Siemens AG
Product-simatic_s7-1500_cpu_1507ssimatic_s7-1200_cpu_12_1214fcsimatic_s7-1500_cpu_cpu_1513pro-2simatic_s7-1500_cpu_1511csimatic_s7-1500_cpu_1511t-1_firmwaresimatic_s7-1500_cpu_1512sp-1siplus_s7-300_cpu_314siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmwaresimatic_et_200_sp_open_controller_cpu_1515sp_pc_firmwaresimatic_s7-1200_cpu_12_1214c_firmwaresimatic_s7-1200_cpu_12_1211csimatic_s7-1500_cpu_1508s_f_firmwaresimatic_s7-1500_cpu_1510sp-1simatic_s7-1200_cpu_1212csimatic_s7-1500_cpu_1512spf-1simatic_s7-1500_cpu_1513-1simatic_s7-1200_cpu_1212fc_firmwaresimatic_s7-1500_cpu_1517-3_pnsimatic_s7-1500_cpu_1515-2_pn_firmwaresimatic_s7-1500_cpu_1517f-3_pn\/dpsimatic_s7-1500_cpu_1513r-1simatic_s7-1200_cpu_1215_fcsimatic_s7-1500_cpu_1512c_firmwaresimatic_s7-1500_cpu_1517f-3_pn\/dp_firmwaresimatic_s7-1200_cpu_12_1215csimatic_s7-1500_cpu_1511-1_firmwaresimatic_s7-1500_cpu_1511-1_pnsimatic_s7-1500_cpu_1517f-3_firmwaresimatic_s7-1500_cpu_1518f-4_pn\/dp_firmwaresimatic_s7-1500_cpu_1518hf-4simatic_s7-1500_cpu_1518-4_pn_firmwaresiplus_tim_1531_irc_firmwaresimatic_s7-1500_cpu_1518-4_dp_firmwaresimatic_s7-1500_cpu_1516tf-3_firmwaresimatic_s7-1500_cpu_1511f-1_pn_firmwaresimatic_s7-1500_cpu_1516-3_firmwaresimatic_s7-1500_cpu_1518-4_pn\/dp_mfp_firmwaresimatic_s7-1500_cpu_1517-3_pn\/dpsimatic_s7-1500_cpu_1517-3simatic_s7-1500_cpu_1518t-4_firmwaresimatic_s7-1500_cpu_1508s_fsimatic_s7-1500_cpu_15prof-2_firmwaresimatic_s7-1500_cpu_1513f-1_pnsimatic_s7-1200_cpu_1214c_firmwaresimatic_s7-1500_cpu_1517-3_pn_firmwaresimatic_s7-1500_cpu_1517-3_dpsimatic_s7-1200_cpu_12_1214csimatic_s7-1200_cpu_1211c_firmwaresimatic_s7-1500_cpu_cpu_1513pro-2_firmwaresimatic_s7-1200_cpu_1214csiplus_tim_1531_ircsimatic_s7-1500_cpu_15prof-2simatic_s7-1500_cpu_1516tf-3siplus_s7-300_cpu_315-2_pn\/dp_firmwaresimatic_s7-1500_cpu_1516f-3_pn\/dp_firmwaresimatic_s7-1500_cpu_151511f-1_firmwaresimatic_s7-1500_cpu_1507s_f_firmwaresimatic_s7-1500_cpu_1516t-3_firmwaresimatic_s7-1500_cpu_1511t-1simatic_s7-1500_cpu_1517tf-3simatic_s7-1500_cpu_1515-2_pnsimatic_s7-1200_cpu_1214_fcsimatic_s7-1500_cpu_1515-2_firmwaresimatic_s7-1500_cpu_1516pro-2_firmwaretim_1531_irc_firmwaresimatic_s7-1500_cpu_1515-2simatic_s7-1500_cpu_1516-3_pnsimatic_s7-1500_cpu_1516pro_f_firmwaresimatic_s7-1500_cpu_1516-3simatic_s7-1200_cpu_1214fcsimatic_s7-1500_cpu_1518f-4_pn\/dpsimatic_s7-1500_cpu_1508s_firmwaresimatic_s7-1500_cpu_1511f-1_firmwaresimatic_s7-1200_cpu_12_1212fcsimatic_s7-1500_cpu_151511c-1simatic_s7-1500_cpu_1518tf-4_firmwaresiplus_s7-1200_cp_1243-1simatic_s7-1500_cpu_1511f-1_pnsimatic_s7-1500_cpu_1507s_fsiplus_s7-300_cpu_315-2_dpsimatic_s7-1500_cpu_1518simatic_s7-1500_cpu_1513-1_pn_firmwaresimatic_s7-1200_cpu_1215fcsimatic_s7-1500_cpu_1518f-4simatic_s7-1500_cpu_1516pro_fsimatic_s7-1500_cpu_1513r-1_firmwaresimatic_et_200_sp_open_controller_cpu_1515sp_pcsimatic_s7-1500_cpu_1512c-1_firmwaresimatic_s7-1500_cpu_1513f-1_pn_firmwaresiplus_et_200sp_cp_1543sp-1_isec_firmwaresimatic_s7-1500_cpu_1518_firmwaresimatic_s7-1500_cpu_1518-4_firmwaresimatic_s7-1500_cpu_1518tf-4simatic_s7-1200_cpu_1214_fc_firmwaresiplus_s7-1200_cp_1243-1_railsimatic_s7-1500_cpu_1516t-3simatic_s7-1500_cpu_1510sp_firmwaresimatic_s7-1500_cpu_1518-4_pn\/dp_mfpsiplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmwaresimatic_s7-1200_cpu_1215_fc_firmwaresimatic_s7-1200_cpu_12_1215fc_firmwaresimatic_s7-1500_cpu_1515t-2simatic_s7-1500_cpu_15pro-2simatic_s7-1500_cpu_1518-4_pnsimatic_s7-1200_cpu_12_1212c_firmwaresimatic_s7-1200_cpu_12_1212fc_firmwaresimatic_s7-1500_cpu_1511-1_pn_firmwaresimatic_s7-1500_cpu_15pro-2_firmwaresimatic_s7-1500_cpu_1515tf-2_firmwaretim_1531_ircsimatic_s7-1500_cpu_151511c-1_firmwaresimatic_s7-1200_cpu_12_1217csimatic_s7-1500_cpu_1518-4_pn\/dp_firmwaresimatic_s7-1500_cpu_1510spsimatic_s7-1200_cpu_12_1217c_firmwaresimatic_s7-1500_cpu_1518f-4_firmwaresimatic_s7-1200_cpu_1217csimatic_s7-1500_cpu_151511f-1simatic_s7-1500_software_controller_firmwaresimatic_s7-1500_cpu_1511-1simatic_s7-1500_cpu_1518-4_dpsiplus_s7-300_cpu_317-2_pn\/dp_firmwaresimatic_s7-1200_cpu_1215c_firmwaresimatic_s7-1500_cpu_1513-1_pnsimatic_s7-1200_cpu_1212c_firmwaresimatic_s7-1500_cpu_1515f-2_firmwaresimatic_s7-1200_cpu_1217c_firmwaresimatic_s7-1200_cpu_1214fc_firmwaresimatic_s7-1500_cpu_cpu_1513prof-2_firmwaresimatic_s7-1200_cpu_1215csimatic_s7-1500_cpu_1515r-2simatic_s7-1200_cpu_12_1215fcsiplus_et_200sp_cp_1543sp-1_isecsimatic_s7-1500_cpu_1513f-1simatic_s7-1500_cpu_1512csimatic_s7-1500_cpu_1516f-3_pn\/dpsimatic_s7-1500_cpu_1511c-1simatic_s7-1500_cpu_1517f-3simatic_s7-1500_cpu_1512spf-1_firmwaresiplus_s7-300_cpu_314_firmwaresiplus_et_200sp_cp_1543sp-1_isec_tx_railsimatic_s7-1500_cpu_1517tf-3_firmwaresimatic_s7-1500_cpu_1516f-3_firmwaresimatic_s7-1500_cpu_1517-3_firmwaresimatic_s7-1200_cpu_12_1214fc_firmwaresimatic_s7-1500_software_controllersimatic_s7-1500_cpu_1511c-1_firmwaresimatic_s7-1500_cpu_1517-3_dp_firmwaresimatic_s7-1500_cpu_1516-3_pn\/dp_firmwaresimatic_s7-1500_cpu_1518hf-4_firmwaresimatic_s7-1200_cpu_12_1212csiplus_s7-300_cpu_315-2_pn\/dpsimatic_s7-1500_cpu_1511f-1siplus_s7-300_cpu_317-2_pn\/dpsimatic_s7-1500_cpu_1515tf-2siplus_s7-1200_cp_1243-1_rail_firmwaresimatic_s7-1500_cpu_1511c_firmwaresimatic_s7-1500_cpu_1511tf-1simatic_s7-1500_cpu_1518-4simatic_s7-1500_cpu_1518-4_pn\/dpsiplus_s7-1200_cp_1243-1_firmwaresimatic_s7-1500_cpu_1511tf-1_firmwaresimatic_s7-1500_cpu_1517-3_pn\/dp_firmwaresimatic_s7-1500_cpu_1516-3_dpsimatic_s7-1500_cpu_1508ssiplus_s7-300_cpu_315-2_dp_firmwaresimatic_s7-plcsim_advanced_firmwaresimatic_s7-1500_cpu_1510sp-1_firmwaresimatic_s7-1500_cpu_1516-3_pn\/dpsimatic_s7-1500_cpu_1515f-2_pn_firmwaresimatic_s7-1500_cpu_1515t-2_firmwaresiplus_et_200sp_cp_1542sp-1_irc_tx_railsimatic_s7-1500_cpu_1516-3_dp_firmwaresimatic_s7-1200_cpu_12_1215c_firmwaresimatic_s7-1500_cpu_1512sp-1_firmwaresimatic_s7-1200_cpu_1215fc_firmwaresimatic_s7-1500_cpu_1512c-1simatic_s7-1500_cpu_1515f-2simatic_s7-1500_cpu_cpu_1513prof-2simatic_s7-1500_cpu_1515f-2_pnsimatic_s7-1200_cpu_1211csimatic_s7-1500_cpu_1516f-3simatic_s7-1500_cpu_1516-3_pn_firmwaresimatic_s7-1200_cpu_12_1211c_firmwaresimatic_s7-plcsim_advancedsimatic_s7-1500_cpu_1513f-1_firmwaresimatic_s7-1200_cpu_1212fcsimatic_s7-1500_cpu_1516pro-2simatic_s7-1500_cpu_1515r-2_firmwaresimatic_s7-1500_cpu_1507s_firmwaresimatic_s7-1500_cpu_1513-1_firmwaresimatic_s7-1500_cpu_1518t-4SIMATIC S7-1500 CPU 1512C-1 PNSIMATIC S7-1500 CPU 1517F-3 PN/DPSIMATIC S7-1500 CPU 1515-2 PNSIMATIC S7-1500 CPU 1511T-1 PNSIPLUS S7-1500 CPU 1518-4 PN/DPSIPLUS S7-1500 CPU 1518F-4 PN/DPSIPLUS S7-1500 CPU 1518-4 PN/DP MFPSIMATIC S7-1500 CPU 1515TF-2 PNSIMATIC S7-1500 CPU 1510SP-1 PNSIMATIC S7-1500 CPU 1516-3 PN/DPSIMATIC S7-1500 CPU 1511TF-1 PNSIPLUS S7-1500 CPU 1515F-2 PNSIPLUS S7-1500 CPU 1517H-3 PNSIPLUS ET 200SP CPU 1510SP F-1 PN RAILSIMATIC S7-1500 CPU 1518HF-4 PNSIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PNSIPLUS ET 200SP CPU 1512SP-1 PN RAILSIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PNSIPLUS ET 200SP CPU 1510SP-1 PN RAILSIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PNSIMATIC S7-PLCSIM AdvancedSIMATIC S7-1500 CPU 1517-3 PN/DPSIMATIC S7-1500 CPU 1517H-3 PNSIMATIC S7-1500 CPU 1516TF-3 PN/DPSIMATIC S7-1500 CPU 1515T-2 PNSIMATIC S7-1500 CPU S7-1518-4 PN/DP ODKSIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PNSIPLUS S7-1500 CPU 1516-3 PN/DP RAILSIPLUS S7-1500 CPU 1516-3 PN/DP TX RAILSIMATIC S7-1500 CPU 1511C-1 PNSIMATIC S7-1500 CPU 1517TF-3 PN/DPSIMATIC S7-1200 CPU family (incl. SIPLUS variants)SIPLUS S7-1500 CPU 1515F-2 PN T2 RAILSIPLUS S7-1500 CPU 1511-1 PN TX RAILSIPLUS S7-1500 CPU 1513F-1 PNSIMATIC Drive Controller CPU 1507D TFSIMATIC Drive Controller CPU 1504D TFSIMATIC S7-1500 CPU 1513R-1 PNSIPLUS S7-1500 CPU 1516-3 PN/DPSIMATIC S7-1500 CPU 1515R-2 PNSIMATIC S7-1500 CPU 1512SP F-1 PNTIM 1531 IRCSIPLUS S7-1500 CPU 1511F-1 PNSIPLUS ET 200SP CPU 1512SP F-1 PN RAILSIMATIC S7-1500 Software Controller V2SIMATIC S7-1500 CPU 1518F-4 PN/DP MFPSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)SIPLUS ET 200SP CPU 1512SP F-1 PNSIMATIC S7-1500 CPU 1515F-2 PNSIMATIC S7-1500 CPU 1518-4 PN/DPSIMATIC S7-1500 CPU 1513-1 PNSIPLUS ET 200SP CPU 1510SP F-1 PNSIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODKSIMATIC S7-1500 CPU 1518F-4 PN/DPSIMATIC S7-1500 CPU 1518-4 PN/DP MFPSIPLUS ET 200SP CPU 1510SP-1 PNSIPLUS S7-1500 CPU 1516F-3 PN/DPSIMATIC S7-1500 CPU 1516T-3 PN/DPSIMATIC S7-1500 CPU 1518TF-4 PN/DPSIPLUS S7-1500 CPU 1515R-2 PN TX RAILSIMATIC S7-1500 CPU 1512SP-1 PNSIMATIC S7-1500 CPU 1518T-4 PN/DPSIMATIC S7-1500 CPU 1511-1 PNSIMATIC S7-1500 CPU 1517T-3 PN/DPSIPLUS S7-1500 CPU 1518HF-4 PNSIPLUS S7-1500 CPU 1513-1 PNSIPLUS S7-1500 CPU 1515R-2 PNSIMATIC S7-1500 CPU 1513F-1 PNSIMATIC S7-1500 CPU 1510SP F-1 PNSIPLUS S7-1500 CPU 1515F-2 PN RAILSIPLUS TIM 1531 IRCSIMATIC S7-1500 CPU 1511F-1 PNSIMATIC S7-1500 CPU 1516F-3 PN/DPSIPLUS ET 200SP CPU 1512SP-1 PNSIPLUS S7-1500 CPU 1511-1 PN T1 RAILSIPLUS S7-1500 CPU 1511-1 PNSIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL
CWE ID-CWE-1286
Improper Validation of Syntactic Correctness of Input
CWE ID-CWE-20
Improper Input Validation
CVE-2021-44693
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-4.9||MEDIUM
EPSS-0.07% / 22.25%
||
7 Day CHG~0.00%
Published-13 Dec, 2022 | 00:00
Updated-21 Apr, 2025 | 13:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.

Action-Not Available
Vendor-Siemens AG
Product-simatic_s7-1500_cpu_1507ssimatic_s7-1200_cpu_12_1214fcsimatic_s7-1500_cpu_cpu_1513pro-2simatic_s7-1500_cpu_1511csimatic_s7-1500_cpu_1511t-1_firmwaresimatic_s7-1500_cpu_1512sp-1siplus_s7-300_cpu_314siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmwaresimatic_et_200_sp_open_controller_cpu_1515sp_pc_firmwaresimatic_s7-1200_cpu_12_1214c_firmwaresimatic_s7-1200_cpu_12_1211csimatic_s7-1500_cpu_1508s_f_firmwaresimatic_s7-1500_cpu_1510sp-1simatic_s7-1200_cpu_1212csimatic_s7-1500_cpu_1512spf-1simatic_s7-1500_cpu_1513-1simatic_s7-1200_cpu_1212fc_firmwaresimatic_s7-1500_cpu_1517-3_pnsimatic_s7-1500_cpu_1515-2_pn_firmwaresimatic_s7-1500_cpu_1517f-3_pn\/dpsimatic_s7-1500_cpu_1513r-1simatic_s7-1200_cpu_1215_fcsimatic_s7-1500_cpu_1512c_firmwaresimatic_s7-1500_cpu_1517f-3_pn\/dp_firmwaresimatic_s7-1200_cpu_12_1215csimatic_s7-1500_cpu_1511-1_firmwaresimatic_s7-1500_cpu_1511-1_pnsimatic_s7-1500_cpu_1517f-3_firmwaresimatic_s7-1500_cpu_1518f-4_pn\/dp_firmwaresimatic_s7-1500_cpu_1518hf-4simatic_s7-1500_cpu_1518-4_pn_firmwaresiplus_tim_1531_irc_firmwaresimatic_s7-1500_cpu_1518-4_dp_firmwaresimatic_s7-1500_cpu_1516tf-3_firmwaresimatic_s7-1500_cpu_1511f-1_pn_firmwaresimatic_s7-1500_cpu_1516-3_firmwaresimatic_s7-1500_cpu_1518-4_pn\/dp_mfp_firmwaresimatic_s7-1500_cpu_1517-3_pn\/dpsimatic_s7-1500_cpu_1517-3simatic_s7-1500_cpu_1518t-4_firmwaresimatic_s7-1500_cpu_1508s_fsimatic_s7-1500_cpu_15prof-2_firmwaresimatic_s7-1500_cpu_1513f-1_pnsimatic_s7-1200_cpu_1214c_firmwaresimatic_s7-1500_cpu_1517-3_pn_firmwaresimatic_s7-1500_cpu_1517-3_dpsimatic_s7-1200_cpu_12_1214csimatic_s7-1200_cpu_1211c_firmwaresimatic_s7-1500_cpu_cpu_1513pro-2_firmwaresimatic_s7-1200_cpu_1214csiplus_tim_1531_ircsimatic_s7-1500_cpu_15prof-2simatic_s7-1500_cpu_1516tf-3siplus_s7-300_cpu_315-2_pn\/dp_firmwaresimatic_s7-1500_cpu_1516f-3_pn\/dp_firmwaresimatic_s7-1500_cpu_151511f-1_firmwaresimatic_s7-1500_cpu_1507s_f_firmwaresimatic_s7-1500_cpu_1516t-3_firmwaresimatic_s7-1500_cpu_1511t-1simatic_s7-1500_cpu_1517tf-3simatic_s7-1500_cpu_1515-2_pnsimatic_s7-1200_cpu_1214_fcsimatic_s7-1500_cpu_1515-2_firmwaresimatic_s7-1500_cpu_1516pro-2_firmwaretim_1531_irc_firmwaresimatic_s7-1500_cpu_1515-2simatic_s7-1500_cpu_1516-3_pnsimatic_s7-1500_cpu_1516pro_f_firmwaresimatic_s7-1500_cpu_1516-3simatic_s7-1200_cpu_1214fcsimatic_s7-1500_cpu_1518f-4_pn\/dpsimatic_s7-1500_cpu_1508s_firmwaresimatic_s7-1500_cpu_1511f-1_firmwaresimatic_s7-1200_cpu_12_1212fcsimatic_s7-1500_cpu_151511c-1simatic_s7-1500_cpu_1518tf-4_firmwaresiplus_s7-1200_cp_1243-1simatic_s7-1500_cpu_1511f-1_pnsimatic_s7-1500_cpu_1507s_fsiplus_s7-300_cpu_315-2_dpsimatic_s7-1500_cpu_1518simatic_s7-1500_cpu_1513-1_pn_firmwaresimatic_s7-1200_cpu_1215fcsimatic_s7-1500_cpu_1518f-4simatic_s7-1500_cpu_1516pro_fsimatic_s7-1500_cpu_1513r-1_firmwaresimatic_et_200_sp_open_controller_cpu_1515sp_pcsimatic_s7-1500_cpu_1512c-1_firmwaresimatic_s7-1500_cpu_1513f-1_pn_firmwaresiplus_et_200sp_cp_1543sp-1_isec_firmwaresimatic_s7-1500_cpu_1518_firmwaresimatic_s7-1500_cpu_1518-4_firmwaresimatic_s7-1500_cpu_1518tf-4simatic_s7-1200_cpu_1214_fc_firmwaresiplus_s7-1200_cp_1243-1_railsimatic_s7-1500_cpu_1516t-3simatic_s7-1500_cpu_1510sp_firmwaresimatic_s7-1500_cpu_1518-4_pn\/dp_mfpsiplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmwaresimatic_s7-1200_cpu_1215_fc_firmwaresimatic_s7-1200_cpu_12_1215fc_firmwaresimatic_s7-1500_cpu_1515t-2simatic_s7-1500_cpu_15pro-2simatic_s7-1500_cpu_1518-4_pnsimatic_s7-1200_cpu_12_1212c_firmwaresimatic_s7-1200_cpu_12_1212fc_firmwaresimatic_s7-1500_cpu_1511-1_pn_firmwaresimatic_s7-1500_cpu_15pro-2_firmwaresimatic_s7-1500_cpu_1515tf-2_firmwaretim_1531_ircsimatic_s7-1500_cpu_151511c-1_firmwaresimatic_s7-1200_cpu_12_1217csimatic_s7-1500_cpu_1518-4_pn\/dp_firmwaresimatic_s7-1500_cpu_1510spsimatic_s7-1200_cpu_12_1217c_firmwaresimatic_s7-1500_cpu_1518f-4_firmwaresimatic_s7-1200_cpu_1217csimatic_s7-1500_cpu_151511f-1simatic_s7-1500_software_controller_firmwaresimatic_s7-1500_cpu_1511-1simatic_s7-1500_cpu_1518-4_dpsiplus_s7-300_cpu_317-2_pn\/dp_firmwaresimatic_s7-1200_cpu_1215c_firmwaresimatic_s7-1500_cpu_1513-1_pnsimatic_s7-1200_cpu_1212c_firmwaresimatic_s7-1500_cpu_1515f-2_firmwaresimatic_s7-1200_cpu_1217c_firmwaresimatic_s7-1200_cpu_1214fc_firmwaresimatic_s7-1500_cpu_cpu_1513prof-2_firmwaresimatic_s7-1200_cpu_1215csimatic_s7-1500_cpu_1515r-2simatic_s7-1200_cpu_12_1215fcsiplus_et_200sp_cp_1543sp-1_isecsimatic_s7-1500_cpu_1513f-1simatic_s7-1500_cpu_1512csimatic_s7-1500_cpu_1516f-3_pn\/dpsimatic_s7-1500_cpu_1511c-1simatic_s7-1500_cpu_1517f-3simatic_s7-1500_cpu_1512spf-1_firmwaresiplus_s7-300_cpu_314_firmwaresiplus_et_200sp_cp_1543sp-1_isec_tx_railsimatic_s7-1500_cpu_1517tf-3_firmwaresimatic_s7-1500_cpu_1516f-3_firmwaresimatic_s7-1500_cpu_1517-3_firmwaresimatic_s7-1200_cpu_12_1214fc_firmwaresimatic_s7-1500_software_controllersimatic_s7-1500_cpu_1511c-1_firmwaresimatic_s7-1500_cpu_1517-3_dp_firmwaresimatic_s7-1500_cpu_1516-3_pn\/dp_firmwaresimatic_s7-1500_cpu_1518hf-4_firmwaresimatic_s7-1200_cpu_12_1212csiplus_s7-300_cpu_315-2_pn\/dpsimatic_s7-1500_cpu_1511f-1siplus_s7-300_cpu_317-2_pn\/dpsimatic_s7-1500_cpu_1515tf-2siplus_s7-1200_cp_1243-1_rail_firmwaresimatic_s7-1500_cpu_1511c_firmwaresimatic_s7-1500_cpu_1511tf-1simatic_s7-1500_cpu_1518-4simatic_s7-1500_cpu_1518-4_pn\/dpsiplus_s7-1200_cp_1243-1_firmwaresimatic_s7-1500_cpu_1511tf-1_firmwaresimatic_s7-1500_cpu_1517-3_pn\/dp_firmwaresimatic_s7-1500_cpu_1516-3_dpsimatic_s7-1500_cpu_1508ssiplus_s7-300_cpu_315-2_dp_firmwaresimatic_s7-plcsim_advanced_firmwaresimatic_s7-1500_cpu_1510sp-1_firmwaresimatic_s7-1500_cpu_1516-3_pn\/dpsimatic_s7-1500_cpu_1515f-2_pn_firmwaresimatic_s7-1500_cpu_1515t-2_firmwaresiplus_et_200sp_cp_1542sp-1_irc_tx_railsimatic_s7-1500_cpu_1516-3_dp_firmwaresimatic_s7-1200_cpu_12_1215c_firmwaresimatic_s7-1500_cpu_1512sp-1_firmwaresimatic_s7-1200_cpu_1215fc_firmwaresimatic_s7-1500_cpu_1512c-1simatic_s7-1500_cpu_1515f-2simatic_s7-1500_cpu_cpu_1513prof-2simatic_s7-1500_cpu_1515f-2_pnsimatic_s7-1200_cpu_1211csimatic_s7-1500_cpu_1516f-3simatic_s7-1500_cpu_1516-3_pn_firmwaresimatic_s7-1200_cpu_12_1211c_firmwaresimatic_s7-plcsim_advancedsimatic_s7-1500_cpu_1513f-1_firmwaresimatic_s7-1200_cpu_1212fcsimatic_s7-1500_cpu_1516pro-2simatic_s7-1500_cpu_1515r-2_firmwaresimatic_s7-1500_cpu_1507s_firmwaresimatic_s7-1500_cpu_1513-1_firmwaresimatic_s7-1500_cpu_1518t-4SIMATIC S7-1500 CPU 1512C-1 PNSIMATIC S7-1500 CPU 1517F-3 PN/DPSIMATIC S7-1500 CPU 1515-2 PNSIMATIC S7-1500 CPU 1511T-1 PNSIPLUS S7-1500 CPU 1518-4 PN/DPSIPLUS S7-1500 CPU 1518F-4 PN/DPSIPLUS S7-1500 CPU 1518-4 PN/DP MFPSIMATIC S7-1500 CPU 1515TF-2 PNSIMATIC S7-1500 CPU 1510SP-1 PNSIMATIC S7-1500 CPU 1516-3 PN/DPSIMATIC S7-1500 CPU 1511TF-1 PNSIPLUS S7-1500 CPU 1515F-2 PNSIPLUS S7-1500 CPU 1517H-3 PNSIPLUS ET 200SP CPU 1510SP F-1 PN RAILSIMATIC S7-1500 CPU 1518HF-4 PNSIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PNSIPLUS ET 200SP CPU 1512SP-1 PN RAILSIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PNSIPLUS ET 200SP CPU 1510SP-1 PN RAILSIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PNSIMATIC S7-PLCSIM AdvancedSIMATIC S7-1500 CPU 1517-3 PN/DPSIMATIC S7-1500 CPU 1517H-3 PNSIMATIC S7-1500 CPU 1516TF-3 PN/DPSIMATIC S7-1500 CPU 1515T-2 PNSIMATIC S7-1500 CPU S7-1518-4 PN/DP ODKSIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PNSIPLUS S7-1500 CPU 1516-3 PN/DP RAILSIPLUS S7-1500 CPU 1516-3 PN/DP TX RAILSIMATIC S7-1500 CPU 1511C-1 PNSIMATIC S7-1500 CPU 1517TF-3 PN/DPSIMATIC S7-1200 CPU family (incl. SIPLUS variants)SIPLUS S7-1500 CPU 1515F-2 PN T2 RAILSIPLUS S7-1500 CPU 1511-1 PN TX RAILSIPLUS S7-1500 CPU 1513F-1 PNSIMATIC Drive Controller CPU 1507D TFSIMATIC Drive Controller CPU 1504D TFSIMATIC S7-1500 CPU 1513R-1 PNSIPLUS S7-1500 CPU 1516-3 PN/DPSIMATIC S7-1500 CPU 1515R-2 PNSIMATIC S7-1500 CPU 1512SP F-1 PNTIM 1531 IRCSIPLUS S7-1500 CPU 1511F-1 PNSIPLUS ET 200SP CPU 1512SP F-1 PN RAILSIMATIC S7-1500 Software Controller V2SIMATIC S7-1500 CPU 1518F-4 PN/DP MFPSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)SIPLUS ET 200SP CPU 1512SP F-1 PNSIMATIC S7-1500 CPU 1515F-2 PNSIMATIC S7-1500 CPU 1518-4 PN/DPSIMATIC S7-1500 CPU 1513-1 PNSIPLUS ET 200SP CPU 1510SP F-1 PNSIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODKSIMATIC S7-1500 CPU 1518F-4 PN/DPSIMATIC S7-1500 CPU 1518-4 PN/DP MFPSIPLUS ET 200SP CPU 1510SP-1 PNSIPLUS S7-1500 CPU 1516F-3 PN/DPSIMATIC S7-1500 CPU 1516T-3 PN/DPSIMATIC S7-1500 CPU 1518TF-4 PN/DPSIPLUS S7-1500 CPU 1515R-2 PN TX RAILSIMATIC S7-1500 CPU 1512SP-1 PNSIMATIC S7-1500 CPU 1518T-4 PN/DPSIMATIC S7-1500 CPU 1511-1 PNSIMATIC S7-1500 CPU 1517T-3 PN/DPSIPLUS S7-1500 CPU 1518HF-4 PNSIPLUS S7-1500 CPU 1513-1 PNSIPLUS S7-1500 CPU 1515R-2 PNSIMATIC S7-1500 CPU 1513F-1 PNSIMATIC S7-1500 CPU 1510SP F-1 PNSIPLUS S7-1500 CPU 1515F-2 PN RAILSIPLUS TIM 1531 IRCSIMATIC S7-1500 CPU 1511F-1 PNSIMATIC S7-1500 CPU 1516F-3 PN/DPSIPLUS ET 200SP CPU 1512SP-1 PNSIPLUS S7-1500 CPU 1511-1 PN T1 RAILSIPLUS S7-1500 CPU 1511-1 PNSIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL
CWE ID-CWE-1284
Improper Validation of Specified Quantity in Input
CVE-2023-46284
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.22% / 44.17%
||
7 Day CHG~0.00%
Published-12 Dec, 2023 | 11:27
Updated-14 Jan, 2025 | 10:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.

Action-Not Available
Vendor-Siemens AG
Product-sinumerik_integrate_runmyhmi_\/automotiveopcenter_qualitysimatic_pcs_neototally_integrated_automation_portalSIMATIC PCS neoTotally Integrated Automation Portal (TIA Portal) V18Opcenter Execution FoundationOpcenter QualityTotally Integrated Automation Portal (TIA Portal) V17Totally Integrated Automation Portal (TIA Portal) V16Totally Integrated Automation Portal (TIA Portal) V14Totally Integrated Automation Portal (TIA Portal) V15.1SINEC NMS
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-41990
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-2.89% / 85.78%
||
7 Day CHG~0.00%
Published-18 Oct, 2021 | 13:44
Updated-04 Aug, 2024 | 03:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The gmp plugin in strongSwan before 5.9.4 has a remote integer overflow via a crafted certificate with an RSASSA-PSS signature. For example, this can be triggered by an unrelated self-signed CA certificate sent by an initiator. Remote code execution cannot occur.

Action-Not Available
Vendor-strongswann/aDebian GNU/LinuxSiemens AGFedora Project
Product-6gk5876-4aa00-2da2_firmware6gk5812-1ba00-2aa26gk5856-2ea00-3aa16gk6108-4am00-2da26gk5876-4aa00-2da26gk5876-3aa02-2ba2_firmware6gk5816-1aa00-2aa2_firmware6gk5876-3aa02-2ea2_firmware6gk5876-4aa00-2ba26gk5826-2ab00-2ab26gk5856-2ea00-3aa1_firmware6gk5876-4aa00-2ba2_firmware6gk5812-1aa00-2aa2fedora6gk6108-4am00-2da2_firmware6gk5856-2ea00-3da1_firmware6gk5874-2aa00-2aa2_firmware6gk5804-0ap00-2aa2_firmware6gk5874-3aa00-2aa26gk5812-1aa00-2aa2_firmware6gk5816-1ba00-2aa26gk5826-2ab00-2ab2_firmware6gk5874-2aa00-2aa26gk6108-4am00-2ba26gk5615-0aa00-2aa26gk5856-2ea00-3da1strongswan6gk5816-1ba00-2aa2_firmware6gk5874-3aa00-2aa2_firmware6gk5804-0ap00-2aa26gk5876-3aa02-2ea2debian_linux6gk6108-4am00-2ba2_firmware6gk5876-3aa02-2ba26gk5812-1ba00-2aa2_firmware6gk5615-0aa00-2aa2_firmware6gk5816-1aa00-2aa2n/a
CWE ID-CWE-190
Integer Overflow or Wraparound
CVE-2023-46283
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.22% / 44.17%
||
7 Day CHG~0.00%
Published-12 Dec, 2023 | 11:27
Updated-14 Jan, 2025 | 10:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.

Action-Not Available
Vendor-Siemens AG
Product-sinumerik_integrate_runmyhmi_\/automotiveopcenter_qualitysimatic_pcs_neototally_integrated_automation_portalSIMATIC PCS neoTotally Integrated Automation Portal (TIA Portal) V18Opcenter Execution FoundationOpcenter QualityTotally Integrated Automation Portal (TIA Portal) V17Totally Integrated Automation Portal (TIA Portal) V16Totally Integrated Automation Portal (TIA Portal) V14Totally Integrated Automation Portal (TIA Portal) V15.1SINEC NMS
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2021-41546
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.55% / 67.01%
||
7 Day CHG~0.00%
Published-12 Oct, 2021 | 09:49
Updated-04 Aug, 2024 | 03:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). Affected devices write crashdumps without checking if enough space is available on the filesystem. Once the crashdump fills the entire root filesystem, affected devices fail to boot successfully. An attacker can leverage this vulnerability to cause a permanent Denial-of-Service.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rox_rx1511ruggedcom_rox_rx1512ruggedcom_rox_mx5000_firmwareruggedcom_rox_rx5000_firmwareruggedcom_rox_rx1511_firmwareruggedcom_rox_rx1510ruggedcom_rox_rx1400_firmwareruggedcom_rox_rx1500_firmwareruggedcom_rox_rx1400ruggedcom_rox_rx1510_firmwareruggedcom_rox_rx1500ruggedcom_rox_rx1524_firmwareruggedcom_rox_rx5000ruggedcom_rox_rx1501ruggedcom_rox_rx1536ruggedcom_rox_mx5000ruggedcom_rox_rx1524ruggedcom_rox_rx1536_firmwareruggedcom_rox_rx1501_firmwareruggedcom_rox_rx1512_firmwareRUGGEDCOM ROX RX1511RUGGEDCOM ROX RX1536RUGGEDCOM ROX RX1400RUGGEDCOM ROX RX1500RUGGEDCOM ROX RX1501RUGGEDCOM ROX RX5000RUGGEDCOM ROX MX5000RUGGEDCOM ROX RX1524RUGGEDCOM ROX RX1510RUGGEDCOM ROX RX1512
CWE ID-CWE-400
Uncontrolled Resource Consumption
CWE ID-CWE-770
Allocation of Resources Without Limits or Throttling
CVE-2013-2780
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.34% / 56.13%
||
7 Day CHG~0.00%
Published-22 Apr, 2013 | 01:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port).

Action-Not Available
Vendor-n/aSiemens AG
Product-simatic_s7-1200_cpu_1215csimatic_s7-1200_cpu_1214_fc_firmwaresimatic_s7-1200_cpu_1214csimatic_s7-1200_cpu_1212csimatic_s7-1200_cpu_1214_fcsimatic_s7-1200_cpu_1212fc_firmwaresimatic_s7-1200_cpu_1215c_firmwaresimatic_s7-1200_cpu_1217csimatic_s7-1200_firmwaresimatic_s7-1200_cpu_1211c_firmwaresimatic_s7-1200_cpu_1215_fcsimatic_s7-1200_cpu_1212c_firmwaresimatic_s7-1200_cpu_1211csimatic_s7-1200_cpu_1212fcsimatic_s7-1200_cpu_1215_fc_firmwaresimatic_s7-1200_cpu_1214c_firmwaresimatic_s7-1200_cpu_1217c_firmwaresimatic_s7-1200n/a
CVE-2021-40368
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.44% / 62.46%
||
7 Day CHG~0.00%
Published-12 Apr, 2022 | 09:07
Updated-21 Apr, 2025 | 13:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-2 DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.10), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) (All versions < V10.1), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions < V8.2.3), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Affected devices improperly handle specially crafted packets sent to port 102/tcp. This could allow an attacker to create a Denial-of-Service condition. A restart is needed to restore normal operations.

Action-Not Available
Vendor-Siemens AG
Product-simatic_s7-400_pn\/dp_v7_firmwaresimatic_s7-400h_v6simatic_s7-410_v10simatic_s7-400_pn\/dp_v7simatic_s7-410_v8simatic_s7-410_v8_firmwaresimatic_s7-410_v10_firmwaresimatic_s7-400h_v6_firmware SIMATIC S7-400 CPU 414-2 DP V7 SIMATIC S7-400 CPU 414F-3 PN/DP V7 SIMATIC S7-400 CPU 414-3 DP V7 SIMATIC S7-400 CPU 416F-3 PN/DP V7 SIMATIC S7-400 CPU 416-2 DP V7 SIMATIC S7-400 CPU 412-2 DP V7 SIMATIC S7-400 CPU 414-3 PN/DP V7SIPLUS S7-400 CPU 414-3 PN/DP V7SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) SIMATIC S7-400 CPU 416F-2 DP V7SIPLUS S7-400 CPU 417-4 V7SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) SIMATIC S7-400 CPU 412-2 PN/DP V7 SIMATIC S7-400 CPU 416-3 PN/DP V7SIPLUS S7-400 CPU 416-3 PN/DP V7 SIMATIC S7-400 CPU 412-1 DP V7 SIMATIC S7-400 CPU 416-3 DP V7 SIMATIC S7-400 CPU 417-4 DP V7SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)SIPLUS S7-400 CPU 416-3 V7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2013-0700
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.34% / 56.13%
||
7 Day CHG~0.00%
Published-22 Apr, 2013 | 01:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port).

Action-Not Available
Vendor-n/aSiemens AG
Product-simatic_s7-1200_cpu_1215csimatic_s7-1200_cpu_1214_fc_firmwaresimatic_s7-1200_cpu_1214csimatic_s7-1200_cpu_1212csimatic_s7-1200_cpu_1214_fcsimatic_s7-1200_cpu_1212fc_firmwaresimatic_s7-1200_cpu_1215c_firmwaresimatic_s7-1200_cpu_1217csimatic_s7-1200_firmwaresimatic_s7-1200_cpu_1211c_firmwaresimatic_s7-1200_cpu_1215_fcsimatic_s7-1200_cpu_1212c_firmwaresimatic_s7-1200_cpu_1211csimatic_s7-1200_cpu_1212fcsimatic_s7-1200_cpu_1215_fc_firmwaresimatic_s7-1200_cpu_1214c_firmwaresimatic_s7-1200_cpu_1217c_firmwaresimatic_s7-1200n/a
CVE-2021-40142
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.59% / 68.14%
||
7 Day CHG~0.00%
Published-27 Aug, 2021 | 06:51
Updated-04 Aug, 2024 | 02:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer.

Action-Not Available
Vendor-opcfoundationn/aSiemens AG
Product-telecontrol_server_basicsimatic_wincc_runtimesimatic_winccsimatic_process_historian_opc_ua_server_firmwaresimatic_wincc_unified_scada_runtimesimatic_process_historian_opc_ua_serverlocal_discover_serversimatic_net_pcn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-37182
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.35% / 56.41%
||
7 Day CHG~0.00%
Published-14 Jun, 2022 | 09:21
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE XM408-4C (All versions < V6.5), SCALANCE XM408-4C (L3 int.) (All versions < V6.5), SCALANCE XM408-8C (All versions < V6.5), SCALANCE XM408-8C (L3 int.) (All versions < V6.5), SCALANCE XM416-4C (All versions < V6.5), SCALANCE XM416-4C (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 1x230V (All versions < V6.5), SCALANCE XR524-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 24V (All versions < V6.5), SCALANCE XR524-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 2x230V (All versions < V6.5), SCALANCE XR524-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 1x230V (All versions < V6.5), SCALANCE XR526-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 24V (All versions < V6.5), SCALANCE XR526-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 2x230V (All versions < V6.5), SCALANCE XR526-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR528-6M (All versions < V6.5), SCALANCE XR528-6M (2HR2) (All versions < V6.5), SCALANCE XR528-6M (2HR2, L3 int.) (All versions < V6.5), SCALANCE XR528-6M (L3 int.) (All versions < V6.5), SCALANCE XR552-12M (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2, L3 int.) (All versions < V6.5). The OSPF protocol implementation in affected devices fails to verify the checksum and length fields in the OSPF LS Update messages. An unauthenticated remote attacker could exploit this vulnerability to cause interruptions in the network by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device.

Action-Not Available
Vendor-Siemens AG
Product-scalance_xm408-8cscalance_xr552-12m_2hr2_firmwarescalance_xr524-8c_l3_firmwarescalance_xr528-6mscalance_xm416-4cscalance_xm408-4c_firmwarescalance_xr552-12m_2hr2_l3_firmwarescalance_xm408-4c_l3_firmwarescalance_xr526-8c_l3scalance_xm408-8c_l3scalance_xr528-6m_2hr2_firmwarescalance_xr526-8c_l3_firmwarescalance_xr528-6m_2hr2scalance_xr528-6m_2hr2_l3_firmwarescalance_xm408-8c_firmwarescalance_xr528-6m_l3scalance_xr528-6m_firmwarescalance_xm416-4c_l3scalance_xr552-12m_2hr2_l3scalance_xm416-4c_firmwarescalance_xr524-8cscalance_xr528-6m_2hr2_l3scalance_xr552-12m_firmwarescalance_xr524-8c_firmwarescalance_xm408-4cscalance_xr552-12mscalance_xm416-4c_l3_firmwarescalance_xr526-8c_firmwarescalance_xm408-8c_l3_firmwarescalance_xr524-8c_l3scalance_xm408-4c_l3scalance_xr552-12m_2hr2scalance_xr526-8cscalance_xr528-6m_l3_firmwareSCALANCE XR526-8C, 1x230VSCALANCE XR528-6M (2HR2, L3 int.)SCALANCE XR524-8C, 24VSCALANCE XM408-4CSCALANCE XM416-4C (L3 int.)SCALANCE XR552-12M (2HR2)SCALANCE XR524-8C, 1x230V (L3 int.)SCALANCE XR524-8C, 2x230VSCALANCE XR526-8C, 24VSCALANCE XR528-6M (2HR2)SCALANCE XM416-4CSCALANCE XR526-8C, 1x230V (L3 int.)SCALANCE XR528-6M (L3 int.)SCALANCE XR552-12M (2HR2, L3 int.)SCALANCE XM408-8CSCALANCE XM408-4C (L3 int.)SCALANCE XM408-8C (L3 int.)SCALANCE XR524-8C, 2x230V (L3 int.)SCALANCE XR526-8C, 24V (L3 int.)SCALANCE XR526-8C, 2x230V (L3 int.)SCALANCE XR526-8C, 2x230VSCALANCE XR552-12MSCALANCE XR524-8C, 1x230VSCALANCE XR524-8C, 24V (L3 int.)SCALANCE XR528-6M
CWE ID-CWE-354
Improper Validation of Integrity Check Value
CVE-2021-37185
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-1.43% / 79.86%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:16
Updated-18 Apr, 2025 | 18:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.

Action-Not Available
Vendor-Siemens AG
Product-simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmwaresimatic_s7-1500_cpu_1516t-3simatic_s7-1500_cpu_1510sp_firmwaresimatic_s7-1500_cpu_cpu_1513pro-2simatic_s7-1500_cpu_1511t-1_firmwaresimatic_s7-1500_cpu_1512sp-1simatic_s7-1500_cpu_1510sp-1simatic_s7-1200_cpu_1212csimatic_s7-1500_cpu_1515t-2simatic_s7-1500_cpu_1512spf-1simatic_drive_controller_cpu_1507d_tf_firmwaresimatic_s7-1500_cpu_1513-1simatic_s7-1500_cpu_1515tf-2_firmwaretim_1531_ircsimatic_s7-1200_cpu_1212fc_firmwaresimatic_s7-1500_cpu_1510spsimatic_s7-1500_cpu_1518f-4_firmwaresimatic_s7-1200_cpu_1217csimatic_s7-1500_cpu_1513r-1simatic_s7-1500_cpu_1511-1simatic_s7-1200_cpu_1215c_firmwaresimatic_s7-1500_cpu_1517f-3_firmwaresimatic_s7-1500_cpu_1511-1_firmwaresimatic_s7-1500_cpu_1518tf-4simatic_s7-1200_cpu_1212c_firmwaresimatic_s7-1500_cpu_1515f-2_firmwaresimatic_s7-1200_cpu_1217c_firmwaresimatic_s7-1500_cpu_1518hf-4simatic_s7-1200_cpu_1214fc_firmwaresimatic_s7-1500_cpu_cpu_1513prof-2_firmwaresimatic_s7-1200_cpu_1215csimatic_s7-1500_cpu_1515r-2simatic_s7-1500_cpu_1516tf-3_firmwaresimatic_s7-1500_cpu_1516-3_firmwaresimatic_s7-1500_cpu_1513f-1simatic_s7-1500_cpu_1511c-1simatic_s7-1500_cpu_1517-3simatic_s7-1500_cpu_1518t-4_firmwaresimatic_s7-1500_cpu_1517f-3simatic_s7-1500_cpu_1512spf-1_firmwaresimatic_s7-1200_cpu_1214c_firmwaresimatic_s7-1500_cpu_1517tf-3_firmwaresimatic_s7-1500_cpu_1516f-3_firmwaresimatic_s7-1500_cpu_cpu_1513pro-2_firmwaresimatic_s7-1200_cpu_1211c_firmwaresimatic_s7-1500_cpu_1517-3_firmwaresimatic_s7-1200_cpu_1214csimatic_s7-1500_software_controllersimatic_s7-1500_cpu_1516tf-3simatic_s7-1500_cpu_1511c-1_firmwaresimatic_s7-1500_cpu_1516t-3_firmwaresimatic_s7-1500_cpu_1518hf-4_firmwaresimatic_s7-1500_cpu_1511t-1simatic_drive_controller_cpu_1504d_tf_firmwaresimatic_s7-1500_cpu_1517tf-3simatic_s7-1500_cpu_1511f-1simatic_s7-1500_cpu_1515tf-2tim_1531_irc_firmwaresimatic_s7-1500_cpu_1515-2_firmwaresimatic_s7-1500_cpu_1516pro-2_firmwaresimatic_s7-1500_cpu_1511tf-1simatic_s7-1500_cpu_1515-2simatic_s7-1500_cpu_1518-4simatic_s7-1500_cpu_1511tf-1_firmwaresimatic_s7-1500_cpu_1516pro_f_firmwaresimatic_s7-plcsim_advanced_firmwaresimatic_s7-1500_cpu_1510sp-1_firmwaresimatic_s7-1500_cpu_1516-3simatic_s7-1200_cpu_1214fcsimatic_s7-1500_cpu_1515t-2_firmwaresimatic_drive_controller_cpu_1504d_tfsimatic_drive_controller_cpu_1507d_tfsimatic_s7-1500_cpu_1511f-1_firmwaresimatic_s7-1500_cpu_1518tf-4_firmwaresimatic_s7-1500_cpu_1512sp-1_firmwaresimatic_s7-1200_cpu_1215fc_firmwaresimatic_s7-1500_cpu_1512c-1simatic_s7-1500_cpu_cpu_1513prof-2simatic_s7-1500_cpu_1515f-2simatic_s7-1200_cpu_1211csimatic_s7-1500_cpu_1516f-3simatic_s7-1200_cpu_1215fcsimatic_s7-1500_cpu_1518f-4simatic_s7-1500_cpu_1516pro_fsimatic_s7-1500_cpu_1513r-1_firmwaresimatic_s7-1500_cpu_1512c-1_firmwaresimatic_s7-1500_cpu_1513f-1_firmwaresimatic_s7-1200_cpu_1212fcsimatic_s7-1500_cpu_1516pro-2simatic_s7-1500_cpu_1515r-2_firmwaresimatic_s7-plcsim_advancedsimatic_s7-1500_cpu_1513-1_firmwaresimatic_s7-1500_cpu_1518-4_firmwaresimatic_s7-1500_cpu_1518t-4simatic_et_200sp_open_controller_cpu_1515sp_pc2TIM 1531 IRCSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)SIMATIC S7-PLCSIM AdvancedSIMATIC Drive Controller familySIMATIC S7-1200 CPU family (incl. SIPLUS variants)SIMATIC S7-1500 Software ControllerSIPLUS TIM 1531 IRCSIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
CWE ID-CWE-672
Operation on a Resource after Expiration or Release
CVE-2021-37206
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.58% / 67.78%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Received webpackets are not properly processed. An unauthenticated remote attacker with access to any of the Ethernet interfaces could send specially crafted packets to force a restart of the target device.

Action-Not Available
Vendor-Siemens AG
Product-siprotec_5_with_cpu_variant_cp300siprotec_5_with_cpu_variant_cp100siprotec_5_with_cpu_variant_cp050SIPROTEC 5 relays with CPU variants CP050SIPROTEC 5 relays with CPU variants CP300SIPROTEC 5 relays with CPU variants CP100
CWE ID-CWE-20
Improper Input Validation
CVE-2012-3017
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.90% / 74.73%
||
7 Day CHG~0.00%
Published-31 Jul, 2012 | 10:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service (defect-mode transition and service outage) via (1) malformed HTTP traffic or (2) malformed IP packets.

Action-Not Available
Vendor-n/aSiemens AG
Product-simatic_s7-400_cpu_414-3_pn\/dpsimatic_s7-400_cpu_416f-3_pn\/dpsimatic_s7-400_cpu_firmwaresimatic_s7-400_cpu_416-3_pn\/dpn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-3749
Matching Score-8
Assigner-Protect AI (formerly huntr.dev)
ShareView Details
Matching Score-8
Assigner-Protect AI (formerly huntr.dev)
CVSS Score-7.5||HIGH
EPSS-8.37% / 91.93%
||
7 Day CHG-0.21%
Published-31 Aug, 2021 | 10:36
Updated-03 Aug, 2024 | 17:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Inefficient Regular Expression Complexity in axios/axios

axios is vulnerable to Inefficient Regular Expression Complexity

Action-Not Available
Vendor-axiosaxiosOracle CorporationSiemens AG
Product-sinec_insgoldengateaxiosaxios/axios
CWE ID-CWE-1333
Inefficient Regular Expression Complexity
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2021-37205
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-1.14% / 77.50%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:16
Updated-18 Apr, 2025 | 18:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.

Action-Not Available
Vendor-Siemens AG
Product-simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmwaresimatic_s7-1500_cpu_1516t-3simatic_s7-1500_cpu_1510sp_firmwaresimatic_s7-1500_cpu_cpu_1513pro-2simatic_s7-1500_cpu_1511t-1_firmwaresimatic_s7-1500_cpu_1512sp-1simatic_s7-1500_cpu_1510sp-1simatic_s7-1200_cpu_1212csimatic_s7-1500_cpu_1515t-2simatic_s7-1500_cpu_1512spf-1simatic_drive_controller_cpu_1507d_tf_firmwaresimatic_s7-1500_cpu_1513-1simatic_s7-1500_cpu_1515tf-2_firmwaretim_1531_ircsimatic_s7-1200_cpu_1212fc_firmwaresimatic_s7-1500_cpu_1510spsimatic_s7-1500_cpu_1518f-4_firmwaresimatic_s7-1200_cpu_1217csimatic_s7-1500_cpu_1513r-1simatic_s7-1500_cpu_1511-1simatic_s7-1200_cpu_1215c_firmwaresimatic_s7-1500_cpu_1517f-3_firmwaresimatic_s7-1500_cpu_1511-1_firmwaresimatic_s7-1500_cpu_1518tf-4simatic_s7-1200_cpu_1212c_firmwaresimatic_s7-1500_cpu_1515f-2_firmwaresimatic_s7-1200_cpu_1217c_firmwaresimatic_s7-1500_cpu_1518hf-4simatic_s7-1200_cpu_1214fc_firmwaresimatic_s7-1500_cpu_cpu_1513prof-2_firmwaresimatic_s7-1200_cpu_1215csimatic_s7-1500_cpu_1515r-2simatic_s7-1500_cpu_1516tf-3_firmwaresimatic_s7-1500_cpu_1516-3_firmwaresimatic_s7-1500_cpu_1513f-1simatic_s7-1500_cpu_1511c-1simatic_s7-1500_cpu_1517-3simatic_s7-1500_cpu_1518t-4_firmwaresimatic_s7-1500_cpu_1517f-3simatic_s7-1500_cpu_1512spf-1_firmwaresimatic_s7-1200_cpu_1214c_firmwaresimatic_s7-1500_cpu_1517tf-3_firmwaresimatic_s7-1500_cpu_1516f-3_firmwaresimatic_s7-1500_cpu_cpu_1513pro-2_firmwaresimatic_s7-1200_cpu_1211c_firmwaresimatic_s7-1500_cpu_1517-3_firmwaresimatic_s7-1200_cpu_1214csimatic_s7-1500_software_controllersimatic_s7-1500_cpu_1516tf-3simatic_s7-1500_cpu_1511c-1_firmwaresimatic_s7-1500_cpu_1516t-3_firmwaresimatic_s7-1500_cpu_1518hf-4_firmwaresimatic_s7-1500_cpu_1511t-1simatic_drive_controller_cpu_1504d_tf_firmwaresimatic_s7-1500_cpu_1517tf-3simatic_s7-1500_cpu_1511f-1simatic_s7-1500_cpu_1515tf-2tim_1531_irc_firmwaresimatic_s7-1500_cpu_1515-2_firmwaresimatic_s7-1500_cpu_1516pro-2_firmwaresimatic_s7-1500_cpu_1511tf-1simatic_s7-1500_cpu_1515-2simatic_s7-1500_cpu_1518-4simatic_s7-1500_cpu_1511tf-1_firmwaresimatic_s7-1500_cpu_1516pro_f_firmwaresimatic_s7-plcsim_advanced_firmwaresimatic_s7-1500_cpu_1510sp-1_firmwaresimatic_s7-1500_cpu_1516-3simatic_s7-1200_cpu_1214fcsimatic_s7-1500_cpu_1515t-2_firmwaresimatic_drive_controller_cpu_1504d_tfsimatic_drive_controller_cpu_1507d_tfsimatic_s7-1500_cpu_1511f-1_firmwaresimatic_s7-1500_cpu_1518tf-4_firmwaresimatic_s7-1500_cpu_1512sp-1_firmwaresimatic_s7-1200_cpu_1215fc_firmwaresimatic_s7-1500_cpu_1512c-1simatic_s7-1500_cpu_cpu_1513prof-2simatic_s7-1500_cpu_1515f-2simatic_s7-1200_cpu_1211csimatic_s7-1500_cpu_1516f-3simatic_s7-1200_cpu_1215fcsimatic_s7-1500_cpu_1518f-4simatic_s7-1500_cpu_1516pro_fsimatic_s7-1500_cpu_1513r-1_firmwaresimatic_s7-1500_cpu_1512c-1_firmwaresimatic_s7-1500_cpu_1513f-1_firmwaresimatic_s7-1200_cpu_1212fcsimatic_s7-1500_cpu_1516pro-2simatic_s7-1500_cpu_1515r-2_firmwaresimatic_s7-plcsim_advancedsimatic_s7-1500_cpu_1513-1_firmwaresimatic_s7-1500_cpu_1518-4_firmwaresimatic_s7-1500_cpu_1518t-4simatic_et_200sp_open_controller_cpu_1515sp_pc2TIM 1531 IRCSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)SIMATIC S7-PLCSIM AdvancedSIMATIC Drive Controller familySIMATIC S7-1200 CPU family (incl. SIPLUS variants)SIMATIC S7-1500 Software ControllerSIPLUS TIM 1531 IRCSIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
CWE ID-CWE-401
Missing Release of Memory after Effective Lifetime
CVE-2012-3016
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.90% / 74.73%
||
7 Day CHG~0.00%
Published-31 Jul, 2012 | 10:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service (defect-mode transition and service outage) via crafted ICMP packets.

Action-Not Available
Vendor-n/aSiemens AG
Product-simatic_s7-400_cpu_412-2_pnsimatic_s7-400_cpu_416-3_pn\/dpsimatic_s7-400_cpu_416f-3_pn\/dpsimatic_s7-400_cpu_414f-3_pn\/dpsimatic_s7-400_cpu_414-3_pn\/dpsimatic_s7-400_cpu_firmwaren/a
CVE-2024-37993
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.9||MEDIUM
EPSS-0.15% / 36.66%
||
7 Day CHG~0.00%
Published-10 Sep, 2024 | 09:36
Updated-18 Sep, 2024 | 15:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The affected applications do not authenticated the creation of Ajax2App instances. This could allow an unauthenticated attacker to cause a denial of service condition.

Action-Not Available
Vendor-Siemens AG
Product-simatic_reader_rf650r_fcc_firmwaresimatic_reader_rf680r_cmiitsimatic_rf1170r_firmwaresimatic_reader_rf650r_cmiit_firmwaresimatic_reader_rf685r_fccsimatic_reader_rf650r_aribsimatic_reader_rf615r_etsi_firmwaresimatic_rf360rsimatic_reader_rf680r_fccsimatic_reader_rf610r_fccsimatic_reader_rf610r_etsi_firmwaresimatic_reader_rf685r_arib_firmwaresimatic_reader_rf615r_cmiitsimatic_rf186c_firmwaresimatic_reader_rf685r_fcc_firmwaresimatic_rf188c_firmwaresimatic_reader_rf680r_cmiit_firmwaresimatic_reader_rf685r_etsisimatic_rf185csimatic_rf360r_firmwaresimatic_rf1140r_firmwaresimatic_rf186cisimatic_rf1140rsimatic_rf188csimatic_reader_rf610r_cmiit_firmwaresimatic_reader_rf610r_fcc_firmwaresimatic_rf185c_firmwaresimatic_reader_rf615r_fccsimatic_reader_rf680r_etsisimatic_reader_rf615r_fcc_firmwaresimatic_reader_rf680r_fcc_firmwaresimatic_reader_rf610r_etsisimatic_reader_rf685r_cmiit_firmwaresimatic_reader_rf680r_arib_firmwaresimatic_rf186ci_firmwaresimatic_rf166c_firmwaresimatic_rf188ci_firmwaresimatic_reader_rf650r_fccsimatic_reader_rf650r_cmiitsimatic_reader_rf685r_cmiitsimatic_rf166csimatic_reader_rf680r_aribsimatic_rf1170rsimatic_reader_rf650r_etsisimatic_reader_rf610r_cmiitsimatic_reader_rf650r_arib_firmwaresimatic_reader_rf680r_etsi_firmwaresimatic_reader_rf615r_etsisimatic_reader_rf650r_etsi_firmwaresimatic_rf186csimatic_reader_rf685r_aribsimatic_reader_rf615r_cmiit_firmwaresimatic_reader_rf685r_etsi_firmwaresimatic_rf188ciSIMATIC Reader RF650R ARIBSIMATIC Reader RF650R ETSISIMATIC Reader RF680R CMIITSIMATIC Reader RF615R ETSISIMATIC RF166CSIMATIC Reader RF685R CMIITSIMATIC RF185CSIMATIC Reader RF610R CMIITSIMATIC Reader RF685R ETSISIMATIC Reader RF615R CMIITSIMATIC RF188CISIMATIC Reader RF610R ETSISIMATIC Reader RF685R FCCSIMATIC Reader RF615R FCCSIMATIC RF186CSIMATIC RF360RSIMATIC Reader RF680R ARIBSIMATIC RF1140RSIMATIC Reader RF685R ARIBSIMATIC RF1170RSIMATIC Reader RF680R ETSISIMATIC RF188CSIMATIC Reader RF610R FCCSIMATIC Reader RF650R CMIITSIMATIC RF186CISIMATIC Reader RF680R FCCSIMATIC Reader RF650R FCC
CWE ID-CWE-284
Improper Access Control
CVE-2024-37992
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.9||MEDIUM
EPSS-0.23% / 45.46%
||
7 Day CHG~0.00%
Published-10 Sep, 2024 | 09:36
Updated-18 Sep, 2024 | 15:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The affected devices does not properly handle the error in case of exceeding characters while setting SNMP leading to the restart of the application.

Action-Not Available
Vendor-Siemens AG
Product-simatic_reader_rf650r_fcc_firmwaresimatic_reader_rf680r_cmiitsimatic_rf1170r_firmwaresimatic_reader_rf650r_cmiit_firmwaresimatic_reader_rf685r_fccsimatic_reader_rf650r_aribsimatic_reader_rf615r_etsi_firmwaresimatic_rf360rsimatic_reader_rf680r_fccsimatic_reader_rf610r_fccsimatic_reader_rf610r_etsi_firmwaresimatic_reader_rf685r_arib_firmwaresimatic_reader_rf615r_cmiitsimatic_rf186c_firmwaresimatic_reader_rf685r_fcc_firmwaresimatic_rf188c_firmwaresimatic_reader_rf680r_cmiit_firmwaresimatic_reader_rf685r_etsisimatic_rf185csimatic_rf360r_firmwaresimatic_rf1140r_firmwaresimatic_rf186cisimatic_rf1140rsimatic_rf188csimatic_reader_rf610r_cmiit_firmwaresimatic_reader_rf610r_fcc_firmwaresimatic_rf185c_firmwaresimatic_reader_rf615r_fccsimatic_reader_rf680r_etsisimatic_reader_rf615r_fcc_firmwaresimatic_reader_rf680r_fcc_firmwaresimatic_reader_rf610r_etsisimatic_reader_rf685r_cmiit_firmwaresimatic_reader_rf680r_arib_firmwaresimatic_rf186ci_firmwaresimatic_rf166c_firmwaresimatic_rf188ci_firmwaresimatic_reader_rf650r_fccsimatic_reader_rf650r_cmiitsimatic_reader_rf685r_cmiitsimatic_rf166csimatic_reader_rf680r_aribsimatic_rf1170rsimatic_reader_rf650r_etsisimatic_reader_rf610r_cmiitsimatic_reader_rf650r_arib_firmwaresimatic_reader_rf680r_etsi_firmwaresimatic_reader_rf615r_etsisimatic_reader_rf650r_etsi_firmwaresimatic_rf186csimatic_reader_rf685r_aribsimatic_reader_rf615r_cmiit_firmwaresimatic_reader_rf685r_etsi_firmwaresimatic_rf188ciSIMATIC Reader RF650R ARIBSIMATIC Reader RF650R ETSISIMATIC Reader RF680R CMIITSIMATIC Reader RF615R ETSISIMATIC RF166CSIMATIC Reader RF685R CMIITSIMATIC RF185CSIMATIC Reader RF610R CMIITSIMATIC Reader RF685R ETSISIMATIC Reader RF615R CMIITSIMATIC RF188CISIMATIC Reader RF610R ETSISIMATIC Reader RF685R FCCSIMATIC Reader RF615R FCCSIMATIC RF186CSIMATIC RF360RSIMATIC Reader RF680R ARIBSIMATIC RF1140RSIMATIC Reader RF685R ARIBSIMATIC RF1170RSIMATIC Reader RF680R ETSISIMATIC RF188CSIMATIC Reader RF610R FCCSIMATIC Reader RF650R CMIITSIMATIC RF186CISIMATIC Reader RF680R FCCSIMATIC Reader RF650R FCC
CWE ID-CWE-703
Improper Check or Handling of Exceptional Conditions
CVE-2021-34798
Matching Score-8
Assigner-Apache Software Foundation
ShareView Details
Matching Score-8
Assigner-Apache Software Foundation
CVSS Score-7.5||HIGH
EPSS-10.97% / 93.14%
||
7 Day CHG~0.00%
Published-16 Sep, 2021 | 14:40
Updated-04 Aug, 2024 | 00:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
NULL pointer dereference in httpd core

Malformed requests may cause the server to dereference a NULL pointer. This issue affects Apache HTTP Server 2.4.48 and earlier.

Action-Not Available
Vendor-NetApp, Inc.Debian GNU/LinuxThe Apache Software FoundationOracle CorporationTenable, Inc.Broadcom Inc.Siemens AGFedora Project
Product-peoplesoft_enterprise_peopletoolscommunications_cloud_native_core_network_function_cloud_native_environmentcloud_backuptenable.scstoragegridsinema_serverruggedcom_nmshttp_serverclustered_data_ontapdebian_linuxsinec_nmssinema_remote_connect_serverinstantis_enterprisetrackfedorazfs_storage_appliance_kitenterprise_manager_base_platformbrocade_fabric_operating_system_firmwareApache HTTP Server
CWE ID-CWE-476
NULL Pointer Dereference
CVE-2012-1802
Matching Score-8
Assigner-CERT/CC
ShareView Details
Matching Score-8
Assigner-CERT/CC
CVSS Score-7.8||HIGH
EPSS-3.89% / 87.78%
||
7 Day CHG~0.00%
Published-18 Apr, 2012 | 10:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.

Action-Not Available
Vendor-n/aSiemens AG
Product-scalance_x-300scalance_x414-3e_firmwarescalance_x414-3escalance_xr-300scalance_x-300eecscalance_xr-300_firmwarescalance_x-300_firmwarescalance_x-300eec_firmwarescalance_x308-2m_firmwarescalance_x308-2mn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-33720
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.44% / 62.46%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Specially crafted packets sent to port 4443/tcp could cause a Denial-of-Service condition.

Action-Not Available
Vendor-Siemens AG
Product-siprotec_5_with_cpu_variant_cp300siprotec_5_with_cpu_variant_cp100siprotec_5_with_cpu_variant_cp050SIPROTEC 5 relays with CPU variants CP050SIPROTEC 5 relays with CPU variants CP300SIPROTEC 5 relays with CPU variants CP100
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2021-33737
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.23% / 45.56%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 ERPC (All versions), SIMATIC CP 343-1 Lean (incl. SIPLUS variants) (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 Advanced (All versions < V3.3), SIPLUS NET CP 443-1 (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (All versions < V3.3). Sending a specially crafted packet to port 102/tcp of an affected device could cause a denial of service condition. A restart is needed to restore normal operations.

Action-Not Available
Vendor-Siemens AG
Product-simatic_cp_343-1_erpc_firmwaresimatic_cp_343-1_leansimatic_cp343-1_advancedsimatic_cp_443-1simatic_cp_443-1_advanced_firmwaresimatic_cp_343-1_erpcsimatic_cp_443-1_firmwaresimatic_cp_343-1_advanced_firmwaresimatic_cp343-1simatic_cp_343-1_lean_firmwaresimatic_cp_443-1_advancedsimatic_cp_343-1_firmwareSIMATIC CP 343-1 (incl. SIPLUS variants)SIMATIC CP 343-1 ERPCSIMATIC CP 443-1 AdvancedSIPLUS NET CP 443-1 AdvancedSIMATIC CP 343-1 Lean (incl. SIPLUS variants)SIMATIC CP 443-1SIPLUS NET CP 443-1SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-31890
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-2.50% / 84.72%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:32
Updated-11 Mar, 2025 | 09:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)

Action-Not Available
Vendor-Siemens AG
Product-nucleus_readystart_v3talon_tc_compactnucleus_nettalon_tc_compact_firmwareapogee_pxc_compactapogee_modular_equiment_controller_firmwareapogee_pxc_compact_firmwareapogee_modular_equiment_controllerapogee_modular_building_controllercapital_vstarapogee_pxc_modular_firmwareapogee_pxc_modularnucleus_readystart_v4talon_tc_modular_firmwaretalon_tc_modularapogee_modular_building_controller_firmwarenucleus_source_codePLUSCONTROL 1st GenSIMOTICS CONNECT 400Capital Embedded AR Classic 431-422Capital Embedded AR Classic R20-11
CWE ID-CWE-240
Improper Handling of Inconsistent Structural Elements
CVE-2021-31340
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.48% / 64.18%
||
7 Day CHG~0.00%
Published-08 Jun, 2021 | 19:47
Updated-03 Aug, 2024 | 22:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC RF166C (All versions > V1.1 and < V1.3.2), SIMATIC RF185C (All versions > V1.1 and < V1.3.2), SIMATIC RF186C (All versions > V1.1 and < V1.3.2), SIMATIC RF186CI (All versions > V1.1 and < V1.3.2), SIMATIC RF188C (All versions > V1.1 and < V1.3.2), SIMATIC RF188CI (All versions > V1.1 and < V1.3.2), SIMATIC RF360R (All versions < V2.0), SIMATIC Reader RF610R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF610R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF610R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF615R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF615R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF615R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF650R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF650R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF650R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF650R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF680R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF680R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF680R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF680R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF685R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF685R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF685R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF685R FCC (All versions > V3.0 < V4.0). Affected devices do not properly handle large numbers of incoming connections. An attacker may leverage this to cause a Denial-of-Service situation.

Action-Not Available
Vendor-Siemens AG
Product-simatic_reader_rf650r_fcc_firmwaresimatic_reader_rf650r_cmiit_firmwaresimatic_reader_rf680r_cmiitsimatic_reader_rf685r_fccsimatic_reader_rf610r_etsi_firmwaresimatic_reader_rf615r_etsi_firmwaresimatic_rf360rsimatic_reader_rf650r_aribsimatic_reader_rf610r_fccsimatic_reader_rf680r_fccsimatic_reader_rf685r_arib_firmwaresimatic_rf186c_firmwaresimatic_reader_rf615r_cmiitsimatic_rf188c_firmwaresimatic_reader_rf685r_fcc_firmwaresimatic_rf185csimatic_reader_rf680r_cmiit_firmwaresimatic_reader_rf685r_etsisimatic_rf360r_firmwaresimatic_rf186cisimatic_rf188csimatic_reader_rf610r_cmiit_firmwaresimatic_reader_rf610r_fcc_firmwaresimatic_rf185c_firmwaresimatic_reader_rf615r_fccsimatic_reader_rf615r_fcc_firmwaresimatic_reader_rf680r_etsisimatic_reader_rf680r_fcc_firmwaresimatic_reader_rf610r_etsisimatic_reader_rf680r_arib_firmwaresimatic_reader_rf685r_cmiit_firmwaresimatic_rf186ci_firmwaresimatic_rf166c_firmwaresimatic_rf188ci_firmwaresimatic_reader_rf650r_cmiitsimatic_reader_rf650r_fccsimatic_rf166csimatic_reader_rf685r_cmiitsimatic_reader_rf680r_aribsimatic_reader_rf650r_etsisimatic_reader_rf610r_cmiitsimatic_reader_rf650r_arib_firmwaresimatic_reader_rf680r_etsi_firmwaresimatic_reader_rf615r_etsisimatic_rf186csimatic_reader_rf650r_etsi_firmwaresimatic_reader_rf685r_aribsimatic_reader_rf615r_cmiit_firmwaresimatic_reader_rf685r_etsi_firmwaresimatic_rf188ciSIMATIC Reader RF650R ARIBSIMATIC Reader RF650R ETSISIMATIC Reader RF680R CMIITSIMATIC Reader RF615R ETSISIMATIC RF166CSIMATIC Reader RF685R CMIITSIMATIC RF185CSIMATIC Reader RF610R CMIITSIMATIC Reader RF685R ETSISIMATIC Reader RF615R CMIITSIMATIC RF188CISIMATIC Reader RF610R ETSISIMATIC Reader RF685R FCCSIMATIC Reader RF615R FCCSIMATIC RF186CSIMATIC RF360RSIMATIC Reader RF680R ARIBSIMATIC Reader RF685R ARIBSIMATIC RF188CSIMATIC Reader RF680R ETSISIMATIC Reader RF610R FCCSIMATIC Reader RF650R CMIITSIMATIC RF186CISIMATIC Reader RF680R FCCSIMATIC Reader RF650R FCC
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2024-34057
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.2||HIGH
EPSS-0.17% / 38.88%
||
7 Day CHG~0.00%
Published-18 Sep, 2024 | 00:00
Updated-25 Sep, 2024 | 17:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Triangle Microworks TMW IEC 61850 Client source code libraries before 12.2.0 lack a buffer size check when processing received messages. The resulting buffer overflow can cause a crash, resulting in a denial of service.

Action-Not Available
Vendor-trianglemicroworksn/atrianglemicroworksSiemens AG
Product-sicam_a8000sicam_s8000sicam_egs_firmwaresicam_sccsicam_scc_firmwareiec_61850_source_code_librarysitipe_atsicam_egssicam_a8000_firmwaren/aiec_61850_client_source_code_library
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2003-1464
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.72% / 71.56%
||
7 Day CHG~0.00%
Published-24 Oct, 2007 | 23:00
Updated-03 Apr, 2025 | 01:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer overflow in Siemens 45 series mobile phones allows remote attackers to cause a denial of service (disconnect and unavailable inbox) via a Short Message Service (SMS) message with a long image name.

Action-Not Available
Vendor-n/aSiemens AG
Product-s45m45n/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-27386
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.44% / 62.12%
||
7 Day CHG~0.00%
Published-12 May, 2021 | 13:18
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.

Action-Not Available
Vendor-Siemens AG
Product-simatic_hmi_ktp_mobile_panels_ktp900_firmwaresimatic_hmi_ktp_mobile_panels_ktp400fsinamics_gm150simatic_hmi_ktp_mobile_panels_ktp700f_firmwaresinamics_sm150isinamics_gl150_firmwaresinamics_gl150simatic_hmi_ktp_mobile_panels_ktp900f_firmwaresimatic_hmi_ktp_mobile_panels_ktp400f_firmwaresimatic_hmi_comfort_panels_4\"_firmwaresinamics_gm150_firmwaresinamics_sm150simatic_hmi_comfort_outdoor_panels_7\"_firmwaresinamics_gh150simatic_hmi_ktp_mobile_panels_ktp700_firmwaresinamics_gh150_firmwaresinamics_sl150simatic_hmi_comfort_panels_22\"simatic_hmi_ktp_mobile_panels_ktp700fsinamics_sh150sinamics_sm150_firmwaresimatic_hmi_ktp_mobile_panels_ktp900fsinamics_sh150_firmwaresimatic_hmi_comfort_outdoor_panels_7\"sinamics_sm120simatic_hmi_ktp_mobile_panels_ktp700simatic_hmi_comfort_outdoor_panels_15\"_firmwaresimatic_hmi_comfort_panels_4\"sinamics_sl150_firmwaresinamics_sm150i_firmwaresimatic_hmi_ktp_mobile_panels_ktp900simatic_hmi_comfort_outdoor_panels_15\"simatic_hmi_comfort_panels_22\"_firmwaresimatic_wincc_runtime_advancedsinamics_sm120_firmwareSIMATIC WinCC Runtime Advanced V16SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants)SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) SINAMICS SM150iSIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants)SINAMICS GH150SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900FSINAMICS GM150 (with option X30)SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F SINAMICS GL150 (with option X30)SINAMICS SH150SIMATIC WinCC Runtime Advanced V15SINAMICS SL150SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) SINAMICS SM120SINAMICS SM150
CWE ID-CWE-401
Missing Release of Memory after Effective Lifetime
CVE-2021-25215
Matching Score-8
Assigner-Internet Systems Consortium (ISC)
ShareView Details
Matching Score-8
Assigner-Internet Systems Consortium (ISC)
CVSS Score-7.5||HIGH
EPSS-1.68% / 81.43%
||
7 Day CHG+0.04%
Published-29 Apr, 2021 | 00:55
Updated-16 Sep, 2024 | 22:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
An assertion check can fail while answering queries for DNAME records that require the DNAME to be processed to resolve itself

In BIND 9.0.0 -> 9.11.29, 9.12.0 -> 9.16.13, and versions BIND 9.9.3-S1 -> 9.11.29-S1 and 9.16.8-S1 -> 9.16.13-S1 of BIND Supported Preview Edition, as well as release versions 9.17.0 -> 9.17.11 of the BIND 9.17 development branch, when a vulnerable version of named receives a query for a record triggering the flaw described above, the named process will terminate due to a failed assertion check. The vulnerability affects all currently maintained BIND 9 branches (9.11, 9.11-S, 9.16, 9.16-S, 9.17) as well as all other versions of BIND 9.

Action-Not Available
Vendor-Internet Systems Consortium, Inc.Debian GNU/LinuxNetApp, Inc.Oracle CorporationSiemens AGFedora Project
Product-h300e500f_firmwarea250_firmwareh500scloud_backuptekelec_platform_distributionh300s_firmwareactive_iq_unified_managerh410sh300sh300e_firmwaresinec_infrastructure_network_services500fdebian_linuxh500eh410s_firmwarefedorah500s_firmwareh500e_firmwareh700s_firmwarea250h700ebindh700e_firmwareh700sBIND9
CWE ID-CWE-617
Reachable Assertion
CVE-2019-18336
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.25% / 48.23%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 19:16
Updated-05 Aug, 2024 | 01:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-simatic_s7-300_cpu_313simatic_tdc_cpu555_firmwaresimatic_tdc_cp51m1_firmwaresimatic_s7-300_cpu_316-2_dp_firmwaresimatic_s7-300_cpu_314simatic_tdc_cp51m1simatic_s7-300_cpu_314_ifmsimatic_tdc_cpu555simatic_s7-300_cpu_312_ifmsimatic_s7-300_cpu_318-2_firmwaresimatic_s7-300_cpu_313_firmwaresimatic_s7-300_cpu_314_ifm_firmwaresimatic_s7-300_cpu_316-2_dpsimatic_s7-300_cpu_318-2simatic_s7-300_cpu_315-2_dpsimatic_s7-300_cpu_315_firmwaresimatic_s7-300_cpu_firmwaresimatic_s7-300_cpu_315-2_dp_firmwaresimatic_s7-300_cpu_315simatic_s7-300_cpu_312_ifm_firmwaresimatic_s7-300_cpusimatic_s7-300_cpu_314_firmwaresinumerik_840d_slSIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)SIMATIC TDC CPU555SIMATIC TDC CP51M1SINUMERIK 840D sl
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2021-25664
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.52% / 65.95%
||
7 Day CHG~0.00%
Published-22 Apr, 2021 | 20:42
Updated-11 Mar, 2025 | 10:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes the Hop-by-Hop extension header in IPv6 packets and its options lacks any checks against the length field of the header, allowing attackers to put the function into an infinite loop by supplying arbitrary length values.

Action-Not Available
Vendor-Siemens AG
Product-nucleus_readystart_v3nucleus_readystart_v4capital_vstarnucleus_netnucleus_source_codeNucleus Source CodeNucleus NETCapital Embedded AR Classic 431-422Capital Embedded AR Classic R20-11Nucleus ReadyStart V4Nucleus ReadyStart V3
CWE ID-CWE-835
Loop with Unreachable Exit Condition ('Infinite Loop')
CVE-2021-44221
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.54% / 66.58%
||
7 Day CHG~0.00%
Published-12 Jul, 2022 | 10:06
Updated-04 Aug, 2024 | 04:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC eaSie Core Package (All versions < V22.00). The affected systems do not properly validate input that is sent to the underlying message passing framework. This could allow an remote attacker to trigger a denial of service of the affected system.

Action-Not Available
Vendor-Siemens AG
Product-simatic_easie_core_packageSIMATIC eaSie Core Package
CWE ID-CWE-20
Improper Input Validation
CVE-2021-25659
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.44% / 62.46%
||
7 Day CHG~0.00%
Published-10 Aug, 2021 | 10:35
Updated-03 Aug, 2024 | 20:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Automation License Manager 5 (All versions), Automation License Manager 6 (All versions < V6.0 SP9 Update 2). Sending specially crafted packets to port 4410/tcp of an affected system could lead to extensive memory being consumed and as such could cause a denial-of-service preventing legitimate users from using the system.

Action-Not Available
Vendor-Siemens AG
Product-automation_license_managerAutomation License Manager 5Automation License Manager 6
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2017-12741
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-3.94% / 87.87%
||
7 Day CHG~0.00%
Published-26 Dec, 2017 | 04:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.

Action-Not Available
Vendor-Siemens AG
Product-sinamics_g150simotion_p_firmwaresinamics_dcm_firmwaresimatic_et_200m_firmwareek-ertec_200p_firmwaresimatic_winac_rtx_f_2010sinamics_g150_firmwaresimotion_dsinamics_v90pnsimatic_winac_rtx_f_2010_firmwaresimatic_s7-200simotion_csimatic_s7-300sinamics_g110m\/g120pndk_standard_ethernet_controllersimotion_psinamics_s150_v4.8sinamics_g130simatic_et_200alsimatic_et_200mp_firmwaresinumerik_840d_sl_firmwaresimatic_et_200ssimatic_s7-1500_firmwaresinamics_s150_v4.7_firmwaredk_standard_ethernet_controller_firmwaresinamics_s110pnsimatic_compact_field_unit_firmwaresimatic_s7-400h_v6_firmwaresinamics_dcpsirius_soft_starter_3rw44pnsimocode_pro_v_profinetsimatic_s7-1200_firmwaresinamics_s110pn_firmwaresimocode_pro_v_profinet_firmwareek-ertec_200psirius_soft_starter_3rw44pn_firmwaresimatic_et_200ecopnsinamics_dcmsimatic_s7-1200simotion_d_firmwaresinamics_s150_v4.7ek-ertec_200pn_iosinumerik_840d_slsimatic_s7-410_v8simatic_et_200ecopn_firmwaresimatic_pn\/pn_couplersimatic_s7-400h_v6simatic_s7-1500_controllersimatic_et_200sp_firmwaresimatic_s7-410_v8_firmwaresimatic_s7-1500simatic_et_200pro_firmwaresimatic_s7-1500_controller_firmwaresinamics_s150_v4.8_firmwaresinamics_s120simatic_et_200s_firmwaresimatic_s7-400pn_v6sinamics_s120_firmwaresimatic_s7-300_firmwaresinamics_g130_firmwaresimatic_et_200mpsimotion_c_firmwaresimatic_s7-400pn\/dp_v7simatic_et_200spsimatic_pn\/pn_coupler_firmwaresimatic_s7-200_firmwaresimatic_s7-400pn_v6_firmwaresimatic_et_200msimatic_et_200al_firmwaresimatic_compact_field_unitsinamics_g110m\/g120pn_firmwaresimatic_et_200prosinamics_v90pn_firmwaresinamics_dcp_firmwareek-ertec_200pn_io_firmwaresimatic_s7-400pn\/dp_v7_firmwareSIMOTION DSINAMICS GL150 V4.7 w. PROFINETSINAMICS S110 w. PNSINUMERIK 840D slSIMATIC PN/PN Coupler (incl. SIPLUS NET variants)SIMOTION P V5SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12SINAMICS SL150 V4.7.5 w. PROFINETSIMATIC ET200ecoPN, 4AO U/I 4xM12SIPLUS ET 200MP IM 155-5 PN HF T1 RAILSIMATIC ET 200SP IM 155-6 PN HFSINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)SIPLUS ET 200SP IM 155-6 PN HFSIMATIC ET 200SP IM 155-6 PN STSINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)SIMATIC ET 200SP IM 155-6 PN HSSIMATIC ET200ecoPN: IO-Link MasterSINAMICS SL150 V4.7.4 w. PROFINETSIMOCODE pro V PROFINET (incl. SIPLUS variants)SIMATIC ET 200SP IM 155-6 PN BASIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12SIPLUS ET 200SP IM 155-6 PN HF T1 RAILSIPLUS ET 200SP IM 155-6 PN ST TX RAILSINAMICS SL150 V4.7.0 w. PROFINETSIMATIC ET 200SP IM 155-6 PN ST BASINAMICS G150 V4.7 w. PNSIMATIC ET 200MP IM 155-5 PN HFSIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12SIMATIC ET 200pro IM 154-4 PN HFSIRIUS Soft Starter 3RW44 PNSINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)SIMATIC S7-1500 Software ControllerSIMATIC ET 200MP IM 155-5 PN STSIMATIC TDC CPU555SIMATIC ET200S (incl. SIPLUS variants)SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)SINAMICS G110M w. PNSIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12SIMOTION CSIMATIC TDC CP51M1SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12SIMATIC WinAC RTX 2010SIMATIC ET 200MP IM 155-5 PN BASIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)SIMATIC S7-1200 CPU family (incl. SIPLUS variants)SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12SINAMICS V90 w. PNDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200PSIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)SIPLUS ET 200SP IM 155-6 PN ST BASIMATIC ET 200pro IM 154-3 PN HFSIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)SINAMICS DCM w. PNSINAMICS G130 V4.8 w. PNDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet ControllerSIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12SINAMICS DCP w. PNSINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12SINAMICS GM150 V4.7 w. PROFINETSIPLUS ET 200SP IM 155-6 PN ST BA TX RAILSIMOTION P V4.4 and V4.5SINAMICS S150 V4.8 w. PNSIMATIC ET 200M (incl. SIPLUS variants)SIMATIC Compact Field UnitSIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants)SIMATIC S7-200 SMARTSINAMICS G130 V4.7 w. PNSIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)SIPLUS ET 200MP IM 155-5 PN STSIMATIC WinAC RTX F 2010SINAMICS S150 V4.7 w. PNSINAMICS SM120 V4.7 w. PROFINETSIMATIC ET 200AL IM 157-1 PNSIMATIC ET200ecoPN, 8DI, DC24V, 8xM12SIPLUS ET 200SP IM 155-6 PN STSIPLUS ET 200MP IM 155-5 PN ST TX RAILSIPLUS ET 200MP IM 155-5 PN HFSINAMICS GH150 V4.7 w. PROFINETSINAMICS G150 V4.8 w. PN
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2024-22044
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.30% / 52.63%
||
7 Day CHG~0.00%
Published-12 Mar, 2024 | 10:21
Updated-26 Aug, 2024 | 18:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SENTRON 3KC ATC6 Expansion Module Ethernet (3KC9000-8TL75) (All versions). Affected devices expose an unused, unstable http service at port 80/tcp on the Modbus-TCP Ethernet. This could allow an attacker on the same Modbus network to create a denial of service condition that forces the device to reboot.

Action-Not Available
Vendor-Siemens AG
Product-SENTRON 3KC ATC6 Expansion Module Ethernetsentron_3kc_act6
CWE ID-CWE-912
Hidden Functionality
CVE-2009-3322
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-13.09% / 93.84%
||
7 Day CHG~0.00%
Published-23 Sep, 2009 | 10:00
Updated-07 Aug, 2024 | 06:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Siemens Gigaset SE361 WLAN router allows remote attackers to cause a denial of service (device reboot) via a flood of crafted TCP packets to port 1723.

Action-Not Available
Vendor-n/aSiemens AG
Product-gigaset_se361_wlan_routern/a
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 17
  • 18
  • Next
Details not found