Controller DoS may occur due to buffer overflow when an error is generated in response to a specially crafted message. See Honeywell Security Notification for recommendations on upgrading and versioning.
Server or Console Station DoS due to heap overflow occurring during the handling of a specially crafted message for a specific configuration operation. See Honeywell Security Notification for recommendations on upgrading and versioning.
Controller DoS due to stack overflow when decoding a message from the server. See Honeywell Security Notification for recommendations on upgrading and versioning.
Controller may be loaded with malicious firmware which could enable remote code execution. See Honeywell Security Notification for recommendations on upgrading and versioning.
Experion server DoS due to heap overflow occurring during the handling of a specially crafted message for a specific configuration operation. See Honeywell Security Notification for recommendations on upgrading and versioning.
Honeywell Experion PKS Safety Manager (SM and FSC) through 2022-05-06 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0053, there is a Honeywell Experion PKS Safety Manager insufficient logic security controls issue. The affected components are characterized as: Honeywell FSC runtime (FSC-CPU, QPP), Honeywell Safety Builder. The potential impact is: Remote Code Execution, Denial of Service. The Honeywell Experion PKS Safety Manager family of safety controllers utilize the unauthenticated Safety Builder protocol (FSCT-2022-0051) for engineering purposes, including downloading projects and control logic to the controller. Control logic is downloaded to the controller on a block-by-block basis. The logic that is downloaded consists of FLD code compiled to native machine code for the CPU module (which applies to both the Safety Manager and FSC families). Since this logic does not seem to be cryptographically authenticated, it allows an attacker capable of triggering a logic download to execute arbitrary machine code on the controller's CPU module in the context of the runtime. While the researchers could not verify this in detail, the researchers believe that the microprocessor underpinning the FSC and Safety Manager CPU modules is incapable of offering memory protection or privilege separation capabilities which would give an attacker full control of the CPU module. There is no authentication on control logic downloaded to the controller. Memory protection and privilege separation capabilities for the runtime are possibly lacking. The researchers confirmed the issues in question on Safety Manager R145.1 and R152.2 but suspect the issue affects all FSC and SM controllers and associated Safety Builder versions regardless of software or firmware revision. An attacker who can communicate with a Safety Manager controller via the Safety Builder protocol can execute arbitrary code without restrictions on the CPU module, allowing for covert manipulation of control operations and implanting capabilities similar to the TRITON malware (MITRE ATT&CK software ID S1009). A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.
Honeywell Notifier Web Server (NWS) Version 3.50 is vulnerable to a path traversal attack, which allows an attacker to bypass access to restricted directories. Honeywell has released a firmware update to address the problem.
The following versions of MAXPRO VMS and NVR, MAXPRO VMS:HNMSWVMS prior to Version VMS560 Build 595 T2-Patch, HNMSWVMSLT prior to Version VMS560 Build 595 T2-Patch, MAXPRO NVR: MAXPRO NVR XE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR SE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR PE prior to Version NVR 5.6 Build 595 T2-Patch, and MPNVRSWXX prior to Version NVR 5.6 Build 595 T2-Patch are vulnerable to an unsafe deserialization of untrusted data. An attacker may be able to remotely modify deserialized data without authentication using a specially crafted web request, resulting in remote code execution.
The following versions of MAXPRO VMS and NVR, MAXPRO VMS:HNMSWVMS prior to Version VMS560 Build 595 T2-Patch, HNMSWVMSLT prior to Version VMS560 Build 595 T2-Patch, MAXPRO NVR: MAXPRO NVR XE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR SE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR PE prior to Version NVR 5.6 Build 595 T2-Patch, and MPNVRSWXX prior to Version NVR 5.6 Build 595 T2-Patch contain an SQL injection vulnerability that could give an attacker remote unauthenticated access to the web user interface with administrator-level privileges.
The affected product is vulnerable to a heap-based buffer overflow, which may allow an attacker to manipulate memory with controlled values and remotely execute code on the OPC UA Tunneller (versions prior to 6.3.0.8233).
Improper Input Validation vulnerability in Honeywell PM43 on 32 bit, ARM (Printer web page modules) allows Command Injection.This issue affects PM43 versions prior to P10.19.050004. Update to the latest available firmware version of the respective printers to version MR19.5 (e.g. P10.19.050006).
Honeywell equIP series and Performance series IP cameras and recorders, A vulnerability exists in the affected products where IP cameras and recorders have a potential replay attack vulnerability as a weak authentication method is retained for compatibility with legacy products.
** UNSUPPORTED WHEN ASSIGNED ** [An attacker can capture an authenticating hash and utilize it to create new sessions. The hash is also a poorly salted MD5 hash, which could result in a successful brute force password attack. Impacted product is BCM-WEB version 3.3.X. Recommended fix: Upgrade to a supported product such as Alerton ACM.] Out of an abundance of caution, this CVE ID is being assigned to better serve our customers and ensure all who are still running this product understand that the product is end of life and should be removed or upgraded.
Honeywell Experion PKS C200, C200E, C300, and ACE controllers are vulnerable to improper neutralization of special elements in output, which may allow an attacker to remotely execute arbitrary code and cause a denial-of-service condition.
Honeywell HDZP252DI 1.00.HW02.4 and HBW2PER1 1.000.HW01.3 devices allow a video replay attack after ARP cache poisoning has been achieved.
Honeywell Experion PKS Safety Manager 5.02 uses Hard-coded Credentials. According to FSCT-2022-0052, there is a Honeywell Experion PKS Safety Manager hardcoded credentials issue. The affected components are characterized as: POLO bootloader. The potential impact is: Manipulate firmware. The Honeywell Experion PKS Safety Manager utilizes the DCOM-232/485 serial interface for firmware management purposes. When booting, the Safety Manager exposes the Enea POLO bootloader via this interface. Access to the boot configuration is controlled by means of credentials hardcoded in the Safety Manager firmware. The credentials for the bootloader are hardcoded in the firmware. An attacker with access to the serial interface (either through physical access, a compromised EWS or an exposed serial-to-ethernet gateway) can utilize these credentials to control the boot process and manipulate the unauthenticated firmware image (see FSCT-2022-0054).
TELSAT marKoni FM Transmitters are vulnerable to an attacker exploiting a hidden admin account that can be accessed through the use of hard-coded credentials.
Clinic Image System developed by Changing contains hard-coded Credentials, allowing unauthenticated remote attackers to log into the system using administrator credentials embedded in the source code.
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 was discovered to contain a hard-coded default password for the RTSP feed.
H3C R3010 v100R002L02 was discovered to contain a hardcoded password vulnerability in /etc/shadow, which allows attackers to log in as root.
TOTOLINK CP300 V2.0.4-B20201102 was discovered to contain a hardcoded password vulnerability in /etc/shadow.sample, which allows attackers to log in as root.
An issue was discovered in the box application on HiSilicon based IPTV/H.264/H.265 video encoders. Attackers can use hard-coded credentials in HTTP requests to perform any administrative task on the device including retrieving the device's configuration (with the cleartext admin password), and uploading a custom firmware update, to ultimately achieve arbitrary code execution.
In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a remote, unauthenticated attacker could make use of hard-coded credentials to gain full access to the device.
Hard-coded credentials in Web-UI of multiple VARTA Storage products in multiple versions allows an unauthorized attacker to gain administrative access to the Web-UI via network.
IBM Security Verify Governance 10.0 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 225222.
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 does not defend against physical access to U-Boot via the UART: the Wi-Fi password is shown, and the hardcoded boot password can be inserted for console access.
The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions.
In projectworlds Online Book Store 1.0 Use of Hard-coded Credentials in source code leads to admin panel access.
Tenda i29V1.0 V1.0.0.5 was discovered to contain a hardcoded password for root.
Rocket Software UniData versions prior to 8.2.4 build 3003 and UniVerse versions prior to 11.3.5 build 1001 or 12.2.1 build 2002 suffer from an authentication bypass vulnerability, where a special username with a deterministic password can be leveraged to bypass authentication checks and execute OS commands as the root user.
Osprey Pump Controller version 1.01 has a hidden administrative account that has the hardcoded password that allows full access to the web management interface configuration. The user is not visible in Usernames and Passwords menu list of the application and the password cannot be changed through any normal operation of the device.
PanIndex is a network disk directory index. In Panindex prior to version 3.1.3, a hard-coded JWT key `PanIndex` is used. An attacker can use the hard-coded JWT key to sign JWT token and perform any actions as a user with admin privileges. Version 3.1.3 has a patch for the issue. As a workaround, one may change the JWT key in the source code before compiling the project.
In D-Link DIR-860L REVA FIRMWARE PATCH 1.10..B04, the Telnet service contains hardcoded credentials, enabling attackers to log in remotely to the Telnet service and perform arbitrary commands.
Dragonfly is an open source P2P-based file distribution and image acceleration system. It is hosted by the Cloud Native Computing Foundation (CNCF) as an Incubating Level Project. Dragonfly uses JWT to verify user. However, the secret key for JWT, "Secret Key", is hard coded, which leads to authentication bypass. An attacker can perform any action as a user with admin privileges. This issue has been addressed in release version 2.0.9. All users are advised to upgrade. There are no known workarounds for this vulnerability.
An issue was discovered on URayTech IPTV/H.264/H.265 video encoders through 1.97. Attackers can log in as root via the password that is hard-coded in the executable file.
The Le-yan dental management system contains a hard-coded credentials vulnerability in the web page source code, which allows an unauthenticated remote attacker to acquire administrator’s privilege and control the system or disrupt service.
European Chemicals Agency IUCLID 6.x before 6.27.6 allows authentication bypass because a weak hard-coded secret is used for JWT signing. The affected versions are 5.15.0 through 6.27.5.
Advantech R-SeeNet versions 2.4.22 is installed with a hidden root-level user that is not available in the users list. This hidden user has a password that cannot be changed by users.
man-group/dtale version 3.10.0 is vulnerable to an authentication bypass and remote code execution (RCE) due to improper input validation. The vulnerability arises from a hardcoded `SECRET_KEY` in the flask configuration, allowing attackers to forge a session cookie if authentication is enabled. Additionally, the application fails to properly restrict custom filter queries, enabling attackers to execute arbitrary code on the server by bypassing the restriction on the `/update-settings` endpoint, even when `enable_custom_filters` is not enabled. This vulnerability allows attackers to bypass authentication mechanisms and execute remote code on the server.
Shenzhen Guoxin Synthesis image system before 8.3.0 has a 123456Qw default password.
Linksys WAP54Gv3 firmware 3.04.03 and earlier uses a hard-coded username (Gemtek) and password (gemtekswd) for a debug interface for certain web pages, which allows remote attackers to execute arbitrary commands via the (1) data1, (2) data2, or (3) data3 parameters to (a) Debug_command_page.asp and (b) debug.cgi.
Gradio is an open-source Python library to build machine learning and data science demos and web applications. Versions prior to 3.13.1 contain Use of Hard-coded Credentials. When using Gradio's share links (i.e. creating a Gradio app and then setting `share=True`), a private SSH key is sent to any user that connects to the Gradio machine, which means that a user could access other users' shared Gradio demos. From there, other exploits are possible depending on the level of access/exposure the Gradio app provides. This issue is patched in version 3.13.1, however, users are recommended to update to 3.19.1 or later where the FRP solution has been properly tested.
A Hard Coded Admin Credentials issue in the Web-UI Admin Panel in Propius MachineSelector 6.6.0 and 6.6.1 allows remote attackers to gain access to the admin panel Propiusadmin.php, which allows taking control of the affected system.
A hard-coded password vulnerability exists in the libcommonprod.so prod_change_root_passwd functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. During system startup this functionality is always called, leading to a known root password. An attacker does not have to do anything to trigger this vulnerability.
TOTOLINK T8 V4.1.5cu was discovered to contain a hard code password for the telnet service which is stored in the component /web_cste/cgi-bin/product.ini.
Electra Central AC unit – Hardcoded Credentials in unspecified code used by the unit.
TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a hard code password for root which is stored in the component /etc/shadow.
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as very critical, has been found in D-Link DNS-320L, DNS-325, DNS-327L and DNS-340L up to 20240403. This issue affects some unknown processing of the file /cgi-bin/nas_sharing.cgi of the component HTTP GET Request Handler. The manipulation of the argument user with the input messagebus leads to hard-coded credentials. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-259283. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
Use of Hard-coded Credentials vulnerability in Samsung Electronics MagicINFO 9 Server allows Authentication Bypass.This issue affects MagicINFO 9 Server: less than 21.1080.0.
Files present on firmware images could allow an attacker to gain unauthorized access as a root user using hard-coded credentials.