Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Improper Privilege Management vulnerability in ABB Ltd. ASPECT®-Enterprise on ASPECT®-Enterprise, Linux (2CQG103201S3021, 2CQG103202S3021, 2CQG103203S3021, 2CQG103204S3021 modules), ABB Ltd. NEXUS Series on NEXUS Series, Linux (2CQG100102R2021, 2CQG100104R2021, 2CQG100105R2021, 2CQG100106R2021, 2CQG100110R2021, 2CQG100112R2021, 2CQG100103R2021, 2CQG100107R2021, 2CQG100108R2021, 2CQG100109R2021, 2CQG100111R2021, 2CQG100113R2021 modules), ABB Ltd. MATRIX Series on MATRIX Series, Linux (2CQG100102R1021, 2CQG100103R1021, 2CQG100104R1021, 2CQG100105R1021, 2CQG100106R1021 modules) allows Privilege Escalation.This issue affects ASPECT®-Enterprise: from 3.0;0 before 3.07.01; NEXUS Series: from 3.0;0 before 3.07.01; MATRIX Series: from 3.0;0 before 3.07.01.
Incorrect Permission Assignment for Critical Resource vulnerability in ABB Automation Builder.This issue affects Automation Builder: through 2.8.0.
This vulnerability allows local attackers to escalate privileges on vulnerable installations of ABB MicroSCADA 9.3 with FP 1-2-3. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the configuration of the access controls for the installed product files. The installation procedure leaves critical files open to manipulation by any authenticated user. An attacker can leverage this vulnerability to escalate privileges to SYSTEM. Was ZDI-CAN-5097.
Insufficient protection of the inter-process communication functions in ABB System 800xA Batch Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting User Interface update during batch execution and/or compare/printing functionalities.
Weak Registry permissions in ABB System 800xA Base allow low privileged users to read and modify registry settings related to control system functionality, allowing an authenticated attacker to cause system functions to stop or malfunction.
Insufficient protection of the inter-process communication functions in ABB System 800xA Information Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting the runtime values to be stored in the archive, or making Information Management history services unavailable.
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code.
Insecure storage of sensitive information in ABB Device Library Wizard versions 6.0.X, 6.0.3.1 and 6.0.3.2 allows unauthenticated low privilege user to read file that contains confidential data
Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and earlier) and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploited the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications.
Insufficient protection of the inter-process communication functions in ABB System 800xA RNRP (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
Unquoted Search Path or Element vulnerability in ABB Mint Workbench. A local attacker who successfully exploited this vulnerability could gain elevated privileges by inserting an executable file in the path of the affected service. This issue affects Mint Workbench I versions: from 5866 before 5868.
Insufficient protection of the inter-process communication functions in ABB System 800xA Base (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
Insufficient folder permissions used by system functions in ABB System 800xA Base (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploit the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications.
Vulnerabilities in the Mint WorkBench allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Mint WorkBench installer file allows a low-privileged user to run a "repair" operation on the product
Incorrect Default Permissions vulnerability in ABB e-Design allows attacker to install malicious software executing with SYSTEM permissions violating confidentiality, integrity, and availability of the target machine.
An attacker could exploit the vulnerability by injecting garbage data or specially crafted data. Depending on the data injected each process might be affected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing the product to store wrong information or act on wrong data or display wrong information. This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2. For an attack to be successful, the attacker must have local access to a node in the system and be able to start a specially crafted application that disrupts the communication. An attacker who successfully exploited the vulnerability would be able to manipulate the data in such way as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300 and AdvaBuild to crash.
Insertion of Sensitive Information into Log File vulnerability in ABB QCS 800xA, ABB QCS AC450, ABB Platform Engineering Tools. An attacker, who already has local access to the QCS nodes, could successfully obtain the password for a system user account. Using this information, the attacker could have the potential to exploit this vulnerability to gain control of system nodes. This issue affects QCS 800xA: from 1.0;0 through 6.1SP2; QCS AC450: from 1.0;0 through 5.1SP2; Platform Engineering Tools: from 1.0:0 through 2.3.0.
Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
Replay Attack in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to capture/replay KNX telegram to local KNX Bus-System
In Symphony Plus Operations and Symphony Plus Historian, some services can be vulnerable to privilege escalation attacks. An unprivileged (but authenticated) user could execute arbitrary code and result in privilege escalation, depending on the user that the service runs as.
G DATA Total Security Scan Server Link Following Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of G DATA Total Security. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the G DATA AntiVirus Scan Server. By creating a symbolic link, an attacker can abuse the service to delete arbitrary files. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-23381.
atop: symlink attack possible due to insecure tempfile handling
An unprivileged (non-admin) user can exploit an Improper Access Control vulnerability in the Cloudflare WARP Client for Windows (<= 2022.12.582.0) to perform privileged operations with SYSTEM context by working with a combination of opportunistic locks (oplock) and symbolic links (which can both be created by an unprivileged user). After installing the Cloudflare WARP Client (admin privileges required), an MSI-Installer is placed under C:\Windows\Installer. The vulnerability lies in the repair function of this MSI. ImpactAn unprivileged (non-admin) user can exploit this vulnerability to perform privileged operations with SYSTEM context, including deleting arbitrary files and reading arbitrary file content. This can lead to a variety of attacks, including the manipulation of system files and privilege escalation. PatchesA new installer with a fix that addresses this vulnerability was released in version 2023.3.381.0. While the WARP Client itself is not vulnerable (only the installer), users are encouraged to upgrade to the latest version and delete any older installers present in their systems.
A vulnerability has been discovered in cloudflared's installer (<= 2023.3.0) for Windows 32-bits devices that allows a local attacker with no administrative permissions to escalate their privileges on the affected device. This vulnerability exists because the MSI installer used by cloudflared relied on a world-writable directory. An attacker with local access to the device (without Administrator rights) can use symbolic links to trick the MSI installer into deleting files in locations that the attacker would otherwise have no access to. By creating a symlink from the world-writable directory to the target file, the attacker can manipulate the MSI installer's repair functionality to delete the target file during the repair process. Exploitation of this vulnerability could allow an attacker to delete important system files or replace them with malicious files, potentially leading to the affected device being compromised. The cloudflared client itself is not affected by this vulnerability, only the installer for 32-bit Windows devices.
The nginx package before 1.6.2-5+deb8u3 on Debian jessie, the nginx packages before 1.4.6-1ubuntu3.6 on Ubuntu 14.04 LTS, before 1.10.0-0ubuntu0.16.04.3 on Ubuntu 16.04 LTS, and before 1.10.1-0ubuntu1.1 on Ubuntu 16.10, and the nginx ebuild before 1.10.2-r3 on Gentoo allow local users with access to the web server user account to gain root privileges via a symlink attack on the error log.
Microsoft Install Service Elevation of Privilege Vulnerability
Microsoft Office Elevation of Privilege Vulnerability
Microsoft PLUGScheduler Scheduled Task Elevation of Privilege Vulnerability
Due to a hardlink created in the ProgramData folder during the repair process of the software, the installer (MSI) of WARP Client for Windows (<= 2022.12.582.0) allowed a malicious attacker to forge the destination of the hardlink and escalate privileges, overwriting SYSTEM protected files. As Cloudflare WARP client for Windows (up to version 2022.5.309.0) allowed creation of mount points from its ProgramData folder, during installation of the WARP client, it was possible to escalate privileges and overwrite SYSTEM protected files.
systemd-tmpfiles in systemd through 237 mishandles symlinks present in non-terminal path components, which allows local users to obtain ownership of arbitrary files via vectors involving creation of a directory and a file under that directory, and later replacing that directory with a symlink. This occurs even if the fs.protected_symlinks sysctl is turned on.
This issue was addressed with improved handling of symlinks. This issue is fixed in macOS Sonoma 14.4. An app may be able to create symlinks to protected regions of the disk.
AMD fglrx-driver before 15.7 allows local users to gain privileges via a symlink attack.
AMD fglrx-driver before 15.9 allows local users to gain privileges via a symlink attack. NOTE: This vulnerability exists due to an incomplete fix for CVE-2015-7723.
A link following vulnerability in the Damage Cleanup Engine component of Trend Micro Apex One and Trend Micro Apex One as a Service could allow a local attacker to escalate privileges by creating a symbolic link and abusing the service to delete a file. Please note: an attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability.
Windows Authentication Elevation of Privilege Vulnerability
Microsoft Edge (Chromium-based) Elevation of Privilege Vulnerability
Visual Studio Elevation of Privilege Vulnerability
Link Following Local Privilege Escalation Vulnerability in TuneupSvc.exe in AVG TuneUp 24.2.16593.9844 on Windows allows local attackers to escalate privileges and execute arbitrary code in the context of SYSTEM via creating a symbolic link and leveraging the service to delete a directory
G DATA Total Security Link Following Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of G DATA Total Security. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the G DATA Backup Service. By creating a symbolic link, an attacker can abuse the service to delete a file. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-22312.
G DATA Total Security Link Following Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of G DATA Total Security. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the G DATA Backup Service. By creating a symbolic link, an attacker can abuse the service to overwrite a file. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-22313.
Link Following Local Privilege Escalation Vulnerability in TuneUp Service in AVG TuneUp Version 23.4 (build 15592) on Windows 10 allows local attackers to escalate privileges and execute arbitrary code in the context of SYSTEM via creating a symbolic link and leveraging a TOCTTOU (time-of-check to time-of-use) attack.
Link Following Local Privilege Escalation Vulnerability in TuneupSvc in Avast Cleanup Premium Version 24.2.16593.17810 on Windows 10 Pro x64 allows local attackers to escalate privileges and execute arbitrary code in the context of SYSTEM via creating a symbolic link and leveraging a TOCTTOU (time-of-check to time-of-use) attack.
Link Following Local Privilege Escalation Vulnerability in TuneupSvc in Gen Digital Inc. Avast Cleanup Premium Version 24.2.16593.17810 on Windows 10 Pro x64 allows local attackers to escalate privileges and execute arbitrary code in the context of SYSTEM via creating a symbolic link and leveraging a TOCTTOU (time-of-check to time-of-use) attack.
Local Privilege Escalation in Avira.Spotlight.Service.exe in Avira Prime 1.1.96.2 on Windows 10 x64 allows local attackers to gain system-level privileges via arbitrary file deletion
Panda Security Dome Link Following Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of Panda Security Dome. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the Hotspot Shield. By creating a junction, an attacker can abuse the application to delete arbitrary files. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-23478.
Wacom Center WTabletServicePro Link Following Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of Wacom Center. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within WTabletServicePro.exe. By creating a symbolic link, an attacker can abuse the service to create an arbitrary file. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-25359.